Abstract

Displays are an essential part of user interactions with medical devices. They present users with information to help make healthcare decisions quickly, safely, and effectively. Displays can be designed to accommodate any sensory modality (e.g., vision, hearing, tactile). This chapter examines visual and auditory displays in detail. It also provides introductory information and resources about tactile displays. The chapter begins with an overview of visual display technologies, then discusses use-related factors with each category. Afterward, the chapter explores auditory displays and alarms, as well as design tips to create discoverable, meaningful, and potentially urgent sounds in an auditory display. The chapter concludes with alarm-specific design recommendations and considerations.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Akeroyd, M. A. (2014). An overview of the major phenomena of the localization of sound sources by normal-hearing, hearing-impaired, and aided listeners. Trends in Hearing, 18, 233121651456044.CrossRef Akeroyd, M. A. (2014). An overview of the major phenomena of the localization of sound sources by normal-hearing, hearing-impaired, and aided listeners. Trends in Hearing, 18, 233121651456044.CrossRef
Zurück zum Zitat Alain, C., Du, Y., Bernstein, L. J., Barten, T., & Banai, K. (2018). Listening under difficult conditions: An activation likelihood estimation meta-analysis. Human Brain Mapping, 39(7), 2695–2709.CrossRef Alain, C., Du, Y., Bernstein, L. J., Barten, T., & Banai, K. (2018). Listening under difficult conditions: An activation likelihood estimation meta-analysis. Human Brain Mapping, 39(7), 2695–2709.CrossRef
Zurück zum Zitat Alami, A. (2017). To what extent does the medicalisation of the English language complicate the teaching of medical ESP to Japanese medical students learning English as a foreign language. International Journal of Learning Teaching and Educational Research, 16, 102–110. Alami, A. (2017). To what extent does the medicalisation of the English language complicate the teaching of medical ESP to Japanese medical students learning English as a foreign language. International Journal of Learning Teaching and Educational Research, 16, 102–110.
Zurück zum Zitat ANSI/HFES100. (2007). National standards for human factors engineering of computer workstations. HFES (p. 67). ANSI/HFES100. (2007). National standards for human factors engineering of computer workstations. HFES (p. 67).
Zurück zum Zitat Association for the Advancement of Medical Instrumentation. (2009). ANSI/AAMI HE75–2009: Human factors engineering—Design of medical devices. Arlington, VA: Association for the Advancement of Medical Instrumentation. Association for the Advancement of Medical Instrumentation. (2009). ANSI/AAMI HE75–2009: Human factors engineering—Design of medical devices. Arlington, VA: Association for the Advancement of Medical Instrumentation.
Zurück zum Zitat Association for the Advancement of Medical Instrumentation. (2011). A siren call to action: Priority issues from the medical device alarms summit. Arlington, VA: Association for the Advancement of Medical Instrumentation. Association for the Advancement of Medical Instrumentation. (2011). A siren call to action: Priority issues from the medical device alarms summit. Arlington, VA: Association for the Advancement of Medical Instrumentation.
Zurück zum Zitat Baber, C., Stanton, N. A., & Stockley, A. (1992). Can speech be used for alarm displays in ‘process control type tasks? Behaviour & Information Technology, 11(4), 216–226.CrossRef Baber, C., Stanton, N. A., & Stockley, A. (1992). Can speech be used for alarm displays in ‘process control type tasks? Behaviour & Information Technology, 11(4), 216–226.CrossRef
Zurück zum Zitat Bellettiere, J., Hughes, S. C., Liles, S., Boman-Davis, M., Klepeis, N., Blumberg, E., et al. (2014). Developing and selecting auditory warnings for a real-time behavioral intervention. American Journal of Public Health Research, 2(6), 232.CrossRef Bellettiere, J., Hughes, S. C., Liles, S., Boman-Davis, M., Klepeis, N., Blumberg, E., et al. (2014). Developing and selecting auditory warnings for a real-time behavioral intervention. American Journal of Public Health Research, 2(6), 232.CrossRef
Zurück zum Zitat Blattner, M. M., Sumikawa, D. A., & Greenberg, R. M. (1989). Earcons and icons: Their structure and common design principles. Human–Computer Interaction, 4(1), 11–44.CrossRef Blattner, M. M., Sumikawa, D. A., & Greenberg, R. M. (1989). Earcons and icons: Their structure and common design principles. Human–Computer Interaction, 4(1), 11–44.CrossRef
Zurück zum Zitat Blauert, J. (1997). Spatial hearing: The psychophysics of human sound localization. Cambridge: MIT Press. Blauert, J. (1997). Spatial hearing: The psychophysics of human sound localization. Cambridge: MIT Press.
Zurück zum Zitat Carey, C. W. (2014). American scientists. New York: Infobase Publishing. Carey, C. W. (2014). American scientists. New York: Infobase Publishing.
Zurück zum Zitat Chang, H. T., Tsai, T. H., Chang, Y. C., & Chang, Y. M. (2014). Touch panel usability of elderly and children. Computers in Human Behavior, 37, 258–269.CrossRef Chang, H. T., Tsai, T. H., Chang, Y. C., & Chang, Y. M. (2014). Touch panel usability of elderly and children. Computers in Human Behavior, 37, 258–269.CrossRef
Zurück zum Zitat Chen, J., Cranton, W., & Fihn, M. (Eds.). (2016). Handbook of visual display technology. Berlin, Germany: Springer. Chen, J., Cranton, W., & Fihn, M. (Eds.). (2016). Handbook of visual display technology. Berlin, Germany: Springer.
Zurück zum Zitat Chiou, E. K., Schroeder, N. L., & Craig, S. D. (2020). How we trust, perceive, and learn from virtual humans: The influence of voice quality. Computers & Education, 146, 103756.CrossRef Chiou, E. K., Schroeder, N. L., & Craig, S. D. (2020). How we trust, perceive, and learn from virtual humans: The influence of voice quality. Computers & Education, 146, 103756.CrossRef
Zurück zum Zitat Chouvardas, V. G., Miliou, A. N., & Hatalis, M. K. (2008). Tactile displays: Overview and recent advances. Displays, 29(3), 185–194.CrossRef Chouvardas, V. G., Miliou, A. N., & Hatalis, M. K. (2008). Tactile displays: Overview and recent advances. Displays, 29(3), 185–194.CrossRef
Zurück zum Zitat Clinton, V. (2019). Reading from paper compared to screens: A systematic review and meta-analysis. Journal of Research in Reading, 42(2), 288–325.CrossRef Clinton, V. (2019). Reading from paper compared to screens: A systematic review and meta-analysis. Journal of Research in Reading, 42(2), 288–325.CrossRef
Zurück zum Zitat Crabtree, M., Mirenda, P., & Beukelman, D. (1990). Age and gender preferences for synthetic and natural speech. Augmentative and Alternative Communication, 6(4), 256–261.CrossRef Crabtree, M., Mirenda, P., & Beukelman, D. (1990). Age and gender preferences for synthetic and natural speech. Augmentative and Alternative Communication, 6(4), 256–261.CrossRef
Zurück zum Zitat Craig, S. D., & Schroeder, N. L. (2017). Reconsidering the voice effect when learning from a virtual human. Computers & Education, 114, 193–205.CrossRef Craig, S. D., & Schroeder, N. L. (2017). Reconsidering the voice effect when learning from a virtual human. Computers & Education, 114, 193–205.CrossRef
Zurück zum Zitat Cvach, M. (2012). Monitor alarm fatigue: An integrative review. Biomedical Instrumentation & Technology, 46, 268–277.CrossRef Cvach, M. (2012). Monitor alarm fatigue: An integrative review. Biomedical Instrumentation & Technology, 46, 268–277.CrossRef
Zurück zum Zitat Deatherage, B. H. (1972). Auditory and other sensory forms of information processing. In H. P. Van Cott & R. G. Kincade (Eds.), Human engineering guide to equipment design (pp. 123–160). Washington, DC: American Institutes for Research. Deatherage, B. H. (1972). Auditory and other sensory forms of information processing. In H. P. Van Cott & R. G. Kincade (Eds.), Human engineering guide to equipment design (pp. 123–160). Washington, DC: American Institutes for Research.
Zurück zum Zitat Dingfelder, S. (2008). Too discordant for the masses? Monitor on Psychology, 4, 28. Dingfelder, S. (2008). Too discordant for the masses? Monitor on Psychology, 4, 28.
Zurück zum Zitat Durlach, N. I., Thompson, C. L., & Colburn, H. S. (1981). Binaural interaction in impaired listeners: A review of past research. Audiology, 20(3), 181–211.CrossRef Durlach, N. I., Thompson, C. L., & Colburn, H. S. (1981). Binaural interaction in impaired listeners: A review of past research. Audiology, 20(3), 181–211.CrossRef
Zurück zum Zitat Eckert, M., Volmerg, J. S., & Friedrich, C. M. (2019). Augmented reality in medicine: Systematic and bibliographic review. JMIR mHealth and uHealth, 7(4), e10967.CrossRef Eckert, M., Volmerg, J. S., & Friedrich, C. M. (2019). Augmented reality in medicine: Systematic and bibliographic review. JMIR mHealth and uHealth, 7(4), e10967.CrossRef
Zurück zum Zitat Gerrig, R. J., Zimbardo, P. G., Campbell, A. J., Cumming, S. R., & Wilkes, F. J. (2015). Psychology and life. London: Pearson Higher Education AU. Gerrig, R. J., Zimbardo, P. G., Campbell, A. J., Cumming, S. R., & Wilkes, F. J. (2015). Psychology and life. London: Pearson Higher Education AU.
Zurück zum Zitat Green, D. M., & Luce, R. D. (1971). Detection of auditory signals presented at random times: III. Perception & Psychophysics, 9(3), 257–268.CrossRef Green, D. M., & Luce, R. D. (1971). Detection of auditory signals presented at random times: III. Perception & Psychophysics, 9(3), 257–268.CrossRef
Zurück zum Zitat Grissinger, M. (2016). Drawn curtains, muted alarms, and diverted attention lead to tragedy in the postanesthesia care unit. Pharmacy and Therapeutics, 41(6), 344. Grissinger, M. (2016). Drawn curtains, muted alarms, and diverted attention lead to tragedy in the postanesthesia care unit. Pharmacy and Therapeutics, 41(6), 344.
Zurück zum Zitat Hart, J. A., Lenway, S. A., & Murtha, T. (1999). A history of electroluminescent displays (pp. 1–18). Bloomington: Indiana University. Hart, J. A., Lenway, S. A., & Murtha, T. (1999). A history of electroluminescent displays (pp. 1–18). Bloomington: Indiana University.
Zurück zum Zitat Hellier, E., & Edworthy, J. (1999). On using psychophysical techniques to achieve urgency mapping in auditory warnings. Applied Ergonomics, 30(2), 167–171.CrossRef Hellier, E., & Edworthy, J. (1999). On using psychophysical techniques to achieve urgency mapping in auditory warnings. Applied Ergonomics, 30(2), 167–171.CrossRef
Zurück zum Zitat Himmelstein, A., & Scheiner, M. (1952). The Cardiotachoscope. Anesthesiology, 13(1), 62–64.CrossRef Himmelstein, A., & Scheiner, M. (1952). The Cardiotachoscope. Anesthesiology, 13(1), 62–64.CrossRef
Zurück zum Zitat Holzinger, A., Baernthaler, M., Pammer, W., Katz, H., Bjelic-Radisic, V., & Ziefle, M. (2011). Investigating paper vs. screen in real-life hospital workflows: Performance contradicts perceived superiority of paper in the user experience. International Journal of Human-Computer Studies, 69(9), 563–570.CrossRef Holzinger, A., Baernthaler, M., Pammer, W., Katz, H., Bjelic-Radisic, V., & Ziefle, M. (2011). Investigating paper vs. screen in real-life hospital workflows: Performance contradicts perceived superiority of paper in the user experience. International Journal of Human-Computer Studies, 69(9), 563–570.CrossRef
Zurück zum Zitat Hui, C. J., Jain, S., & Watson, C. I. (2019). Effects of sentence structure and word complexity on intelligibility in machine-to-human communications. Computer Speech & Language, 58, 203–215.CrossRef Hui, C. J., Jain, S., & Watson, C. I. (2019). Effects of sentence structure and word complexity on intelligibility in machine-to-human communications. Computer Speech & Language, 58, 203–215.CrossRef
Zurück zum Zitat Jacobs, G. (1988). The effect of pausing on listening comprehension. ERIC. Jacobs, G. (1988). The effect of pausing on listening comprehension. ERIC.
Zurück zum Zitat Ji, C., Galvin, J. J., III, Xu, A., & Fu, Q. J. (2013). Effect of speaking rate on recognition of synthetic and natural speech by normal-hearing and cochlear implant listeners. Ear and Hearing, 34(3), 313.CrossRef Ji, C., Galvin, J. J., III, Xu, A., & Fu, Q. J. (2013). Effect of speaking rate on recognition of synthetic and natural speech by normal-hearing and cochlear implant listeners. Ear and Hearing, 34(3), 313.CrossRef
Zurück zum Zitat Joint Commission. (2016). R3 report: Alarm system safety. Joint Commission. (2016). R3 report: Alarm system safety.
Zurück zum Zitat Ketko, A. K., Martin, C. M., Nemshak, M. A., Niedner, M., & Vartanian, R. J. (2015). Balancing the tension between hyperoxia prevention and alarm fatigue in the NICU. Pediatrics, 136(2), e496–e504.CrossRef Ketko, A. K., Martin, C. M., Nemshak, M. A., Niedner, M., & Vartanian, R. J. (2015). Balancing the tension between hyperoxia prevention and alarm fatigue in the NICU. Pediatrics, 136(2), e496–e504.CrossRef
Zurück zum Zitat Koomey, J., & Holdren, J. P. (2008). Turning numbers into knowledge: Mastering the art of problem solving. El Dorado Hills, CA: Analytics Press. Koomey, J., & Holdren, J. P. (2008). Turning numbers into knowledge: Mastering the art of problem solving. El Dorado Hills, CA: Analytics Press.
Zurück zum Zitat Lai, J., Wood, D., & Considine, M. (2000). The effect of task conditions on the comprehensibility of synthetic speech. In Proceedings of the SIGCHI conference on human factors in computing systems (pp. 321–328). Lai, J., Wood, D., & Considine, M. (2000). The effect of task conditions on the comprehensibility of synthetic speech. In Proceedings of the SIGCHI conference on human factors in computing systems (pp. 321–328).
Zurück zum Zitat Li, S. Y., Tang, T. L., Hickling, A., Yau, S., Brecknell, B., & Sanderson, P. M. (2017). Spearcons for patient monitoring: Laboratory investigation comparing earcons and spearcons. Human Factors, 59(5), 765–781.CrossRef Li, S. Y., Tang, T. L., Hickling, A., Yau, S., Brecknell, B., & Sanderson, P. M. (2017). Spearcons for patient monitoring: Laboratory investigation comparing earcons and spearcons. Human Factors, 59(5), 765–781.CrossRef
Zurück zum Zitat Liu, P., Zafar, F., & Badano, A. (2014). The effect of ambient illumination on handheld display image quality. Journal of Digital Imaging, 27(1), 12–18.CrossRef Liu, P., Zafar, F., & Badano, A. (2014). The effect of ambient illumination on handheld display image quality. Journal of Digital Imaging, 27(1), 12–18.CrossRef
Zurück zum Zitat Ma, T. Y., Lin, C. Y., Hsu, S. W., Hu, C. W., & Hou, T. W. (2012, May). Automatic brightness control of the handheld device display with low illumination. In 2012 IEEE International Conference on Computer Science and Automation Engineering (CSAE) (Vol. 2, pp. 382–385). Washington, DC: IEEE.CrossRef Ma, T. Y., Lin, C. Y., Hsu, S. W., Hu, C. W., & Hou, T. W. (2012, May). Automatic brightness control of the handheld device display with low illumination. In 2012 IEEE International Conference on Computer Science and Automation Engineering (CSAE) (Vol. 2, pp. 382–385). Washington, DC: IEEE.CrossRef
Zurück zum Zitat Mattys, S. L., Davis, M. H., Bradlow, A. R., & Scott, S. K. (2012). Speech recognition in adverse conditions: A review. Language and Cognitive Processes, 27(7–8), 953–978.CrossRef Mattys, S. L., Davis, M. H., Bradlow, A. R., & Scott, S. K. (2012). Speech recognition in adverse conditions: A review. Language and Cognitive Processes, 27(7–8), 953–978.CrossRef
Zurück zum Zitat Meredith, C., & Edworthy, J. (1995). Are there too many alarms in the intensive care unit? An overview of the problems. Journal of Advanced Nursing, 21(1), 15–20.CrossRef Meredith, C., & Edworthy, J. (1995). Are there too many alarms in the intensive care unit? An overview of the problems. Journal of Advanced Nursing, 21(1), 15–20.CrossRef
Zurück zum Zitat National Research Council. (1997). Tactical display for soldiers: Human factors considerations. Washington, DC: National Academies Press. National Research Council. (1997). Tactical display for soldiers: Human factors considerations. Washington, DC: National Academies Press.
Zurück zum Zitat Nicolau, S., Soler, L., Mutter, D., & Marescaux, J. (2011). Augmented reality in laparoscopic surgical oncology. Surgical Oncology, 20(3), 189–201.CrossRef Nicolau, S., Soler, L., Mutter, D., & Marescaux, J. (2011). Augmented reality in laparoscopic surgical oncology. Surgical Oncology, 20(3), 189–201.CrossRef
Zurück zum Zitat Orphanides, A. K., & Nam, C. S. (2017). Touchscreen interfaces in context: A systematic review of research into touchscreens across settings, populations, and implementations. Applied Ergonomics, 61, 116–143.CrossRef Orphanides, A. K., & Nam, C. S. (2017). Touchscreen interfaces in context: A systematic review of research into touchscreens across settings, populations, and implementations. Applied Ergonomics, 61, 116–143.CrossRef
Zurück zum Zitat Owren, M. J., & Cardillo, G. C. (2006). The relative roles of vowels and consonants in discriminating talker identity versus word meaning. The Journal of the Acoustical Society of America, 119(3), 1727–1739.CrossRef Owren, M. J., & Cardillo, G. C. (2006). The relative roles of vowels and consonants in discriminating talker identity versus word meaning. The Journal of the Acoustical Society of America, 119(3), 1727–1739.CrossRef
Zurück zum Zitat Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., et al. (2016). Systematic review of physiologic monitor alarm characteristics and pragmatic interventions to reduce alarm frequency. Journal of Hospital Medicine, 11(2), 136–144.CrossRef Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., et al. (2016). Systematic review of physiologic monitor alarm characteristics and pragmatic interventions to reduce alarm frequency. Journal of Hospital Medicine, 11(2), 136–144.CrossRef
Zurück zum Zitat Patterson, R. D. (1989). Guidelines for the design of auditory warning sounds. Proceedings of the Institute of Acoustics, 11(5), 17–25. Patterson, R. D. (1989). Guidelines for the design of auditory warning sounds. Proceedings of the Institute of Acoustics, 11(5), 17–25.
Zurück zum Zitat Patterson, R. D. (1990). Auditory warning sounds in the work environment. Philosophical Transactions of the Royal Society of London. B, Biological Sciences, 327(1241), 485–492.CrossRef Patterson, R. D. (1990). Auditory warning sounds in the work environment. Philosophical Transactions of the Royal Society of London. B, Biological Sciences, 327(1241), 485–492.CrossRef
Zurück zum Zitat Phatak, R. (n.d.). Dependence of dark spot growth on cathode/organic interfacial adhesion in Organic Light Emitting Devices (PDF). UWSpace (p. 21). Waterloo: University of Waterloo. Phatak, R. (n.d.). Dependence of dark spot growth on cathode/organic interfacial adhesion in Organic Light Emitting Devices (PDF). UWSpace (p. 21). Waterloo: University of Waterloo.
Zurück zum Zitat Plomp, R., & Levelt, W. J. M. (1965). Tonal consonance and critical bandwidth. The Journal of the Acoustical Society of America, 38(4), 548–560.CrossRef Plomp, R., & Levelt, W. J. M. (1965). Tonal consonance and critical bandwidth. The Journal of the Acoustical Society of America, 38(4), 548–560.CrossRef
Zurück zum Zitat Privopoulos, E. P., Howard, C. Q., & Maddern, A. J. (2011). Acoustic characteristics for effective ambulance sirens. Acoustics Australia, 39(2), 43. Privopoulos, E. P., Howard, C. Q., & Maddern, A. J. (2011). Acoustic characteristics for effective ambulance sirens. Acoustics Australia, 39(2), 43.
Zurück zum Zitat Qutub, H. O., & El-Said, K. F. (2009). Assessment of ambient noise levels in the intensive care unit of a university hospital. Journal of Family & Community Medicine, 16(2), 53. Qutub, H. O., & El-Said, K. F. (2009). Assessment of ambient noise levels in the intensive care unit of a university hospital. Journal of Family & Community Medicine, 16(2), 53.
Zurück zum Zitat Robinson, G. S., & Casali, J. G. (2000). Speech communications and signal detection in noise. The Noise Manual, 5, 567–600. Robinson, G. S., & Casali, J. G. (2000). Speech communications and signal detection in noise. The Noise Manual, 5, 567–600.
Zurück zum Zitat Rogers, M. L., Heath, W. B., Uy, C. C., Suresh, S., & Kaber, D. B. (2012). Effect of visual displays and locations on laparoscopic surgical training tasks. Applied Ergonomics, 43(4), 762–767.CrossRef Rogers, M. L., Heath, W. B., Uy, C. C., Suresh, S., & Kaber, D. B. (2012). Effect of visual displays and locations on laparoscopic surgical training tasks. Applied Ergonomics, 43(4), 762–767.CrossRef
Zurück zum Zitat Ruppel, H., De Vaux, L., Cooper, D., Kunz, S., Duller, B., & Funk, M. (2018). Testing physiologic monitor alarm customization software to reduce alarm rates and improve nurses’ experience of alarms in a medical intensive care unit. PLoS One, 13(10), e0205901.CrossRef Ruppel, H., De Vaux, L., Cooper, D., Kunz, S., Duller, B., & Funk, M. (2018). Testing physiologic monitor alarm customization software to reduce alarm rates and improve nurses’ experience of alarms in a medical intensive care unit. PLoS One, 13(10), e0205901.CrossRef
Zurück zum Zitat Sanders, M. S., & McCormick, E. J. (1993). Human factors in engineering and design (6th ed.). New York: McGraw-Hill. Sanders, M. S., & McCormick, E. J. (1993). Human factors in engineering and design (6th ed.). New York: McGraw-Hill.
Zurück zum Zitat Sanderson, P. M., Brecknell, B., Leong, S., Klueber, S., Wolf, E., Hickling, A., et al. (2019). Monitoring vital signs with time-compressed speech. Journal of Experimental Psychology: Applied, 25, 647. Sanderson, P. M., Brecknell, B., Leong, S., Klueber, S., Wolf, E., Hickling, A., et al. (2019). Monitoring vital signs with time-compressed speech. Journal of Experimental Psychology: Applied, 25, 647.
Zurück zum Zitat Sanderson, P. M., Wee, A., & Lacherez, P. (2006). Learnability and discriminability of melodic medical equipment alarms. Anaesthesia, 61(2), 142–147.CrossRef Sanderson, P. M., Wee, A., & Lacherez, P. (2006). Learnability and discriminability of melodic medical equipment alarms. Anaesthesia, 61(2), 142–147.CrossRef
Zurück zum Zitat Schmid, F., Goepfert, M. S., Kuhnt, D., Eichhorn, V., Diedrichs, S., Reichenspurner, H., et al. (2011). The wolf is crying in the operating room: Patient monitor and anesthesia workstation alarming patterns during cardiac surgery. Anesthesia & Analgesia, 112(1), 78–83.CrossRef Schmid, F., Goepfert, M. S., Kuhnt, D., Eichhorn, V., Diedrichs, S., Reichenspurner, H., et al. (2011). The wolf is crying in the operating room: Patient monitor and anesthesia workstation alarming patterns during cardiac surgery. Anesthesia & Analgesia, 112(1), 78–83.CrossRef
Zurück zum Zitat Schneider, B. A., Daneman, M., & Murphy, D. R. (2005). Speech comprehension difficulties in older adults: Cognitive slowing or age-related changes in hearing? Psychology and Aging, 20(2), 261.CrossRef Schneider, B. A., Daneman, M., & Murphy, D. R. (2005). Speech comprehension difficulties in older adults: Cognitive slowing or age-related changes in hearing? Psychology and Aging, 20(2), 261.CrossRef
Zurück zum Zitat Sielhorst, T., Feuerstein, M., & Navab, N. (2008). Advanced medical displays: A literature review of augmented reality. Journal of Display Technology, 4(4), 451–467.CrossRef Sielhorst, T., Feuerstein, M., & Navab, N. (2008). Advanced medical displays: A literature review of augmented reality. Journal of Display Technology, 4(4), 451–467.CrossRef
Zurück zum Zitat Stanton, N. A., & Edworthy, J. (1999). Auditory warning affordances. In N. Stanton & J. Edworthy (Eds.), Human factors in auditory warnings (pp. 113–127). Surrey, UK: Ashgate. Stanton, N. A., & Edworthy, J. (1999). Auditory warning affordances. In N. Stanton & J. Edworthy (Eds.), Human factors in auditory warnings (pp. 113–127). Surrey, UK: Ashgate.
Zurück zum Zitat Suied, C., Susini, P., & McAdams, S. (2008). Evaluating warning sound urgency with reaction times. Journal of Experimental Psychology: Applied, 14(3), 201. Suied, C., Susini, P., & McAdams, S. (2008). Evaluating warning sound urgency with reaction times. Journal of Experimental Psychology: Applied, 14(3), 201.
Zurück zum Zitat Tang, S. L., Kwoh, C. K., Teo, M. Y., Sing, N. W., & Ling, K. V. (1998). Augmented reality systems for medical applications. IEEE Engineering in Medicine and Biology Magazine, 17(3), 49–58.CrossRef Tang, S. L., Kwoh, C. K., Teo, M. Y., Sing, N. W., & Ling, K. V. (1998). Augmented reality systems for medical applications. IEEE Engineering in Medicine and Biology Magazine, 17(3), 49–58.CrossRef
Zurück zum Zitat van Det, M. J., Meijerink, W. J. H. J., Hoff, C., Totté, E. R., & Pierie, J. P. E. N. (2009). Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: A review and guidelines. Surgical Endoscopy, 23(6), 1279–1285.CrossRef van Det, M. J., Meijerink, W. J. H. J., Hoff, C., Totté, E. R., & Pierie, J. P. E. N. (2009). Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: A review and guidelines. Surgical Endoscopy, 23(6), 1279–1285.CrossRef
Zurück zum Zitat van Veelen, M. A., Jakimowicz, J. J., Goossens, R. H. M., Meijer, D. W., & Bussmann, J. B. J. (2002). Evaluation of the usability of two types of image display systems, during laparoscopy. Surgical Endoscopy, 16(4), 674e678. van Veelen, M. A., Jakimowicz, J. J., Goossens, R. H. M., Meijer, D. W., & Bussmann, J. B. J. (2002). Evaluation of the usability of two types of image display systems, during laparoscopy. Surgical Endoscopy, 16(4), 674e678.
Zurück zum Zitat van Veelen, M. A., Kazemier, G., Koopman, J., Goossens, R. H. M., & Meijer, D. W. (2002). Assessment of the ergonomically optimal operating surface height for laparoscopic surgery. Journal of Laparoendoscopic & Advanced Surgical Techniques, 12(1), 47–52.CrossRef van Veelen, M. A., Kazemier, G., Koopman, J., Goossens, R. H. M., & Meijer, D. W. (2002). Assessment of the ergonomically optimal operating surface height for laparoscopic surgery. Journal of Laparoendoscopic & Advanced Surgical Techniques, 12(1), 47–52.CrossRef
Zurück zum Zitat Walker, B. N., Nance, A., & Lindsay, J. (2006). Spearcons: Speech-based earcons improve navigation performance in auditory menus. Georgia Institute of Technology. Atlanta. Walker, B. N., Nance, A., & Lindsay, J. (2006). Spearcons: Speech-based earcons improve navigation performance in auditory menus. Georgia Institute of Technology. Atlanta.
Zurück zum Zitat Wester, M., Watts, O., & Henter, G. E. (2016). Evaluating comprehension of natural and synthetic conversational speech. In Proc. speech prosody (Vol. 8, pp. 736–740). Wester, M., Watts, O., & Henter, G. E. (2016). Evaluating comprehension of natural and synthetic conversational speech. In Proc. speech prosody (Vol. 8, pp. 736–740).
Zurück zum Zitat Wiklund, M. E., & Smith, E. A. (2001). Answering the call for harmonization of medical device alarms. Medical Device and Diagnostic Industry, 23(10), 118–125. Wiklund, M. E., & Smith, E. A. (2001). Answering the call for harmonization of medical device alarms. Medical Device and Diagnostic Industry, 23(10), 118–125.
Zurück zum Zitat Winters, B. D., Cvach, M. M., Bonafide, C. P., Hu, X., Konkani, A., O’Connor, M. F., et al. (2018). Technological distractions (part 2): A summary of approaches to manage clinical alarms with intent to reduce alarm fatigue. Critical Care Medicine, 46(1), 130–137.CrossRef Winters, B. D., Cvach, M. M., Bonafide, C. P., Hu, X., Konkani, A., O’Connor, M. F., et al. (2018). Technological distractions (part 2): A summary of approaches to manage clinical alarms with intent to reduce alarm fatigue. Critical Care Medicine, 46(1), 130–137.CrossRef
Zurück zum Zitat Withington, D. J., & Chapman, A. C. (1996). Where’s that siren? Science and Public Affairs, 2, 59–61. Withington, D. J., & Chapman, A. C. (1996). Where’s that siren? Science and Public Affairs, 2, 59–61.
Zurück zum Zitat Yost, W. A. (2016). Sound source localization identification accuracy: Level and duration dependencies. The Journal of the Acoustical Society of America, 140(1), EL14–EL19.CrossRef Yost, W. A. (2016). Sound source localization identification accuracy: Level and duration dependencies. The Journal of the Acoustical Society of America, 140(1), EL14–EL19.CrossRef
Zurück zum Zitat Yost, W. A., & Zhong, X. (2014). Sound source localization identification accuracy: Bandwidth dependencies. The Journal of the Acoustical Society of America, 136(5), 2737–2746.CrossRef Yost, W. A., & Zhong, X. (2014). Sound source localization identification accuracy: Bandwidth dependencies. The Journal of the Acoustical Society of America, 136(5), 2737–2746.CrossRef
Zurück zum Zitat Ziefle, M. (1998). Effects of display resolution on visual performance. Human Factors, 40(4), 554–568.CrossRef Ziefle, M. (1998). Effects of display resolution on visual performance. Human Factors, 40(4), 554–568.CrossRef
Metadaten
Titel
Displays
verfasst von
Russell J. Branaghan
Joseph S. O’Brian
Emily A. Hildebrand
L. Bryant Foster
Copyright-Jahr
2021
DOI
https://doi.org/10.1007/978-3-030-64433-8_11

Neuer Inhalt