Skip to main content
Top
Published in: Meccanica 3/2017

14-11-2016 | Advances in Biomechanics: from foundations to applications

Self-adjustment mechanisms and their application for orthosis design

Authors: Viet Anh Dung Cai, Philippe Bidaud, Vincent Hayward, Florian Gosselin

Published in: Meccanica | Issue 3/2017

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

Medical orthoses aim at guiding anatomical joints along their natural trajectories while preventing pathological movements, especially in case of trauma or injuries. The motions that take place between bone surfaces have complex kinematics. These so-called arthrokinematic motions exhibit axes that move both in translation and rotation. Traditionally, orthoses are carefully adjusted and positioned such that their kinematics approximate the arthrokinematic movements as closely as possible in order to protect the joint. Adjustment procedures are typically long and tedious. We suggest in this paper another approach. We propose mechanisms having intrinsic self-aligning properties. They are designed such that their main axis self-adjusts with respect to the joint’s physiological axis during motion. When connected to a limb, their movement becomes homokinetic and they have the property of automatically minimizing internal stresses. The study is performed here in the planar case focusing on the most important component of the arthrokinematic motions of a knee joint.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Appendix
Available only for authorised users
Literature
1.
go back to reference Wu G, Cavanagh PR (1995) ISB recommendations for standardization in the reporting of kinematic data. J Biomech 28(10):1257–1261CrossRef Wu G, Cavanagh PR (1995) ISB recommendations for standardization in the reporting of kinematic data. J Biomech 28(10):1257–1261CrossRef
2.
go back to reference Goodfellow J, O’Connor J (1978) The mechanics of the knee and prothesis design. J Bone Joint Surg 60:358–369 Goodfellow J, O’Connor J (1978) The mechanics of the knee and prothesis design. J Bone Joint Surg 60:358–369
3.
go back to reference Winsman J, Veldpaus F, Janssen J, Huson A, Struben P (1980) A three-dimensional mathematical model of the knee-joint. J Biomech 13:677–685CrossRef Winsman J, Veldpaus F, Janssen J, Huson A, Struben P (1980) A three-dimensional mathematical model of the knee-joint. J Biomech 13:677–685CrossRef
4.
go back to reference Sancisi N, Parenti-Castelli V (2011) A sequentially-defined stiffness model of the knee. Mech Mach Theory 46(12):1920–1928CrossRefMATH Sancisi N, Parenti-Castelli V (2011) A sequentially-defined stiffness model of the knee. Mech Mach Theory 46(12):1920–1928CrossRefMATH
5.
go back to reference Sancisi N, Parenti-Castelli V (2011) A new kinematic model of the passive motion of the knee inclusive of the patella. J Mech Robot 3(4):041003CrossRefMATH Sancisi N, Parenti-Castelli V (2011) A new kinematic model of the passive motion of the knee inclusive of the patella. J Mech Robot 3(4):041003CrossRefMATH
6.
go back to reference Markolf KL, Kochan A, Amstutz HC (1984) Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament. J Bone Joint Surg 66:242–252CrossRef Markolf KL, Kochan A, Amstutz HC (1984) Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament. J Bone Joint Surg 66:242–252CrossRef
7.
go back to reference Roaas A, Andersson GBJ (1982) Normal range of motion of the hip, knee and ankle joints in male subjects, 30–40 years of age. Acta Orthop Scand 53(2):205–208CrossRef Roaas A, Andersson GBJ (1982) Normal range of motion of the hip, knee and ankle joints in male subjects, 30–40 years of age. Acta Orthop Scand 53(2):205–208CrossRef
8.
go back to reference O’Connor J, Goodfellow J (1978) The mechanics of the knee and prothesis design. J Bone Jt Surg O’Connor J, Goodfellow J (1978) The mechanics of the knee and prothesis design. J Bone Jt Surg
9.
go back to reference Cai VAD, Bru B, Bidaud P, Hayward V, Gosselin F, Pasqui V (2010) Experimental evaluation of a goniometer for the identification of anatomical joint motions. In: Proceedings of the 13th international conference on climbing and walking robots and the support technologies for mobile machines, pp 1255-1262 Cai VAD, Bru B, Bidaud P, Hayward V, Gosselin F, Pasqui V (2010) Experimental evaluation of a goniometer for the identification of anatomical joint motions. In: Proceedings of the 13th international conference on climbing and walking robots and the support technologies for mobile machines, pp 1255-1262
10.
go back to reference Walker PS, Kurosawa H, Rovick JS, Zimmerman RA (1985) External knee joint design based on normal motion. J Rehabil Res Dev 22:9–22CrossRef Walker PS, Kurosawa H, Rovick JS, Zimmerman RA (1985) External knee joint design based on normal motion. J Rehabil Res Dev 22:9–22CrossRef
11.
go back to reference Aaserude GV, Rubin RH (1987) Polycentric Variable Axis Hinge, United States Patent, Pub. Num. 4.699.129 Aaserude GV, Rubin RH (1987) Polycentric Variable Axis Hinge, United States Patent, Pub. Num. 4.699.129
12.
go back to reference Herzberg T, Albrod A, Orthosis Knee-Joint (2001) United States Patent, Pub. Num. 6,309,368 B1 Herzberg T, Albrod A, Orthosis Knee-Joint (2001) United States Patent, Pub. Num. 6,309,368 B1
13.
go back to reference Lamb SR, Moore R (1985) Anatomic Fracture Brace For The Knee, United States Patent, Pub. Num. 4,523,585 Lamb SR, Moore R (1985) Anatomic Fracture Brace For The Knee, United States Patent, Pub. Num. 4,523,585
14.
go back to reference Lambert G, Orthosis Knee (2006) United States Patent, Pub. Num. US2006/0089581 A1 Lambert G, Orthosis Knee (2006) United States Patent, Pub. Num. US2006/0089581 A1
15.
go back to reference Reynolds R, Weber R, Landsberger S, Orthesis Knee (2006) United States Patent, Patent Num. US 2006/0211967 A1 Reynolds R, Weber R, Landsberger S, Orthesis Knee (2006) United States Patent, Patent Num. US 2006/0211967 A1
16.
go back to reference Spring AN, Kofman J, Lemaire ED (2012) Design and evaluation of an orthotic knee-extension assist. IEEE Trans Neural Syst Rehabil Eng 20(5):678–687CrossRef Spring AN, Kofman J, Lemaire ED (2012) Design and evaluation of an orthotic knee-extension assist. IEEE Trans Neural Syst Rehabil Eng 20(5):678–687CrossRef
17.
go back to reference Shamaei K, Napolitano P, Dollar AM (2014) Design and functional evaluation of a quasi-passive compliant stance control kneeanklefoot orthosis. IEEE Trans Neural Syst Rehabil Eng 22(2):258–268CrossRef Shamaei K, Napolitano P, Dollar AM (2014) Design and functional evaluation of a quasi-passive compliant stance control kneeanklefoot orthosis. IEEE Trans Neural Syst Rehabil Eng 22(2):258–268CrossRef
18.
go back to reference Weinberg B, Nikitczuk J, Patel S, Patritti B, Mavroidis C, Bonato P, Canavan P (2007) Design, control and human testing of an active knee rehabilitation orthotic device. In: IEEE international conference on robotics and automation, pp 4126–4133 Weinberg B, Nikitczuk J, Patel S, Patritti B, Mavroidis C, Bonato P, Canavan P (2007) Design, control and human testing of an active knee rehabilitation orthotic device. In: IEEE international conference on robotics and automation, pp 4126–4133
19.
go back to reference Cai D, Bidaud P, Hayward V, Gosselin F (2009) Design of self-adjusting orthoses for rehabilitation. In: Proceedings of the 14th IASTED international conference on robotics and applications, Cambridge. MA, USA, pp 215–223 Cai D, Bidaud P, Hayward V, Gosselin F (2009) Design of self-adjusting orthoses for rehabilitation. In: Proceedings of the 14th IASTED international conference on robotics and applications, Cambridge. MA, USA, pp 215–223
20.
go back to reference Cai VAD, Bidaud P, Hayward V, Gosselin F, Desailly Eric (2011) Self-adjusting, isostatic exoskeleton for the human knee joint. In: Annual international conference of the IEEE engineering in medicine and biology society, pp 612-618 Cai VAD, Bidaud P, Hayward V, Gosselin F, Desailly Eric (2011) Self-adjusting, isostatic exoskeleton for the human knee joint. In: Annual international conference of the IEEE engineering in medicine and biology society, pp 612-618
21.
go back to reference Celebi B, Yalcin M, Patoglu V (2013) ASSISTON-KNEE: a self-aligning knee exoskeleton. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), 2013, Japan, pp 996–1002 Celebi B, Yalcin M, Patoglu V (2013) ASSISTON-KNEE: a self-aligning knee exoskeleton. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), 2013, Japan, pp 996–1002
22.
go back to reference Jarasse N, Morel G (2011) Connecting a human limb to an exoskeleton. IEEE Trans Robot 28(3):697–710CrossRef Jarasse N, Morel G (2011) Connecting a human limb to an exoskeleton. IEEE Trans Robot 28(3):697–710CrossRef
23.
go back to reference Ergin MA, Patoglu V, Self-Adjusting Knee Exoskeleton A, for Robot-Assisted Treatment of Knee Injuries, Proc. IEEE, RSJ Int. Conf. on Intelligent Robots and Systems, September 25–30, 2011. San Francisco. CA, USA, pp 4917–4922 Ergin MA, Patoglu V, Self-Adjusting Knee Exoskeleton A, for Robot-Assisted Treatment of Knee Injuries, Proc. IEEE, RSJ Int. Conf. on Intelligent Robots and Systems, September 25–30, 2011. San Francisco. CA, USA, pp 4917–4922
24.
go back to reference Schorsch JF, Keemink AQL, Stienen AHA, van der Helm FCT, Abbink DA (2014) A novel self-aligning mechanism to decouple force and torques for a planar exoskeleton joint. Mech Sci 5:2935CrossRef Schorsch JF, Keemink AQL, Stienen AHA, van der Helm FCT, Abbink DA (2014) A novel self-aligning mechanism to decouple force and torques for a planar exoskeleton joint. Mech Sci 5:2935CrossRef
25.
go back to reference Stienen AHA, Hekman EEG, van der Helm FCT, van der Kooij H (2009) Self-aligning exoskeleton axes through decoupling of joint rotations and translations. IEEE Trans Robot 25:628–633CrossRef Stienen AHA, Hekman EEG, van der Helm FCT, van der Kooij H (2009) Self-aligning exoskeleton axes through decoupling of joint rotations and translations. IEEE Trans Robot 25:628–633CrossRef
26.
go back to reference Ding X, Dai JS (2010) Compliance analysis of mechanisms with spatial continuous compliance in the context of screw theory and Lie groups. J Mech Eng Sci Proc I MechE Part C 224(11):2493–2504CrossRef Ding X, Dai JS (2010) Compliance analysis of mechanisms with spatial continuous compliance in the context of screw theory and Lie groups. J Mech Eng Sci Proc I MechE Part C 224(11):2493–2504CrossRef
27.
go back to reference Kinzel GL, Hall AS, Hillberry BM (1972) Measurement of the total motion between two body segments—i. analytical development. J Biomech 5:93–105CrossRef Kinzel GL, Hall AS, Hillberry BM (1972) Measurement of the total motion between two body segments—i. analytical development. J Biomech 5:93–105CrossRef
Metadata
Title
Self-adjustment mechanisms and their application for orthosis design
Authors
Viet Anh Dung Cai
Philippe Bidaud
Vincent Hayward
Florian Gosselin
Publication date
14-11-2016
Publisher
Springer Netherlands
Published in
Meccanica / Issue 3/2017
Print ISSN: 0025-6455
Electronic ISSN: 1572-9648
DOI
https://doi.org/10.1007/s11012-016-0574-0

Other articles of this Issue 3/2017

Meccanica 3/2017 Go to the issue

Advances in Biomechanics: from foundations to applications

Fluid flow in a helical vessel in presence of a stenosis

Advances in Biomechanics: from foundations to applications

Multi-scale modelling of textile reinforced artificial tubular aortic heart valves

Advances in Biomechanics: from foundations to applications

Growth and remodeling of load-bearing biological soft tissues

Advances in Biomechanics: from foundations to applications

Patient-specific finite element analysis of popliteal stenting

Advances in Biomechanics: from foundations to applications

Effective computational modeling of erythrocyte electro-deformation

Premium Partners