Skip to main content
Erschienen in: Experiments in Fluids 4/2008

01.10.2008 | Research Article

Volume self-calibration for 3D particle image velocimetry

verfasst von: B. Wieneke

Erschienen in: Experiments in Fluids | Ausgabe 4/2008

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Planar self-calibration methods have become standard for stereo PIV to correct misalignments between laser light sheet and calibration plane. Computing cross-correlation between images from camera 1 and 2 taken at the same time, non-zero disparity vectors indicate rotational and translational misalignments relative to the coordinate system defined by a calibration plate. This approach works well for thin light sheets but fails for extended volumes recorded in 3D-PTV or tomographic PIV experiments. Here it is primarily necessary to correct calibration errors leading to triangulation errors in 3D-PTV or in degraded tomographic volume reconstruction. Tomographic PIV requires calibration accuracies of a fraction of a pixel throughout the complete volume, which is difficult to achieve experimentally. A new volumetric self-calibration technique has been developed based on the computation of the 3D position of matching particles by triangulation as in 3D-PTV. The residual triangulation error (‘disparity’) is then used to correct the mapping functions for all cameras. A statistical clustering method suitable for dense particle images has been implemented to find correct disparity map peaks from true particle matches. Disparity maps from multiple recordings are summed for better statistics. This self-calibration scheme has been validated using several tomographic PIV experiments improving the vector quality significantly. The relevance for other 3D velocimetry methods is discussed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Brücker Ch (1996) 3-D scanning-particle-image-velocimetry: technique and application to a spherical cap wake flow. Exp Fluids 56:157–179 Brücker Ch (1996) 3-D scanning-particle-image-velocimetry: technique and application to a spherical cap wake flow. Exp Fluids 56:157–179
Zurück zum Zitat Calluaud D, David L (2004) Stereoscopic particle image velocimetry measurements of a flow around a surface-mounted block. Exp Fluids 36:33–61CrossRef Calluaud D, David L (2004) Stereoscopic particle image velocimetry measurements of a flow around a surface-mounted block. Exp Fluids 36:33–61CrossRef
Zurück zum Zitat Coudert S, Schon JP (2001) Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV. Meas Sci Technol 12:1371–1381CrossRef Coudert S, Schon JP (2001) Back-projection algorithm with misalignment corrections for 2D3C stereoscopic PIV. Meas Sci Technol 12:1371–1381CrossRef
Zurück zum Zitat Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41:933–947CrossRef Elsinga GE, Scarano F, Wieneke B, van Oudheusden BW (2006) Tomographic particle image velocimetry. Exp Fluids 41:933–947CrossRef
Zurück zum Zitat Hartley R, Sturm P (1994) Triangulation. ARPA Image Understanding Workshop, Monterey, pp 957–966 Hartley R, Sturm P (1994) Triangulation. ARPA Image Understanding Workshop, Monterey, pp 957–966
Zurück zum Zitat Hori T, Sakakibara J (2004) High speed scanning stereoscopic PIV for 3D vorticity measurement in liquids. Meas Sci Technol 15:1067–1078CrossRef Hori T, Sakakibara J (2004) High speed scanning stereoscopic PIV for 3D vorticity measurement in liquids. Meas Sci Technol 15:1067–1078CrossRef
Zurück zum Zitat Maas HG (1996) Contributions of digital photogrammatry to 3D PTV. In: Dracos T (ed) Three-dimensional velocity and vorticity measuring and image annalysis techniques. Kluwer, Dordrecht, pp 191–208 Maas HG (1996) Contributions of digital photogrammatry to 3D PTV. In: Dracos T (ed) Three-dimensional velocity and vorticity measuring and image annalysis techniques. Kluwer, Dordrecht, pp 191–208
Zurück zum Zitat Michaelis D, Poelma C, Scarano F, Westerweel J, Wieneke B (2006) A 3D time-resolved cylinder wake survey by Tomographic PIV. In: 12th international symposium on flow visualization, Göttingen, Germany, 10–14 September Michaelis D, Poelma C, Scarano F, Westerweel J, Wieneke B (2006) A 3D time-resolved cylinder wake survey by Tomographic PIV. In: 12th international symposium on flow visualization, Göttingen, Germany, 10–14 September
Zurück zum Zitat Prasad A (2000) Stereoscopic particle image velocimetry. Exp Fluids 29:103–116CrossRef Prasad A (2000) Stereoscopic particle image velocimetry. Exp Fluids 29:103–116CrossRef
Zurück zum Zitat Scarano F, David L, Bsibsi M, Calluaud D (2005) S-PIV comparative assessment: image dewarping + misalignment correction and pinhole + geometric back projection. Exp Fluids 39:257–266CrossRef Scarano F, David L, Bsibsi M, Calluaud D (2005) S-PIV comparative assessment: image dewarping + misalignment correction and pinhole + geometric back projection. Exp Fluids 39:257–266CrossRef
Zurück zum Zitat Soloff SM, Adrian RJ, Liu ZC (1997) Distortion compensation for generalized stereoscopic particle image velocimetry. Meas Sci Technol 8:1441–1454CrossRef Soloff SM, Adrian RJ, Liu ZC (1997) Distortion compensation for generalized stereoscopic particle image velocimetry. Meas Sci Technol 8:1441–1454CrossRef
Zurück zum Zitat Westerweel J, Scarano F (2005) A universal detection criterion for the median test. Exp Fluids 39–6, 1096 Westerweel J, Scarano F (2005) A universal detection criterion for the median test. Exp Fluids 39–6, 1096
Zurück zum Zitat Wieneke B (2005) Stereo-PIV using self-calibration on particle images. Exp Fluids 39:267–280CrossRef Wieneke B (2005) Stereo-PIV using self-calibration on particle images. Exp Fluids 39:267–280CrossRef
Zurück zum Zitat Wieneke B, Taylor S (2006) Fat-sheet PIV with computation of full 3D-strain tensor using tomographic reconstruction. In: 13th international symposium on applications of laser techniques to fluid mechanics, Lisbon Wieneke B, Taylor S (2006) Fat-sheet PIV with computation of full 3D-strain tensor using tomographic reconstruction. In: 13th international symposium on applications of laser techniques to fluid mechanics, Lisbon
Zurück zum Zitat Willert C (1997) Stereoscopic digital particle image velocimetry for application in wind tunnel flows. Meas Sci Technol 8:1465–1469CrossRef Willert C (1997) Stereoscopic digital particle image velocimetry for application in wind tunnel flows. Meas Sci Technol 8:1465–1469CrossRef
Metadaten
Titel
Volume self-calibration for 3D particle image velocimetry
verfasst von
B. Wieneke
Publikationsdatum
01.10.2008
Verlag
Springer-Verlag
Erschienen in
Experiments in Fluids / Ausgabe 4/2008
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-008-0521-5

Weitere Artikel der Ausgabe 4/2008

Experiments in Fluids 4/2008 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.