Abstract

In this paper we are presenting MentorEye system supporting complex oncological procedures. In the past, whole medical content and virtual plan were presented in the operating theater using external monitors. This basic approach was quite difficult for surgeons, because they were distracted from real operation and what is more important to follow virtual plan realization, they lost their direct eye contact with the operating field. Huge development in head mounted displays (HMD) technology creates an opportunity to use this kind of presenters interoperatively. First of all, they are quite small and user friendly, and content presentation can be from an egocentric point of view. In this paper, we show different HMD models and their potential usage in computer aided surgery. Finally, calibration procedure is validated to support virtual plan visualization directly in the front of surgeon eyes.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Kolodzey, L., Grantcharov, P., Rivas, H.: Wearable technology in the operating room: a systematic review. BMJ Innovations 2(4), 139–140 (2016)CrossRef Kolodzey, L., Grantcharov, P., Rivas, H.: Wearable technology in the operating room: a systematic review. BMJ Innovations 2(4), 139–140 (2016)CrossRef
2.
Zurück zum Zitat Swiatek-Najwer, E., Majak, M., Zuk, M., Popek, M., Kulas, Z., Jaworowski, J., Pietruski, P.: The new computer and fluorescence-guided system for planning and aiding oncological treatment. In: Computer Assisted Radiology and Surgery–Proceedings of the 31–th International Congress and Exhibition, Barcelona 2017. Int J CARS (2017) 12 (Suppl 1):S1–S286 Swiatek-Najwer, E., Majak, M., Zuk, M., Popek, M., Kulas, Z., Jaworowski, J., Pietruski, P.: The new computer and fluorescence-guided system for planning and aiding oncological treatment. In: Computer Assisted Radiology and Surgery–Proceedings of the 31–th International Congress and Exhibition, Barcelona 2017. Int J CARS (2017) 12 (Suppl 1):S1–S286
3.
Zurück zum Zitat Mondal, S., Gao, S., Zhu, N.: Binocular goggle augmented imaging and navigation system provides real-time fluorescence image guidance for tumor resection and sentinel lymph node mapping. Sci. Rep. 5, 12117 (2015)CrossRef Mondal, S., Gao, S., Zhu, N.: Binocular goggle augmented imaging and navigation system provides real-time fluorescence image guidance for tumor resection and sentinel lymph node mapping. Sci. Rep. 5, 12117 (2015)CrossRef
4.
Zurück zum Zitat Mondal, S., Gao, S., Zhu, N.: Optical see-through cancer vision goggles enable direct patient visualization and real-time fluorescence-guided oncologic surgery. Ann. Surg. Oncol. (2017) Mondal, S., Gao, S., Zhu, N.: Optical see-through cancer vision goggles enable direct patient visualization and real-time fluorescence-guided oncologic surgery. Ann. Surg. Oncol. (2017)
5.
Zurück zum Zitat Xiaojun, C., Xu, L., Yiping, W., Huixiang, W., Fang, W., Xiangsen, Z., Qiugen, W., Jan, E.: Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display. J. Biomed. Inform. 55, 124–131 (2015)CrossRef Xiaojun, C., Xu, L., Yiping, W., Huixiang, W., Fang, W., Xiangsen, Z., Qiugen, W., Jan, E.: Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display. J. Biomed. Inform. 55, 124–131 (2015)CrossRef
6.
Zurück zum Zitat Tuceryan, M., Navab, N.: Single point active alignment method (SPAAM) for optical see-through HMD calibration for AR. ISAR (2002) Tuceryan, M., Navab, N.: Single point active alignment method (SPAAM) for optical see-through HMD calibration for AR. ISAR (2002)
7.
Zurück zum Zitat Moser, K., Swan, E.: Evaluation of user-centric optical see-through head-mounted display calibration using a leap motion controller. In: 2016 IEEE Symposium on 3D User Interfaces (3DUI) (2016) Moser, K., Swan, E.: Evaluation of user-centric optical see-through head-mounted display calibration using a leap motion controller. In: 2016 IEEE Symposium on 3D User Interfaces (3DUI) (2016)
8.
Zurück zum Zitat Pietruski, P., Majak, M., Wiatek-Najwer, E., Popek, M., Jaworowski, J., Zuk, M., Nowakowski, F.: Image-guided bone resection as a prospective alternative to cutting templates-a preliminary study. J. Cranio-Maxillofacial Surg. 43(7), 1021–1027 (2015)CrossRef Pietruski, P., Majak, M., Wiatek-Najwer, E., Popek, M., Jaworowski, J., Zuk, M., Nowakowski, F.: Image-guided bone resection as a prospective alternative to cutting templates-a preliminary study. J. Cranio-Maxillofacial Surg. 43(7), 1021–1027 (2015)CrossRef
9.
Zurück zum Zitat Pietruski, P., Majak, M., Swiatek-Najwer, E., Popek, M., Szram, D., Zuk, M., Jaworowski, J.: Accuracy of experimental mandibular osteotomy using the image-guided sagittal saw. Int. J. Oral Maxillofacial Surg. 45(6), 793–800 (2016)CrossRef Pietruski, P., Majak, M., Swiatek-Najwer, E., Popek, M., Szram, D., Zuk, M., Jaworowski, J.: Accuracy of experimental mandibular osteotomy using the image-guided sagittal saw. Int. J. Oral Maxillofacial Surg. 45(6), 793–800 (2016)CrossRef
Metadaten
Titel
Evaluation of Calibration Procedure for Stereoscopic Visualization Using Optical See-Through Head Mounted Displays for a Complex Oncological Treatment
verfasst von
Magdalena Zuk
Marcin Majak
Ewelina Swiatek-Najwer
Michal Popek
Zbigniew Kulas
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-319-68195-5_39

Neuer Inhalt