Skip to main content
Erschienen in: Experiments in Fluids 12/2020

01.12.2020 | Research Article

Tomographic PIV analysis of physiological flow conditions in a patient-specific arteriovenous fistula

verfasst von: Sanjiv Gunasekera, Olivia Ng, Shannon Thomas, Ramon Varcoe, Charitha de Silva, Tracie Barber

Erschienen in: Experiments in Fluids | Ausgabe 12/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The arteriovenous fistula (AVF), which is a vasculature created for end-stage renal disease patients who require haemodialysis, is susceptible to many vascular diseases. It is well known that disturbed hemodynamics is a factor in the initiation of vascular disease; however, only a limited number of experimental studies have been conducted to assess the flow behaviour within the AVF. The current study is an investigation of the complex three-dimensional flow within a physiological AVF geometry, using tomographic particle image velocimetry. To this end, a benchtop model of a patient-specific geometry was created by casting silicone around a soluble 3D print of the vessels. The patient-specific boundary conditions were reproduced by driving a refractive-index matched working fluid from a pulsatile pump, which was connected to the model via a tubing network inclusive of valves and compliance chambers. The seeded working fluid was illuminated with a 1 kHz double-pulsed laser, and four high-speed cameras placed at optimised locations were used to capture the particle images, with the volume reconstructions refined by a 3D internal mask created using morphological operations. The velocity magnitude contour plots of the resulting vector field revealed two zones of low velocity in the anastomosis, while locations of high turbulent kinetic energy are observed in the anastomosis and venous regions. These results suggested that the collision of the two opposing inlet flows and the curvature at the anastomosis cause disturbance in the flow that is carried downstream.

Graphic abstract

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Al-Jaishi AA, Liu AR, Lok CE, Zhang JC, Moist LM (2017) Complications of the arteriovenous fistula: a systematic review. J Am Soc Nephrol 28(6):1839–1850CrossRef Al-Jaishi AA, Liu AR, Lok CE, Zhang JC, Moist LM (2017) Complications of the arteriovenous fistula: a systematic review. J Am Soc Nephrol 28(6):1839–1850CrossRef
Zurück zum Zitat Botti L, Van Canneyt K, Kaminsky R, Claessens T, Planken RN, Verdonck P, Remuzzi A, Antiga L (2013) Numerical evaluation and experimental validation of pressure drops across a patient-specific model of vascular access for hemodialysis. Cardiovasc Eng Technol 4(4):485–499CrossRef Botti L, Van Canneyt K, Kaminsky R, Claessens T, Planken RN, Verdonck P, Remuzzi A, Antiga L (2013) Numerical evaluation and experimental validation of pressure drops across a patient-specific model of vascular access for hemodialysis. Cardiovasc Eng Technol 4(4):485–499CrossRef
Zurück zum Zitat Buchmann N, Atkinson C, Jeremy M, Soria J (2011) Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation. Exp Fluids 50(4):1131–1151CrossRef Buchmann N, Atkinson C, Jeremy M, Soria J (2011) Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation. Exp Fluids 50(4):1131–1151CrossRef
Zurück zum Zitat Carroll J, Varcoe RL, Barber T, Simmons A (2019) Reduction in anastomotic flow disturbance within a modified end-to-side arteriovenous fistula configuration: results of a computational flow dynamic model. Nephrology 24(2):245–251CrossRef Carroll J, Varcoe RL, Barber T, Simmons A (2019) Reduction in anastomotic flow disturbance within a modified end-to-side arteriovenous fistula configuration: results of a computational flow dynamic model. Nephrology 24(2):245–251CrossRef
Zurück zum Zitat Carroll JE, Colley ES, Thomas SD, Varcoe RL, Simmons A, Barber TJ (2020) Tracking geometric and hemodynamic alterations of an arteriovenous fistula through patient-specific modelling. Comput Methods Programs Biomed 186:105203CrossRef Carroll JE, Colley ES, Thomas SD, Varcoe RL, Simmons A, Barber TJ (2020) Tracking geometric and hemodynamic alterations of an arteriovenous fistula through patient-specific modelling. Comput Methods Programs Biomed 186:105203CrossRef
Zurück zum Zitat Colley E, Carroll J, Thomas S, Varcoe RL, Simmons A, Barber T (2018) A methodology for non-invasive 3-d surveillance of arteriovenous fistulae using freehand ultrasound. IEEE Trans Biomed Eng 65(8):1885–1891CrossRef Colley E, Carroll J, Thomas S, Varcoe RL, Simmons A, Barber T (2018) A methodology for non-invasive 3-d surveillance of arteriovenous fistulae using freehand ultrasound. IEEE Trans Biomed Eng 65(8):1885–1891CrossRef
Zurück zum Zitat De Silva C, Baidya R, Khashehchi M, Marusic I (2012) Assessment of tomographic PIV in wall-bounded turbulence using direct numerical simulation data. Exp Fluids 52(2):425–440CrossRef De Silva C, Baidya R, Khashehchi M, Marusic I (2012) Assessment of tomographic PIV in wall-bounded turbulence using direct numerical simulation data. Exp Fluids 52(2):425–440CrossRef
Zurück zum Zitat Decorato I, Kharboutly Z, Vassallo T, Penrose J, Legallais C, Salsac AV (2014) Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula. Int J Numer Methods Biomed Eng 30(2):143–159CrossRef Decorato I, Kharboutly Z, Vassallo T, Penrose J, Legallais C, Salsac AV (2014) Numerical simulation of the fluid structure interactions in a compliant patient-specific arteriovenous fistula. Int J Numer Methods Biomed Eng 30(2):143–159CrossRef
Zurück zum Zitat Duque JC, Tabbara M, Martinez L, Cardona J, Vazquez-Padron RI, Salman LH (2017) Dialysis arteriovenous fistula failure and angioplasty: intimal hyperplasia and other causes of access failure. Am J Kidney Dis 69(1):147–151CrossRef Duque JC, Tabbara M, Martinez L, Cardona J, Vazquez-Padron RI, Salman LH (2017) Dialysis arteriovenous fistula failure and angioplasty: intimal hyperplasia and other causes of access failure. Am J Kidney Dis 69(1):147–151CrossRef
Zurück zum Zitat Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41(6):933–947CrossRef Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41(6):933–947CrossRef
Zurück zum Zitat Ene-Iordache B, Remuzzi A (2017) Blood flow in idealized vascular access for hemodialysis: a review of computational studies. Cardiovasc Eng Technol 8(3):295–312CrossRef Ene-Iordache B, Remuzzi A (2017) Blood flow in idealized vascular access for hemodialysis: a review of computational studies. Cardiovasc Eng Technol 8(3):295–312CrossRef
Zurück zum Zitat Fulker D, Ene-Iordache B, Barber T (2018) High-resolution computational fluid dynamic simulation of haemodialysis cannulation in a patient-specific arteriovenous fistula. J Biomech Eng 140(3):031011CrossRef Fulker D, Ene-Iordache B, Barber T (2018) High-resolution computational fluid dynamic simulation of haemodialysis cannulation in a patient-specific arteriovenous fistula. J Biomech Eng 140(3):031011CrossRef
Zurück zum Zitat Gimbrone MA Jr, García-Cardeña G (2016) Endothelial cell dysfunction and the pathobiology of atherosclerosis. Circ Res 118(4):620–636CrossRef Gimbrone MA Jr, García-Cardeña G (2016) Endothelial cell dysfunction and the pathobiology of atherosclerosis. Circ Res 118(4):620–636CrossRef
Zurück zum Zitat Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2019) Towards 3d PIV measurements of a patient-specific arteriovenous fistula. In: Alwahabi Z, Medwell P (eds) Proceedings of the 9th Australian conference on laser diagnostics. University of Adelaide, pp 87–90 Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2019) Towards 3d PIV measurements of a patient-specific arteriovenous fistula. In: Alwahabi Z, Medwell P (eds) Proceedings of the 9th Australian conference on laser diagnostics. University of Adelaide, pp 87–90
Zurück zum Zitat He Y, Shiu YT, Pike DB, Roy-Chaudhury P, Cheung AK, Berceli SA (2018) Comparison of hemodialysis arteriovenous fistula blood flow rates measured by doppler ultrasound and phase-contrast magnetic resonance imaging. J Vasc Surg 68(6):1848–1857CrossRef He Y, Shiu YT, Pike DB, Roy-Chaudhury P, Cheung AK, Berceli SA (2018) Comparison of hemodialysis arteriovenous fistula blood flow rates measured by doppler ultrasound and phase-contrast magnetic resonance imaging. J Vasc Surg 68(6):1848–1857CrossRef
Zurück zum Zitat Im S, Heo GE, Jeon YJ, Sung HJ, Kim SK (2014) Tomographic PIV measurements of flow patterns in a nasal cavity with geometry acquisition. Exp Fluids 55(1):1644CrossRef Im S, Heo GE, Jeon YJ, Sung HJ, Kim SK (2014) Tomographic PIV measurements of flow patterns in a nasal cavity with geometry acquisition. Exp Fluids 55(1):1644CrossRef
Zurück zum Zitat Jia L, Wang L, Wei F, Yu H, Dong H, Wang B, Lu Z, Sun G, Chen H, Meng J et al (2015) Effects of wall shear stress in venous neointimal hyperplasia of arteriovenous fistulae. Nephrology 20(5):335–342CrossRef Jia L, Wang L, Wei F, Yu H, Dong H, Wang B, Lu Z, Sun G, Chen H, Meng J et al (2015) Effects of wall shear stress in venous neointimal hyperplasia of arteriovenous fistulae. Nephrology 20(5):335–342CrossRef
Zurück zum Zitat Kakisis JD, Avgerinos E, Giannakopoulos T, Moulakakis K, Papapetrou A, Liapis CD (2012) Balloon angioplasty vs nitinol stent placement in the treatment of venous anastomotic stenoses of hemodialysis grafts after surgical thrombectomy. J Vasc Surg 55(2):472–478CrossRef Kakisis JD, Avgerinos E, Giannakopoulos T, Moulakakis K, Papapetrou A, Liapis CD (2012) Balloon angioplasty vs nitinol stent placement in the treatment of venous anastomotic stenoses of hemodialysis grafts after surgical thrombectomy. J Vasc Surg 55(2):472–478CrossRef
Zurück zum Zitat Kharboutly Z, Deplano V, Bertrand E, Legallais C (2010) Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis. Med Eng Phys 32(2):111–118CrossRef Kharboutly Z, Deplano V, Bertrand E, Legallais C (2010) Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysis. Med Eng Phys 32(2):111–118CrossRef
Zurück zum Zitat Konner K, Nonnast-Daniel B, Ritz E (2003) The arteriovenous fistula. J Am Soc Nephrol 14(6):1669–1680CrossRef Konner K, Nonnast-Daniel B, Ritz E (2003) The arteriovenous fistula. J Am Soc Nephrol 14(6):1669–1680CrossRef
Zurück zum Zitat Lee J, Kim S, Kim SM, Song R, Kim HK, Park JS, Park SC (2016) Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application. J Vasc Access 17(6):512–520CrossRef Lee J, Kim S, Kim SM, Song R, Kim HK, Park JS, Park SC (2016) Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application. J Vasc Access 17(6):512–520CrossRef
Zurück zum Zitat Lwin N, Wahab M, Carroll J, Barber T (2014) Experimental and computational analysis of a typical arterio-venous fistula. In: 19th Australasian fluid mechanics conference, December, 2014 Lwin N, Wahab M, Carroll J, Barber T (2014) Experimental and computational analysis of a typical arterio-venous fistula. In: 19th Australasian fluid mechanics conference, December, 2014
Zurück zum Zitat McDonald SP, Russ GR (2002) Survival of recipients of cadaveric kidney transplants compared with those receiving dialysis treatment in Australia and New Zealand, 1991–2001. Nephrol Dial Transplant 17(12):2212–2219CrossRef McDonald SP, Russ GR (2002) Survival of recipients of cadaveric kidney transplants compared with those receiving dialysis treatment in Australia and New Zealand, 1991–2001. Nephrol Dial Transplant 17(12):2212–2219CrossRef
Zurück zum Zitat McGah PM, Leotta DF, Beach KW, Aliseda A (2014) Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula. Biomech Model Mechanobiol 13(3):679–695CrossRef McGah PM, Leotta DF, Beach KW, Aliseda A (2014) Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula. Biomech Model Mechanobiol 13(3):679–695CrossRef
Zurück zum Zitat Roy-Chaudhury P, Sukhatme VP, Cheung AK (2006) Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol 17(4):1112–1127CrossRef Roy-Chaudhury P, Sukhatme VP, Cheung AK (2006) Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol 17(4):1112–1127CrossRef
Zurück zum Zitat Scarano F (2012) Tomographic PIV: principles and practice. Meas Sci Technol 24(1):012001CrossRef Scarano F (2012) Tomographic PIV: principles and practice. Meas Sci Technol 24(1):012001CrossRef
Zurück zum Zitat Sivanesan S, How T, Black R, Bakran A (1999) Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study. J Biomech 32(9):915–925CrossRef Sivanesan S, How T, Black R, Bakran A (1999) Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study. J Biomech 32(9):915–925CrossRef
Zurück zum Zitat Stella S, Vergara C, Giovannacci L, Quarteroni A, Prouse G (2019) Assessing the disturbed flow and the transition to turbulence in the arteriovenous fistula. J Biomech Eng 141(10):101010CrossRef Stella S, Vergara C, Giovannacci L, Quarteroni A, Prouse G (2019) Assessing the disturbed flow and the transition to turbulence in the arteriovenous fistula. J Biomech Eng 141(10):101010CrossRef
Zurück zum Zitat Stolic R (2013) Most important chronic complications of arteriovenous fistulas for hemodialysis. Med Princip Pract 22(3):220–228CrossRef Stolic R (2013) Most important chronic complications of arteriovenous fistulas for hemodialysis. Med Princip Pract 22(3):220–228CrossRef
Zurück zum Zitat Suqin L, Mingli Z, Shiteng S, Honglan M, Lan Z, Qihong N, Qing L (2020) Assessment of the hemodynamics of autogenous arteriovenous fistulas with 4d phase contrast-based flow quantification MRI in dialysis patients. J Magn Reson Imaging 51(4):1272–1280CrossRef Suqin L, Mingli Z, Shiteng S, Honglan M, Lan Z, Qihong N, Qing L (2020) Assessment of the hemodynamics of autogenous arteriovenous fistulas with 4d phase contrast-based flow quantification MRI in dialysis patients. J Magn Reson Imaging 51(4):1272–1280CrossRef
Zurück zum Zitat Swinnen J, Tan KL, Allen R, Burgess D, Mohan IV (2015) Juxta-anastomotic stenting with aggressive angioplasty will salvage the native radiocephalic fistula for dialysis. J Vasc Surg 61(2):436–442CrossRef Swinnen J, Tan KL, Allen R, Burgess D, Mohan IV (2015) Juxta-anastomotic stenting with aggressive angioplasty will salvage the native radiocephalic fistula for dialysis. J Vasc Surg 61(2):436–442CrossRef
Zurück zum Zitat Tessitore N, Mansueto G, Lipari G, Bedogna V, Tardivo S, Baggio E, Cenzi D, Carbognin G, Poli A, Lupo A (2006) Endovascular versus surgical preemptive repair of forearm arteriovenous fistula juxta-anastomotic stenosis: analysis of data collected prospectively from 1999 to 2004. Clin J Am Soc Nephrol 1(3):448–454CrossRef Tessitore N, Mansueto G, Lipari G, Bedogna V, Tardivo S, Baggio E, Cenzi D, Carbognin G, Poli A, Lupo A (2006) Endovascular versus surgical preemptive repair of forearm arteriovenous fistula juxta-anastomotic stenosis: analysis of data collected prospectively from 1999 to 2004. Clin J Am Soc Nephrol 1(3):448–454CrossRef
Zurück zum Zitat Thomas SD, Peden S, Crowe P, Varcoe RL (2019) Interwoven nitinol stents to treat radiocephalic anastomotic arteriovenous fistula stenosis. J Endovasc Ther 26(3):394–401CrossRef Thomas SD, Peden S, Crowe P, Varcoe RL (2019) Interwoven nitinol stents to treat radiocephalic anastomotic arteriovenous fistula stenosis. J Endovasc Ther 26(3):394–401CrossRef
Zurück zum Zitat TSANZ (2019) Clinical guidelines for organ transplantation from deceased donors. Technical report 1.3, The Transplantation Society of Australia and New Zealand TSANZ (2019) Clinical guidelines for organ transplantation from deceased donors. Technical report 1.3, The Transplantation Society of Australia and New Zealand
Zurück zum Zitat Vijayaratnam PR, O’Brien CC, Reizes JA, Barber TJ, Edelman ER (2015) The impact of blood rheology on drug transport in stented arteries: steady simulations. PLoS One 10(6):e0128178CrossRef Vijayaratnam PR, O’Brien CC, Reizes JA, Barber TJ, Edelman ER (2015) The impact of blood rheology on drug transport in stented arteries: steady simulations. PLoS One 10(6):e0128178CrossRef
Zurück zum Zitat Westerweel J, Scarano F (2005) Universal outlier detection for PIV data. Exp Fluids 39(6):1096–1100CrossRef Westerweel J, Scarano F (2005) Universal outlier detection for PIV data. Exp Fluids 39(6):1096–1100CrossRef
Zurück zum Zitat Wieneke B (2008) Volume self-calibration for 3d particle image velocimetry. Exp Fluids 45(4):549–556CrossRef Wieneke B (2008) Volume self-calibration for 3d particle image velocimetry. Exp Fluids 45(4):549–556CrossRef
Zurück zum Zitat Wieneke B (2018) Improvements for volume self-calibration. Meas Sci Technol 29(8):084002CrossRef Wieneke B (2018) Improvements for volume self-calibration. Meas Sci Technol 29(8):084002CrossRef
Metadaten
Titel
Tomographic PIV analysis of physiological flow conditions in a patient-specific arteriovenous fistula
verfasst von
Sanjiv Gunasekera
Olivia Ng
Shannon Thomas
Ramon Varcoe
Charitha de Silva
Tracie Barber
Publikationsdatum
01.12.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Experiments in Fluids / Ausgabe 12/2020
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-020-03085-4

Weitere Artikel der Ausgabe 12/2020

Experiments in Fluids 12/2020 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.