Skip to main content

2017 | Supplement | Buchkapitel

A Probe-Camera System for 3D Ultrasound Image Reconstruction

verfasst von : Koichi Ito, Kouya Yodokawa, Takafumi Aoki, Jun Ohmiya, Satoshi Kondo

Erschienen in: Imaging for Patient-Customized Simulations and Systems for Point-of-Care Ultrasound

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This paper proposes a probe-camera system for 3D ultrasound (US) image reconstruction with probe-camera calibration and probe localization methods. The probe-camera calibration method employs an existing US phantom for convenience with a simple procedure. The probe localization method employs structure from motion (SfM) to estimate the camera motion. SfM is used to reconstruct 3D point clouds from multiple-view images and simultaneously estimate each camera position. Through experiments using the developed system, we demonstrate that the proposed method exhibits good performance to reconstruct 3D US volume.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Fischler, M.A., Bolles, R.C.: Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Comm. ACM 24(6), 381–395 (1981)MathSciNetCrossRef Fischler, M.A., Bolles, R.C.: Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Comm. ACM 24(6), 381–395 (1981)MathSciNetCrossRef
2.
Zurück zum Zitat Gee, A., Prager, R., Treece, G., Berman, L.: Engineering a freehand 3D ultrasound system. Pattern Recogn. Lett. 24(4–5), 757–777 (2003)CrossRef Gee, A., Prager, R., Treece, G., Berman, L.: Engineering a freehand 3D ultrasound system. Pattern Recogn. Lett. 24(4–5), 757–777 (2003)CrossRef
3.
Zurück zum Zitat Goldsmith, A., Pedersen, P., Szabo, T.: An inertial-optical tracking system for portable, quantitative, 3D ultrasound. In: IEEE International Ultrasonics Symposium Proceedings, pp. 45–49 (2008) Goldsmith, A., Pedersen, P., Szabo, T.: An inertial-optical tracking system for portable, quantitative, 3D ultrasound. In: IEEE International Ultrasonics Symposium Proceedings, pp. 45–49 (2008)
4.
Zurück zum Zitat Hartley, R., Zisserman, A.: Multiple View Geometry. Cambridge University Press, Cambridge (2004)CrossRefMATH Hartley, R., Zisserman, A.: Multiple View Geometry. Cambridge University Press, Cambridge (2004)CrossRefMATH
5.
Zurück zum Zitat Hastenteufel, M., Vetter, M., Meinzer, H.P., Wolf, I.: Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems. Ultrasound Med. Biol. 32(9), 1359–1368 (2006)CrossRef Hastenteufel, M., Vetter, M., Meinzer, H.P., Wolf, I.: Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems. Ultrasound Med. Biol. 32(9), 1359–1368 (2006)CrossRef
6.
Zurück zum Zitat Horvath, S., et al.: Towards an ultrasound probe with vision: structured light to determine surface orientation. In: Linte, C.A., Moore, J.T., Chen, E.C.S., Holmes, D.R. (eds.) AE-CAI 2011. LNCS, vol. 7264, pp. 58–64. Springer, Heidelberg (2012). doi:10.1007/978-3-642-32630-1_6 CrossRef Horvath, S., et al.: Towards an ultrasound probe with vision: structured light to determine surface orientation. In: Linte, C.A., Moore, J.T., Chen, E.C.S., Holmes, D.R. (eds.) AE-CAI 2011. LNCS, vol. 7264, pp. 58–64. Springer, Heidelberg (2012). doi:10.​1007/​978-3-642-32630-1_​6 CrossRef
7.
Zurück zum Zitat Ishii, J., Sakai, S., Ito, K., Aoki, T., Yanagi, T., Ando, T.: 3D reconstruction of urban environments using in-vehicle fisheye camera. In: Proceedings of the IEEE International Conference on Image Processing, pp. 2145–2148, September 2013 Ishii, J., Sakai, S., Ito, K., Aoki, T., Yanagi, T., Ando, T.: 3D reconstruction of urban environments using in-vehicle fisheye camera. In: Proceedings of the IEEE International Conference on Image Processing, pp. 2145–2148, September 2013
8.
Zurück zum Zitat Ito, S., Ito, K., Aoki, T., Ohmiya, J., Kondo, S.: Probe localization using structure from motion for 3D ultrasound image reconstruction. In: Proceedings of the International Conference on Medical Imaging, pp. 68–71 (2017) Ito, S., Ito, K., Aoki, T., Ohmiya, J., Kondo, S.: Probe localization using structure from motion for 3D ultrasound image reconstruction. In: Proceedings of the International Conference on Medical Imaging, pp. 68–71 (2017)
9.
Zurück zum Zitat Kneip, L., Scaramuzza, D., Siegwart, R.: A novel parametrization of the perspective-three-point problem for a direct computation of absolute camera position and orientation. In: Proceedings of the International Conference Computer Vision and Pattern Recognition, pp. 2969–2976 (2011) Kneip, L., Scaramuzza, D., Siegwart, R.: A novel parametrization of the perspective-three-point problem for a direct computation of absolute camera position and orientation. In: Proceedings of the International Conference Computer Vision and Pattern Recognition, pp. 2969–2976 (2011)
10.
Zurück zum Zitat Lange, T., Kraft, S., Eulenstein, S., Lamecker, H., Schlag, P.: Automatic calibration of 3D ultrasound probes. In: Handels, H., Ehrhardt, J., Deserno, T., Meinzer, H.P., Tolxdorff, T. (eds.) Bildverarbeitung fur die Medizin 2011, pp. 169–173. Springer, Heidelberg (2011). doi:10.1007/978-3-642-19335-4_36 CrossRef Lange, T., Kraft, S., Eulenstein, S., Lamecker, H., Schlag, P.: Automatic calibration of 3D ultrasound probes. In: Handels, H., Ehrhardt, J., Deserno, T., Meinzer, H.P., Tolxdorff, T. (eds.) Bildverarbeitung fur die Medizin 2011, pp. 169–173. Springer, Heidelberg (2011). doi:10.​1007/​978-3-642-19335-4_​36 CrossRef
11.
Zurück zum Zitat Nistér, D.: An efficient solution to the five-point relative pose problem. IEEE Trans. Pattern Anal. Mach. Intell. 26(6), 756–770 (2004)CrossRef Nistér, D.: An efficient solution to the five-point relative pose problem. IEEE Trans. Pattern Anal. Mach. Intell. 26(6), 756–770 (2004)CrossRef
12.
Zurück zum Zitat Rafii-Tari, H., Abolmaesumi, P., Rohling, R.: Panorama ultrasound for guiding epidural anesthesia: a feasibility study. In: Taylor, R.H., Yang, G.-Z. (eds.) IPCAI 2011. LNCS, vol. 6689, pp. 179–189. Springer, Heidelberg (2011). doi:10.1007/978-3-642-21504-9_17 CrossRef Rafii-Tari, H., Abolmaesumi, P., Rohling, R.: Panorama ultrasound for guiding epidural anesthesia: a feasibility study. In: Taylor, R.H., Yang, G.-Z. (eds.) IPCAI 2011. LNCS, vol. 6689, pp. 179–189. Springer, Heidelberg (2011). doi:10.​1007/​978-3-642-21504-9_​17 CrossRef
13.
Zurück zum Zitat Rousseau, F., Hellier, P., Barillot, C.: A fully automatic calibration procedure for freehand 3D ultrasound. In: Proceedings of the IEEE International Symposium Biomedical, Imaging, pp. 985–988 (2002) Rousseau, F., Hellier, P., Barillot, C.: A fully automatic calibration procedure for freehand 3D ultrasound. In: Proceedings of the IEEE International Symposium Biomedical, Imaging, pp. 985–988 (2002)
14.
Zurück zum Zitat Shi, J., Tomasi, C.: Good features to track. In: Proceedings of the International Conference on Computer Vision and Pattern Recognition, pp. 593–600 (1994) Shi, J., Tomasi, C.: Good features to track. In: Proceedings of the International Conference on Computer Vision and Pattern Recognition, pp. 593–600 (1994)
15.
Zurück zum Zitat Stolka, P., Kang, H., Choti, M., Boctor, E.: Multi-DoF probe trajectory reconstruction with local sensors for 2D-to-3D ultrasound. In: Proceedings of the IEEE International Symposium Biomedical, Imaging, pp. 316–319 (2010) Stolka, P., Kang, H., Choti, M., Boctor, E.: Multi-DoF probe trajectory reconstruction with local sensors for 2D-to-3D ultrasound. In: Proceedings of the IEEE International Symposium Biomedical, Imaging, pp. 316–319 (2010)
16.
Zurück zum Zitat Sun, S.-Y., Gilbertson, M., Anthony, B.W.: Probe localization for freehand 3D ultrasound by tracking skin features. In: Golland, P., Hata, N., Barillot, C., Hornegger, J., Howe, R. (eds.) MICCAI 2014. LNCS, vol. 8674, pp. 365–372. Springer, Cham (2014). doi:10.1007/978-3-319-10470-6_46 Sun, S.-Y., Gilbertson, M., Anthony, B.W.: Probe localization for freehand 3D ultrasound by tracking skin features. In: Golland, P., Hata, N., Barillot, C., Hornegger, J., Howe, R. (eds.) MICCAI 2014. LNCS, vol. 8674, pp. 365–372. Springer, Cham (2014). doi:10.​1007/​978-3-319-10470-6_​46
18.
Zurück zum Zitat Takita, K., Muquit, M.A., Aoki, T., Higuchi, T.: A sub-pixel correspondence search for computer vision applications. IEICE Trans. Fundam. E87–A(8), 1913–1923 (2004) Takita, K., Muquit, M.A., Aoki, T., Higuchi, T.: A sub-pixel correspondence search for computer vision applications. IEICE Trans. Fundam. E87–A(8), 1913–1923 (2004)
19.
Zurück zum Zitat Zhang, Z.: Iterative point matching for registration of free-form curves and surfaces. Int. J. Comput. Vis. 13(2), 119–152 (1994)CrossRef Zhang, Z.: Iterative point matching for registration of free-form curves and surfaces. Int. J. Comput. Vis. 13(2), 119–152 (1994)CrossRef
Metadaten
Titel
A Probe-Camera System for 3D Ultrasound Image Reconstruction
verfasst von
Koichi Ito
Kouya Yodokawa
Takafumi Aoki
Jun Ohmiya
Satoshi Kondo
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-67552-7_16