Skip to main content

2018 | OriginalPaper | Buchkapitel

Derived Non-contact Continuous Recording of Blood Pressure Pulse Waveform by Means of Vibrocardiography

verfasst von : Luigi Casacanditella, Gloria Cosoli, Sara Casaccia, Lorenzo Scalise, Enrico Primo Tomasini

Erschienen in: Sensors

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Blood Pressure (BP) is considered a significant indicator of cardiac risk. By providing information about the hemodynamic load on the heart, BP detected in a central site may have added value with respect to the more familiar peripheral arterial pressure (i.e. measured on the brachial artery). Laser Doppler Vibrometry (LDV) has been demonstrated to be a reliable non-contact technique to measure the cardiovascular signals and parameters. LDV has a high sensitivity of acquisition and it is able to measure the skin vibrations related to cardiac activity when the laser beam is pointed in correspondence of the carotid artery. The obtainable vibrational signal (i.e. a velocity signal), VibroCardioGram (VCG), can provide relevant physiological parameters, including Heart Rate (HR) as well as more advanced features encoded in the contour of the pulse waveform. In this work, the authors aim to discuss the possibility of deriving the blood pressure signal from the vibrations of the carotid artery detected by LDV. 6 healthy participants were tested; the VCG was calibrated by means of diastolic and mean arterial pressure values measured by means of an oscillometric cuff. An exponential model was applied to the VCG signal of each participant in order to derive the pressure waveform from the displacement of the investigated vessel. Results show an average difference of around 20% between systolic pressure measured at brachial level (i.e. peripheral pressure value) and systolic pressure derived from VCG signal measured over the carotid artery (i.e. central pressure). This is consistent with the literature describing the physiological increase of Systolic Blood Pressure (SBP) and Pressure Pulse (PP) at increased distances from the heart (because of the presence of reflected waves). Moreover, the average measured displacements of the carotid artery are physiologically reliable (i.e. hundreds of micrometers). LDV seems to have the potential of correctly detecting the pressure waveform without contact. However, a comparison with a reference method is required to validate the proposed measurement technique.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat J. Sharman, M. Stowasser, R. Fassett, T. Marwick, S. Franklin, Central blood pressure measurement may improve risk stratification. J. Hum. Hypertens. 22(12), 838–844 (2008)CrossRef J. Sharman, M. Stowasser, R. Fassett, T. Marwick, S. Franklin, Central blood pressure measurement may improve risk stratification. J. Hum. Hypertens. 22(12), 838–844 (2008)CrossRef
2.
Zurück zum Zitat M.A. Quail, J.A. Steeden, D. Knight, P. Segers, A.M. Taylor, V. Muthurangu, Development and validation of a novel method to derive central aortic systolic pressure from the MR aortic distension curve. J. Magn. Reson. Imaging JMRI 40(5), 1064–1070 (2014)CrossRef M.A. Quail, J.A. Steeden, D. Knight, P. Segers, A.M. Taylor, V. Muthurangu, Development and validation of a novel method to derive central aortic systolic pressure from the MR aortic distension curve. J. Magn. Reson. Imaging JMRI 40(5), 1064–1070 (2014)CrossRef
4.
Zurück zum Zitat J. Vappou, J. Luo, K. Okajima, M. Di Tullio, E.E. Konofagou, Non-invasive measurement of local pulse pressure by pulse wave-based ultrasound manometry (PWUM). Physiol. Meas. 32(10), 1653–1662 (2011)CrossRef J. Vappou, J. Luo, K. Okajima, M. Di Tullio, E.E. Konofagou, Non-invasive measurement of local pulse pressure by pulse wave-based ultrasound manometry (PWUM). Physiol. Meas. 32(10), 1653–1662 (2011)CrossRef
5.
Zurück zum Zitat M. Pinotti, N. Paone, F.A. Santos, E.P. Tomasini, Carotid Artery Pulse Wave Measured by a Laser Vibrometer, vol 3411 (1998), pp. 611–616 M. Pinotti, N. Paone, F.A. Santos, E.P. Tomasini, Carotid Artery Pulse Wave Measured by a Laser Vibrometer, vol 3411 (1998), pp. 611–616
6.
Zurück zum Zitat L. Scalise, N. Bernacchia, I. Ercoli, P. Marchionni, Heart rate measurement in neonatal patients using a webcamera, in 2012 IEEE International Symposium on Medical Measurements and Applications Proceedings (MeMeA), 2012, pp. 1–4 L. Scalise, N. Bernacchia, I. Ercoli, P. Marchionni, Heart rate measurement in neonatal patients using a webcamera, in 2012 IEEE International Symposium on Medical Measurements and Applications Proceedings (MeMeA), 2012, pp. 1–4
7.
Zurück zum Zitat L. Scalise, U. Morbiducci, Non-contact cardiac monitoring from carotid artery using optical vibrocardiography. Med. Eng. Phys. 30(4), 490–497 (2008)CrossRef L. Scalise, U. Morbiducci, Non-contact cardiac monitoring from carotid artery using optical vibrocardiography. Med. Eng. Phys. 30(4), 490–497 (2008)CrossRef
8.
Zurück zum Zitat S. Casaccia, E.J. Sirevaag, E. Richter, J.A. O’Sullivan, L. Scalise, J.W. Rohrbaugh, Decoding carotid pressure waveforms recorded by laser Doppler vibrometry: effects of rebreathing, in AIP Conference Proceedings, vol 1600, 2014, pp. 298–312 S. Casaccia, E.J. Sirevaag, E. Richter, J.A. O’Sullivan, L. Scalise, J.W. Rohrbaugh, Decoding carotid pressure waveforms recorded by laser Doppler vibrometry: effects of rebreathing, in AIP Conference Proceedings, vol 1600, 2014, pp. 298–312
9.
Zurück zum Zitat P.H. Lai, J.A. O’Sullivan, M. Chen, E.J. Sirevaag, A.D. Kaplan, J.W. Rohrbaugh, A robust feature selection method for noncontact biometrics based on Laser Doppler Vibrometry, in Biometrics Symposium, 2008. BSYM ’08, 2008, pp. 65–70 P.H. Lai, J.A. O’Sullivan, M. Chen, E.J. Sirevaag, A.D. Kaplan, J.W. Rohrbaugh, A robust feature selection method for noncontact biometrics based on Laser Doppler Vibrometry, in Biometrics Symposium, 2008. BSYM ’08, 2008, pp. 65–70
10.
Zurück zum Zitat M. Chen, J.A. O’Sullivan, N. Singla, E.J. Sirevaag, S.D. Kristjansson, P.H. Lai, A.D. Kaplan, J.W. Rohrbaugh, Laser Doppler vibrometry measures of physiological function: evaluation of biometric capabilities. IEEE Trans. Inf. Forensics Secur. 5(3), 449–460 (2010)CrossRef M. Chen, J.A. O’Sullivan, N. Singla, E.J. Sirevaag, S.D. Kristjansson, P.H. Lai, A.D. Kaplan, J.W. Rohrbaugh, Laser Doppler vibrometry measures of physiological function: evaluation of biometric capabilities. IEEE Trans. Inf. Forensics Secur. 5(3), 449–460 (2010)CrossRef
11.
Zurück zum Zitat A. Campo, P. Segers, H. Heuten, I. Goovaerts, G. Ennekens, C. Vrints, R. Baets, J. Dirckx, Non-invasive technique for assessment of vascular wall stiffness using laser Doppler vibrometry. Meas. Sci. Technol. 25(6), 65701 (2014) A. Campo, P. Segers, H. Heuten, I. Goovaerts, G. Ennekens, C. Vrints, R. Baets, J. Dirckx, Non-invasive technique for assessment of vascular wall stiffness using laser Doppler vibrometry. Meas. Sci. Technol. 25(6), 65701 (2014)
12.
Zurück zum Zitat G. Cosoli, L. Casacanditella, E.P. Tomasini, L. Scalise, The non-contact measure of the heart rate variability by laser doppler vibrometry: comparison with electrocardiography. Meas. Sci. Tecnol. (in press) G. Cosoli, L. Casacanditella, E.P. Tomasini, L. Scalise, The non-contact measure of the heart rate variability by laser doppler vibrometry: comparison with electrocardiography. Meas. Sci. Tecnol. (in press)
13.
Zurück zum Zitat E.J. Sirevaag, S. Casaccia, E.A. Richter, J.A. O’Sullivan, L. Scalise, J.W. Rohrbaugh, Cardiorespiratory interactions: noncontact assessment using laser Doppler vibrometry. Psychophysiology, p. n/a-n/a, Mar 2016 E.J. Sirevaag, S. Casaccia, E.A. Richter, J.A. O’Sullivan, L. Scalise, J.W. Rohrbaugh, Cardiorespiratory interactions: noncontact assessment using laser Doppler vibrometry. Psychophysiology, p. n/a-n/a, Mar 2016
15.
Zurück zum Zitat S.J. Vermeersch, E.R. Rietzschel, M.L. De Buyzere, D. De Bacquer, G. De Backer, L.M. Van Bortel, T.C. Gillebert, P.R. Verdonck, P. Segers, Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects. Physiol. Meas. 29(11), 1267–1280 (2008)CrossRef S.J. Vermeersch, E.R. Rietzschel, M.L. De Buyzere, D. De Bacquer, G. De Backer, L.M. Van Bortel, T.C. Gillebert, P.R. Verdonck, P. Segers, Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects. Physiol. Meas. 29(11), 1267–1280 (2008)CrossRef
16.
Zurück zum Zitat C.L. Desjardins, L.T. Antonelli, E. Soares, A Remote and Non-contact Method for Obtaining the Blood-Pulse Waveform with a Laser Doppler Vibrometer, vol 6430 (2007), pp. 64301C–64301C–9 C.L. Desjardins, L.T. Antonelli, E. Soares, A Remote and Non-contact Method for Obtaining the Blood-Pulse Waveform with a Laser Doppler Vibrometer, vol 6430 (2007), pp. 64301C–64301C–9
Metadaten
Titel
Derived Non-contact Continuous Recording of Blood Pressure Pulse Waveform by Means of Vibrocardiography
verfasst von
Luigi Casacanditella
Gloria Cosoli
Sara Casaccia
Lorenzo Scalise
Enrico Primo Tomasini
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-319-55077-0_46

Neuer Inhalt