Skip to main content
Top
Published in: Microsystem Technologies 3-4/2007

01-02-2007 | Technical Paper

High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector

Authors: Kabseog Kim, Jeong-Bong Lee

Published in: Microsystem Technologies | Issue 3-4/2007

Log in

Activate our intelligent search to find suitable subject content or patents.

search-config
loading …

Abstract

We present a novel microfabrication method for a tapered hollow metallic microneedle array and its complete microfluidic packaging for drug delivery and body fluid sampling applications. Backside exposure of SU-8 through a UV transparent substrate was investigated as a means of fabricating a dense array of tall (up to 400 μm) uniformly tapered SU-8 pillar structures with angles in the range of 3.1–5° on top of the SU-8 mesa. Conformal electroplating of metals on top of the array of the tapered SU-8 pillars, lapping of the tip of the metallic microneedles with planarizing polymer, and removal of the SU-8 sacrificial layers resulted in an array of tapered hollow metallic microneedles with a fluidic reservoir on the backside. A microfluidic interconnector assembly was designed and fabricated using SU-8 and conventionally machined PMMA in a way that it has a male interconnector, which directly fits into the fluidic reservoir of the microneedle array at one end and the other male interconnector, which provides fluidic interconnection to external devices at the other end. The fluid flow rate was measured and it showed 0.69 μL/s. per microneedle when the pressure of 6.89 KPa (1 psi) was applied.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
go back to reference Ahn C, Choi J, Beaucage G, Nevin J, Lee J, Puntambekar A, Lee J (2004) Disposable smart lab-on-a-chip for point-of-care clinical diagnostics. Proc IEEE 92:154–173CrossRef Ahn C, Choi J, Beaucage G, Nevin J, Lee J, Puntambekar A, Lee J (2004) Disposable smart lab-on-a-chip for point-of-care clinical diagnostics. Proc IEEE 92:154–173CrossRef
go back to reference Davis S, Prausnitz M, Allen M (2003) Fabrication and characterization of laser micromachined hollow microneedles, Dig. In: Transducers’03, international conference on solid-state sensors and actuators, pp 1435–1438 Davis S, Prausnitz M, Allen M (2003) Fabrication and characterization of laser micromachined hollow microneedles, Dig. In: Transducers’03, international conference on solid-state sensors and actuators, pp 1435–1438
go back to reference Gardeniers H, Luttge R, Berenschot E, de Boer M, Yeshurun S, Hefetz M, Oever R, Berg A (2003) Silicon micromachined hollow microneedles for transdermal liquid transport. J Microelectromech Syst 12:855–862CrossRef Gardeniers H, Luttge R, Berenschot E, de Boer M, Yeshurun S, Hefetz M, Oever R, Berg A (2003) Silicon micromachined hollow microneedles for transdermal liquid transport. J Microelectromech Syst 12:855–862CrossRef
go back to reference Griss P, Stemme G (2003) Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. J Microelectromech Syst 12:296–301CrossRef Griss P, Stemme G (2003) Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. J Microelectromech Syst 12:296–301CrossRef
go back to reference Henry S, McAllister D, Allen M, Prausnitz M (1998) Microfabricated microneedles: a novel approach to transdermal drug delivery. J Pharm Sci 87:922–925CrossRef Henry S, McAllister D, Allen M, Prausnitz M (1998) Microfabricated microneedles: a novel approach to transdermal drug delivery. J Pharm Sci 87:922–925CrossRef
go back to reference Kim K, Park D, Lu H, Che W, Kim K, Lee J, Ahn C (2004) A tapered hollow metallic microneedle array using backside exposure of SU-8. J Micromech Microeng 14:597–603CrossRef Kim K, Park D, Lu H, Che W, Kim K, Lee J, Ahn C (2004) A tapered hollow metallic microneedle array using backside exposure of SU-8. J Micromech Microeng 14:597–603CrossRef
go back to reference Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1997) SU-8: a low-cost negative resist for MEMS. J Micromech Microeng 7:121–124CrossRef Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1997) SU-8: a low-cost negative resist for MEMS. J Micromech Microeng 7:121–124CrossRef
go back to reference Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1998) High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS. Sensors and Actuators A 64:33–39CrossRef Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1998) High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS. Sensors and Actuators A 64:33–39CrossRef
go back to reference McAllister D, Cros F, Davis S, Matta L, Prausnitz M, Allen M (1999) Three-dimensional hollow microneedle and microtube arrays, Dig. In: Transducers’99, international conference on solid-state sensors and actuators, pp 1098–1101 McAllister D, Cros F, Davis S, Matta L, Prausnitz M, Allen M (1999) Three-dimensional hollow microneedle and microtube arrays, Dig. In: Transducers’99, international conference on solid-state sensors and actuators, pp 1098–1101
go back to reference Moon S, Lee S (2005) A novel fabrication method of a microneedle array using inclined deep x-ray exposure. J Micromech Microeng 15:903–911CrossRef Moon S, Lee S (2005) A novel fabrication method of a microneedle array using inclined deep x-ray exposure. J Micromech Microeng 15:903–911CrossRef
go back to reference Peterman M, Huie P, Bloom D, Fishman H (2003) Building thick photoresist structures from the bottom up. J Micromech Microeng 13:380–382CrossRef Peterman M, Huie P, Bloom D, Fishman H (2003) Building thick photoresist structures from the bottom up. J Micromech Microeng 13:380–382CrossRef
go back to reference Stoeber B, Liepmann D (2005) Arrays of hollow out-of-plane microneedles for drug delivery. J Microelectromech Syst 14:472–479CrossRef Stoeber B, Liepmann D (2005) Arrays of hollow out-of-plane microneedles for drug delivery. J Microelectromech Syst 14:472–479CrossRef
go back to reference Zhang J, Tan K, Hong G, Yang L, Gong H (2001) Polymerization optimization of SU-8 photoresist and its applications in microfluidic systems and MEMS. J Micromech Microeng 11:20–26CrossRef Zhang J, Tan K, Hong G, Yang L, Gong H (2001) Polymerization optimization of SU-8 photoresist and its applications in microfluidic systems and MEMS. J Micromech Microeng 11:20–26CrossRef
go back to reference Zimmermann S, Fienbork D, Flounders A, Liepmann D (2004) In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor. Sensors Actuat B 99:163–173CrossRef Zimmermann S, Fienbork D, Flounders A, Liepmann D (2004) In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor. Sensors Actuat B 99:163–173CrossRef
Metadata
Title
High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector
Authors
Kabseog Kim
Jeong-Bong Lee
Publication date
01-02-2007
Publisher
Springer-Verlag
Published in
Microsystem Technologies / Issue 3-4/2007
Print ISSN: 0946-7076
Electronic ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-006-0221-0

Other articles of this Issue 3-4/2007

Microsystem Technologies 3-4/2007 Go to the issue