Skip to main content

2020 | OriginalPaper | Buchkapitel

Experimental Study on a Facade-Built-in Two-Phase Thermosyphon Loop for Passive Thermo-Activated Building System

verfasst von : Li Zhu, Yang Yang, Jiqiang Zhang, Sarula Chen, Yong Sun

Erschienen in: Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019)

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A novel facade-built-in thermosyphon loop (TPTL) for passive thermo-activated building system was proposed in this paper. The feasibility and effect of the filling ratio as well as the heat source temperature on the operation performance were investigated through the experimental method. Results show that the filling ratio has a great impact on the performance of the facade-built-in TPTL. There exists an optimal filling ratio to achieve a better heat transfer performance under different operation temperatures. The filling ratio of 88% is found to be the optimum filling ratio for the prototype based on the performance indicator of the total heat transfer resistance. Under the optimum ratio condition, the heat transfer rate of the facade-built-in TPTL could reach up to about 132–300 W when heat source temperature maintains at 35–55 °C.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Gwerder, M., Lehmann, B., et al.: Control of thermally-activated building systems (TABs). Appl. Energy 85(7), 565–581 (2008)CrossRef Gwerder, M., Lehmann, B., et al.: Control of thermally-activated building systems (TABs). Appl. Energy 85(7), 565–581 (2008)CrossRef
2.
Zurück zum Zitat Ma, P., Wang, L.S., Guo, N.: Energy storage and heat extraction—from thermally activated building systems (TABS) to thermally homeostatic buildings. Renew. Sustain. Energy Rev. 45, 677–685 (2015)CrossRef Ma, P., Wang, L.S., Guo, N.: Energy storage and heat extraction—from thermally activated building systems (TABS) to thermally homeostatic buildings. Renew. Sustain. Energy Rev. 45, 677–685 (2015)CrossRef
3.
Zurück zum Zitat Li, A., Xu, X., Sun, Y.: A study on pipe-embedded wall integrated with ground source-coupled heat exchanger for enhanced building energy efficiency in diverse climate regions. Energy Build. 121, 139–151 (2016)CrossRef Li, A., Xu, X., Sun, Y.: A study on pipe-embedded wall integrated with ground source-coupled heat exchanger for enhanced building energy efficiency in diverse climate regions. Energy Build. 121, 139–151 (2016)CrossRef
4.
Zurück zum Zitat Zhu, Q., Li, A., et al.: Experimental validation of a semi-dynamic simplified model of active pipe-embedded building envelope. Int. J. Therm. Sci. 108, 70–80 (2016)CrossRef Zhu, Q., Li, A., et al.: Experimental validation of a semi-dynamic simplified model of active pipe-embedded building envelope. Int. J. Therm. Sci. 108, 70–80 (2016)CrossRef
5.
Zurück zum Zitat Ibrahim, M., Wurtz, E., et al.: Transferring the south solar energy to the north facade through embedded water pipes. Energy 78, 834–845 (2014)CrossRef Ibrahim, M., Wurtz, E., et al.: Transferring the south solar energy to the north facade through embedded water pipes. Energy 78, 834–845 (2014)CrossRef
6.
Zurück zum Zitat Chehade, A.A., Louahlia-Gualous, H., Le Masson, S., et al.: Experimental investigation of thermosyphon loop thermal performance. Energy Convers. Manag. 84, 671–680 (2014)CrossRef Chehade, A.A., Louahlia-Gualous, H., Le Masson, S., et al.: Experimental investigation of thermosyphon loop thermal performance. Energy Convers. Manag. 84, 671–680 (2014)CrossRef
7.
Zurück zum Zitat Tong, Z., Liu, X.H., Jiang, Y.: Experimental study of the self-regulating performance of an R744 two-phase thermosyphon loop. Appl. Energy 186, 1–12 (2017)CrossRef Tong, Z., Liu, X.H., Jiang, Y.: Experimental study of the self-regulating performance of an R744 two-phase thermosyphon loop. Appl. Energy 186, 1–12 (2017)CrossRef
Metadaten
Titel
Experimental Study on a Facade-Built-in Two-Phase Thermosyphon Loop for Passive Thermo-Activated Building System
verfasst von
Li Zhu
Yang Yang
Jiqiang Zhang
Sarula Chen
Yong Sun
Copyright-Jahr
2020
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-9528-4_148