Abstract

OCT is a promising technology that allows getting a lot of data in each sample. Authors hope that it is possible to create a system that would automatically diagnose various retinal diseases basing on OCT images with the accuracy of 95% which may revolutionize and shorten diagnostic pathway. At the beginning authors focus on automatic distinguishing the healthy images from pathological retinas. In this paper a novel approach has been presented. The algorithm has been described and results have been revealed and discussed. OCT is a way for detecting many various diseases. However, the amount of information to be processed is much more numerous so the task seems to be more difficult than it is in fundus imaging. In this paper some advanced diseases with the macular oedema detection algorithm basing on OCT images are presented.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Kelty, P.J., Payne, J.F., Trivedi, R.H., et al.: Macular thickness assessment in healthy eyes based on ethnicity using stratus OCT Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 49(6), 2668–2672 (2008)CrossRef Kelty, P.J., Payne, J.F., Trivedi, R.H., et al.: Macular thickness assessment in healthy eyes based on ethnicity using stratus OCT Optical Coherence Tomography. Invest. Ophthalmol. Vis. Sci. 49(6), 2668–2672 (2008)CrossRef
2.
Zurück zum Zitat Shah, A.R., Williams, S., Baumal, C.R., et al.: Predictors of response to intravitreal anti-vascular endothelial growth factor treatment of age-related macular degeneration. Am. J. Ophthalmol. 163, 154–166 (2016)CrossRef Shah, A.R., Williams, S., Baumal, C.R., et al.: Predictors of response to intravitreal anti-vascular endothelial growth factor treatment of age-related macular degeneration. Am. J. Ophthalmol. 163, 154–166 (2016)CrossRef
3.
Zurück zum Zitat Chen, Y., Li, J., Yan, Y., et al.: Diabetic macular morphology changes may occur in the early stage of diabetes. BMC Ophthalmol. 16(12) (2016) Chen, Y., Li, J., Yan, Y., et al.: Diabetic macular morphology changes may occur in the early stage of diabetes. BMC Ophthalmol. 16(12) (2016)
4.
Zurück zum Zitat Gooding, K.M., Shore, A.C., Ling, R., et al.: Regional differences in macular thickness in the early stages of diabetic retinopathy in type 2 diabetes. Diabetologia 58(1), S526 (2015) Gooding, K.M., Shore, A.C., Ling, R., et al.: Regional differences in macular thickness in the early stages of diabetic retinopathy in type 2 diabetes. Diabetologia 58(1), S526 (2015)
5.
Zurück zum Zitat Bressler, N.M., Edwards, A.R., Antoszyk, A.N., et al.: Retinal thickness on stratus Optical Coherence Tomography in people with diabetes and minimal or no diabetic retinopathy. Am. J. Ophthalmol. 145(5), 894–901 (2008)CrossRef Bressler, N.M., Edwards, A.R., Antoszyk, A.N., et al.: Retinal thickness on stratus Optical Coherence Tomography in people with diabetes and minimal or no diabetic retinopathy. Am. J. Ophthalmol. 145(5), 894–901 (2008)CrossRef
6.
Zurück zum Zitat Chen, X., Song, W., Cai, H., et al.: Macular edema after cataract surgery in diabetic eyes evaluated by optical coherence tomography. Int. J. Ophthalmol. 9(1), 81–85 (2016) Chen, X., Song, W., Cai, H., et al.: Macular edema after cataract surgery in diabetic eyes evaluated by optical coherence tomography. Int. J. Ophthalmol. 9(1), 81–85 (2016)
7.
Zurück zum Zitat Mokwa, N.F., Ristau, T., Keane, P.A., et al.: Grading of age-related macular degeneration: comparison between color fundus photography, fluorescein angiography, and spectral domain optical coherence tomography. J. Ophthalmol. (2013). Article ID 385915 Mokwa, N.F., Ristau, T., Keane, P.A., et al.: Grading of age-related macular degeneration: comparison between color fundus photography, fluorescein angiography, and spectral domain optical coherence tomography. J. Ophthalmol. (2013). Article ID 385915
9.
Zurück zum Zitat Lee, J.Y., Stephanie, J.C., Pratul, P.S., et al.: Fully automatic software for retinal thickness in eyes with diabetic macular edema from images acquired by cirrus and spectralis systems. Invest. Ophthalmol. Vis. Sci. 54(12), 7595–7602 (2013)CrossRef Lee, J.Y., Stephanie, J.C., Pratul, P.S., et al.: Fully automatic software for retinal thickness in eyes with diabetic macular edema from images acquired by cirrus and spectralis systems. Invest. Ophthalmol. Vis. Sci. 54(12), 7595–7602 (2013)CrossRef
10.
Zurück zum Zitat Chen, X., Niemeijer, M., Zhang, L., et al.: 3D segmentation of fluid-associated abnormalities in retinal OCT: probability constrained graph-search-graph-cut. IEEE Trans. Med. Imaging 31(8), 1521–1531 (2012)CrossRef Chen, X., Niemeijer, M., Zhang, L., et al.: 3D segmentation of fluid-associated abnormalities in retinal OCT: probability constrained graph-search-graph-cut. IEEE Trans. Med. Imaging 31(8), 1521–1531 (2012)CrossRef
11.
Zurück zum Zitat Lammer, J., Bolz, M., Baumann, B., Pircher, M., Gerendas, B., Schlanitz, F., Hitzenberger, C.K., Schmidt-Erfurth, U.: Detection and analysis of hard exudates by polarization-sensitive optical coherence tomography in patients with diabetic maculopathy. Invest. Ophthalmol. Vis. Sci. 55(3), 1564–1571 (2014)CrossRef Lammer, J., Bolz, M., Baumann, B., Pircher, M., Gerendas, B., Schlanitz, F., Hitzenberger, C.K., Schmidt-Erfurth, U.: Detection and analysis of hard exudates by polarization-sensitive optical coherence tomography in patients with diabetic maculopathy. Invest. Ophthalmol. Vis. Sci. 55(3), 1564–1571 (2014)CrossRef
12.
Zurück zum Zitat Stankiewicz, A., Marciniak, T., Dąbrowski, A., Stopa, M., Rakowicz, P., Marciniak, E.: Denoising methods for improving automatic segmentation in OCT images of human eye. Bull. Pol. Academic. Sci. Tech. Sci. 1 (2017) Stankiewicz, A., Marciniak, T., Dąbrowski, A., Stopa, M., Rakowicz, P., Marciniak, E.: Denoising methods for improving automatic segmentation in OCT images of human eye. Bull. Pol. Academic. Sci. Tech. Sci. 1 (2017)
13.
Zurück zum Zitat Esmaeili, M., Rabbani, H., Dehnavi, A.M., Dehghani, A.: Automatic detection of exudates and optic disk in retinal images using curvelet transform. IET Image Process. 6(7), 1005–1013 (2012)MathSciNetCrossRef Esmaeili, M., Rabbani, H., Dehnavi, A.M., Dehghani, A.: Automatic detection of exudates and optic disk in retinal images using curvelet transform. IET Image Process. 6(7), 1005–1013 (2012)MathSciNetCrossRef
14.
Zurück zum Zitat Rokade, P.M., Manza, R., Jonathan, P.: Computer aided hard exudates detection on digital fundus images using morphology and multi-resolution analysis. Int. J. Adv. Comput. Technol. (IJACT) 4(5), 20–27 (2015) Rokade, P.M., Manza, R., Jonathan, P.: Computer aided hard exudates detection on digital fundus images using morphology and multi-resolution analysis. Int. J. Adv. Comput. Technol. (IJACT) 4(5), 20–27 (2015)
15.
Zurück zum Zitat Ganesh Babua, T.R., Shenbaga Devi, S., Venkateshc, R.: Optic nerve head segmentation using fundus images and optical coherence tomography images for glaucoma detection. Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 159(4), 607–615 (2015) Ganesh Babua, T.R., Shenbaga Devi, S., Venkateshc, R.: Optic nerve head segmentation using fundus images and optical coherence tomography images for glaucoma detection. Biomed. Pap. Med. Fac. Univ. Palacky Olomouc Czech Repub. 159(4), 607–615 (2015)
Metadaten
Titel
A Novel Approach of Retinal Disorder Diagnosing Using Optical Coherence Tomography Scanners
verfasst von
Maciej Szymkowski
Emil Saeed
Copyright-Jahr
2018
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-56499-8_3