Skip to main content

2014 | OriginalPaper | Buchkapitel

11. A Review on Radiant Cooling System in Buildings of China

verfasst von : Hongbin Wang, Haiwen Shu, Lin Duanmu

Erschienen in: Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The authors systematically summarized the research on the radiant cooling system in recent years. On the basis of a brief introduction of the radiant cooling system and its working principles, the advantages and disadvantages of the system were concluded compared with the conventional air conditioning system. The reasons for the slow development of radiant cooling system in China and its future trend were then discussed. It was suggested the solution to the condensation problem be focused on collecting and discharging the condensation water. This measure will not only improve the capacity of the radiant cooling system but also expand the application scope of the radiant cooling system.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Hu R, Niu J (2012) A review of the application of radiant cooling & heating systems in Mainland China. Energy Build 52:11–19CrossRef Hu R, Niu J (2012) A review of the application of radiant cooling & heating systems in Mainland China. Energy Build 52:11–19CrossRef
2.
Zurück zum Zitat Wang Z (2004) Radiant heating and raiant cooling. Chian Machine Press, Beijing Wang Z (2004) Radiant heating and raiant cooling. Chian Machine Press, Beijing
3.
Zurück zum Zitat Han G, Qu X (2011) An analysis of radiant cooling with displacement ventilation composite system. ChengShi Jianshe LiLun Yan Jiu 22 Han G, Qu X (2011) An analysis of radiant cooling with displacement ventilation composite system. ChengShi Jianshe LiLun Yan Jiu 22
4.
Zurück zum Zitat Chen L, Liao S (2010) Three approaches to the comparative study of indoor thermal environment for radiant cooling system. Build Energy Environ 29(3):53–56MATHMathSciNet Chen L, Liao S (2010) Three approaches to the comparative study of indoor thermal environment for radiant cooling system. Build Energy Environ 29(3):53–56MATHMathSciNet
5.
Zurück zum Zitat Lu S, Zhang S (2011) Theory study on condensation problem of floor radiant cooling system. J Jiangsu Univ Sci Technol (Nat Sci Ed) 25(6):565–571 Lu S, Zhang S (2011) Theory study on condensation problem of floor radiant cooling system. J Jiangsu Univ Sci Technol (Nat Sci Ed) 25(6):565–571
6.
Zurück zum Zitat Shi Y, Chen Y et al (2011) Air quality of radiant cooling combined with wall-attached-jet system. HV&AC 41(2):60–63 Shi Y, Chen Y et al (2011) Air quality of radiant cooling combined with wall-attached-jet system. HV&AC 41(2):60–63
7.
Zurück zum Zitat Zhou G, Shi Y et al (2011) Studies of anti-condensation of the radiant cooling system with wall-attached-jet. Build Energy Environ 30(5):20–22 Zhou G, Shi Y et al (2011) Studies of anti-condensation of the radiant cooling system with wall-attached-jet. Build Energy Environ 30(5):20–22
8.
Zurück zum Zitat Xiao Y, Fu X (2002) Dehumidifying capability of outdoor air in cooling ceiling system application. HV&AC 32(3):15–17 Xiao Y, Fu X (2002) Dehumidifying capability of outdoor air in cooling ceiling system application. HV&AC 32(3):15–17
9.
Zurück zum Zitat Xia X, Zhang X et al (2008) Technology analysis and experimental research on radiant floor cooling combined with dedicated outdoor air system. J Refrig 29(4):18–23 Xia X, Zhang X et al (2008) Technology analysis and experimental research on radiant floor cooling combined with dedicated outdoor air system. J Refrig 29(4):18–23
10.
Zurück zum Zitat He J, Shen J et al (2008) Discussion on condensation of radiant cooling system combined with DOAS. HV&AC 38(6):159–162 He J, Shen J et al (2008) Discussion on condensation of radiant cooling system combined with DOAS. HV&AC 38(6):159–162
11.
Zurück zum Zitat Zhang B, Song L, Wang J (2009) Experimental study on cooling ceiling air-conditioning system covered and airproofed with the film whose long wave transmittance (LWT) is high. CC&AC 3:23–26 Zhang B, Song L, Wang J (2009) Experimental study on cooling ceiling air-conditioning system covered and airproofed with the film whose long wave transmittance (LWT) is high. CC&AC 3:23–26
12.
Zurück zum Zitat Kong X, Zhang X, Lu S (2008) Research status of condensation of radiant cooling and its countermeasures. Build Energy Environ 27(1):20–23 Kong X, Zhang X, Lu S (2008) Research status of condensation of radiant cooling and its countermeasures. Build Energy Environ 27(1):20–23
13.
Zurück zum Zitat Kong X, Zhang D, Zhang X (2011) Design and analysis of leading condensation radiant panel. J Jiangsu Univ Sci Technol (Nat Sci Ed) 25(5):440–446MathSciNet Kong X, Zhang D, Zhang X (2011) Design and analysis of leading condensation radiant panel. J Jiangsu Univ Sci Technol (Nat Sci Ed) 25(5):440–446MathSciNet
14.
Zurück zum Zitat Liu J, Wu Z et al (2010) Radiant ceiling system design and research for EXPO Hamburg Haus. Refrig Air-conditioning 10(3):94–97 Liu J, Wu Z et al (2010) Radiant ceiling system design and research for EXPO Hamburg Haus. Refrig Air-conditioning 10(3):94–97
15.
Zurück zum Zitat Fan L, He K, Wan S (2005) Study and application of floor panel heating/cooling system in lobbies of Wukesong Gymnasium. HV&AV 35(6):87–90 Fan L, He K, Wan S (2005) Study and application of floor panel heating/cooling system in lobbies of Wukesong Gymnasium. HV&AV 35(6):87–90
16.
Zurück zum Zitat Zou Z, Li G, Zhu J (2010) Design of air conditioning system for tianjin railway station. HV&AC 40(5):32–35MathSciNet Zou Z, Li G, Zhu J (2010) Design of air conditioning system for tianjin railway station. HV&AC 40(5):32–35MathSciNet
17.
Zurück zum Zitat Lu S, Lv Y et al (2010) Numerical simulation and experiment research for radiant cooling-displacement ventilation system. Build Energy Environ 29(2):25–29 Lu S, Lv Y et al (2010) Numerical simulation and experiment research for radiant cooling-displacement ventilation system. Build Energy Environ 29(2):25–29
18.
Zurück zum Zitat Xuan Y, Wang H, Huang X (2012) Simulation analysis of radiation floor with displacement ventilation air conditioning system by energyplus. Fluid Mach 40(8):65–68 Xuan Y, Wang H, Huang X (2012) Simulation analysis of radiation floor with displacement ventilation air conditioning system by energyplus. Fluid Mach 40(8):65–68
19.
Zurück zum Zitat Yan Z (2010) Discussion on combined air- conditioning system based on radiant heating and cooling with evaporative cooling. Refrigeration 114:18–23 Yan Z (2010) Discussion on combined air- conditioning system based on radiant heating and cooling with evaporative cooling. Refrigeration 114:18–23
20.
Zurück zum Zitat Gao Z, Liu X, Jiang Y (2011) Experiment study on cooling capacity of capillary-tube radiation air-conditioner. Acta Energiae Solaris Sinica 32(2):101–106MATH Gao Z, Liu X, Jiang Y (2011) Experiment study on cooling capacity of capillary-tube radiation air-conditioner. Acta Energiae Solaris Sinica 32(2):101–106MATH
21.
Zurück zum Zitat Gao Z, Liu X et al (2011) Influence factors and calculation method of radiant panel cooling capacity. HV&AC 41(1):33–37 Gao Z, Liu X et al (2011) Influence factors and calculation method of radiant panel cooling capacity. HV&AC 41(1):33–37
22.
Zurück zum Zitat Zhang L, Liu X et al (2012) Simplified calculation method for the cooling capacity and surface temperature distribution of floor panel. HV&AV 42(5):41–46 Zhang L, Liu X et al (2012) Simplified calculation method for the cooling capacity and surface temperature distribution of floor panel. HV&AV 42(5):41–46
23.
Zurück zum Zitat Fong KF, Chow TT et al (2011) Solar hybrid cooling system for high-tech offices in subtropical climate—Radiant cooling by absorption refrigeration and desiccant dehumidification. Energy Convers Manage 52:2883–2894CrossRef Fong KF, Chow TT et al (2011) Solar hybrid cooling system for high-tech offices in subtropical climate—Radiant cooling by absorption refrigeration and desiccant dehumidification. Energy Convers Manage 52:2883–2894CrossRef
24.
Zurück zum Zitat De Carli M, Massimo T (2011) Effect of modelling solar radiation on the cooling performance of radiant floors. ScienceDirect 85:689–712 De Carli M, Massimo T (2011) Effect of modelling solar radiation on the cooling performance of radiant floors. ScienceDirect 85:689–712
25.
Zurück zum Zitat Doosam S, Taeyeon K et al (2008) Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. ScienceDirect 28:1299–1311 Doosam S, Taeyeon K et al (2008) Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. ScienceDirect 28:1299–1311
26.
Zurück zum Zitat Corina S (1999) Energy and peak power savings potential of radiant cooling systems in US commercial buildings. Energy Build 30:127–138CrossRef Corina S (1999) Energy and peak power savings potential of radiant cooling systems in US commercial buildings. Energy Build 30:127–138CrossRef
27.
Zurück zum Zitat Suya W, Megumi M (2008) Evaluating the low exergy of chilled water in a radiant cooling system. Energy Build 40:1856–1865CrossRef Suya W, Megumi M (2008) Evaluating the low exergy of chilled water in a radiant cooling system. Energy Build 40:1856–1865CrossRef
28.
Zurück zum Zitat Prapapong V, Surapong C (2007) Application of radiant cooling as a passive cooling option in hot humid climate. ScienceDirect 42:543–556 Prapapong V, Surapong C (2007) Application of radiant cooling as a passive cooling option in hot humid climate. ScienceDirect 42:543–556
29.
Zurück zum Zitat Simos O, Agis MP (2013) Performance of radiant cooling surfaces with respect to energy consumption and thermal comfort. Energy Build 57:199–209CrossRef Simos O, Agis MP (2013) Performance of radiant cooling surfaces with respect to energy consumption and thermal comfort. Energy Build 57:199–209CrossRef
Metadaten
Titel
A Review on Radiant Cooling System in Buildings of China
verfasst von
Hongbin Wang
Haiwen Shu
Lin Duanmu
Copyright-Jahr
2014
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-642-39581-9_11