Skip to main content
Erschienen in: Experiments in Fluids 3/2005

01.03.2005 | Originals

A simple model for the effect of peak-locking on the accuracy of boundary layer turbulence statistics in digital PIV

verfasst von: K. P. Angele, B. Muhammad-Klingmann

Erschienen in: Experiments in Fluids | Ausgabe 3/2005

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A simple model was constructed to study the effect of peak-locking on the accuracy of particle image velocimetry (PIV) turbulence statistics. A crucial parameter is the ratio between the root-mean-square (rms) velocity and the discretization velocity, which reflects the number of peaks distributed over the velocity probability density functions. When the ratio of the discretization velocity, which is set by the PIV setup parameters, to the rms, given by the flow, is larger than two, the maximum errors introduced in the mean and rms values become significant (larger than 1%). The errors introduced also depend on the amplitude, or severity, of the peak-locking, and whether the mean displacement corresponds to an integer or a fractional number of pixels. The peak-locking affects the statistical moments of different order in such a way that the errors are phase shifted. The proposed model can be used to predict errors in the turbulence statistics in a laboratory PIV experiment. According to our model predictions, the most significant influence of peak-locking in a boundary layer type of flow is an overall underestimation of the wall-normal rms. Our predictions are in good agreement with our experimental results from turbulent boundary layers and the recent experimental results from a turbulent channel flow by Christensen (Exp Fluids 36:484–497, 2004) for a case of moderate peak-locking.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
Olga Lögdberg at KTH is highly acknowledged for these data.
 
Literatur
Zurück zum Zitat Angele K, Muhammad-Klingmann B (2000) PIV measurements in a high Re turbulent boundary layer. In: Proceedings of the 8th European turbulence conference (ETC8), Barcelona, Spain, June 2000 Angele K, Muhammad-Klingmann B (2000) PIV measurements in a high Re turbulent boundary layer. In: Proceedings of the 8th European turbulence conference (ETC8), Barcelona, Spain, June 2000
Zurück zum Zitat Christensen KT (2004) The influence of peak-locking errors on turbulence statistics computed from PIV ensembles. Exp Fluids 36:484–497CrossRef Christensen KT (2004) The influence of peak-locking errors on turbulence statistics computed from PIV ensembles. Exp Fluids 36:484–497CrossRef
Zurück zum Zitat Fincham AM, Delerce G (2000) Advanced optimization of correlation imaging velocimetry algorithms. Exp Fluids 29:S13–S22CrossRef Fincham AM, Delerce G (2000) Advanced optimization of correlation imaging velocimetry algorithms. Exp Fluids 29:S13–S22CrossRef
Zurück zum Zitat Gui L, Wereley ST (2002) A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital PIV image evaluation. Exp Fluids 23:20–28 Gui L, Wereley ST (2002) A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital PIV image evaluation. Exp Fluids 23:20–28
Zurück zum Zitat Iwamoto K, Suzuki Y, Kasagi N (2002) Reynolds number effect on wall turbulence: toward effective feedback control. Int J Heat Fluid Flow 23:678–689CrossRef Iwamoto K, Suzuki Y, Kasagi N (2002) Reynolds number effect on wall turbulence: toward effective feedback control. Int J Heat Fluid Flow 23:678–689CrossRef
Zurück zum Zitat Nogueira J, Lecuona A, Rodriguez PA (2001) Identification of a new source of peak locking, analysis and its removal in conventional and super-resolution PIV techniques. Exp Fluids 30:309–316CrossRef Nogueira J, Lecuona A, Rodriguez PA (2001) Identification of a new source of peak locking, analysis and its removal in conventional and super-resolution PIV techniques. Exp Fluids 30:309–316CrossRef
Zurück zum Zitat Österlund JM (1999) Experimental studies of zero pressure-gradient turbulent boundary-layer flow. PhD thesis, Department of Mechanics, Royal Institute of Technology, Stockholm Österlund JM (1999) Experimental studies of zero pressure-gradient turbulent boundary-layer flow. PhD thesis, Department of Mechanics, Royal Institute of Technology, Stockholm
Zurück zum Zitat Österlund JM, Johansson AV, Nagib HM (2000a) Comment on “A note on the intermediate region in turbulent boundary layers.” Phys Fluids 12(9):2360–2363CrossRef Österlund JM, Johansson AV, Nagib HM (2000a) Comment on “A note on the intermediate region in turbulent boundary layers.” Phys Fluids 12(9):2360–2363CrossRef
Zurück zum Zitat Österlund JM, Johansson AV, Nagib HM, Hites MH (2000) A note on the overlap region in turbulent boundary layers. Phys Fluids 12:1–4 Österlund JM, Johansson AV, Nagib HM, Hites MH (2000) A note on the overlap region in turbulent boundary layers. Phys Fluids 12:1–4
Zurück zum Zitat Raffel M, Willert C, Kompenhans J (1998) Particle image velocimetry: a practical guide. Springer, Berlin Heidelberg New York Raffel M, Willert C, Kompenhans J (1998) Particle image velocimetry: a practical guide. Springer, Berlin Heidelberg New York
Zurück zum Zitat Scarano F, Riethmuller ML (2000) Advances in iterative multigrid PIV image processing. Exp in Fluids 29:S051–S060CrossRef Scarano F, Riethmuller ML (2000) Advances in iterative multigrid PIV image processing. Exp in Fluids 29:S051–S060CrossRef
Zurück zum Zitat Westerweel J, Draad A, van der Hoeven J, van Oord J (1996) Measurements of fully-developed turbulent pipe flow with digital particle image velocimetry. Exp Fluids 20:165–177CrossRef Westerweel J, Draad A, van der Hoeven J, van Oord J (1996) Measurements of fully-developed turbulent pipe flow with digital particle image velocimetry. Exp Fluids 20:165–177CrossRef
Zurück zum Zitat Westerweel J, Daribi D, Gharib M (1997) The effect of a discrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings. Exp Fluids 23:20–28 Westerweel J, Daribi D, Gharib M (1997) The effect of a discrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings. Exp Fluids 23:20–28
Metadaten
Titel
A simple model for the effect of peak-locking on the accuracy of boundary layer turbulence statistics in digital PIV
verfasst von
K. P. Angele
B. Muhammad-Klingmann
Publikationsdatum
01.03.2005
Erschienen in
Experiments in Fluids / Ausgabe 3/2005
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-004-0908-x

Weitere Artikel der Ausgabe 3/2005

Experiments in Fluids 3/2005 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.