Skip to main content
Erschienen in: Energy Efficiency 4/2018

24.01.2018 | Original Article

Assessing the energy saving potential of anidolic system in the tropics

verfasst von: Floriberta Binarti, Prasasto Satwiko

Erschienen in: Energy Efficiency | Ausgabe 4/2018

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Employing the edge-ray principle, the anidolic system (AS) has been proven as a promising daylighting solution for various climates. However, studies on the thermal performance of an AS are still rare. Because of the dominant contribution of the space-cooling load to building energy consumption at the operational stage in hot climates, knowledge of the impact of AS application on the space-cooling load is important. This study assessed the energy-saving potential of AS in the tropics by measuring the daylight level and distribution, as well as the solar heat gain, based on Radiance and EnergyPlus simulations using weather files of two locations in the tropics—Yogyakarta and Singapore. Monitoring data of a full-scale, unoccupied test building was acquired to validate the Radiance simulations and EnergyPlus models. A comparison between the energy-saving potential for lighting and cooling of AS and conventional aperture models showed that the application of AS in the tropics benefits the daylighting performance (DF ≥ 3% and horizontal distribution 51–70%), but still produces higher solar heat gains (44–437% higher than those of clerestory only). Narrow anidolic collectors with medium angular spread (45°–52°) and maximum clerestory height equipped with internal shelves can be applied to produce lower solar heat gain or indoor air temperature (2%) with sufficient daylight levels (≥ 2%) and an increased in horizontal illuminance distribution (> 57%).

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Aizlewood, M. E. (1993). Innovative daylighting systems: an experimental evaluation. Lighting Research and Technology, 25(4), 141–152.CrossRef Aizlewood, M. E. (1993). Innovative daylighting systems: an experimental evaluation. Lighting Research and Technology, 25(4), 141–152.CrossRef
Zurück zum Zitat Al-Obaidi, K. M., Ismail, M., & Abdul Rahman, A. M. (2014). A study of the impacts of environmental loads that penetrate a passive skylight roofing system in Malaysian buildings. Frontiers Architectural Research, 3, 178–191.CrossRef Al-Obaidi, K. M., Ismail, M., & Abdul Rahman, A. M. (2014). A study of the impacts of environmental loads that penetrate a passive skylight roofing system in Malaysian buildings. Frontiers Architectural Research, 3, 178–191.CrossRef
Zurück zum Zitat ASHRAE. (2013). ASHRAE Handbook: Fundamental. Atlanta: ASHRAE. ASHRAE. (2013). ASHRAE Handbook: Fundamental. Atlanta: ASHRAE.
Zurück zum Zitat Binarti, F. (2009). Energy-Efficient Window for Classroom in Warm Tropical Area. 11th International IBPSA Conference, Glasgow, Scotland, UK, July 27–30, 2009, pp.1655–1662. Binarti, F. (2009). Energy-Efficient Window for Classroom in Warm Tropical Area. 11th International IBPSA Conference, Glasgow, Scotland, UK, July 27–30, 2009, pp.1655–1662.
Zurück zum Zitat Chirarattananon, S., & Chaiwiwatworakul, P. (2007). Distribution of sky luminance and radiance of North Bangkok under standard distributions. Renewable Energy, 26, 1328–1345.CrossRef Chirarattananon, S., & Chaiwiwatworakul, P. (2007). Distribution of sky luminance and radiance of North Bangkok under standard distributions. Renewable Energy, 26, 1328–1345.CrossRef
Zurück zum Zitat Crawley, D.B., Lawrie, L.K., Winkelmann, F.C., Buhl, W.F., Pedersen, C.O., Strand, R.K., Liesen, R.J., Fisher, D.E., Witte, M.J., Henninger, R.H., Glazer, J., & Shirey, D. (2013). EnergyPlus v.8.1. Atlanta, Georgia. Crawley, D.B., Lawrie, L.K., Winkelmann, F.C., Buhl, W.F., Pedersen, C.O., Strand, R.K., Liesen, R.J., Fisher, D.E., Witte, M.J., Henninger, R.H., Glazer, J., & Shirey, D. (2013). EnergyPlus v.8.1. Atlanta, Georgia.
Zurück zum Zitat Ellis, P. G. (2003). Development and validation of the unvented Trombe Wall model in EnergyPlus. USA: Master Thesis. University of Illinois at Urbana-Champaign. Ellis, P. G. (2003). Development and validation of the unvented Trombe Wall model in EnergyPlus. USA: Master Thesis. University of Illinois at Urbana-Champaign.
Zurück zum Zitat Erell, E., Kaftan, E., & Garb, Y. (2014). Daylighting for Visual Comfort and Energy Conservation in Offices in Sunny Regions. Proc. of 30th International PLEA Conference - Sustainable Habitat for Developing Societies, Ahmedabad, India, 16–18 December 2014. Erell, E., Kaftan, E., & Garb, Y. (2014). Daylighting for Visual Comfort and Energy Conservation in Offices in Sunny Regions. Proc. of 30th International PLEA Conference - Sustainable Habitat for Developing Societies, Ahmedabad, India, 16–18 December 2014.
Zurück zum Zitat Goia, F. (2016). Search for the optimal window-to-wall ratio in office buildings in different European climates and the implication on total energy saving potential. Applied Energy, 132, 467–492. Goia, F. (2016). Search for the optimal window-to-wall ratio in office buildings in different European climates and the implication on total energy saving potential. Applied Energy, 132, 467–492.
Zurück zum Zitat Hachem, C., Athienitis, A., & Fazio, P. (2011). Parametric investigation form effects on solar potential of housing units. Solar Energy, 85, 1864–1877.CrossRef Hachem, C., Athienitis, A., & Fazio, P. (2011). Parametric investigation form effects on solar potential of housing units. Solar Energy, 85, 1864–1877.CrossRef
Zurück zum Zitat Huang, Y., Niu, J.-L., & Chung, T.-M. (2014). Comprehensive analysis on thermal and daylighting performance of glazing and shading designs on office building envelope in cooling-dominant climates. Applied Energy, 134, 215–228.CrossRef Huang, Y., Niu, J.-L., & Chung, T.-M. (2014). Comprehensive analysis on thermal and daylighting performance of glazing and shading designs on office building envelope in cooling-dominant climates. Applied Energy, 134, 215–228.CrossRef
Zurück zum Zitat Kleindienst, S.A. (2006). Improving the daylighting conditions of existing buildings: the benefits and limitations of integrating anidolic daylighting systems using the American classroom as a model. Master thesis, Massachusetts Institute of Technology, USA, 2006. Kleindienst, S.A. (2006). Improving the daylighting conditions of existing buildings: the benefits and limitations of integrating anidolic daylighting systems using the American classroom as a model. Master thesis, Massachusetts Institute of Technology, USA, 2006.
Zurück zum Zitat Leadership in Energy and Environmental Design (LEED). (2009). Reference Guide for Green Building Design and Construction, for the Design, Construction and Major Renovations of Commercial and Institutional Building Including Core and Shell K-12 School Projects, ed.www.usgbc.org. Accessed 6 November 2010. Leadership in Energy and Environmental Design (LEED). (2009). Reference Guide for Green Building Design and Construction, for the Design, Construction and Major Renovations of Commercial and Institutional Building Including Core and Shell K-12 School Projects, ed.www.​usgbc.​org. Accessed 6 November 2010.
Zurück zum Zitat Linhart, F., Wittkopf, S. K., & Scartezzini, J.-L. (2010). Performance of anidolic daylighting systems in tropical climates, parametric studies for identification of main influencing factors. Solar Energy, 84, 1085–1094.CrossRef Linhart, F., Wittkopf, S. K., & Scartezzini, J.-L. (2010). Performance of anidolic daylighting systems in tropical climates, parametric studies for identification of main influencing factors. Solar Energy, 84, 1085–1094.CrossRef
Zurück zum Zitat Loutsenhiser, P. G., Manz, H., Felsmann, C., Strachan, P. A., Frank, T., & Maxwell, G. M. (2007). Empirical validation of models to compute solar irradiance on inclined surfaces for building energy simulation. Solar Energy, 81, 254–267.CrossRef Loutsenhiser, P. G., Manz, H., Felsmann, C., Strachan, P. A., Frank, T., & Maxwell, G. M. (2007). Empirical validation of models to compute solar irradiance on inclined surfaces for building energy simulation. Solar Energy, 81, 254–267.CrossRef
Zurück zum Zitat Loutsenhiser, P. G., Manz, H., Carl, S., Simmler, H., & Maxwell, G. M. (2008). Empirical validations of solar gain models for a glazing unit with exterior and interior blind assemblies. Energy and Buildings, 40, 330–340.CrossRef Loutsenhiser, P. G., Manz, H., Carl, S., Simmler, H., & Maxwell, G. M. (2008). Empirical validations of solar gain models for a glazing unit with exterior and interior blind assemblies. Energy and Buildings, 40, 330–340.CrossRef
Zurück zum Zitat Marsch, A.(2005). Ecotect Software v.5.5. Square One, Cardiff. Marsch, A.(2005). Ecotect Software v.5.5. Square One, Cardiff.
Zurück zum Zitat Michael, A., & Heracleous, C. (2016). Assessment of natural lighting performance and visual comfort of educational architecture in southern Europe: the case of typical educational school premises in Cyprus. Energy and Buildings, 140, 443–457.CrossRef Michael, A., & Heracleous, C. (2016). Assessment of natural lighting performance and visual comfort of educational architecture in southern Europe: the case of typical educational school premises in Cyprus. Energy and Buildings, 140, 443–457.CrossRef
Zurück zum Zitat Mirsadeghi, M., Costola, D., Blocken, B., & Hensen, J. L. M. (2013). Review of external convective heat transfer coefficient models in building energy simulation programs: implementation and uncertainty. Applied Thermal Engineering, 56(1–2), 134–151.CrossRef Mirsadeghi, M., Costola, D., Blocken, B., & Hensen, J. L. M. (2013). Review of external convective heat transfer coefficient models in building energy simulation programs: implementation and uncertainty. Applied Thermal Engineering, 56(1–2), 134–151.CrossRef
Zurück zum Zitat Praditwattanakit, R., Chaiwiwatworakul, P., & Chirarattananon, S. (2013). Anidolic concentrator to enhance the daylight use in tropical buildings. In: International Conference on Alternative Energy in Developing Countries and Emerging Economies. Bangkok, Thailand, 30–31 May 2013, ftp://202.28.64.61/04.April2013/Dowload/print/ 139_Rut%20Praditwattanakit.docx. Accessed 7 August 2014. Praditwattanakit, R., Chaiwiwatworakul, P., & Chirarattananon, S. (2013). Anidolic concentrator to enhance the daylight use in tropical buildings. In: International Conference on Alternative Energy in Developing Countries and Emerging Economies. Bangkok, Thailand, 30–31 May 2013, ftp://​202.​28.​64.​61/​04.​April2013/​Dowload/​print/​ 139_Rut%20Praditwattanakit.docx. Accessed 7 August 2014.
Zurück zum Zitat Prasetyo, S. S., & Kusumarini, Y. (2016). Studi Efisiensi dan Konservasi Energi pada Interior Gedung P Universitas Kristen Petra. Jurnal INTRA, 4(1), 36–45. Prasetyo, S. S., & Kusumarini, Y. (2016). Studi Efisiensi dan Konservasi Energi pada Interior Gedung P Universitas Kristen Petra. Jurnal INTRA, 4(1), 36–45.
Zurück zum Zitat Pritchard, D.C. (ed). (1986). Interior lighting design, 6th ed., London: The Lighting Industry Federation Ltd. And The Electricity Council. Pritchard, D.C. (ed). (1986). Interior lighting design, 6th ed., London: The Lighting Industry Federation Ltd. And The Electricity Council.
Zurück zum Zitat Rahim, R. & Mulyadi, R. (2004). Preliminary study of horizontal illuminance in Indonesia. In: 5th SENVAR, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia, 10–12 December 2004, pp.1–10. Rahim, R. & Mulyadi, R. (2004). Preliminary study of horizontal illuminance in Indonesia. In: 5th SENVAR, Universiti Teknologi Malaysia, Skudai, Johor, Malaysia, 10–12 December 2004, pp.1–10.
Zurück zum Zitat Reinhart, C. F., & Andersen, M. (2006). Development and validation of a radiance model for a translucent panel. Energy and Buildings, 38(7), 890–904.CrossRef Reinhart, C. F., & Andersen, M. (2006). Development and validation of a radiance model for a translucent panel. Energy and Buildings, 38(7), 890–904.CrossRef
Zurück zum Zitat Roshan, M., Kandar, M. Z. B., Nikpur, M., Mohammadi, M. P., & Ghasemi, M. (2013). Investigating the performance of anidolic daylighting system with respect to building orientation in tropical area. IRACST-ESTIJ, 3, 74–79. Roshan, M., Kandar, M. Z. B., Nikpur, M., Mohammadi, M. P., & Ghasemi, M. (2013). Investigating the performance of anidolic daylighting system with respect to building orientation in tropical area. IRACST-ESTIJ, 3, 74–79.
Zurück zum Zitat Scartezzini, J.-L., & Courret, G. (2002). Anidolic daylighting systems. Solar Energy, 73, 123–135.CrossRef Scartezzini, J.-L., & Courret, G. (2002). Anidolic daylighting systems. Solar Energy, 73, 123–135.CrossRef
Zurück zum Zitat Singh, R., Lazarus, I. J., & Kishore, V. V. N. (2015). Effect of internal woven roller shade and glazing on the energy and daylighting performances of an office building in the cold climate of Shillong. Applied Energy, 159, 317–333.CrossRef Singh, R., Lazarus, I. J., & Kishore, V. V. N. (2015). Effect of internal woven roller shade and glazing on the energy and daylighting performances of an office building in the cold climate of Shillong. Applied Energy, 159, 317–333.CrossRef
Zurück zum Zitat Standar Nasional Indonesia (SNI). (2011). SNI-6390: Konservasi energi sistem tata udara bangunan gedung. Jakarta: Badan Standardisasi Nasional. Standar Nasional Indonesia (SNI). (2011). SNI-6390: Konservasi energi sistem tata udara bangunan gedung. Jakarta: Badan Standardisasi Nasional.
Zurück zum Zitat Sunaga, N., Soebarto, V., Hyde, R., Ribeiro, M. A. Junghans, L., Binarti, F., & Calderaro, V. (2008). Chapter 9: design, elements, and strategies. In R. Hyde (Ed.), Bioclimatic housing: innovative designs for warm climates. London: Earthscan. Sunaga, N., Soebarto, V., Hyde, R., Ribeiro, M. A. Junghans, L., Binarti, F., & Calderaro, V. (2008). Chapter 9: design, elements, and strategies. In R. Hyde (Ed.), Bioclimatic housing: innovative designs for warm climates. London: Earthscan.
Zurück zum Zitat Tindale, A. & Potter, S. (2014). DesignBuilder v.4.0. Gloucestershire. Tindale, A. & Potter, S. (2014). DesignBuilder v.4.0. Gloucestershire.
Zurück zum Zitat University of Illinois and Lawrence Berkeley National Laboratory. (2015). EnergyPlus Documentation: Engineering Reference. University of Illinois and Lawrence Berkeley National Laboratory. (2015). EnergyPlus Documentation: Engineering Reference.
Zurück zum Zitat Ward, G. (2002). Desktop radiance software. California: Lawrence Berkeley Laboratory. Ward, G. (2002). Desktop radiance software. California: Lawrence Berkeley Laboratory.
Zurück zum Zitat Wittkopf, S. K. (2006). Daylight performance of anidolic ceiling under different sky conditions. Solar Energy, 81, 151–161.CrossRef Wittkopf, S. K. (2006). Daylight performance of anidolic ceiling under different sky conditions. Solar Energy, 81, 151–161.CrossRef
Zurück zum Zitat Wittkopf, S. K., Grobe, L. O., Compagnon, R., Kampf, J., Linhart, F., & Scartezzini, J.-L. (2010). Ray tracing study for non-imaging daylight collectors. Solar Energy, 84, 986–996.CrossRef Wittkopf, S. K., Grobe, L. O., Compagnon, R., Kampf, J., Linhart, F., & Scartezzini, J.-L. (2010). Ray tracing study for non-imaging daylight collectors. Solar Energy, 84, 986–996.CrossRef
Zurück zum Zitat Zhu, D., Hong, T., Yan, D., & Wang, C. (2012). Comparison of building energy modeling programs: building loads. Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) – 6034E. LA. Zhu, D., Hong, T., Yan, D., & Wang, C. (2012). Comparison of building energy modeling programs: building loads. Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) – 6034E. LA.
Metadaten
Titel
Assessing the energy saving potential of anidolic system in the tropics
verfasst von
Floriberta Binarti
Prasasto Satwiko
Publikationsdatum
24.01.2018
Verlag
Springer Netherlands
Erschienen in
Energy Efficiency / Ausgabe 4/2018
Print ISSN: 1570-646X
Elektronische ISSN: 1570-6478
DOI
https://doi.org/10.1007/s12053-017-9603-7

Weitere Artikel der Ausgabe 4/2018

Energy Efficiency 4/2018 Zur Ausgabe