Abstract

The particulate matters (PM10 and PM2.5) inside urban subway stations greatly influence indoor air quality and passenger comfort. This study aims to analyze and interpret the concentrations of PM10 and PM2.5, measured in several subway stations from October 9th to 22nd, 2016 in Beijing, China. The overall methodology was based on the Statistical Package for Social Science (SPSS) software while General linear model (GLM) and correlation analysis were further applied to examine the sensitivities of different variables to the particle concentrations. The data analysis showed the average overall mass ratio of PM concentrations inside subway station is about 68.7%, much lower than outdoor condition (79.6%). In the areas of the station hall and platform, the real-time PM10 and PM2.5 concentrations varied periodically. In working and operation offices, all rooms had much higher PM concentrations than the outdoor environment when its pollution level was level 3, in which the facility room reached the highest level, while the closed meeting room had the lowest. Correlation analysis results indicated that PM10 and PM2.5 concentrations were mutually correlated (average R2 = 0.854), and a strong linear correlation (R2 = 0.897) of the subway-station PM concentrations to the outdoor PM conditions, regardless of the outdoor atmospheric PM concentrations pollution level was. Nevertheless, the impact of passenger number and temperature and humidity on the station PM concentrations was less, when compared to the outdoor environment. This chapter is expected to provide useful information for further research and design of effective prevention measures on PM in local subway stations, towards a more sustainable and healthier built environment in the city underground.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Cheng YH, Yan JW (2011) Comparisons of particulate matter, CO, and CO2 levels in underground and ground-level stations in the Taipei mass rapid transit system. Atmos Environ 45(28):4882–4891CrossRef Cheng YH, Yan JW (2011) Comparisons of particulate matter, CO, and CO2 levels in underground and ground-level stations in the Taipei mass rapid transit system. Atmos Environ 45(28):4882–4891CrossRef
Zurück zum Zitat Cheng YH, Liu ZS, Yan JW (2012) Comparisons of PM10, PM2.5, particle number, and CO2 levels inside metro trains traveling in underground tunnels and on elevated tracks. Aerosol Air Qual Res 12(5):879–891CrossRef Cheng YH, Liu ZS, Yan JW (2012) Comparisons of PM10, PM2.5, particle number, and CO2 levels inside metro trains traveling in underground tunnels and on elevated tracks. Aerosol Air Qual Res 12(5):879–891CrossRef
Zurück zum Zitat Chillrud SN, Epstein D, Ross JM, Sax SN, Pederson D, Spengler JD, Kinney PL (2004) Elevated airborne exposures of teenagers to manganese, chromium, and iron from steel dust and New York City’s subway system. Environ Sci Technol 38(3):732–737CrossRef Chillrud SN, Epstein D, Ross JM, Sax SN, Pederson D, Spengler JD, Kinney PL (2004) Elevated airborne exposures of teenagers to manganese, chromium, and iron from steel dust and New York City’s subway system. Environ Sci Technol 38(3):732–737CrossRef
Zurück zum Zitat Chillrud SN, Grass D, Ross JM, Coulibaly D, Slavkovich V, Epstein D, Sax SN, Pederson D, Johnson D, Spengler JD, Kinney PL, Simpson HJ, Brandt-Rauf P (2005) Steel dust in the New York City subway system as a source of manganese, chromium, and iron exposures for transit workers. J Urban Health-Bull NY Acad Med 82(1):33–42CrossRef Chillrud SN, Grass D, Ross JM, Coulibaly D, Slavkovich V, Epstein D, Sax SN, Pederson D, Johnson D, Spengler JD, Kinney PL, Simpson HJ, Brandt-Rauf P (2005) Steel dust in the New York City subway system as a source of manganese, chromium, and iron exposures for transit workers. J Urban Health-Bull NY Acad Med 82(1):33–42CrossRef
Zurück zum Zitat Gomez-Perales JE, Covile RN, Nieuwenhuijsen MJ, Fernandez-Brem A, Gutierrez-Avedoy VJ, Paramo-Figueroa VH (2004) Commuters’ exposure to PM2.5, CO, and benzene in public transport in the metropolitan area of Mexico City. Atmos Environ 38:1219–1229CrossRef Gomez-Perales JE, Covile RN, Nieuwenhuijsen MJ, Fernandez-Brem A, Gutierrez-Avedoy VJ, Paramo-Figueroa VH (2004) Commuters’ exposure to PM2.5, CO, and benzene in public transport in the metropolitan area of Mexico City. Atmos Environ 38:1219–1229CrossRef
Zurück zum Zitat Guo L, Hu YJ, Hu QQ, Lin J, Li CL, Chen JM, Li LN, Fu HB (2014) Characteristics and chemical compositions of particulate matter collected at the selected metro stations of Shanghai, China. Sci Total Environ 496:443–452CrossRef Guo L, Hu YJ, Hu QQ, Lin J, Li CL, Chen JM, Li LN, Fu HB (2014) Characteristics and chemical compositions of particulate matter collected at the selected metro stations of Shanghai, China. Sci Total Environ 496:443–452CrossRef
Zurück zum Zitat Harrison RM, Deacon AR, Jones MR (1997) Sources and processes affecting concentration of PM2.5 and PM10 particulate matter in Birmingham (U.K.). Atmos Environ 31(24):4103–4117CrossRef Harrison RM, Deacon AR, Jones MR (1997) Sources and processes affecting concentration of PM2.5 and PM10 particulate matter in Birmingham (U.K.). Atmos Environ 31(24):4103–4117CrossRef
Zurück zum Zitat Hosein KM, Mahdi CYJ, Gholam HS (2014) Concentration and characterization of airborne particles in Tehran’s subway system. Environ Sci Pollut Res 21:7319–7328CrossRef Hosein KM, Mahdi CYJ, Gholam HS (2014) Concentration and characterization of airborne particles in Tehran’s subway system. Environ Sci Pollut Res 21:7319–7328CrossRef
Zurück zum Zitat Huang J, Deng FR, Wu ShW, Guo XB (2012) Comparisons of personal exposure to PM2.5 and CO by different commuting modes in Beijing Chinag. Sci Total Environ 425:52–59CrossRef Huang J, Deng FR, Wu ShW, Guo XB (2012) Comparisons of personal exposure to PM2.5 and CO by different commuting modes in Beijing Chinag. Sci Total Environ 425:52–59CrossRef
Zurück zum Zitat Kam W, Cheung K, Daher N, Sioutas C (2011a) Particulate matter (PM) concentrations in underground and ground-level rail systems of the Los Angeles metro. Atmos Environ 45(8):1506–1516CrossRef Kam W, Cheung K, Daher N, Sioutas C (2011a) Particulate matter (PM) concentrations in underground and ground-level rail systems of the Los Angeles metro. Atmos Environ 45(8):1506–1516CrossRef
Zurück zum Zitat Kam W, Ning Z, Shafer MM, Schauer JJ, Sioutas C (2011b) Chemical characterization and redox potential of coarse and fine particulate matter (PM) in underground and ground-level rail systems of the Los Angeles metro. Environ Sci Technol 45(16):6769–6776CrossRef Kam W, Ning Z, Shafer MM, Schauer JJ, Sioutas C (2011b) Chemical characterization and redox potential of coarse and fine particulate matter (PM) in underground and ground-level rail systems of the Los Angeles metro. Environ Sci Technol 45(16):6769–6776CrossRef
Zurück zum Zitat Kamani H, Hoseini M, Seyedsalehi M, Mahdavi Y, Jaafari J, Safari G (2014) Concentration and characterization of airborne particles in Tehran’s subway system. Environ Sci Pollut Res 21(12):7319–7328CrossRef Kamani H, Hoseini M, Seyedsalehi M, Mahdavi Y, Jaafari J, Safari G (2014) Concentration and characterization of airborne particles in Tehran’s subway system. Environ Sci Pollut Res 21(12):7319–7328CrossRef
Zurück zum Zitat Karlsson L, Nilsson L, Moller L (2005) Subway particles are more genotoxic than street particles and induce oxidative stress in cultured human lung cells. Chem Res Toxicol 18:19–24CrossRef Karlsson L, Nilsson L, Moller L (2005) Subway particles are more genotoxic than street particles and induce oxidative stress in cultured human lung cells. Chem Res Toxicol 18:19–24CrossRef
Zurück zum Zitat Karlsson L, Ljungman AG, Lindbom J, Moller L (2006) Comparison of genotoxic and inflammatory effects of particles generated by wood combustion, a road simulator and collected from street and subway. Toxicol Lett 165(3):203–211CrossRef Karlsson L, Ljungman AG, Lindbom J, Moller L (2006) Comparison of genotoxic and inflammatory effects of particles generated by wood combustion, a road simulator and collected from street and subway. Toxicol Lett 165(3):203–211CrossRef
Zurück zum Zitat Midander K, Elihn K, Wallen A, Belova L, Karlsson AKB, Wallinder IO (2012) Characterisation of nano- and micron-sized airborne and collected subway particles, a multi-analytical approach. Sci Total Environ 427:390–400CrossRef Midander K, Elihn K, Wallen A, Belova L, Karlsson AKB, Wallinder IO (2012) Characterisation of nano- and micron-sized airborne and collected subway particles, a multi-analytical approach. Sci Total Environ 427:390–400CrossRef
Zurück zum Zitat Moreno T, Perez N, Reche C, Martins V, de Miguel E, Capdevila M, Centelles S, Minguillon MC, Amato F, Alastuey A, Querol X, Gibbons W (2014) Subway platform air quality: assessing the influences of tunnel ventilation, train piston effect and station design. Atmos Environ 92:461–468CrossRef Moreno T, Perez N, Reche C, Martins V, de Miguel E, Capdevila M, Centelles S, Minguillon MC, Amato F, Alastuey A, Querol X, Gibbons W (2014) Subway platform air quality: assessing the influences of tunnel ventilation, train piston effect and station design. Atmos Environ 92:461–468CrossRef
Metadaten
Titel
Analysis and Interpretation of the Particulate Matter Concentrations at the Subway Stations by General Linear Model (GLM) and Correlation Analysis
verfasst von
Xinru Wang
Song Pan
Xingxing Zhang
Li Chang
Yiqiao Liu
Copyright-Jahr
2021
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-16-2778-1_13