Skip to main content

2015 | OriginalPaper | Buchkapitel

Experimental Study on Performance of Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation System

verfasst von : Xue-ying Xia, Xu Zhang

Erschienen in: Low-carbon City and New-type Urbanization

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Experimental investigations were carried out to study the performance of lightweight radiant floor cooling combined with underfloor ventilation (LRFCUV) system. Operating parameters of LRFCUV system were recorded. Operating characteristic, heat-transfer capability, and thermal comfort of LRFCUV were analyzed based on experimental data. Experimental results indicate that thermal resistance of lightweight floor structure is considerable. Radiant heat-transfer capability occupies approximately 30 % of the total, and LRFCUV system shows fine thermal stability and thermal comfort.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Conceição EZE, Lúcio MMJR (2011) Evaluation of thermal comfort conditions in a classroom equipped with radiant cooling systems and subjected to uniform convective environment. Appl Math Model 35:1292–1305 Conceição EZE, Lúcio MMJR (2011) Evaluation of thermal comfort conditions in a classroom equipped with radiant cooling systems and subjected to uniform convective environment. Appl Math Model 35:1292–1305
Zurück zum Zitat Hu R, Niu JL (2012) A review of the application of radiant cooling and heating systems in Mainland China. Energy Build 52:11–19CrossRef Hu R, Niu JL (2012) A review of the application of radiant cooling and heating systems in Mainland China. Energy Build 52:11–19CrossRef
Zurück zum Zitat Jin X, Zhang XS, Luo YJ (2010a) A calculation method for the floor surface temperature in radiant floor system. Energy Build 42:1753–1758CrossRef Jin X, Zhang XS, Luo YJ (2010a) A calculation method for the floor surface temperature in radiant floor system. Energy Build 42:1753–1758CrossRef
Zurück zum Zitat Jin X, Zhang XS, Luo YJ (2010b) Numerical simulation of radiant floor cooling system: the effects of thermal resistance of pipe and water velocity on the performance. Energy Build 45:2545–2552CrossRef Jin X, Zhang XS, Luo YJ (2010b) Numerical simulation of radiant floor cooling system: the effects of thermal resistance of pipe and water velocity on the performance. Energy Build 45:2545–2552CrossRef
Zurück zum Zitat Leigh SB, Song DS, Hwang SH et al (2005) A study for evaluating performance of radiant floor cooling integrated with controlled ventilation. ASHRAE Trans 111:71–82 Leigh SB, Song DS, Hwang SH et al (2005) A study for evaluating performance of radiant floor cooling integrated with controlled ventilation. ASHRAE Trans 111:71–82
Zurück zum Zitat Memon RA, Chirarattananon S, Vangtook P (2008) Thermal comfort assessment and application of radiant cooling: a case study. Build Environ 43:1185–1196 Memon RA, Chirarattananon S, Vangtook P (2008) Thermal comfort assessment and application of radiant cooling: a case study. Build Environ 43:1185–1196
Zurück zum Zitat Qiu L, Liu ZS et al (2005) Feasibility study on floor heating by application of prestressed concrete hollow floor and dry floor structure. Build Sci 21:44–47 (in Chinese) Qiu L, Liu ZS et al (2005) Feasibility study on floor heating by application of prestressed concrete hollow floor and dry floor structure. Build Sci 21:44–47 (in Chinese)
Zurück zum Zitat Qi ZX, Lu YJ (2002) Dry modus of water heating system. Build Energy Environ 1:32–34 (in Chinese)MATH Qi ZX, Lu YJ (2002) Dry modus of water heating system. Build Energy Environ 1:32–34 (in Chinese)MATH
Zurück zum Zitat Qiu L, Wang WH, Zheng SH (2005) Experimental research on radiant cooling of a dry structure floor system. Fluid Mach 33:68–71 (in Chinese) Qiu L, Wang WH, Zheng SH (2005) Experimental research on radiant cooling of a dry structure floor system. Fluid Mach 33:68–71 (in Chinese)
Zurück zum Zitat Song D, Kim T, Song S et al (2008) Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. Appl Therm Eng 28:1299–1311CrossRef Song D, Kim T, Song S et al (2008) Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. Appl Therm Eng 28:1299–1311CrossRef
Zurück zum Zitat Strand RK, Baumgartner KT (2005) Modeling radiant heating and cooling systems: integration with a whole-building simulation program. Energy Build 37:389–397CrossRef Strand RK, Baumgartner KT (2005) Modeling radiant heating and cooling systems: integration with a whole-building simulation program. Energy Build 37:389–397CrossRef
Zurück zum Zitat Tian Z, Love JA (2008) A field study of occupant thermal comfort and thermal environments with radiant slab cooling. Build Environ 43:1658–1670 Tian Z, Love JA (2008) A field study of occupant thermal comfort and thermal environments with radiant slab cooling. Build Environ 43:1658–1670
Zurück zum Zitat Tye-Gingras M, Gosselin L (2011) Investigation on heat transfer modeling assumptions for radiant panels with serpentine layout. Energy Build 43:1598–1608CrossRef Tye-Gingras M, Gosselin L (2011) Investigation on heat transfer modeling assumptions for radiant panels with serpentine layout. Energy Build 43:1598–1608CrossRef
Zurück zum Zitat Weitzmann P, Svendsen S (2005) Method for calculating thermal properties of lightweight floor heating panels based on an experimental setup. Int J Low Energy Sustain Build 3:1–15 Weitzmann P, Svendsen S (2005) Method for calculating thermal properties of lightweight floor heating panels based on an experimental setup. Int J Low Energy Sustain Build 3:1–15
Zurück zum Zitat Yu QZ (1990) Radiant heat-transfer foundation, 1st edn. Higher Education Press, Beijing (in Chinese) Yu QZ (1990) Radiant heat-transfer foundation, 1st edn. Higher Education Press, Beijing (in Chinese)
Zurück zum Zitat Zhang DL, Cai N, Wang ZJ (2013) Experimental and numerical analysis of lightweight radiant floor heating system. Energy Build 61:260–266 Zhang DL, Cai N, Wang ZJ (2013) Experimental and numerical analysis of lightweight radiant floor heating system. Energy Build 61:260–266
Zurück zum Zitat Zhang L, Liu XH, Jiang Y (2012) Simplified calculation for cooling/heating capacity, surface temperature distribution of radiant floor. Energy Build 55:397–404CrossRef Zhang L, Liu XH, Jiang Y (2012) Simplified calculation for cooling/heating capacity, surface temperature distribution of radiant floor. Energy Build 55:397–404CrossRef
Metadaten
Titel
Experimental Study on Performance of Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation System
verfasst von
Xue-ying Xia
Xu Zhang
Copyright-Jahr
2015
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-45969-0_27