Abstract

Medical application, in particular nuclear medicine, is one of the most promising fields of application of II-VI semiconductor-based radiation detectors. This chapter provides a description of this section of clinical medicine and discusses basic diagnostic and treatment methods such as single photon emission computed tomography (SPECT), positron emission tomography (PET), computed tomography (CT), and radiation therapy. The radiation detectors used in these devices are analyzed and the advantages of semiconductor radiation detectors for such applications are given. The use of radiation detectors in digital radiography, which includes chest X-ray imaging, high-resolution dental digital radiography systems, mammography, and bone densitometry, is discussed in detail. Examples of devices developed on the basis of II-VI semiconductor-based radiation detectors are given.

Dont have a licence yet? Then find out more about our products and how to get one now:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literature
1.
go back to reference Abbaspour S, Mahmoudian B, Islamian JP. Cadmium telluride semiconductor detector for improved spatial and energy resolution radioisotopic imaging. World J Nucl Med. 2017;16(2):101–7.CrossRef Abbaspour S, Mahmoudian B, Islamian JP. Cadmium telluride semiconductor detector for improved spatial and energy resolution radioisotopic imaging. World J Nucl Med. 2017;16(2):101–7.CrossRef
2.
go back to reference Ando K, Kase Y, Matsufuji N. Light ion radiation biology. Compreh Biomed Phys. 2014;7:195–210.CrossRef Ando K, Kase Y, Matsufuji N. Light ion radiation biology. Compreh Biomed Phys. 2014;7:195–210.CrossRef
4.
go back to reference Arnold MW, Schneebaum S, Berens A, Mojzicik C, Hinkle G, Martin EW. Radioimmunoguided surgery challenges traditional decision making in patients with primary colorectal cancer. Surgery. 1992;112:624–9. Arnold MW, Schneebaum S, Berens A, Mojzicik C, Hinkle G, Martin EW. Radioimmunoguided surgery challenges traditional decision making in patients with primary colorectal cancer. Surgery. 1992;112:624–9.
5.
go back to reference Badawi RD, Shi H, Hu P, Chen S, Xu T, Price PM, et al. First human imaging studies with the EXPLORER total-body PET scanner. J Nucl Med. 2019;60(3):299–303.CrossRef Badawi RD, Shi H, Hu P, Chen S, Xu T, Price PM, et al. First human imaging studies with the EXPLORER total-body PET scanner. J Nucl Med. 2019;60(3):299–303.CrossRef
6.
go back to reference Bai C, Babla H, Kindem J, Cornwell R. Evaluation of a cardiac SPECT system using a common set of solid-state detectors for both emission and transmission scans and an ultra-low dose lead X-ray transmission line source. IEEE Nucl Sci Symp Conf Rec. 2009;M13-81:3606–10. Bai C, Babla H, Kindem J, Cornwell R. Evaluation of a cardiac SPECT system using a common set of solid-state detectors for both emission and transmission scans and an ultra-low dose lead X-ray transmission line source. IEEE Nucl Sci Symp Conf Rec. 2009;M13-81:3606–10.
7.
go back to reference Barber WC, Wessel JC, Nygard E, Iwanczyk JS. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications. Nucl Instrum Methods Phys Res A. 2015;784:531–7.ADSCrossRef Barber WC, Wessel JC, Nygard E, Iwanczyk JS. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications. Nucl Instrum Methods Phys Res A. 2015;784:531–7.ADSCrossRef
8.
go back to reference Bell ZW, Cristy SS, Lamberti VE, Burger A, Woodfield BF, Niedermayr T, et al. Neutron detection with cryogenics and semiconductors. Phys Status Solidi C. 2005;2:1592–605.ADSCrossRef Bell ZW, Cristy SS, Lamberti VE, Burger A, Woodfield BF, Niedermayr T, et al. Neutron detection with cryogenics and semiconductors. Phys Status Solidi C. 2005;2:1592–605.ADSCrossRef
9.
go back to reference Ben-Haim S, Kacperski K, Hain S, Van Gramberg D, Hutton BF, Erlandsson K, et al. Simultaneous dualradionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol. 2010;37(9):1710–21. Ben-Haim S, Kacperski K, Hain S, Van Gramberg D, Hutton BF, Erlandsson K, et al. Simultaneous dualradionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol. 2010;37(9):1710–21.
10.
go back to reference Besch HJ. Radiation detectors in medical and biological applications. Nucl Instrum Methods Phys Res A. 1998;419:202–16.ADSCrossRef Besch HJ. Radiation detectors in medical and biological applications. Nucl Instrum Methods Phys Res A. 1998;419:202–16.ADSCrossRef
11.
go back to reference Bramblett RL, Ewing RI, Bonner TW. A new type of neutron spectrometer. Nucl Instr Methods. 1960;9:1–12.CrossRef Bramblett RL, Ewing RI, Bonner TW. A new type of neutron spectrometer. Nucl Instr Methods. 1960;9:1–12.CrossRef
12.
go back to reference Britten AJ. A method to evaluate intra-operative gamma probes for sentinel lymph node localisation. Eur J Nucl Med. 1999;26:76–83.CrossRef Britten AJ. A method to evaluate intra-operative gamma probes for sentinel lymph node localisation. Eur J Nucl Med. 1999;26:76–83.CrossRef
13.
go back to reference Brodyn S, Degoda VY, Sofiienko AO, Kozhushko BV, Vesna VT. Monocrystalline ZnSe as an ionising radiation detector operated over a wide temperature range. Radiat Meas. 2014;65:36–44.CrossRef Brodyn S, Degoda VY, Sofiienko AO, Kozhushko BV, Vesna VT. Monocrystalline ZnSe as an ionising radiation detector operated over a wide temperature range. Radiat Meas. 2014;65:36–44.CrossRef
14.
go back to reference Butler JF, Lingren C, Fruesenhahn SJ, Doty FP, Ashburn WL, Conwell RL, et al. CdZnTe solid-state γ camera. IEEE Trans Nucl Sci. 1998;NS-45:359–63.ADSCrossRef Butler JF, Lingren C, Fruesenhahn SJ, Doty FP, Ashburn WL, Conwell RL, et al. CdZnTe solid-state γ camera. IEEE Trans Nucl Sci. 1998;NS-45:359–63.ADSCrossRef
15.
go back to reference Cavallini A, Fraboni B, Dusi W, Auricchio N, Chirco P, Zanarini M, Siffert P, Fougeres P. Radiation effects on II-VI compound-based detectors. Nucl Instrum Methods Phys Res A. 2002;476(3):770–8.ADSCrossRef Cavallini A, Fraboni B, Dusi W, Auricchio N, Chirco P, Zanarini M, Siffert P, Fougeres P. Radiation effects on II-VI compound-based detectors. Nucl Instrum Methods Phys Res A. 2002;476(3):770–8.ADSCrossRef
16.
go back to reference Cuzin M, Glasser F, Mermet R, Meunier N, Peyret C, Rambdud P. Preliminary characterization of a new hybrid structure with CdTe: X-ray imaging capabilities. SPIE. 1994;2278:21–7.ADS Cuzin M, Glasser F, Mermet R, Meunier N, Peyret C, Rambdud P. Preliminary characterization of a new hybrid structure with CdTe: X-ray imaging capabilities. SPIE. 1994;2278:21–7.ADS
17.
go back to reference Carney PA, Miglioretti DL, Yankaskas BC, Kerlikowske K, Rosenberg R, Rutter CM, et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Int Med. 2003;138:168–75.CrossRef Carney PA, Miglioretti DL, Yankaskas BC, Kerlikowske K, Rosenberg R, Rutter CM, et al. Individual and combined effects of age, breast density, and hormone replacement therapy use on the accuracy of screening mammography. Ann Int Med. 2003;138:168–75.CrossRef
18.
go back to reference Darambara D, Todd-pokropek A. Solid state detectors in nuclear medicine. Q J Nucl Med. 2002;46:3–7. Darambara D, Todd-pokropek A. Solid state detectors in nuclear medicine. Q J Nucl Med. 2002;46:3–7.
19.
go back to reference Debnath SBC, Fauquet C, Tallet A, Goncalves A, Lavandier S, Jandard F, et al. High spatial resolution inorganic scintillator detector for high-energy X-ray beam at small field irradiation. Med Phys. 2020;47(3):1364–71.CrossRef Debnath SBC, Fauquet C, Tallet A, Goncalves A, Lavandier S, Jandard F, et al. High spatial resolution inorganic scintillator detector for high-energy X-ray beam at small field irradiation. Med Phys. 2020;47(3):1364–71.CrossRef
20.
go back to reference Del Sordo S, Abbene L, Caroli E, Mancini AM, Zappettini A, Ubertini P. Progress in the development of CdTe and CdZnTe semiconductor radiation detectors for astrophysical and medical applications. Sensors. 2009;9:3491–526.ADSCrossRef Del Sordo S, Abbene L, Caroli E, Mancini AM, Zappettini A, Ubertini P. Progress in the development of CdTe and CdZnTe semiconductor radiation detectors for astrophysical and medical applications. Sensors. 2009;9:3491–526.ADSCrossRef
21.
go back to reference Eisen Y, Shor A, Gilath C, Tsabarim M, Chouraqui P, Hellman C, et al. A γ camera based on CdTe detectors. Nucl Instr Methods Phys Res A. 1996;380:474–8.ADSCrossRef Eisen Y, Shor A, Gilath C, Tsabarim M, Chouraqui P, Hellman C, et al. A γ camera based on CdTe detectors. Nucl Instr Methods Phys Res A. 1996;380:474–8.ADSCrossRef
22.
go back to reference Eisen Y, Polak E. An array of CdTe detectors for imaging applications. Proc Mater Res Soc Symp. 1993;302:487–95.CrossRef Eisen Y, Polak E. An array of CdTe detectors for imaging applications. Proc Mater Res Soc Symp. 1993;302:487–95.CrossRef
23.
go back to reference Gambhir SS, Berman DS, Ziffer J, Nagler M, Sandler M, Patton J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med. 2009;50:635–43.CrossRef Gambhir SS, Berman DS, Ziffer J, Nagler M, Sandler M, Patton J, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med. 2009;50:635–43.CrossRef
24.
go back to reference Gasanov AA, Kuznetsov MS, Naumov АV. Domestic crystals manufacturing for devices used in photonics. Part 2 – semicoductor ionizing radiation detectors. Photonics Russia. 2018;12(5):514–9. (in Russian)CrossRef Gasanov AA, Kuznetsov MS, Naumov АV. Domestic crystals manufacturing for devices used in photonics. Part 2 – semicoductor ionizing radiation detectors. Photonics Russia. 2018;12(5):514–9. (in Russian)CrossRef
25.
go back to reference Gelaw SM. Screening chest X-ray interpretations and radiographic techniques. IOM guidelines. Global Radiology Coordination and Teleradiology Centre, Makati city, Philippines; 2015. Gelaw SM. Screening chest X-ray interpretations and radiographic techniques. IOM guidelines. Global Radiology Coordination and Teleradiology Centre, Makati city, Philippines; 2015.
26.
go back to reference Giakos GC, Vedantham S, Chowdhury S, Odogba J, Dasgupta A, Guntupalli R, et al. Timing characteristics of a Cd1-xZnxTe detector-based X-ray imaging system. IEEE Trans Instrum Meas. 1999;48(5):909–14.ADSCrossRef Giakos GC, Vedantham S, Chowdhury S, Odogba J, Dasgupta A, Guntupalli R, et al. Timing characteristics of a Cd1-xZnxTe detector-based X-ray imaging system. IEEE Trans Instrum Meas. 1999;48(5):909–14.ADSCrossRef
27.
go back to reference Fowler AM. A molecular approach to breast imaging. J Nucl Med. 2014;55:177–80.CrossRef Fowler AM. A molecular approach to breast imaging. J Nucl Med. 2014;55:177–80.CrossRef
28.
go back to reference Heller S, Zanzonico P. Nuclear probes and intraoperative gamma cameras. Semin Nucl Med. 2011;41:166–81.CrossRef Heller S, Zanzonico P. Nuclear probes and intraoperative gamma cameras. Semin Nucl Med. 2011;41:166–81.CrossRef
29.
go back to reference Henzlova MJ, Duvall WL. The future of SPECT MPI: time and dose reduction. J Nucl Cardiol. 2011;18:580–7.CrossRef Henzlova MJ, Duvall WL. The future of SPECT MPI: time and dose reduction. J Nucl Cardiol. 2011;18:580–7.CrossRef
30.
go back to reference Hruska CB, O’Connor MK. Nuclear imaging of the breast: translating achievements in instrumentation into clinical use. Med Phys. 2013;40:050901.CrossRef Hruska CB, O’Connor MK. Nuclear imaging of the breast: translating achievements in instrumentation into clinical use. Med Phys. 2013;40:050901.CrossRef
31.
go back to reference Hruska CB, Weinmann AL, O’Connor MK. Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms. Med Phys. 2012;39(6):3466–75.CrossRef Hruska CB, Weinmann AL, O’Connor MK. Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms. Med Phys. 2012;39(6):3466–75.CrossRef
32.
go back to reference Imbert L, Poussier S, Franken PR, Songy B, Verger A, Morel O, et al. Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images. J Nucl Med. 2012;53(12):1897–903.CrossRef Imbert L, Poussier S, Franken PR, Songy B, Verger A, Morel O, et al. Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images. J Nucl Med. 2012;53(12):1897–903.CrossRef
33.
go back to reference Iniewski K. CZT detector technology for medical imaging. JINST. 2014;9:C11001.CrossRef Iniewski K. CZT detector technology for medical imaging. JINST. 2014;9:C11001.CrossRef
34.
go back to reference Ito T, Matsusaka Y, Onoguchi M, Ichikawa H, Okuda K, Shibutani T, Shishido M, Sato K. Experimental evaluation of the GE NM/CT 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator. J Appl Clin Med Phys. 2021;22:165–77.CrossRef Ito T, Matsusaka Y, Onoguchi M, Ichikawa H, Okuda K, Shibutani T, Shishido M, Sato K. Experimental evaluation of the GE NM/CT 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator. J Appl Clin Med Phys. 2021;22:165–77.CrossRef
35.
go back to reference Jahnke A, Matz R. Signal formation and decay in CdTe X-ray detectors under intense irradiation. Med Phys. 1999;26:38–48.CrossRef Jahnke A, Matz R. Signal formation and decay in CdTe X-ray detectors under intense irradiation. Med Phys. 1999;26:38–48.CrossRef
36.
go back to reference Kolb TM, Lichy J, Newhouse JH. Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27825 patient evaluations. Radiology. 2002;225:165–75.CrossRef Kolb TM, Lichy J, Newhouse JH. Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27825 patient evaluations. Radiology. 2002;225:165–75.CrossRef
37.
go back to reference Kwak S-W, Choi J, Park SS, Ahn SH, Park JS, Chung H. Comparison of experimental results of a Quad-CZT array detector, a NaI(Tl), a LaBr3(Ce), and a HPGe for safeguards applications. J Instrum. 2017;12:C11011.CrossRef Kwak S-W, Choi J, Park SS, Ahn SH, Park JS, Chung H. Comparison of experimental results of a Quad-CZT array detector, a NaI(Tl), a LaBr3(Ce), and a HPGe for safeguards applications. J Instrum. 2017;12:C11011.CrossRef
38.
go back to reference Langlais R, Katsumata A, Naidoo S, Ogawa K, Fukui T, Shimoda S, Kobayashi K. The cadmium telluride photon counting sensor in panoramic radiology: gray value separation and its potential application for bone density evaluation. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(5):636–43.CrossRef Langlais R, Katsumata A, Naidoo S, Ogawa K, Fukui T, Shimoda S, Kobayashi K. The cadmium telluride photon counting sensor in panoramic radiology: gray value separation and its potential application for bone density evaluation. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;120(5):636–43.CrossRef
39.
go back to reference Lee CH, Dershaw D, Kopans D, Evans P, Monsees B, Monticciolo D, et al. Breast cancer screening with imaging: recommendations from the society of breast imaging and the ACR on the use of mammography, breast MRI, breast ultrasound, and other technologies for the detection of clinically occult breast cancer. J Am Col Radiol. 2010;7:18–27.CrossRef Lee CH, Dershaw D, Kopans D, Evans P, Monsees B, Monticciolo D, et al. Breast cancer screening with imaging: recommendations from the society of breast imaging and the ACR on the use of mammography, breast MRI, breast ultrasound, and other technologies for the detection of clinically occult breast cancer. J Am Col Radiol. 2010;7:18–27.CrossRef
40.
go back to reference Linardatos D, Konstantinidis A, Valais I, Ninos K, Kalyvas N, Bakas A, et al. On the optical response of tellurium activated zinc selenide ZnSe: Te single crystal. Crystals. 2020;10:961.CrossRef Linardatos D, Konstantinidis A, Valais I, Ninos K, Kalyvas N, Bakas A, et al. On the optical response of tellurium activated zinc selenide ZnSe: Te single crystal. Crystals. 2020;10:961.CrossRef
41.
go back to reference Lopes MI, Chepel V. Detectors for medical radioisotope imaging: demands and perspectives. Rad Phys Chem. 2004;71:683–92.ADSCrossRef Lopes MI, Chepel V. Detectors for medical radioisotope imaging: demands and perspectives. Rad Phys Chem. 2004;71:683–92.ADSCrossRef
42.
go back to reference Malouff TD, Mahajan A, Krishnan S, Beltran C, Seneviratne DS, Trifiletti DM. Carbon ion therapy: a modern review of an emerging technology. Front Oncol. 2020;10:82.CrossRef Malouff TD, Mahajan A, Krishnan S, Beltran C, Seneviratne DS, Trifiletti DM. Carbon ion therapy: a modern review of an emerging technology. Front Oncol. 2020;10:82.CrossRef
43.
go back to reference Mariani G, Vaiano A, Nibale O, Rubello D. Is the “ideal” γ-probe for intraoperative radioguided surgery conceivable? J Nucl Med. 2005;46(3):388–90. Mariani G, Vaiano A, Nibale O, Rubello D. Is the “ideal” γ-probe for intraoperative radioguided surgery conceivable? J Nucl Med. 2005;46(3):388–90.
44.
go back to reference Martin-Martin A, Iniguez MP, Luke PN, Barquero R, Lorente A, Morchon J, et al. Evaluation of CdZnTe as neutron detector around medical accelerators. Rad Protect Dosimetry. 2009;133(4):193–9.CrossRef Martin-Martin A, Iniguez MP, Luke PN, Barquero R, Lorente A, Morchon J, et al. Evaluation of CdZnTe as neutron detector around medical accelerators. Rad Protect Dosimetry. 2009;133(4):193–9.CrossRef
45.
go back to reference Mayerhoefer ME, Prosch H, Beer L, Tamandl D, Beyer T, Hoeller C, et al. PET/MRI versus PET/CT in oncology: a prospective single-center study of 330 examinations focusing on implications for patient management and cost considerations. Eur J Nucl Med Mol Imaging. 2019;47(1):51–60.CrossRef Mayerhoefer ME, Prosch H, Beer L, Tamandl D, Beyer T, Hoeller C, et al. PET/MRI versus PET/CT in oncology: a prospective single-center study of 330 examinations focusing on implications for patient management and cost considerations. Eur J Nucl Med Mol Imaging. 2019;47(1):51–60.CrossRef
46.
go back to reference Mc Gann WJ, Cirignano L, Entine G, Biggs P. A new solid-state detector for radiation-therapy imaging. Nucl Instr Methods A. 1990;299:172–5.ADSCrossRef Mc Gann WJ, Cirignano L, Entine G, Biggs P. A new solid-state detector for radiation-therapy imaging. Nucl Instr Methods A. 1990;299:172–5.ADSCrossRef
47.
go back to reference Morimoto Y, Ueno Y, Takeuchi W, Kojima S, Matsuzaki K, Ishitsu T, et al. Development of a 3D brain PET scanner using CdTe semiconductor detectors and its first clinical application. IEEE Trans Nucl Sci. 2011;58(5):2181–9.ADSCrossRef Morimoto Y, Ueno Y, Takeuchi W, Kojima S, Matsuzaki K, Ishitsu T, et al. Development of a 3D brain PET scanner using CdTe semiconductor detectors and its first clinical application. IEEE Trans Nucl Sci. 2011;58(5):2181–9.ADSCrossRef
48.
go back to reference McParland BJ. A study of patient radiation doses in interventional radiological procedures. J Radiol. 1998;71:175–85.CrossRef McParland BJ. A study of patient radiation doses in interventional radiological procedures. J Radiol. 1998;71:175–85.CrossRef
49.
go back to reference Miyake KK, Matsumoto K, Inoue M, Nakamoto Y, Kanao S, Oishi T, S., et al. Performance evaluation of a new dedicated breast PET scanner using NEMA NU4-2008 standards. J Nucl Med. 2014;55:1198–203.CrossRef Miyake KK, Matsumoto K, Inoue M, Nakamoto Y, Kanao S, Oishi T, S., et al. Performance evaluation of a new dedicated breast PET scanner using NEMA NU4-2008 standards. J Nucl Med. 2014;55:1198–203.CrossRef
50.
go back to reference Moses WW, Derenzo SE, Budinger TF. PET detector modules based on novel detector technologies. Nucl Instr Meth A. 1994;353:189–94.ADSCrossRef Moses WW, Derenzo SE, Budinger TF. PET detector modules based on novel detector technologies. Nucl Instr Meth A. 1994;353:189–94.ADSCrossRef
51.
go back to reference Nestle U, Weber W, Hentschel M, Grosu AC. Biological imaging in radiation therapy: role of positron emission tomography. Phys Med Biol. 2009;54:R1–25.ADSCrossRef Nestle U, Weber W, Hentschel M, Grosu AC. Biological imaging in radiation therapy: role of positron emission tomography. Phys Med Biol. 2009;54:R1–25.ADSCrossRef
52.
go back to reference Ogawa K, Muraishi M. Feasibility study on an ultra-high-resolution SPECT with CdTe detectors. IEEE Trans Nucl Sci. 2010;57:17–24.ADSCrossRef Ogawa K, Muraishi M. Feasibility study on an ultra-high-resolution SPECT with CdTe detectors. IEEE Trans Nucl Sci. 2010;57:17–24.ADSCrossRef
53.
go back to reference Ogawa K, Langlais RP, McDavid WD, Noujeim M, Seki K, Okano T, et al. Development of a new dental panoramic radiographic system based on a tomosynthesis method. Dentomaxillofac Radiol. 2010;39:47–53.CrossRef Ogawa K, Langlais RP, McDavid WD, Noujeim M, Seki K, Okano T, et al. Development of a new dental panoramic radiographic system based on a tomosynthesis method. Dentomaxillofac Radiol. 2010;39:47–53.CrossRef
54.
go back to reference Ogawa K, Ohmura N, Iida H, Nakamura K, Nakahara T, Kubo A. Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector. Ann Nucl Med. 2009;23:763–70.CrossRef Ogawa K, Ohmura N, Iida H, Nakamura K, Nakahara T, Kubo A. Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector. Ann Nucl Med. 2009;23:763–70.CrossRef
55.
go back to reference Ohtsuchi T, Tsuitsui H, Ohmori K, Baba S. X-ray imaging sensor using CdTe crystals for dual energy X-ray absorptiometry. IEEE Trans Nucl Sci. 1994;NS-41:1740–5.ADSCrossRef Ohtsuchi T, Tsuitsui H, Ohmori K, Baba S. X-ray imaging sensor using CdTe crystals for dual energy X-ray absorptiometry. IEEE Trans Nucl Sci. 1994;NS-41:1740–5.ADSCrossRef
56.
go back to reference Park SJ, Lee CL, Cho HM, Kim HJ. Ultra high resolution SPECT with CdTe for small animal imaging applications: Monte Carlo simulation study using voxelized phantom. J Korean Phys Soc. 2012;60:1145–9.CrossRef Park SJ, Lee CL, Cho HM, Kim HJ. Ultra high resolution SPECT with CdTe for small animal imaging applications: Monte Carlo simulation study using voxelized phantom. J Korean Phys Soc. 2012;60:1145–9.CrossRef
57.
go back to reference Pisano ED, Hendrick RE, Yaffe MJ, Baum JK, Acharyya S, Cormack JB, et al. Diagnostic accuracy of digital versus film mammography: exploratory analysis of selected population subgroups in DMIST. Radiology. 2008;246:376–83.CrossRef Pisano ED, Hendrick RE, Yaffe MJ, Baum JK, Acharyya S, Cormack JB, et al. Diagnostic accuracy of digital versus film mammography: exploratory analysis of selected population subgroups in DMIST. Radiology. 2008;246:376–83.CrossRef
58.
go back to reference Procz S, Roque G, Avila C, Racedo J, Rueda R, Santos I, Fiederle M. Investigation of CdTe, GaAs, Se and Si as sensor materials for mammography. IEEE Trans Med Imaging. 2020;39(12):3766–78.CrossRef Procz S, Roque G, Avila C, Racedo J, Rueda R, Santos I, Fiederle M. Investigation of CdTe, GaAs, Se and Si as sensor materials for mammography. IEEE Trans Med Imaging. 2020;39(12):3766–78.CrossRef
59.
go back to reference Ramírez M, Martínez N, Marcazzó J, Molina P, Feld D, Santiago M. Performance of ZnSe(Te) as fiberoptic dosimetry detector. Appl Radiat Isot. 2016;116:1–7.CrossRef Ramírez M, Martínez N, Marcazzó J, Molina P, Feld D, Santiago M. Performance of ZnSe(Te) as fiberoptic dosimetry detector. Appl Radiat Isot. 2016;116:1–7.CrossRef
60.
go back to reference Román RJ, Ruiz García I, Escobedo Araque P, Palma López AJ, Guirado Llorente D, Carvajal MA. Light-dependent resistors as dosimetric sensors in radiotherapy. Sensors. 2020;20(6):1568.ADSCrossRef Román RJ, Ruiz García I, Escobedo Araque P, Palma López AJ, Guirado Llorente D, Carvajal MA. Light-dependent resistors as dosimetric sensors in radiotherapy. Sensors. 2020;20(6):1568.ADSCrossRef
61.
go back to reference Rosenfeld AB. Semiconductor detectors in radiation medicine: radiotherapy and related applications. In: Tavernier S, Gektin A, Grinyov B, Moses WW, editors. Radiation detectors for medical applications. New York: Springer; 2006. p. 111–47.CrossRef Rosenfeld AB. Semiconductor detectors in radiation medicine: radiotherapy and related applications. In: Tavernier S, Gektin A, Grinyov B, Moses WW, editors. Radiation detectors for medical applications. New York: Springer; 2006. p. 111–47.CrossRef
62.
go back to reference Royo P, Pastor E, Macias M, Cuadrado R, Barrado C, Vargas A. An unmanned aircraft system to detect a radiological point source using RIMA software architecture. Remote Sens. 2018;10(11):1712.ADSCrossRef Royo P, Pastor E, Macias M, Cuadrado R, Barrado C, Vargas A. An unmanned aircraft system to detect a radiological point source using RIMA software architecture. Remote Sens. 2018;10(11):1712.ADSCrossRef
63.
go back to reference Russo P, Mettivier G, Pani R, Pellegrini R, Cinti MN, Bennati P. Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera. Med Phys. 2009;36:298–317.CrossRef Russo P, Mettivier G, Pani R, Pellegrini R, Cinti MN, Bennati P. Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera. Med Phys. 2009;36:298–317.CrossRef
64.
go back to reference Sato K, Sato N, Ukita M, Adachi S, Inoue T, Tokuda S et al. Development of multichannel CdTe radiation detectors, In: Proceedings of 9th Workshop on Radiation Detectors and Their Uses, 17–19 January1995, Tsukuba, pp. 208–218; 1995. Sato K, Sato N, Ukita M, Adachi S, Inoue T, Tokuda S et al. Development of multichannel CdTe radiation detectors, In: Proceedings of 9th Workshop on Radiation Detectors and Their Uses, 17–19 January1995, Tsukuba, pp. 208–218; 1995.
65.
go back to reference Scheiber C, Giakos GC. Medical applications of CdTe and CdZnTe detectors. Nucl Instrum Meth Phys Res A. 2001;458:12–25.ADSCrossRef Scheiber C, Giakos GC. Medical applications of CdTe and CdZnTe detectors. Nucl Instrum Meth Phys Res A. 2001;458:12–25.ADSCrossRef
66.
go back to reference Scheiber C. New developments in clinical applications of CdTe and CdZnTe detectors. Nucl Instrum Methods Phys Res A. 1996;380:385–91.ADSCrossRef Scheiber C. New developments in clinical applications of CdTe and CdZnTe detectors. Nucl Instrum Methods Phys Res A. 1996;380:385–91.ADSCrossRef
67.
go back to reference Schneider P, Bomer W. Peripheral quantitative computed tomography for bone mineral measurement with a new special purpose QCT-scanner. Fortschr Rontgenstr. 1991;154:292–9.CrossRef Schneider P, Bomer W. Peripheral quantitative computed tomography for bone mineral measurement with a new special purpose QCT-scanner. Fortschr Rontgenstr. 1991;154:292–9.CrossRef
68.
go back to reference Scuffham JW, Wilson MD, Seller P, Veale MC, Sellin PJ, Jacques SDM, Cernik RJ. A CdTe detector for hyperspectral SPECT imaging. JINST. 2012;7:P08027.CrossRef Scuffham JW, Wilson MD, Seller P, Veale MC, Sellin PJ, Jacques SDM, Cernik RJ. A CdTe detector for hyperspectral SPECT imaging. JINST. 2012;7:P08027.CrossRef
69.
go back to reference Sergienko VB, Ansheles AA. Nuclear medicine and molecular imaging in clinical practice: yesterday, today and tomorrow. Terapevticheskii Arkhiv. 2021;93(4):357–62. (in Russian)CrossRef Sergienko VB, Ansheles AA. Nuclear medicine and molecular imaging in clinical practice: yesterday, today and tomorrow. Terapevticheskii Arkhiv. 2021;93(4):357–62. (in Russian)CrossRef
70.
go back to reference Speller R, Royle G, Scannvini MG, Horrocks J. Impact of new digital X- and gamma ray imaging systems upon patient doses. Appl Radiat Isot. 1999;50:153–63.CrossRef Speller R, Royle G, Scannvini MG, Horrocks J. Impact of new digital X- and gamma ray imaging systems upon patient doses. Appl Radiat Isot. 1999;50:153–63.CrossRef
71.
go back to reference Sun M, Zhao D, Yin Z, Yang F, Jie W, Wang T. Material properties and device performance of CdSe radiation detectors. Nucl Instrum Methods Phys Res A. 2019;959:163487.CrossRef Sun M, Zhao D, Yin Z, Yang F, Jie W, Wang T. Material properties and device performance of CdSe radiation detectors. Nucl Instrum Methods Phys Res A. 2019;959:163487.CrossRef
72.
go back to reference Takahashi T, Watanabe S. Recent progress in CdTe and CdZnTe detectors. IEEE Trans Nucl Sci. 2001;48(4):950–9.ADSCrossRef Takahashi T, Watanabe S. Recent progress in CdTe and CdZnTe detectors. IEEE Trans Nucl Sci. 2001;48(4):950–9.ADSCrossRef
73.
go back to reference Martin EW, editor. Surgery in the detection and treatment of colorectal cancer. Landes Company; 1994. p. 42. Martin EW, editor. Surgery in the detection and treatment of colorectal cancer. Landes Company; 1994. p. 42.
74.
go back to reference Tiourina T, Arends B, Rutten H, Lemaire B, Muller S. Evaluation of surgical gamma probes for radioguided sentinel node localization. Eur J Nucl Med. 1998;25:1224–31.CrossRef Tiourina T, Arends B, Rutten H, Lemaire B, Muller S. Evaluation of surgical gamma probes for radioguided sentinel node localization. Eur J Nucl Med. 1998;25:1224–31.CrossRef
75.
go back to reference Tomasov AA, Arkad’eva EN, Zelenina N, Karpenko VP, Maslov LV, Matveev OA, Yazykov NN. CdTe X-ray detector for computed tomography. Zh Tekh Fiz. 1985;55:897–901. Tomasov AA, Arkad’eva EN, Zelenina N, Karpenko VP, Maslov LV, Matveev OA, Yazykov NN. CdTe X-ray detector for computed tomography. Zh Tekh Fiz. 1985;55:897–901.
76.
go back to reference Townsend DW. Positron emission tomography/computed tomography. Semin Nucl Med. 2008;38:152–66.CrossRef Townsend DW. Positron emission tomography/computed tomography. Semin Nucl Med. 2008;38:152–66.CrossRef
77.
go back to reference Tsuchiya K, Takahashi I, Kawaguchi T, Yokoi K, Morimoto Y, Ishitsu T, et al. Basic performance and stability of a CdTe solid state detector panel. Ann Nucl Med. 2010;24:301–11.CrossRef Tsuchiya K, Takahashi I, Kawaguchi T, Yokoi K, Morimoto Y, Ishitsu T, et al. Basic performance and stability of a CdTe solid state detector panel. Ann Nucl Med. 2010;24:301–11.CrossRef
78.
go back to reference Tsuitsui H, Ohtsuchi T, Ohmori K, Baba S. X-ray energy separation method using a CdTe semiconductor X-ray imaging sensor and photon counting method. IEEE Trans Nucl Sci. 1993;NS-40:40–4.ADSCrossRef Tsuitsui H, Ohtsuchi T, Ohmori K, Baba S. X-ray energy separation method using a CdTe semiconductor X-ray imaging sensor and photon counting method. IEEE Trans Nucl Sci. 1993;NS-40:40–4.ADSCrossRef
79.
go back to reference Tsuitsui H, Ohtsuchi T, Ohmori K, Baba S. Fabrication and characteristics of a submillimeter detector element formed on a CdTe single-crystal wafer as a multichannel detector array applicable to diagnostic imaging with energy information. Jpn J Appl Phys. 1993;32:228–33.ADSCrossRef Tsuitsui H, Ohtsuchi T, Ohmori K, Baba S. Fabrication and characteristics of a submillimeter detector element formed on a CdTe single-crystal wafer as a multichannel detector array applicable to diagnostic imaging with energy information. Jpn J Appl Phys. 1993;32:228–33.ADSCrossRef
80.
go back to reference Ueno Y, Morimoto Y, Tsuchiya K, Yanagita N, Kojima S, Ishitsu T, et al. Basic performance test of a prototype PET scanner using CdTe semiconductor detectors. IEEE Trans Nucl Sci. 2009;56:24–8.ADSCrossRef Ueno Y, Morimoto Y, Tsuchiya K, Yanagita N, Kojima S, Ishitsu T, et al. Basic performance test of a prototype PET scanner using CdTe semiconductor detectors. IEEE Trans Nucl Sci. 2009;56:24–8.ADSCrossRef
81.
go back to reference Van der Meulen NP, Strobel K, Miranda Lima TV. New radionuclides and technological advances in SPECT and PET scanners. Cancers. 2021;13:6183.CrossRef Van der Meulen NP, Strobel K, Miranda Lima TV. New radionuclides and technological advances in SPECT and PET scanners. Cancers. 2021;13:6183.CrossRef
82.
go back to reference Van der Stelt PF. Filmless imaging: the uses of digital radiography in dental practice. J Am Dent Assoc. 2005;136:1379–87.CrossRef Van der Stelt PF. Filmless imaging: the uses of digital radiography in dental practice. J Am Dent Assoc. 2005;136:1379–87.CrossRef
83.
go back to reference Van Roosmalen J, Goorden MC, Beekman FJ. Molecular breast tomosynthesis with scanning focus multi-pinhole cameras. Phys Med Biol. 2016;61:5508–28.CrossRef Van Roosmalen J, Goorden MC, Beekman FJ. Molecular breast tomosynthesis with scanning focus multi-pinhole cameras. Phys Med Biol. 2016;61:5508–28.CrossRef
84.
go back to reference Van Sluis J, de Jong J, Schaar J, Noordzij W, van Snick P, Dierckx R, et al. Performance characteristics of the digital biograph vision PET/CT system. J Nucl Med. 2019;60(7):1031–6.CrossRef Van Sluis J, de Jong J, Schaar J, Noordzij W, van Snick P, Dierckx R, et al. Performance characteristics of the digital biograph vision PET/CT system. J Nucl Med. 2019;60(7):1031–6.CrossRef
85.
go back to reference Veale MC, Bell SJ, Seller P, Wilson MD, Kachkanov V. X-ray micro-beam characterization of a small pixel spectroscopic CdTe detector. JINST. 2012;7:P07017.ADSCrossRef Veale MC, Bell SJ, Seller P, Wilson MD, Kachkanov V. X-ray micro-beam characterization of a small pixel spectroscopic CdTe detector. JINST. 2012;7:P07017.ADSCrossRef
86.
go back to reference Verger L, Boitel M, Gentet M, Hamelin R, Mestais C, Mongellaz F, et al. Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications. Nucl Instrum Methods Phys Res. 2001;458:297–309.ADSCrossRef Verger L, Boitel M, Gentet M, Hamelin R, Mestais C, Mongellaz F, et al. Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications. Nucl Instrum Methods Phys Res. 2001;458:297–309.ADSCrossRef
87.
go back to reference Wurm P, Hage-Ali M, Koebel JM, Siffert P. Study of the photodecay in CdTe X-ray detectors. Mater Sci Eng B. 1994;28:47–50.CrossRef Wurm P, Hage-Ali M, Koebel JM, Siffert P. Study of the photodecay in CdTe X-ray detectors. Mater Sci Eng B. 1994;28:47–50.CrossRef
88.
go back to reference Yaffe MJ, Rowlands JA. X-ray detectors for digital radiography. Phys Med Biol. 1997;42:1–39.CrossRef Yaffe MJ, Rowlands JA. X-ray detectors for digital radiography. Phys Med Biol. 1997;42:1–39.CrossRef
89.
go back to reference Yogo K, Tsuneda M, Horita R, Souda H, Matsumura A, Ishiyama H, et al. Three-dimensional dose-distribution measurement of therapeutic carbon-ion beams using a ZnS scintillator sheet. J Radiat Res. 2021;62(5):825–32.CrossRef Yogo K, Tsuneda M, Horita R, Souda H, Matsumura A, Ishiyama H, et al. Three-dimensional dose-distribution measurement of therapeutic carbon-ion beams using a ZnS scintillator sheet. J Radiat Res. 2021;62(5):825–32.CrossRef
90.
go back to reference Zelenina NK, Ignatov SM, Karpenko VP, Maslova LV, Matveev OA, Popov DA, et al. A study of CdTe MSM structures. Nucl Instrum Methods Phys Res A. 1989;283(2):274–8.ADSCrossRef Zelenina NK, Ignatov SM, Karpenko VP, Maslova LV, Matveev OA, Popov DA, et al. A study of CdTe MSM structures. Nucl Instrum Methods Phys Res A. 1989;283(2):274–8.ADSCrossRef
Metadata
Title
Medical Applications of II-VI Semiconductor-Based Radiation Detectors
Authors
Ghenadii Korotcenkov
Sergiu Vatavu
Copyright Year
2023
DOI
https://doi.org/10.1007/978-3-031-24000-3_5