Skip to main content
Top
Published in: Experiments in Fluids 12/2020

01-12-2020 | Research Article

Tomographic PIV analysis of physiological flow conditions in a patient-specific arteriovenous fistula

Authors: Sanjiv Gunasekera, Olivia Ng, Shannon Thomas, Ramon Varcoe, Charitha de Silva, Tracie Barber

Published in: Experiments in Fluids | Issue 12/2020

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

The arteriovenous fistula (AVF), which is a vasculature created for end-stage renal disease patients who require haemodialysis, is susceptible to many vascular diseases. It is well known that disturbed hemodynamics is a factor in the initiation of vascular disease; however, only a limited number of experimental studies have been conducted to assess the flow behaviour within the AVF. The current study is an investigation of the complex three-dimensional flow within a physiological AVF geometry, using tomographic particle image velocimetry. To this end, a benchtop model of a patient-specific geometry was created by casting silicone around a soluble 3D print of the vessels. The patient-specific boundary conditions were reproduced by driving a refractive-index matched working fluid from a pulsatile pump, which was connected to the model via a tubing network inclusive of valves and compliance chambers. The seeded working fluid was illuminated with a 1 kHz double-pulsed laser, and four high-speed cameras placed at optimised locations were used to capture the particle images, with the volume reconstructions refined by a 3D internal mask created using morphological operations. The velocity magnitude contour plots of the resulting vector field revealed two zones of low velocity in the anastomosis, while locations of high turbulent kinetic energy are observed in the anastomosis and venous regions. These results suggested that the collision of the two opposing inlet flows and the curvature at the anastomosis cause disturbance in the flow that is carried downstream.

Graphic abstract

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Appendix
Available only for authorised users
Literature
go back to reference Al-Jaishi AA, Liu AR, Lok CE, Zhang JC, Moist LM (2017) Complications of the arteriovenous fistula: a systematic review. J Am Soc Nephrol 28(6):1839–1850CrossRef Al-Jaishi AA, Liu AR, Lok CE, Zhang JC, Moist LM (2017) Complications of the arteriovenous fistula: a systematic review. J Am Soc Nephrol 28(6):1839–1850CrossRef
go back to reference Botti L, Van Canneyt K, Kaminsky R, Claessens T, Planken RN, Verdonck P, Remuzzi A, Antiga L (2013) Numerical evaluation and experimental validation of pressure drops across a patient-specific model of vascular access for hemodialysis. Cardiovasc Eng Technol 4(4):485–499CrossRef Botti L, Van Canneyt K, Kaminsky R, Claessens T, Planken RN, Verdonck P, Remuzzi A, Antiga L (2013) Numerical evaluation and experimental validation of pressure drops across a patient-specific model of vascular access for hemodialysis. Cardiovasc Eng Technol 4(4):485–499CrossRef
go back to reference Buchmann N, Atkinson C, Jeremy M, Soria J (2011) Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation. Exp Fluids 50(4):1131–1151CrossRef Buchmann N, Atkinson C, Jeremy M, Soria J (2011) Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation. Exp Fluids 50(4):1131–1151CrossRef
go back to reference Carroll J, Varcoe RL, Barber T, Simmons A (2019) Reduction in anastomotic flow disturbance within a modified end-to-side arteriovenous fistula configuration: results of a computational flow dynamic model. Nephrology 24(2):245–251CrossRef Carroll J, Varcoe RL, Barber T, Simmons A (2019) Reduction in anastomotic flow disturbance within a modified end-to-side arteriovenous fistula configuration: results of a computational flow dynamic model. Nephrology 24(2):245–251CrossRef
go back to reference Carroll JE, Colley ES, Thomas SD, Varcoe RL, Simmons A, Barber TJ (2020) Tracking geometric and hemodynamic alterations of an arteriovenous fistula through patient-specific modelling. Comput Methods Programs Biomed 186:105203CrossRef Carroll JE, Colley ES, Thomas SD, Varcoe RL, Simmons A, Barber TJ (2020) Tracking geometric and hemodynamic alterations of an arteriovenous fistula through patient-specific modelling. Comput Methods Programs Biomed 186:105203CrossRef
go back to reference Colley E, Carroll J, Thomas S, Varcoe RL, Simmons A, Barber T (2018) A methodology for non-invasive 3-d surveillance of arteriovenous fistulae using freehand ultrasound. IEEE Trans Biomed Eng 65(8):1885–1891CrossRef Colley E, Carroll J, Thomas S, Varcoe RL, Simmons A, Barber T (2018) A methodology for non-invasive 3-d surveillance of arteriovenous fistulae using freehand ultrasound. IEEE Trans Biomed Eng 65(8):1885–1891CrossRef
go back to reference De Silva C, Baidya R, Khashehchi M, Marusic I (2012) Assessment of tomographic PIV in wall-bounded turbulence using direct numerical simulation data. Exp Fluids 52(2):425–440CrossRef De Silva C, Baidya R, Khashehchi M, Marusic I (2012) Assessment of tomographic PIV in wall-bounded turbulence using direct numerical simulation data. Exp Fluids 52(2):425–440CrossRef
go back to reference Decorato I, Kharboutly Z, Vassallo T, Penrose J, Legallais C, Salsac AV (2014) Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula. Int J Numer Methods Biomed Eng 30(2):143–159CrossRef Decorato I, Kharboutly Z, Vassallo T, Penrose J, Legallais C, Salsac AV (2014) Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula. Int J Numer Methods Biomed Eng 30(2):143–159CrossRef
go back to reference Duque JC, Tabbara M, Martinez L, Cardona J, Vazquez-Padron RI, Salman LH (2017) Dialysis arteriovenous fistula failure and angioplasty: intimal hyperplasia and other causes of access failure. Am J Kidney Dis 69(1):147–151CrossRef Duque JC, Tabbara M, Martinez L, Cardona J, Vazquez-Padron RI, Salman LH (2017) Dialysis arteriovenous fistula failure and angioplasty: intimal hyperplasia and other causes of access failure. Am J Kidney Dis 69(1):147–151CrossRef
go back to reference Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41(6):933–947CrossRef Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41(6):933–947CrossRef
go back to reference Ene-Iordache B, Remuzzi A (2017) Blood flow in idealized vascular access for hemodialysis: a review of computational studies. Cardiovasc Eng Technol 8(3):295–312CrossRef Ene-Iordache B, Remuzzi A (2017) Blood flow in idealized vascular access for hemodialysis: a review of computational studies. Cardiovasc Eng Technol 8(3):295–312CrossRef
go back to reference Fulker D, Ene-Iordache B, Barber T (2018) High-resolution computational fluid dynamic simulation of haemodialysis cannulation in a patient-specific arteriovenous fistula. J Biomech Eng 140(3):031011CrossRef Fulker D, Ene-Iordache B, Barber T (2018) High-resolution computational fluid dynamic simulation of haemodialysis cannulation in a patient-specific arteriovenous fistula. J Biomech Eng 140(3):031011CrossRef
go back to reference Gimbrone MA Jr, García-Cardeña G (2016) Endothelial cell dysfunction and the pathobiology of atherosclerosis. Circ Res 118(4):620–636CrossRef Gimbrone MA Jr, García-Cardeña G (2016) Endothelial cell dysfunction and the pathobiology of atherosclerosis. Circ Res 118(4):620–636CrossRef
go back to reference Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2019) Towards 3d PIV measurements of a patient-specific arteriovenous fistula. In: Alwahabi Z, Medwell P (eds) Proceedings of the 9th Australian conference on laser diagnostics. University of Adelaide, pp 87–90 Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2019) Towards 3d PIV measurements of a patient-specific arteriovenous fistula. In: Alwahabi Z, Medwell P (eds) Proceedings of the 9th Australian conference on laser diagnostics. University of Adelaide, pp 87–90
go back to reference He Y, Shiu YT, Pike DB, Roy-Chaudhury P, Cheung AK, Berceli SA (2018) Comparison of hemodialysis arteriovenous fistula blood flow rates measured by doppler ultrasound and phase-contrast magnetic resonance imaging. J Vasc Surg 68(6):1848–1857CrossRef He Y, Shiu YT, Pike DB, Roy-Chaudhury P, Cheung AK, Berceli SA (2018) Comparison of hemodialysis arteriovenous fistula blood flow rates measured by doppler ultrasound and phase-contrast magnetic resonance imaging. J Vasc Surg 68(6):1848–1857CrossRef
go back to reference Im S, Heo GE, Jeon YJ, Sung HJ, Kim SK (2014) Tomographic PIV measurements of flow patterns in a nasal cavity with geometry acquisition. Exp Fluids 55(1):1644CrossRef Im S, Heo GE, Jeon YJ, Sung HJ, Kim SK (2014) Tomographic PIV measurements of flow patterns in a nasal cavity with geometry acquisition. Exp Fluids 55(1):1644CrossRef
go back to reference Jia L, Wang L, Wei F, Yu H, Dong H, Wang B, Lu Z, Sun G, Chen H, Meng J et al (2015) Effects of wall shear stress in venous neointimal hyperplasia of arteriovenous fistulae. Nephrology 20(5):335–342CrossRef Jia L, Wang L, Wei F, Yu H, Dong H, Wang B, Lu Z, Sun G, Chen H, Meng J et al (2015) Effects of wall shear stress in venous neointimal hyperplasia of arteriovenous fistulae. Nephrology 20(5):335–342CrossRef
go back to reference Kakisis JD, Avgerinos E, Giannakopoulos T, Moulakakis K, Papapetrou A, Liapis CD (2012) Balloon angioplasty vs nitinol stent placement in the treatment of venous anastomotic stenoses of hemodialysis grafts after surgical thrombectomy. J Vasc Surg 55(2):472–478CrossRef Kakisis JD, Avgerinos E, Giannakopoulos T, Moulakakis K, Papapetrou A, Liapis CD (2012) Balloon angioplasty vs nitinol stent placement in the treatment of venous anastomotic stenoses of hemodialysis grafts after surgical thrombectomy. J Vasc Surg 55(2):472–478CrossRef
go back to reference Kharboutly Z, Deplano V, Bertrand E, Legallais C (2010) Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis. Med Eng Phys 32(2):111–118CrossRef Kharboutly Z, Deplano V, Bertrand E, Legallais C (2010) Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis. Med Eng Phys 32(2):111–118CrossRef
go back to reference Konner K, Nonnast-Daniel B, Ritz E (2003) The arteriovenous fistula. J Am Soc Nephrol 14(6):1669–1680CrossRef Konner K, Nonnast-Daniel B, Ritz E (2003) The arteriovenous fistula. J Am Soc Nephrol 14(6):1669–1680CrossRef
go back to reference Lee J, Kim S, Kim SM, Song R, Kim HK, Park JS, Park SC (2016) Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application. J Vasc Access 17(6):512–520CrossRef Lee J, Kim S, Kim SM, Song R, Kim HK, Park JS, Park SC (2016) Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application. J Vasc Access 17(6):512–520CrossRef
go back to reference Lwin N, Wahab M, Carroll J, Barber T (2014) Experimental and computational analysis of a typical arterio-venous fistula. In: 19th Australasian fluid mechanics conference, December, 2014 Lwin N, Wahab M, Carroll J, Barber T (2014) Experimental and computational analysis of a typical arterio-venous fistula. In: 19th Australasian fluid mechanics conference, December, 2014
go back to reference McDonald SP, Russ GR (2002) Survival of recipients of cadaveric kidney transplants compared with those receiving dialysis treatment in Australia and New Zealand, 1991–2001. Nephrol Dial Transplant 17(12):2212–2219CrossRef McDonald SP, Russ GR (2002) Survival of recipients of cadaveric kidney transplants compared with those receiving dialysis treatment in Australia and New Zealand, 1991–2001. Nephrol Dial Transplant 17(12):2212–2219CrossRef
go back to reference McGah PM, Leotta DF, Beach KW, Aliseda A (2014) Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula. Biomech Model Mechanobiol 13(3):679–695CrossRef McGah PM, Leotta DF, Beach KW, Aliseda A (2014) Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula. Biomech Model Mechanobiol 13(3):679–695CrossRef
go back to reference Roy-Chaudhury P, Sukhatme VP, Cheung AK (2006) Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol 17(4):1112–1127CrossRef Roy-Chaudhury P, Sukhatme VP, Cheung AK (2006) Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol 17(4):1112–1127CrossRef
go back to reference Scarano F (2012) Tomographic PIV: principles and practice. Meas Sci Technol 24(1):012001CrossRef Scarano F (2012) Tomographic PIV: principles and practice. Meas Sci Technol 24(1):012001CrossRef
go back to reference Sivanesan S, How T, Black R, Bakran A (1999) Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study. J Biomech 32(9):915–925CrossRef Sivanesan S, How T, Black R, Bakran A (1999) Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study. J Biomech 32(9):915–925CrossRef
go back to reference Stella S, Vergara C, Giovannacci L, Quarteroni A, Prouse G (2019) Assessing the disturbed flow and the transition to turbulence in the arteriovenous fistula. J Biomech Eng 141(10):101010CrossRef Stella S, Vergara C, Giovannacci L, Quarteroni A, Prouse G (2019) Assessing the disturbed flow and the transition to turbulence in the arteriovenous fistula. J Biomech Eng 141(10):101010CrossRef
go back to reference Stolic R (2013) Most important chronic complications of arteriovenous fistulas for hemodialysis. Med Princip Pract 22(3):220–228CrossRef Stolic R (2013) Most important chronic complications of arteriovenous fistulas for hemodialysis. Med Princip Pract 22(3):220–228CrossRef
go back to reference Suqin L, Mingli Z, Shiteng S, Honglan M, Lan Z, Qihong N, Qing L (2020) Assessment of the hemodynamics of autogenous arteriovenous fistulas with 4d phase contrast-based flow quantification MRI in dialysis patients. J Magn Reson Imaging 51(4):1272–1280CrossRef Suqin L, Mingli Z, Shiteng S, Honglan M, Lan Z, Qihong N, Qing L (2020) Assessment of the hemodynamics of autogenous arteriovenous fistulas with 4d phase contrast-based flow quantification MRI in dialysis patients. J Magn Reson Imaging 51(4):1272–1280CrossRef
go back to reference Swinnen J, Tan KL, Allen R, Burgess D, Mohan IV (2015) Juxta-anastomotic stenting with aggressive angioplasty will salvage the native radiocephalic fistula for dialysis. J Vasc Surg 61(2):436–442CrossRef Swinnen J, Tan KL, Allen R, Burgess D, Mohan IV (2015) Juxta-anastomotic stenting with aggressive angioplasty will salvage the native radiocephalic fistula for dialysis. J Vasc Surg 61(2):436–442CrossRef
go back to reference Tessitore N, Mansueto G, Lipari G, Bedogna V, Tardivo S, Baggio E, Cenzi D, Carbognin G, Poli A, Lupo A (2006) Endovascular versus surgical preemptive repair of forearm arteriovenous fistula juxta-anastomotic stenosis: analysis of data collected prospectively from 1999 to 2004. Clin J Am Soc Nephrol 1(3):448–454CrossRef Tessitore N, Mansueto G, Lipari G, Bedogna V, Tardivo S, Baggio E, Cenzi D, Carbognin G, Poli A, Lupo A (2006) Endovascular versus surgical preemptive repair of forearm arteriovenous fistula juxta-anastomotic stenosis: analysis of data collected prospectively from 1999 to 2004. Clin J Am Soc Nephrol 1(3):448–454CrossRef
go back to reference Thomas SD, Peden S, Crowe P, Varcoe RL (2019) Interwoven nitinol stents to treat radiocephalic anastomotic arteriovenous fistula stenosis. J Endovasc Ther 26(3):394–401CrossRef Thomas SD, Peden S, Crowe P, Varcoe RL (2019) Interwoven nitinol stents to treat radiocephalic anastomotic arteriovenous fistula stenosis. J Endovasc Ther 26(3):394–401CrossRef
go back to reference TSANZ (2019) Clinical guidelines for organ transplantation from deceased donors. Technical report 1.3, The Transplantation Society of Australia and New Zealand TSANZ (2019) Clinical guidelines for organ transplantation from deceased donors. Technical report 1.3, The Transplantation Society of Australia and New Zealand
go back to reference Vijayaratnam PR, O’Brien CC, Reizes JA, Barber TJ, Edelman ER (2015) The impact of blood rheology on drug transport in stented arteries: steady simulations. PLoS One 10(6):e0128178CrossRef Vijayaratnam PR, O’Brien CC, Reizes JA, Barber TJ, Edelman ER (2015) The impact of blood rheology on drug transport in stented arteries: steady simulations. PLoS One 10(6):e0128178CrossRef
go back to reference Westerweel J, Scarano F (2005) Universal outlier detection for PIV data. Exp Fluids 39(6):1096–1100CrossRef Westerweel J, Scarano F (2005) Universal outlier detection for PIV data. Exp Fluids 39(6):1096–1100CrossRef
go back to reference Wieneke B (2008) Volume self-calibration for 3d particle image velocimetry. Exp Fluids 45(4):549–556CrossRef Wieneke B (2008) Volume self-calibration for 3d particle image velocimetry. Exp Fluids 45(4):549–556CrossRef
go back to reference Wieneke B (2018) Improvements for volume self-calibration. Meas Sci Technol 29(8):084002CrossRef Wieneke B (2018) Improvements for volume self-calibration. Meas Sci Technol 29(8):084002CrossRef
Metadata
Title
Tomographic PIV analysis of physiological flow conditions in a patient-specific arteriovenous fistula
Authors
Sanjiv Gunasekera
Olivia Ng
Shannon Thomas
Ramon Varcoe
Charitha de Silva
Tracie Barber
Publication date
01-12-2020
Publisher
Springer Berlin Heidelberg
Published in
Experiments in Fluids / Issue 12/2020
Print ISSN: 0723-4864
Electronic ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-020-03085-4

Other articles of this Issue 12/2020

Experiments in Fluids 12/2020 Go to the issue

Premium Partners