Skip to main content
Top
Published in: Journal of Materials Engineering and Performance 7/2014

01-07-2014

Effect of Surface Alloying by Silicon on the Corrosion Resistance and Biocompatibility of the Binary NiTi

Authors: S. G. Psakhie, S. N. Meisner, A. I. Lotkov, L. L. Meisner, A. V. Tverdokhlebova

Published in: Journal of Materials Engineering and Performance | Issue 7/2014

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

This paper presents the study on changes in element and phase compositions in the near-surface layer and on surface topography of the NiTi specimens after the silicon ion-beam treatment. The effect of these parameters of the near-surface layer on corrosion properties in biochemical solutions and biocompatibility with mesenchymal stem cells of rat marrow is studied. Ion-beam surface modification of the specimens was performed by a DIANA-3 implanter (Tomsk, Russia), using single-ion-beam pulses under oil-free pumping and high vacuum (10−4 Pa) conditions in a high-dose ion implantation regime. The fluence made 2 × 1017 cm−2, at an average accelerating voltage of 60 kV, and pulse repetition frequency of 50 Hz. The silicon ion-beam treatment of specimen surfaces is shown to bring about a nearly twofold improvement in the corrosion resistance of the material to attack by aqueous solutions of NaCl (artificial body fluid) and human plasma and a drastic decrease in the nickel concentration after immersion of the specimens into the solutions for ~3400 and ~6000 h, respectively (for the artificial plasma solution, a nearly 20-fold decrease in the Ni concentration is observed). It is shown that improvement of NiTi corrosion resistance after treatment by Si ions occurs mainly due to the formation of two-layer composite coating based on Ti oxides (outer layer) on the NiTi surface and adjacent inner layer of oxides, carbides, and silicides of the NiTi alloy components. Inner layer with high silicon concentration serves as a barrier layer preventing nickel penetration into biomedium. This, in our opinion, is the main reason why the NiTi alloy exhibits no cytotoxic properties after ion modification of its surface and leads to the biocompatibility improvement at the cellular level, respectively.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference M. Salmerón-Sánchez and G. Altankov, Cell-Protein-Material Interaction in Tissue Engineering, Advances in Regenerative Medicine: Role of Nanotechnology and Engineering Principles, V.P. Shastri, G. Altankov, and A. Lendlein, Ed., Springer, Dordrecht, 2010, p 3–15 M. Salmerón-Sánchez and G. Altankov, Cell-Protein-Material Interaction in Tissue Engineering, Advances in Regenerative Medicine: Role of Nanotechnology and Engineering Principles, V.P. Shastri, G. Altankov, and A. Lendlein, Ed., Springer, Dordrecht, 2010, p 3–15
2.
go back to reference G. Altankov, T. Groth, E. Engel et al., Development of Provisional Extracellular Matrix on Biomaterials Interface: Lessons from In Vitro Cell Culture, Advances in Regenerative Medicine: Role of Nanotechnology and Engineering Principles, V.P. Shastri, G. Altankov, A. Lendlein, Ed., Springer, Dordrecht, 2010, p 19–41 G. Altankov, T. Groth, E. Engel et al., Development of Provisional Extracellular Matrix on Biomaterials Interface: Lessons from In Vitro Cell Culture, Advances in Regenerative Medicine: Role of Nanotechnology and Engineering Principles, V.P. Shastri, G. Altankov, A. Lendlein, Ed., Springer, Dordrecht, 2010, p 19–41
3.
go back to reference G. Mani, M.D. Feldman, D. Patel, and C.M. Agrawal, Coronary Stents: A Materials Perspective, Biomaterials, 2007, 28(9), p 1689–1710CrossRef G. Mani, M.D. Feldman, D. Patel, and C.M. Agrawal, Coronary Stents: A Materials Perspective, Biomaterials, 2007, 28(9), p 1689–1710CrossRef
4.
go back to reference A. Mahapatro, D.M. Johnson, D.N. Patel et al., Surface Modification of Functional Self-Assembled Monolayers on 316L Stainless Steel Via Lipase Catalysis, Langmuir, 2006, 22(3), p 901–905CrossRef A. Mahapatro, D.M. Johnson, D.N. Patel et al., Surface Modification of Functional Self-Assembled Monolayers on 316L Stainless Steel Via Lipase Catalysis, Langmuir, 2006, 22(3), p 901–905CrossRef
5.
go back to reference O.N. Lazarenko, Influence of Coatings on the Stent Thrombosis and Restenosis, Praktikal Angiologiya, 2007, 7(2), p 42–49 [in Russian] O.N. Lazarenko, Influence of Coatings on the Stent Thrombosis and Restenosis, Praktikal Angiologiya, 2007, 7(2), p 42–49 [in Russian]
6.
go back to reference I.I. Kornilov, O.K. Belousov, and E.V. Kachur, Titanium Nickelide and Other Alloys with the Shape Memory Effect, Nauka, Moscow, 1977 [in Russian] I.I. Kornilov, O.K. Belousov, and E.V. Kachur, Titanium Nickelide and Other Alloys with the Shape Memory Effect, Nauka, Moscow, 1977 [in Russian]
7.
go back to reference A.I. Lotkov, V.N. Khachin, V.N. Grishkov et al., Alloys with the Shape Memory Effect, Phys. Mesomech. Comput. Aided Des. Mater., 1995, 2, p 202–213 [in Russian] A.I. Lotkov, V.N. Khachin, V.N. Grishkov et al., Alloys with the Shape Memory Effect, Phys. Mesomech. Comput. Aided Des. Mater., 1995, 2, p 202–213 [in Russian]
8.
go back to reference V.N. Zhuravlev and V.G. Pushin, Alloys with Thermomechanical Memory and Their Application in Medicine, The Urals Branch of the Russian Academy of Sciences, Ekaterinburg, 2000 [in Russian] V.N. Zhuravlev and V.G. Pushin, Alloys with Thermomechanical Memory and Their Application in Medicine, The Urals Branch of the Russian Academy of Sciences, Ekaterinburg, 2000 [in Russian]
9.
go back to reference D. Stoeckel, A. Pelton, and T. Duerig, Self-Expanding Nitinol Stents: Material and Design Considerations, Eur. Radiol., 2004, 2(14), p 292–301CrossRef D. Stoeckel, A. Pelton, and T. Duerig, Self-Expanding Nitinol Stents: Material and Design Considerations, Eur. Radiol., 2004, 2(14), p 292–301CrossRef
10.
go back to reference L.L. Meisner, Mechanical and Physico-chemical Properties of Alloys Based on NiTi Thin Surface Layers Modified by Streams of Charged Particles, Fiz. Mesomekh., 2004, 7(2), p 169–172 [in Russian] L.L. Meisner, Mechanical and Physico-chemical Properties of Alloys Based on NiTi Thin Surface Layers Modified by Streams of Charged Particles, Fiz. Mesomekh., 2004, 7(2), p 169–172 [in Russian]
11.
go back to reference A.I. Lotkov, L.L. Meisner, and V.N. Grishkov, Alloys Based on NiTi: Ion-Beam, Plasma and Chemical Surface Modification, Fiz. Met. Metalloved., 2005, 99(2), p 1–13 [in Russian] A.I. Lotkov, L.L. Meisner, and V.N. Grishkov, Alloys Based on NiTi: Ion-Beam, Plasma and Chemical Surface Modification, Fiz. Met. Metalloved., 2005, 99(2), p 1–13 [in Russian]
12.
go back to reference L.L. Meisner, A.I. Lotkov, V.A. Matveeva et al., Effect of Silicon, Titanium, Zirconium Ion Implantation on NiTi Biocompatibility, Adv. Mater. Sci. Eng., 2012, 2012, p 1–16CrossRef L.L. Meisner, A.I. Lotkov, V.A. Matveeva et al., Effect of Silicon, Titanium, Zirconium Ion Implantation on NiTi Biocompatibility, Adv. Mater. Sci. Eng., 2012, 2012, p 1–16CrossRef
13.
go back to reference L.L. Meisner, V.A. Matveeva, A.I. Lotkov et al., Effect of Ion Alloying Silicon, Titanium, Zirconium Surface Layers of NiTi on the Cytotoxicity and Proliferation of Mesenchymal Stem Cells, Izv. Vysshikh Uchebn. Zaved. Fizika, 2011, 54(9), p 39–51 [in Russian] L.L. Meisner, V.A. Matveeva, A.I. Lotkov et al., Effect of Ion Alloying Silicon, Titanium, Zirconium Surface Layers of NiTi on the Cytotoxicity and Proliferation of Mesenchymal Stem Cells, Izv. Vysshikh Uchebn. Zaved. Fizika, 2011, 54(9), p 39–51 [in Russian]
14.
go back to reference Z. Jiang, X. Dai, and H. Middleton, Effect of Silicon on Corrosion Resistance of Ti-Si Alloys, Mater. Sci. Eng. B, 2011, 176(1), p 79–86CrossRef Z. Jiang, X. Dai, and H. Middleton, Effect of Silicon on Corrosion Resistance of Ti-Si Alloys, Mater. Sci. Eng. B, 2011, 176(1), p 79–86CrossRef
15.
go back to reference B. Kaur, K. Singh, and O.P. Pandey, Corrosion Study of SiO2-CaO-Al2O3-Na2O-TiO2 Glass Coating on Steel, Surf. Eng., 2013, 29(6), p 479–483CrossRef B. Kaur, K. Singh, and O.P. Pandey, Corrosion Study of SiO2-CaO-Al2O3-Na2O-TiO2 Glass Coating on Steel, Surf. Eng., 2013, 29(6), p 479–483CrossRef
16.
go back to reference H. Shi et al., Characterization of Protective Performance of Epoxy Reinforced with Nanometer-Sized TiO2 and SiO2, Prog. Org. Coat., 2008, 62(4), p 359–368CrossRef H. Shi et al., Characterization of Protective Performance of Epoxy Reinforced with Nanometer-Sized TiO2 and SiO2, Prog. Org. Coat., 2008, 62(4), p 359–368CrossRef
17.
go back to reference J. Liu et al., Improved Corrosion Resistance of NiTi Alloy by Coated with TiO2-SiO2-HAP Composite Films, Adv. Mater. Res., 2013, 634, p 996–1000CrossRef J. Liu et al., Improved Corrosion Resistance of NiTi Alloy by Coated with TiO2-SiO2-HAP Composite Films, Adv. Mater. Res., 2013, 634, p 996–1000CrossRef
18.
go back to reference K. Liu and L. Jiang, Metallic Surfaces with Special Wettability, Nanoscale, 2011, 3(3), p 825–838CrossRef K. Liu and L. Jiang, Metallic Surfaces with Special Wettability, Nanoscale, 2011, 3(3), p 825–838CrossRef
19.
go back to reference L.K. Adams, D.Y. Lyon, and P.J.J. Alvarez, Comparative Eco-toxicity of Nanoscale TiO2, SiO2, and ZnO Water Suspensions, Water Res., 2006, 40(19), p 3527–3532CrossRef L.K. Adams, D.Y. Lyon, and P.J.J. Alvarez, Comparative Eco-toxicity of Nanoscale TiO2, SiO2, and ZnO Water Suspensions, Water Res., 2006, 40(19), p 3527–3532CrossRef
20.
go back to reference C.Y. Zheng et al., Enhanced Corrosion Resistance and Cellular Behavior of Ultrafine-Grained Biomedical NiTi Alloy with a Novel SrO-SiO2-TiO2 sol-gel Coating, Appl. Surf. Sci., 2011, 257(13), p 5913–5918CrossRef C.Y. Zheng et al., Enhanced Corrosion Resistance and Cellular Behavior of Ultrafine-Grained Biomedical NiTi Alloy with a Novel SrO-SiO2-TiO2 sol-gel Coating, Appl. Surf. Sci., 2011, 257(13), p 5913–5918CrossRef
21.
go back to reference E.V. Vladimirskaya, O.A. Mayorova, S.A. Rumyantsev, and A.G. Rumyantsev, Biological Fundamentals and Prospects of Stem Cell Therapy, Medpraktika, Moscow, 2005, p 74–102 [in Russian] E.V. Vladimirskaya, O.A. Mayorova, S.A. Rumyantsev, and A.G. Rumyantsev, Biological Fundamentals and Prospects of Stem Cell Therapy, Medpraktika, Moscow, 2005, p 74–102 [in Russian]
22.
go back to reference F.M. Shemyakin, A.N. Karpov, and A.N. Brusen, Analytical Chemistry, Vysshaya Shkola, Moscow, 1965 [in Russian] F.M. Shemyakin, A.N. Karpov, and A.N. Brusen, Analytical Chemistry, Vysshaya Shkola, Moscow, 1965 [in Russian]
23.
go back to reference GOST-R ISO 10993-15-2009 Medical devices. Biological Evaluation of Medical Devices. Part 15. Identification and Quantification of Degradation Products from Metals and Alloys—M., Standartinform, 2010, p. 16. GOST-R ISO 10993-15-2009 Medical devices. Biological Evaluation of Medical Devices. Part 15. Identification and Quantification of Degradation Products from Metals and Alloys—M., Standartinform, 2010, p. 16.
24.
go back to reference A. Felmy, D. Girvin, and E. Jenne, MINTEQ: A Computer Program for Calculating Aqueous Geochemical Equilibria, US Environmental Protection Agency, Washington, DC, 1984, p 98 A. Felmy, D. Girvin, and E. Jenne, MINTEQ: A Computer Program for Calculating Aqueous Geochemical Equilibria, US Environmental Protection Agency, Washington, DC, 1984, p 98
25.
go back to reference V.P. Shakhov, I.A. Khlusov, G.Ts. Dambaev et al., Introduction to Methods of Cell Culture and Organ and Tissue Bioengineering, STT, Tomsk, 2004, p 340–349 [in Russian] V.P. Shakhov, I.A. Khlusov, G.Ts. Dambaev et al., Introduction to Methods of Cell Culture and Organ and Tissue Bioengineering, STT, Tomsk, 2004, p 340–349 [in Russian]
26.
go back to reference T. Mosmann, Rapid Colorimetric Assay for Cellular Growth and Survival: Application to Proliferation and Cytotoxicity Assays, J. Immunol. Methods, 1983, 65, p 55–63CrossRef T. Mosmann, Rapid Colorimetric Assay for Cellular Growth and Survival: Application to Proliferation and Cytotoxicity Assays, J. Immunol. Methods, 1983, 65, p 55–63CrossRef
27.
go back to reference N.A. Plokhinskii, Biometry, MGU Press, Moscow, 1970 [in Russian] N.A. Plokhinskii, Biometry, MGU Press, Moscow, 1970 [in Russian]
28.
go back to reference B.D. Ratner and A.S. Hoffman, Physicochemical Surface Modification of Materials Used in Medicine, Biomaterials Science: an Introduction to Materials in Medicine, 2nd ed., B.D. Ratner et al., Ed., Elsevier Academic Press, London, UK, 2004, p 201–218 B.D. Ratner and A.S. Hoffman, Physicochemical Surface Modification of Materials Used in Medicine, Biomaterials Science: an Introduction to Materials in Medicine, 2nd ed., B.D. Ratner et al., Ed., Elsevier Academic Press, London, UK, 2004, p 201–218
29.
go back to reference A.G. Akimov, On the Laws of Formation of Protective Oxide Layers in the Systems of Metal (Alloy)—Environment, Zashchita Met., 1986, 22(6), p 879–886 [in Russian] A.G. Akimov, On the Laws of Formation of Protective Oxide Layers in the Systems of Metal (Alloy)—Environment, Zashchita Met., 1986, 22(6), p 879–886 [in Russian]
30.
go back to reference T.N. Ustinskaya, N.D. Tomashov, and E.N. Lubnik, The Composition and Electrochemical Properties of the Protective Anode Film on the Intermetallic NiTi, Elektrokhimiya, 1987, 23, p 254–259 [in Russian] T.N. Ustinskaya, N.D. Tomashov, and E.N. Lubnik, The Composition and Electrochemical Properties of the Protective Anode Film on the Intermetallic NiTi, Elektrokhimiya, 1987, 23, p 254–259 [in Russian]
31.
go back to reference L.L. Meisner, V.P. Sivokha, A.I. Lotkov, and E.G. Barmina, Corrosion Properties of Quasi-binary Alloys Cut TiNi-TiAu in Biochemical Solutions, Fiz. Khim. Obrab. Mater., 2006, 1, p 78–84 [in Russian] L.L. Meisner, V.P. Sivokha, A.I. Lotkov, and E.G. Barmina, Corrosion Properties of Quasi-binary Alloys Cut TiNi-TiAu in Biochemical Solutions, Fiz. Khim. Obrab. Mater., 2006, 1, p 78–84 [in Russian]
32.
go back to reference S.A. Shabalovskaya, T. He, J.W. Andregg et al., The Influence of Surface Oxides on the Distribution and Release of Nickel from Nitinol Wires, Biomaterials, 2009, 30(4), p 468–477CrossRef S.A. Shabalovskaya, T. He, J.W. Andregg et al., The Influence of Surface Oxides on the Distribution and Release of Nickel from Nitinol Wires, Biomaterials, 2009, 30(4), p 468–477CrossRef
33.
go back to reference S.A. Firstov, S.V. Tkachenko, and N.N. Kuzmenko, Titanium “Irons” and Titanium “Steel”, Metalloved. Termich. Obrab. Met., 2009, 1, p 14–20 [in Russian] S.A. Firstov, S.V. Tkachenko, and N.N. Kuzmenko, Titanium “Irons” and Titanium “Steel”, Metalloved. Termich. Obrab. Met., 2009, 1, p 14–20 [in Russian]
34.
go back to reference J.L. Murray, The Si-Ti (Silicon-Titanium) System, Phase Diagrams of Binary Titanium Alloys, J.L. Murray, Ed., ASM, Materials Park, 1987, p 289–293 J.L. Murray, The Si-Ti (Silicon-Titanium) System, Phase Diagrams of Binary Titanium Alloys, J.L. Murray, Ed., ASM, Materials Park, 1987, p 289–293
35.
go back to reference F.F. Komarov, Ion Implantation into Metals, Metallurgiya, Moscow, 1990 [in Russian] F.F. Komarov, Ion Implantation into Metals, Metallurgiya, Moscow, 1990 [in Russian]
36.
go back to reference R. Goyer, Toxic Effect of Metals, Cassarett and Doull’s Toxicology, C. Klassen, M. Amdun, and J. Doul, Ed., McGraw-Hill, New York, 1986, p 582–635 R. Goyer, Toxic Effect of Metals, Cassarett and Doull’s Toxicology, C. Klassen, M. Amdun, and J. Doul, Ed., McGraw-Hill, New York, 1986, p 582–635
37.
go back to reference A.L. Yarosh, A.A. Dolzhikov, A.V. Soloshenko et al., Study of Biocompatibility of Surgical Implants for a New Generation of Plastics Anterior Abdominal Wall, Med. Nauki, 2011, 10, p 186–189 [in Russian] A.L. Yarosh, A.A. Dolzhikov, A.V. Soloshenko et al., Study of Biocompatibility of Surgical Implants for a New Generation of Plastics Anterior Abdominal Wall, Med. Nauki, 2011, 10, p 186–189 [in Russian]
38.
go back to reference J.H. Kim, J.H. Shin, D.H. Shin et al., Comparison of Diamond-Like Carbon-Coated Nitinol Stents With or Without Polyethylene Glycol Grafting and Uncoated Nitinol Stents in a Canine Iliac Artery Model, Br. J. Radiol., 2011, 999(84), p 210–215CrossRef J.H. Kim, J.H. Shin, D.H. Shin et al., Comparison of Diamond-Like Carbon-Coated Nitinol Stents With or Without Polyethylene Glycol Grafting and Uncoated Nitinol Stents in a Canine Iliac Artery Model, Br. J. Radiol., 2011, 999(84), p 210–215CrossRef
Metadata
Title
Effect of Surface Alloying by Silicon on the Corrosion Resistance and Biocompatibility of the Binary NiTi
Authors
S. G. Psakhie
S. N. Meisner
A. I. Lotkov
L. L. Meisner
A. V. Tverdokhlebova
Publication date
01-07-2014
Publisher
Springer US
Published in
Journal of Materials Engineering and Performance / Issue 7/2014
Print ISSN: 1059-9495
Electronic ISSN: 1544-1024
DOI
https://doi.org/10.1007/s11665-014-1112-7

Other articles of this Issue 7/2014

Journal of Materials Engineering and Performance 7/2014 Go to the issue

Premium Partners