Skip to main content
Erschienen in:
Buchtitelbild

2022 | OriginalPaper | Buchkapitel

Analysis of the Acoustic Power Emitted by a Physiotherapeutic Ultrasound Equipment Used at the Brazilian Air Force Academy

verfasst von : J. G. S. N. Cavalcanti, W. C. A. Pereira, J. F. S. Costa-Júnior

Erschienen in: XXVII Brazilian Congress on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Therapeutic ultrasound (TUS) is one of the most widely used methods for treating musculoskeletal injuries, in view of the benefits that this treatment provides: it speeds up the tissue repair process, for example. However, when TUS devices operate outside the range recommended by International Standard IEC 61689:2013, they can cause ineffective treatments or even aggravate the injury. This study aims to analyze the acoustic power emitted by a TUS device from Esquadrão de Saúde de Pirassununga and observe whether the values obtained are within the range established by the IEC 61689:2013. An acoustic radiation force balance was used to measure the power emitted by the equipment. The results showed that on all test days there was a divergence between the nominal and the emitted powers, which exceeded the value recommended by the IEC.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Prentice WE (2011) Therapeutic modalities in rehabilitation. McGraw-Hill, New York Prentice WE (2011) Therapeutic modalities in rehabilitation. McGraw-Hill, New York
2.
Zurück zum Zitat Kumar V, Abbas AK, Aster JC (2013) Patologia Básica. Elsevier, Rio de Janeiro Kumar V, Abbas AK, Aster JC (2013) Patologia Básica. Elsevier, Rio de Janeiro
3.
Zurück zum Zitat Habash RWY, Bansal R, Krewski D et al (2006) Thermal therapy, part 1: an introduction to thermal therapy. Crit Rev Biomed Eng 34:459–489CrossRef Habash RWY, Bansal R, Krewski D et al (2006) Thermal therapy, part 1: an introduction to thermal therapy. Crit Rev Biomed Eng 34:459–489CrossRef
4.
Zurück zum Zitat Stewart HF, Harris GR, Herman BA et al (1974) Survey of the use and performance of ultrasonic therapy equipment in Pinellas County. Phys Ther 54:707–715CrossRef Stewart HF, Harris GR, Herman BA et al (1974) Survey of the use and performance of ultrasonic therapy equipment in Pinellas County. Phys Ther 54:707–715CrossRef
5.
Zurück zum Zitat Lima LS, Costa Júnior JFS, Costa RM et al (2012) Exatidão da potência acústica de equipamentos comerciais de ultrassom fisioterapêutico. CBEB 2012. XXIII Congresso Brasileiro De Engenharia Biomédica, Porto De Galinhas, Brazil 2012:2443–2447 Lima LS, Costa Júnior JFS, Costa RM et al (2012) Exatidão da potência acústica de equipamentos comerciais de ultrassom fisioterapêutico. CBEB 2012. XXIII Congresso Brasileiro De Engenharia Biomédica, Porto De Galinhas, Brazil 2012:2443–2447
6.
Zurück zum Zitat Shaw A, Hodnett M (2008) Calibration and measurement issues for therapeutic ultrasound. Ultrasonics 48:234–252CrossRef Shaw A, Hodnett M (2008) Calibration and measurement issues for therapeutic ultrasound. Ultrasonics 48:234–252CrossRef
7.
Zurück zum Zitat Martins ARA, AAS, Omena TP et al (2016) Aferição da intensidade de dois aparelhos de ultrassom fisioterapêutico pós-manutenção. CBEB 2016, XXV Congresso Brasileiro de Engenharia Biomédica, Foz do Iguaçu, Brazil, pp 1989–1992 Martins ARA, AAS, Omena TP et al (2016) Aferição da intensidade de dois aparelhos de ultrassom fisioterapêutico pós-manutenção. CBEB 2016, XXV Congresso Brasileiro de Engenharia Biomédica, Foz do Iguaçu, Brazil, pp 1989–1992
8.
Zurück zum Zitat Ferrari CB, Andrade MAB, Adamowski JC et al (2010) Evaluation of therapeutic ultrasound equipments performance. Ultrasonics 50:704–709CrossRef Ferrari CB, Andrade MAB, Adamowski JC et al (2010) Evaluation of therapeutic ultrasound equipments performance. Ultrasonics 50:704–709CrossRef
9.
Zurück zum Zitat Johns LD, Straub SJ, Howard SM (2007) Variability in effective radiating area and output power of new ultrasound transducers at 3 MHz. J Athl Train 42:22–28 Johns LD, Straub SJ, Howard SM (2007) Variability in effective radiating area and output power of new ultrasound transducers at 3 MHz. J Athl Train 42:22–28
10.
Zurück zum Zitat IEC 61689:2013. Ultrasonics—Physiotherapy systems—Field specifications and methods of measurement in the frequency range 0.5 MHz to 5 MHz, 3rd ed. 2013. IEC 61689:2013. Ultrasonics—Physiotherapy systems—Field specifications and methods of measurement in the frequency range 0.5 MHz to 5 MHz, 3rd ed. 2013.
11.
Zurück zum Zitat International vocabulary of metrology: basic and general concepts and associated terms, 3rd. ed. JCGM 200:2012 (2012) International vocabulary of metrology: basic and general concepts and associated terms, 3rd. ed. JCGM 200:2012 (2012)
12.
Zurück zum Zitat Razali NM, Wah YB (2011) Power comparisons of Shapiro-Wilk, Kolmogorov-Smirnov, Lilliefors and Anderson-Darling tests. J Stat Model 2:21–33 Razali NM, Wah YB (2011) Power comparisons of Shapiro-Wilk, Kolmogorov-Smirnov, Lilliefors and Anderson-Darling tests. J Stat Model 2:21–33
13.
Zurück zum Zitat Riboldi J, Barbian MH, Kolowski ABS et al (2014) Accuracy and power of parametric and non-parametric homoscedasticity tests assessed for simulation. Rev Bras Biom 32:334–344 Riboldi J, Barbian MH, Kolowski ABS et al (2014) Accuracy and power of parametric and non-parametric homoscedasticity tests assessed for simulation. Rev Bras Biom 32:334–344
14.
Zurück zum Zitat Pye SD, Milford C (1992) The performance of ultrasound physiotherapy machines in Lothian Region. Ultrasound Med Biol 20:347–359CrossRef Pye SD, Milford C (1992) The performance of ultrasound physiotherapy machines in Lothian Region. Ultrasound Med Biol 20:347–359CrossRef
15.
Zurück zum Zitat Guirro R, Santos SCB (2002) Evaluation of the acoustic intensity of new ultrasound therapy. Ultrasonics 39:553–557CrossRef Guirro R, Santos SCB (2002) Evaluation of the acoustic intensity of new ultrasound therapy. Ultrasonics 39:553–557CrossRef
Metadaten
Titel
Analysis of the Acoustic Power Emitted by a Physiotherapeutic Ultrasound Equipment Used at the Brazilian Air Force Academy
verfasst von
J. G. S. N. Cavalcanti
W. C. A. Pereira
J. F. S. Costa-Júnior
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_1

Neuer Inhalt