Skip to main content
Erschienen in: Journal of Nanoparticle Research 7/2019

01.07.2019 | Research Paper

Amperometric cholesterol biosensor based on reduction graphene oxide-chitosan-ferrocene/platinum nanoparticles modified screen-printed electrode

verfasst von: Guiyin Li, Junxiang Zeng, Le Zhao, Zhihong Wang, Chenyang Dong, Jintao Liang, Zhide Zhou, Yong Huang

Erschienen in: Journal of Nanoparticle Research | Ausgabe 7/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Cholesterol is a waxy steroid metabolite substance and plays an important role in the brain, nervous, and immune systems of humans. The level of cholesterol in human serum has become an important index for clinical diagnosis and prevention of cardiovascular disease. In this study, a highly sensitive electrochemical biosensor for cholesterol measurement has been developed based on reduced graphene oxide-chitosan-ferrocene carboxylic acid/platinum nanoparticle (RGO-CS-Fc/Pt NPs) modified screen-printed carbon electrode (SPCE). Under the effect of cholesterol oxidase (CHOD) and cholesterol esterase (CHER), the cholesterol was oxidized to generate hydrogen peroxide (H2O2), which can be disintegrated into H2O with the synergistic catalysis of RGO-CS-Fc/Pt NPs and produce the redox response current of H2O2 that could be determined by electrochemical amperometric (i-t) method. The prepared cholesterol biosensor was achieved by integrating of the high electrocatalytic efficiency of Pt NPs, high electronic conductivity and large surface area of RGO, the reversible electrochemical behavior of Fc, and good biocompatibility of CS. The measured of redox response current and cholesterol concentration have a good linearity in the range of 0.5–4.0 mg/mL, low detection limit of 5.70 μg/mL (S/N = 3), and good sensitivity of 0.871 nA/mM/cm2. Moreover, the RGO-CS-Fc/Pt NPs cholesterol biosensor exhibited excellent specificity, acceptable reproducibility, and higher recoveries in the detection of clinical serum samples, showing great potential for clinical diagnosis.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Ahmad R, Tripathy N, Kim SH, Umar A, Al-Hajry A, Hahn YB (2014) High performance cholesterol sensor based on ZnO nanotubes grown on Si/Ag electrodes. Electrochem Commun 38:4–7CrossRef Ahmad R, Tripathy N, Kim SH, Umar A, Al-Hajry A, Hahn YB (2014) High performance cholesterol sensor based on ZnO nanotubes grown on Si/Ag electrodes. Electrochem Commun 38:4–7CrossRef
Zurück zum Zitat Arya SK, Datta M, Malhotra DB (2008) Recent advances in cholesterol biosens. Bioelectron 23:1083–1100CrossRef Arya SK, Datta M, Malhotra DB (2008) Recent advances in cholesterol biosens. Bioelectron 23:1083–1100CrossRef
Zurück zum Zitat Bai ZH, Li GY, Liang JT, Su J, Zhang Y, Chen HZ, Huang Y, Sui WG, Zhao YX (2016) Non-enzymatic electrochemical biosensor based on Pt NPs/RGO-CS-Fc nano-hybrids for the detection of hydrogen peroxide in living cells. Biosens Bioelectron 82:185–194CrossRef Bai ZH, Li GY, Liang JT, Su J, Zhang Y, Chen HZ, Huang Y, Sui WG, Zhao YX (2016) Non-enzymatic electrochemical biosensor based on Pt NPs/RGO-CS-Fc nano-hybrids for the detection of hydrogen peroxide in living cells. Biosens Bioelectron 82:185–194CrossRef
Zurück zum Zitat Bairagi PK, Verma N (2018) Electrochemically deposited dendritic poly (methyl orange) nanofilm on metal-carbon-polymer nanocomposite: a novel non-enzymatic electrochemical biosensor for cholesterol. J Electroanal Chem 814:134–143CrossRef Bairagi PK, Verma N (2018) Electrochemically deposited dendritic poly (methyl orange) nanofilm on metal-carbon-polymer nanocomposite: a novel non-enzymatic electrochemical biosensor for cholesterol. J Electroanal Chem 814:134–143CrossRef
Zurück zum Zitat Batra N, Tomar M, Gupta V (2015) ZnO-CuO composite matrix based reagentless biosensor for detection of Total cholesterol. Biosens Bioelectron 67:263–271CrossRef Batra N, Tomar M, Gupta V (2015) ZnO-CuO composite matrix based reagentless biosensor for detection of Total cholesterol. Biosens Bioelectron 67:263–271CrossRef
Zurück zum Zitat Fan L, Zhang Q, Wang K, Li F, Niu L (2012) Ferrocene functionalized graphene: preparation, characterization and efficient Electron transfer toward sensors of H2O2. J Mater Chem 22:6165–6170CrossRef Fan L, Zhang Q, Wang K, Li F, Niu L (2012) Ferrocene functionalized graphene: preparation, characterization and efficient Electron transfer toward sensors of H2O2. J Mater Chem 22:6165–6170CrossRef
Zurück zum Zitat Hassanzadeh J, Khataee A, Eskandari H (2018) Encapsulated cholesterol oxidase in metal-organic framework and biomimetic ag nanocluster decorated MoS2 nanosheets for sensitive detection of cholesterol. Sens Actuator B-Chem 259:402–410CrossRef Hassanzadeh J, Khataee A, Eskandari H (2018) Encapsulated cholesterol oxidase in metal-organic framework and biomimetic ag nanocluster decorated MoS2 nanosheets for sensitive detection of cholesterol. Sens Actuator B-Chem 259:402–410CrossRef
Zurück zum Zitat Hsieh C, Chena Y, Hwang DW (2013) Effects of cholesterol on membrane molecular dynamics studied by fast field cycling NMR relaxometry. Phys Chem Chem Phys 13:16634–16640CrossRef Hsieh C, Chena Y, Hwang DW (2013) Effects of cholesterol on membrane molecular dynamics studied by fast field cycling NMR relaxometry. Phys Chem Chem Phys 13:16634–16640CrossRef
Zurück zum Zitat Huan J, Liu Q, Fei A, Qian J, Dong X, Qiu B, Mao H, Wang K (2015) Amplified solid-state electrochemiluminescence detection of cholesterol in near-infrared range based on CdTe quantum dots decorated multiwalled carbon nanotubes@reduced graphene oxide nanoribbons. Biosens Bioelectron 73:221–227CrossRef Huan J, Liu Q, Fei A, Qian J, Dong X, Qiu B, Mao H, Wang K (2015) Amplified solid-state electrochemiluminescence detection of cholesterol in near-infrared range based on CdTe quantum dots decorated multiwalled carbon nanotubes@reduced graphene oxide nanoribbons. Biosens Bioelectron 73:221–227CrossRef
Zurück zum Zitat Huang Y, Xue YW, Zeng JX, Li SS, Wang ZH, Dong CY, Li GY, Liang JT, Zhou ZD (2018) Non-enzymatic electrochemical hydrogen peroxide biosensor based on reduction graphene oxide-persimmon tannin-platinum nanocomposite. Mater Sci Eng C Mater Biol Appl 92:590–598CrossRef Huang Y, Xue YW, Zeng JX, Li SS, Wang ZH, Dong CY, Li GY, Liang JT, Zhou ZD (2018) Non-enzymatic electrochemical hydrogen peroxide biosensor based on reduction graphene oxide-persimmon tannin-platinum nanocomposite. Mater Sci Eng C Mater Biol Appl 92:590–598CrossRef
Zurück zum Zitat Karthick NA, Thangappan R, Arivanandhan M, Gnanamani A, Jayavel R (2018) A facile synthesis of ferrocene functionalized graphene oxide nanocomposite for electrochemical sensing of lead. J Inorg Organomet Polym Mater 28:1021–1028CrossRef Karthick NA, Thangappan R, Arivanandhan M, Gnanamani A, Jayavel R (2018) A facile synthesis of ferrocene functionalized graphene oxide nanocomposite for electrochemical sensing of lead. J Inorg Organomet Polym Mater 28:1021–1028CrossRef
Zurück zum Zitat Kaur G, Tomar M, Gupta V (2018) Development of a microfluidic electrochemical biosensor: prospect for point-of-care cholesterol monitoring. Sensors Actuator B Chem 261:460–466CrossRef Kaur G, Tomar M, Gupta V (2018) Development of a microfluidic electrochemical biosensor: prospect for point-of-care cholesterol monitoring. Sensors Actuator B Chem 261:460–466CrossRef
Zurück zum Zitat Li C, Wu Z, Yang H, Deng L, Chen X (2017) Reduced graphene oxide-cyclodextrin-chitosan electrochemical sensor: effective and simultaneous determination of o- and p-nitrophenols. Sensors Actuator B Chem 251:446–454CrossRef Li C, Wu Z, Yang H, Deng L, Chen X (2017) Reduced graphene oxide-cyclodextrin-chitosan electrochemical sensor: effective and simultaneous determination of o- and p-nitrophenols. Sensors Actuator B Chem 251:446–454CrossRef
Zurück zum Zitat Liu J, Yang C, Shang Y, Zhang P, Liu J, Zheng J (2018) Preparation of a nanocomposite material consisting of cuprous oxide, polyaniline and reduced graphene oxide, and its application to the electrochemical determination of hydrogen peroxide. Microchim Acta 185(3):172–179CrossRef Liu J, Yang C, Shang Y, Zhang P, Liu J, Zheng J (2018) Preparation of a nanocomposite material consisting of cuprous oxide, polyaniline and reduced graphene oxide, and its application to the electrochemical determination of hydrogen peroxide. Microchim Acta 185(3):172–179CrossRef
Zurück zum Zitat Novak A, Gutiérrez-Zamora M, Domenech L, Suñé-Negre JM, Miñarro M, García-Montoya E, Llop JM, Ticó JR, Pérez-Lozano P (2018) Development and validation of a simple high-performance liquid chromatography analytical method for simultaneous determination of phytosterols, cholesterol and squalene in parenteral lipid emulsions. Biomed Chromatogr 32(2):4084–4092CrossRef Novak A, Gutiérrez-Zamora M, Domenech L, Suñé-Negre JM, Miñarro M, García-Montoya E, Llop JM, Ticó JR, Pérez-Lozano P (2018) Development and validation of a simple high-performance liquid chromatography analytical method for simultaneous determination of phytosterols, cholesterol and squalene in parenteral lipid emulsions. Biomed Chromatogr 32(2):4084–4092CrossRef
Zurück zum Zitat Qiu J, Huang J, Liang R (2011) Nanocomposite film based on graphene oxide for high performance flexible glucose biosensor. Sensors Actuator B Chem 160:287–294CrossRef Qiu J, Huang J, Liang R (2011) Nanocomposite film based on graphene oxide for high performance flexible glucose biosensor. Sensors Actuator B Chem 160:287–294CrossRef
Zurück zum Zitat Qureshi RN, Kaal E, Janssen HG, Schoenmakers PJ, Kok WT (2011) Determination of cholesterol and triglycerides in serum lipoproteins using flow field-flow fractionation coupled to gas chromatography-mass spectrometry. Anal Chim Acta 706:361–366CrossRef Qureshi RN, Kaal E, Janssen HG, Schoenmakers PJ, Kok WT (2011) Determination of cholesterol and triglycerides in serum lipoproteins using flow field-flow fractionation coupled to gas chromatography-mass spectrometry. Anal Chim Acta 706:361–366CrossRef
Zurück zum Zitat Rajabzadeh S, Rounaghi GH, Arbab-Zavar MH, Ashraf N (2014) Development of a dimethyl disulfide electrochemical sensor based on electrodeposited reduced graphene oxide-chitosan modified glassy carbon electrode. Electrochim Acta 135:543–549CrossRef Rajabzadeh S, Rounaghi GH, Arbab-Zavar MH, Ashraf N (2014) Development of a dimethyl disulfide electrochemical sensor based on electrodeposited reduced graphene oxide-chitosan modified glassy carbon electrode. Electrochim Acta 135:543–549CrossRef
Zurück zum Zitat Razzazi-Fazeli E, Kleineisen S, Luf W (2000) Determination of cholesterol qxides in processed food using highperformance liquid chromatography–mass spectrometry with atmospheric pressure chemical ionization. J Chromatogr A 896:321–334CrossRef Razzazi-Fazeli E, Kleineisen S, Luf W (2000) Determination of cholesterol qxides in processed food using highperformance liquid chromatography–mass spectrometry with atmospheric pressure chemical ionization. J Chromatogr A 896:321–334CrossRef
Zurück zum Zitat Ruecha N, Siangproh W, Chailapakul O (2011) A fast and highly sensitive detection of cholesterol using polymer microfluidic devices and amperometric system. Talanta 84(5):1323–1328CrossRef Ruecha N, Siangproh W, Chailapakul O (2011) A fast and highly sensitive detection of cholesterol using polymer microfluidic devices and amperometric system. Talanta 84(5):1323–1328CrossRef
Zurück zum Zitat Sharma D, Lee J, Seo J, Shin H (2017) Development of a sensitive electrochemical enzymatic reaction-based cholesterol biosensor using nano-sized carbon interdigitated electrodes decorated with gold nanoparticles. Sensors 17:2128–2143CrossRef Sharma D, Lee J, Seo J, Shin H (2017) Development of a sensitive electrochemical enzymatic reaction-based cholesterol biosensor using nano-sized carbon interdigitated electrodes decorated with gold nanoparticles. Sensors 17:2128–2143CrossRef
Zurück zum Zitat Shrestha BK, Ahmad R, Shrestha S, Park CH, Kim CS (2017) In situ synthesis of cylindrical spongy polypyrrole doped protonated graphitic carbon nitride for cholesterol sensing application. Biosens Bioelectron 94:686–693CrossRef Shrestha BK, Ahmad R, Shrestha S, Park CH, Kim CS (2017) In situ synthesis of cylindrical spongy polypyrrole doped protonated graphitic carbon nitride for cholesterol sensing application. Biosens Bioelectron 94:686–693CrossRef
Zurück zum Zitat Soorya VC, Berchmans S (2016) Flower like bi structures on Pt surface facilitating effective cholesterol biosensing. Mater Sci Eng C Mater Biol Appl 64:183–189CrossRef Soorya VC, Berchmans S (2016) Flower like bi structures on Pt surface facilitating effective cholesterol biosensing. Mater Sci Eng C Mater Biol Appl 64:183–189CrossRef
Zurück zum Zitat Soylemez S, Udum YA, Kesik M, Hizliates CG, Ergun Y, Toppare L (2015) Electrochemical and optical properties of a conducting polymer and its use in a novel biosensor for the detection of cholesterol. Sensors Actuator B Chem 212:425–433CrossRef Soylemez S, Udum YA, Kesik M, Hizliates CG, Ergun Y, Toppare L (2015) Electrochemical and optical properties of a conducting polymer and its use in a novel biosensor for the detection of cholesterol. Sensors Actuator B Chem 212:425–433CrossRef
Zurück zum Zitat Wang C, Tan X, Chen S, Yuan R, Hu F, Yuan D, Xiang Y (2012) Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods. Talanta 94:263–270CrossRef Wang C, Tan X, Chen S, Yuan R, Hu F, Yuan D, Xiang Y (2012) Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods. Talanta 94:263–270CrossRef
Zurück zum Zitat Wang L, Zhang YY, Cheng CS, Liu XL, Jiang H, Wang XM (2015) Highly sensitive electrochemical biosensor for evaluation of oxidative stress based on the nanointerface of graphene nanocomposites blended with gold, Fe3O4, and platinum nanoparticles. ACS Appl Mater Interfaces 7:18441–18449CrossRef Wang L, Zhang YY, Cheng CS, Liu XL, Jiang H, Wang XM (2015) Highly sensitive electrochemical biosensor for evaluation of oxidative stress based on the nanointerface of graphene nanocomposites blended with gold, Fe3O4, and platinum nanoparticles. ACS Appl Mater Interfaces 7:18441–18449CrossRef
Zurück zum Zitat Wang Z, Xie F, Liu Z, Du G, Asiri AM, Sun X (2017) High-performance non-enzyme hydrogen peroxide detection in neutral solution: using a nickel borate nanoarray as a 3D electrochemical sensor. Chemistry 23(64):16179–16183CrossRef Wang Z, Xie F, Liu Z, Du G, Asiri AM, Sun X (2017) High-performance non-enzyme hydrogen peroxide detection in neutral solution: using a nickel borate nanoarray as a 3D electrochemical sensor. Chemistry 23(64):16179–16183CrossRef
Zurück zum Zitat Wisitsoraat A, Karuwan C, Wong-Ek K, Phokharatkul D, Sritongkham P, Tuantranont A (2009) High sensitivity electrochemical cholesterol sensor utilizing a vertically aligned carbon nanotube electrode with electropolymerized enzyme immobilization. Sensors 9:8658–8668CrossRef Wisitsoraat A, Karuwan C, Wong-Ek K, Phokharatkul D, Sritongkham P, Tuantranont A (2009) High sensitivity electrochemical cholesterol sensor utilizing a vertically aligned carbon nanotube electrode with electropolymerized enzyme immobilization. Sensors 9:8658–8668CrossRef
Zurück zum Zitat Wu ZM, Zhang L, Guan QQ, Ning P, Ye DQ (2014) Preparation of alpha-zirconium phosphate-pillared reduced graphene oxide with increased adsorption towards methylene blue. Chem Eng J 258:77–84CrossRef Wu ZM, Zhang L, Guan QQ, Ning P, Ye DQ (2014) Preparation of alpha-zirconium phosphate-pillared reduced graphene oxide with increased adsorption towards methylene blue. Chem Eng J 258:77–84CrossRef
Zurück zum Zitat Yang JH, Myoung N, Hong HG (2012) Facile and controllable synthesis of Prussian blue on chitosan-functionalized graphene nanosheets for the electrochemical detection of hydrogen peroxide. Electrochim Acta 81:37–43CrossRef Yang JH, Myoung N, Hong HG (2012) Facile and controllable synthesis of Prussian blue on chitosan-functionalized graphene nanosheets for the electrochemical detection of hydrogen peroxide. Electrochim Acta 81:37–43CrossRef
Zurück zum Zitat Yang M, Kim DS, Lee TJ, Lee SJ, Lee KG, Choi BG (2016) Polyoxometalate-grafted graphene nanohybrid for electrochemical detection of hydrogen peroxide and glucose. J Colloid Interface Sci 468:51–56CrossRef Yang M, Kim DS, Lee TJ, Lee SJ, Lee KG, Choi BG (2016) Polyoxometalate-grafted graphene nanohybrid for electrochemical detection of hydrogen peroxide and glucose. J Colloid Interface Sci 468:51–56CrossRef
Zurück zum Zitat Yang Y, Liu Q, Liu Y, Cui J, Liu H, Wang P, Li Y, Chen L, Zhao Z, Dong Y (2017) A novel label-free electrochemical immunosensor based on functionalized nitrogen-doped graphene quantum dots for carcinoembryonic antigen detection. Biosens Bioelectron 90:31–38CrossRef Yang Y, Liu Q, Liu Y, Cui J, Liu H, Wang P, Li Y, Chen L, Zhao Z, Dong Y (2017) A novel label-free electrochemical immunosensor based on functionalized nitrogen-doped graphene quantum dots for carcinoembryonic antigen detection. Biosens Bioelectron 90:31–38CrossRef
Zurück zum Zitat Yang S, Zhang F, Wang Z, Liang Q (2018) A graphene oxide-based label-free electrochemical aptasensor for the detection of alpha-fetoprotein. Biosens Bioelectron 112:186–192CrossRef Yang S, Zhang F, Wang Z, Liang Q (2018) A graphene oxide-based label-free electrochemical aptasensor for the detection of alpha-fetoprotein. Biosens Bioelectron 112:186–192CrossRef
Zurück zum Zitat Yildirimoglu F, Arslan F, Cete S, Yasar A (2009) Preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of cholesterol based on entrapment of cholesterol oxidase. Sensors 9:6435–6445CrossRef Yildirimoglu F, Arslan F, Cete S, Yasar A (2009) Preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of cholesterol based on entrapment of cholesterol oxidase. Sensors 9:6435–6445CrossRef
Zurück zum Zitat Zhao Z, Lei W, Zhang X, Wang B, Jiang H (2010) ZnO-based amperometric enzyme biosensors. Sensors 10:1216–1231CrossRef Zhao Z, Lei W, Zhang X, Wang B, Jiang H (2010) ZnO-based amperometric enzyme biosensors. Sensors 10:1216–1231CrossRef
Zurück zum Zitat Zhao C, Zhang H, Zheng J (2017) A non-enzymatic electrochemical hydrogen peroxide sensor based on Ag decorated boehmite nanotubes/reduced graphene oxide nanocomposites. J Electroanal Chem 784:55–61CrossRef Zhao C, Zhang H, Zheng J (2017) A non-enzymatic electrochemical hydrogen peroxide sensor based on Ag decorated boehmite nanotubes/reduced graphene oxide nanocomposites. J Electroanal Chem 784:55–61CrossRef
Zurück zum Zitat Zhu L, Xu LL, Tan L, Tan H, Yang SF, Yao SZ (2013) Direct electrochemistry of cholesterol oxidase immobilized on gold nanoparticles-decorated multiwalled carbon nanotubes and cholesterol sensing. Talanta 106:192–199CrossRef Zhu L, Xu LL, Tan L, Tan H, Yang SF, Yao SZ (2013) Direct electrochemistry of cholesterol oxidase immobilized on gold nanoparticles-decorated multiwalled carbon nanotubes and cholesterol sensing. Talanta 106:192–199CrossRef
Zurück zum Zitat Zou J, Chen XQ, Zhao GQ, Jiang XY, Jiao FP, Yu JG (2019a) A novel electrochemical chiral interface based on the synergistic effect of polysaccharides for the recognition of tyrosine enantiomers. Talanta 195:628–637CrossRef Zou J, Chen XQ, Zhao GQ, Jiang XY, Jiao FP, Yu JG (2019a) A novel electrochemical chiral interface based on the synergistic effect of polysaccharides for the recognition of tyrosine enantiomers. Talanta 195:628–637CrossRef
Zurück zum Zitat Zou J, Zhao GQ, Teng J, Liu Q, Jiang XY, Jiao FP, Yu JG (2019b) Highly sensitive detection of bisphenol A in real water samples based on in-situ assembled graphene nanoplatelets and gold nanoparticles composite. Microchem J 145:693–702CrossRef Zou J, Zhao GQ, Teng J, Liu Q, Jiang XY, Jiao FP, Yu JG (2019b) Highly sensitive detection of bisphenol A in real water samples based on in-situ assembled graphene nanoplatelets and gold nanoparticles composite. Microchem J 145:693–702CrossRef
Metadaten
Titel
Amperometric cholesterol biosensor based on reduction graphene oxide-chitosan-ferrocene/platinum nanoparticles modified screen-printed electrode
verfasst von
Guiyin Li
Junxiang Zeng
Le Zhao
Zhihong Wang
Chenyang Dong
Jintao Liang
Zhide Zhou
Yong Huang
Publikationsdatum
01.07.2019
Verlag
Springer Netherlands
Erschienen in
Journal of Nanoparticle Research / Ausgabe 7/2019
Print ISSN: 1388-0764
Elektronische ISSN: 1572-896X
DOI
https://doi.org/10.1007/s11051-019-4602-6

Weitere Artikel der Ausgabe 7/2019

Journal of Nanoparticle Research 7/2019 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.