Skip to main content
Erschienen in: Energy Efficiency 5/2019

29.03.2019 | Original Article

How do data centers make energy efficiency investment decisions? Qualitative evidence from focus groups and interviews

verfasst von: Heather Klemick, Elizabeth Kopits, Ann Wolverton

Erschienen in: Energy Efficiency | Ausgabe 5/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The data center industry is one of the fastest growing energy users in the USA. While the industry has improved its energy efficiency over the past decade, engineering analyses suggest that ample opportunities remain to reduce energy use that would save firms money. This study explores whether and why data centers might limit investment in energy efficiency. Given the scarcity of empirical data in this context, we conducted focus groups and interviews with data center managers to elicit information about factors affecting their investments and used content analysis to qualitatively evaluate the results. Split incentives between departments within companies and between colocation data centers and their tenants, imperfect information about the performance of new technologies, and tradeoffs with data center reliability were the most pervasive factors discussed by participants. While we find some evidence that market failure explanations such as split incentives and imperfect information had a limited role in slowing adoption for participants, rival explanations such as the cost of acquiring context-specific information, and opportunity costs associated with alternate uses of funds or highly valued attributes played a larger role in slowing investment in energy efficiency.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Fußnoten
1
For a discussion of trends in data center energy efficiency in Europe, see Avgerinou et al. (2017).
 
2
A 2013 California regulation mandates the use of specific energy-efficient cooling, airflow, and fan technologies in data centers (California Building Standards Commission 2013). Energy consumption for the rest of the industry remains unregulated in the USA, despite a few federal initiatives to promote best practices.
 
3
The presence of unpriced negative externalities, such as greenhouse gases and other air pollutants, also leads to market failures, but externalities are not expected to be factored into firms’ private profit maximization decisions so we do not consider them here.
 
4
A profit-maximizing firm invests until the additional benefit from the investment just equals the additional cost.
 
5
The hypotheses we discuss are consistent with Sorrell et al. (2011) and Thollander et al. (2010).
 
6
Conversely, it is possible that there are synergies between energy efficiency and other attributes, meaning that improvements in energy efficiency could actually lead to greater reliability or product quality in some cases. See “Tradeoffs between energy efficiency and other factors” section for a discussion in the context of data centers.
 
7
A semi-structured approach uses a moderator’s guide, which lists the questions and topics to be discussed across interviews and focus groups. This approach allows the interviewer or moderator some discretion regarding the order in which the questions are asked and provides prompts to indicate when a topic is worthy of follow-up to facilitate a deeper understanding of a given topic as it relates to the hypotheses of interest.
 
8
The questionnaire and moderator’s guide are available in an online appendix.
 
9
Given the technical nature of the discussions and the fact that participants did not have access to questions ahead of time, we interpreted filler words—“um” or “err” or pauses—as indicative of a participant trying to gather his or her thoughts. These types of words were eliminated in the speech-to-text conversation process; we did not omit other informal speech mannerisms that might conceivably convey meaning.
 
10
This form of coding is sometimes referred to as hypothesis coding and is a common approach to content analysis when attempting to assess researcher-generated hypotheses (Miles et al. 2014).
 
11
We also used sub-codes. For instance, a discussion that was coded as “tradeoffs with other attributes” and “widely viewed as a slowing adoption” would also be tagged with “reliability” if it discussed how a technology affects performance, redundancy, uptime, or reliability.
 
12
Focus groups (FG) and interviews (INT) are labeled numerically throughout the document.
 
13
Four focus groups were held at Data Center Dynamics conferences in Dallas and New York, and two focus groups were held at an AFCOM conference in Boston.
 
14
Excluding this sector could potentially bias our sample. However, the proportion of US servers in federal government data centers fell from roughly 5–10% in 2007 to 1–2% in 2012–2014 (Shehabi et al. 2016). Our sample does include private companies that provided computing services to federal government users.
 
15
EPA and DOE’s Energy STAR buildings program recognizes top performers in energy efficiency through certification of individual facilities as well as portfolios of buildings or plants.
 
16
The degree to which a data center operated as a colocation facility varied from less than 10 to over 90% of racks. More than half of the sample also leased space from others, though 25% leased a relatively small portion (i.e., 20% or less). In addition, most data centers occasionally outsourced facility management.
 
17
Barriers that prevent mixing of incoming cold air and hot exhaust air (cold- or hot-aisle containment), tiles that guide cool air to servers (directional floor tiles, blanking panels), air conditioning unit devices that allow air flow to vary as cooling demand fluctuates (variable fan or speed drives), and higher temperature set points are frequently described as paying back in less than 2 years. Company statements and research indicate that investments in cooling method often have higher upfront costs, particularly retrofits, but can still yield large energy savings in some circumstances. See Van Geet (2017), Pacific West Air Conditioning (2014), Green Grid (2011), Wathaifi (2009), and https://​www.​energystar.​gov/​products/​low_​carbon_​it_​campaign/​12_​ways_​save_​energy_​data_​center/​.
 
18
This finding is consistent with Cooremans (2012) regarding the importance of investment characteristics in decision-making.
 
19
A PUE of one indicates that a data center uses no additional power for lighting, cooling, power distribution, or facility operation beyond what is drawn by the IT equipment; a PUE of two indicates that for every unit of power consumed by IT equipment, another unit is used for facility operation. Participants reported a median PUE of 1.7 for localized facilities, 1.55 for enterprise facilities, and 1.4 for mega/utility-scale data centers.
 
20
Howard and Holmes (2012) also found evidence of split incentives between the facilities and IT departments for the data centers they interviewed. They found that having one person responsible for both facilities and IT equipment decisions was more common among companies whose core business was data center services.
 
21
While we do not know exactly how many participants rely on internal vs. external financing, discussion suggested they use a mix. Cooremans (2012) and Klemick et al. (2017) found that internal financing is prevalent in other sectors; as here, energy efficiency often competes with non-energy investments for internal capital.
 
22
For an overview of incentive and rebate programs offered by utilities, see Howard and Holmes (2012).
 
23
Mills et al. (2008) also pointed out that energy efficiency improvements in high-tech industries such as data centers often compete internally with other capital investments that pay off very quickly.
 
24
These statements are consistent with Mills et al. (2008): risks of power failure are often overestimated, resulting in “overdesign” of backup systems and “strict emphasis on proven reliable technologies.” Howard and Holmes (2012) noted that a major challenge to improving data center energy efficiency is an “extreme focus on reliability.”
 
Literatur
Zurück zum Zitat Andrews, C. J., & Krogmann, U. (2009). Explaining the adoption of energy-efficient technologies in U.S. commercial buildings. Energy and Buildings, 41, 287–294.CrossRef Andrews, C. J., & Krogmann, U. (2009). Explaining the adoption of energy-efficient technologies in U.S. commercial buildings. Energy and Buildings, 41, 287–294.CrossRef
Zurück zum Zitat Avgerinou, M., Bertoldi, P., & Castellazzi, L. (2017). Trends in data centre energy consumption under the European code of conduct for data center energy efficiency. Energies, 10, 1470–1487.CrossRef Avgerinou, M., Bertoldi, P., & Castellazzi, L. (2017). Trends in data centre energy consumption under the European code of conduct for data center energy efficiency. Energies, 10, 1470–1487.CrossRef
Zurück zum Zitat Brunke, J.-C., Johansson, M., & Thollander, P. (2014). Empirical investigation of barriers and drivers to the adoption of energy conservation measures, energy management practices and energy services in the Swedish iron and steel industry. Journal of Cleaner Production, 84, 509–525.CrossRef Brunke, J.-C., Johansson, M., & Thollander, P. (2014). Empirical investigation of barriers and drivers to the adoption of energy conservation measures, energy management practices and energy services in the Swedish iron and steel industry. Journal of Cleaner Production, 84, 509–525.CrossRef
Zurück zum Zitat Cooremans, C. (2011). Make it strategic! Financial investment logic is not enough. Energy Efficiency, 4, 473–492.CrossRef Cooremans, C. (2011). Make it strategic! Financial investment logic is not enough. Energy Efficiency, 4, 473–492.CrossRef
Zurück zum Zitat Cooremans, C. (2012). Investment in energy efficiency: do the characteristics of investments matter? Energy Efficiency, 5, 497–518.CrossRef Cooremans, C. (2012). Investment in energy efficiency: do the characteristics of investments matter? Energy Efficiency, 5, 497–518.CrossRef
Zurück zum Zitat Dixon-O’Mara, C., & Ryan, L. (2018). Energy efficiency in the food retail sector: barriers, drivers, and acceptable policies. Energy Efficiency, 11(2), 445-464. Dixon-O’Mara, C., & Ryan, L. (2018). Energy efficiency in the food retail sector: barriers, drivers, and acceptable policies. Energy Efficiency, 11(2), 445-464.
Zurück zum Zitat Frechtling, J., and L. Sharp, eds. 1997. User-Friendly Handbook for Mixed Method Evaluations. Produced for the National Science Foundation Frechtling, J., and L. Sharp, eds. 1997. User-Friendly Handbook for Mixed Method Evaluations. Produced for the National Science Foundation
Zurück zum Zitat Gerarden, T., Newell, R., & Stavins, R. (2017). Assessing the energy-efficiency gap. Journal of Economic Literature, 55(4), 1486–1525.CrossRef Gerarden, T., Newell, R., & Stavins, R. (2017). Assessing the energy-efficiency gap. Journal of Economic Literature, 55(4), 1486–1525.CrossRef
Zurück zum Zitat Gillingham, K., Newell, R., & Palmer, K. (2009). Energy efficiency economics and policy. Annual Review of Resource Economics, 1, 597–620.CrossRef Gillingham, K., Newell, R., & Palmer, K. (2009). Energy efficiency economics and policy. Annual Review of Resource Economics, 1, 597–620.CrossRef
Zurück zum Zitat Gul, M., & Menzies, G. (2012). Designing domestic buildings for future summers: attitudes and opinions of building professionals. Energy Policy, 45, 752–761.CrossRef Gul, M., & Menzies, G. (2012). Designing domestic buildings for future summers: attitudes and opinions of building professionals. Energy Policy, 45, 752–761.CrossRef
Zurück zum Zitat Howard, A., & Holmes, J. (2012). Addressing data center efficiency: lessons learned from process evaluations of utility energy efficiency programs. Energy Efficiency, 5, 137–148.CrossRef Howard, A., & Holmes, J. (2012). Addressing data center efficiency: lessons learned from process evaluations of utility energy efficiency programs. Energy Efficiency, 5, 137–148.CrossRef
Zurück zum Zitat Huntington, H. 2011. “The Policy Implications of Energy-Efficiency Curves.” Energy Journal, Special Issue: 7–22. Huntington, H. 2011. “The Policy Implications of Energy-Efficiency Curves.” Energy Journal, Special Issue: 7–22.
Zurück zum Zitat Hsieh, H.-F., & Shannon, S. (2005). Three approaches to qualitative content analysis. Qualitative Health Research, 15(9), 1277–1288.CrossRef Hsieh, H.-F., & Shannon, S. (2005). Three approaches to qualitative content analysis. Qualitative Health Research, 15(9), 1277–1288.CrossRef
Zurück zum Zitat Jaccard, M. 2010. “Paradigms of Energy Efficiency's Cost and Their Policy Implications: Deja Vu All Over Again.” Modeling the Economics of Greenhouse Gas Mitigation: Summary of a Workshop. National Research Council. National Academies Press. Washington, D.C. Jaccard, M. 2010. “Paradigms of Energy Efficiency's Cost and Their Policy Implications: Deja Vu All Over Again.” Modeling the Economics of Greenhouse Gas Mitigation: Summary of a Workshop. National Research Council. National Academies Press. Washington, D.C.
Zurück zum Zitat Jaffe, A., & Stavins, R. (1994). The energy-efficiency gap: What does it mean? Energy Policy, 22, 804–810.CrossRef Jaffe, A., & Stavins, R. (1994). The energy-efficiency gap: What does it mean? Energy Policy, 22, 804–810.CrossRef
Zurück zum Zitat Klemick, H., Kopits, E., Wolverton, A., & Sargent, K. (2015). Heavy-duty trucking and the energy efficiency paradox: evidence from focus groups and interviews. Transportation Research Part A: Policy and Practice, 77, 154–166. Klemick, H., Kopits, E., Wolverton, A., & Sargent, K. (2015). Heavy-duty trucking and the energy efficiency paradox: evidence from focus groups and interviews. Transportation Research Part A: Policy and Practice, 77, 154–166.
Zurück zum Zitat Klemick, H., Kopits, E., & Wolverton, A. (2017). Potential barriers to improving energy efficiency in commercial buildings: the case of supermarket refrigeration. Journal of Benefit Cost Analysis, 8(1), 1–31.CrossRef Klemick, H., Kopits, E., & Wolverton, A. (2017). Potential barriers to improving energy efficiency in commercial buildings: the case of supermarket refrigeration. Journal of Benefit Cost Analysis, 8(1), 1–31.CrossRef
Zurück zum Zitat Miles, M., Huberman, A., & Saldaña, J. (2014). Qualitative data analysis: a methods sourcebook (Third ed.). Thousand Oaks: Sage Publications. Miles, M., Huberman, A., & Saldaña, J. (2014). Qualitative data analysis: a methods sourcebook (Third ed.). Thousand Oaks: Sage Publications.
Zurück zum Zitat Mills, E., Shamshoian, G., Blazek, M., Naughton, P., Seese, R., Tschudi, W., et al. (2008). The business case for energy management in high-tech industries. Energy Efficiency, 1, 5–20.CrossRef Mills, E., Shamshoian, G., Blazek, M., Naughton, P., Seese, R., Tschudi, W., et al. (2008). The business case for energy management in high-tech industries. Energy Efficiency, 1, 5–20.CrossRef
Zurück zum Zitat Ochieng, E., Jones, N., Price, A., Ruan, X., Egbu, C., & Zuofa, T. (2014). Integration of energy efficient technologies in UK supermarkets. Energy Policy, 67, 388–393.CrossRef Ochieng, E., Jones, N., Price, A., Ruan, X., Egbu, C., & Zuofa, T. (2014). Integration of energy efficient technologies in UK supermarkets. Energy Policy, 67, 388–393.CrossRef
Zurück zum Zitat Olson, M. (1965). The logic of collective action: public goods and the theory of groups. Cambridge: Harvard University Press. Olson, M. (1965). The logic of collective action: public goods and the theory of groups. Cambridge: Harvard University Press.
Zurück zum Zitat Palm, J., & Reindl, K. (2018). Understanding barriers to energy-efficiency renovations of multifamily dwellings. Energy Efficiency, 11, 53–65.CrossRef Palm, J., & Reindl, K. (2018). Understanding barriers to energy-efficiency renovations of multifamily dwellings. Energy Efficiency, 11, 53–65.CrossRef
Zurück zum Zitat Pellegrini-Masini, G., & Leishman, C. (2011). The role of corporate reputation and employees’ values in the uptake of energy efficiency in office buildings. Energy Policy, 39, 5409–5419.CrossRef Pellegrini-Masini, G., & Leishman, C. (2011). The role of corporate reputation and employees’ values in the uptake of energy efficiency in office buildings. Energy Policy, 39, 5409–5419.CrossRef
Zurück zum Zitat Radcliff, B., & Best, S. (Eds.). (2005). Polling America: an encyclopedia of public opinion research. Westport: Greenwood Press. Radcliff, B., & Best, S. (Eds.). (2005). Polling America: an encyclopedia of public opinion research. Westport: Greenwood Press.
Zurück zum Zitat Schleich, J., & Gruber, E. (2008). Beyond case studies: barriers to energy efficiency in commerce and the services sector. Energy Economics, 30, 449–464.CrossRef Schleich, J., & Gruber, E. (2008). Beyond case studies: barriers to energy efficiency in commerce and the services sector. Energy Economics, 30, 449–464.CrossRef
Zurück zum Zitat Sorrell, S., Mallett, A., & Nye, S. (2011). Barriers to industrial energy efficiency: a literature review. United Nations Industrial Development Organization. Working Paper 10/2011. Sorrell, S., Mallett, A., & Nye, S. (2011). Barriers to industrial energy efficiency: a literature review. United Nations Industrial Development Organization. Working Paper 10/2011.
Zurück zum Zitat Sullivan, R., & Gouldson, A. (2013). Ten years of corporate action on climate change: what do we have to show for it? Energy Policy, 60, 733–740.CrossRef Sullivan, R., & Gouldson, A. (2013). Ten years of corporate action on climate change: what do we have to show for it? Energy Policy, 60, 733–740.CrossRef
Zurück zum Zitat Thollander, P., & Ottosson, M. (2008). An energy efficient Swedish pulp and paper industry – exploring barriers to and driving forces for cost-effective energy efficiency investments. Energy Efficiency, 1, 21–34.CrossRef Thollander, P., & Ottosson, M. (2008). An energy efficient Swedish pulp and paper industry – exploring barriers to and driving forces for cost-effective energy efficiency investments. Energy Efficiency, 1, 21–34.CrossRef
Zurück zum Zitat Wathaifi, M. H. (2009). Free cooling using water-side economizer: process cooling application at a plastic extrusion plant. Energy Engineering, 106(6), 45–78.CrossRef Wathaifi, M. H. (2009). Free cooling using water-side economizer: process cooling application at a plastic extrusion plant. Energy Engineering, 106(6), 45–78.CrossRef
Zurück zum Zitat Yin, R. K. (2003). Case study research: design and methods (Third ed.). Thousand Oaks: Sage Publications. Yin, R. K. (2003). Case study research: design and methods (Third ed.). Thousand Oaks: Sage Publications.
Metadaten
Titel
How do data centers make energy efficiency investment decisions? Qualitative evidence from focus groups and interviews
verfasst von
Heather Klemick
Elizabeth Kopits
Ann Wolverton
Publikationsdatum
29.03.2019
Verlag
Springer Netherlands
Erschienen in
Energy Efficiency / Ausgabe 5/2019
Print ISSN: 1570-646X
Elektronische ISSN: 1570-6478
DOI
https://doi.org/10.1007/s12053-019-09782-2

Weitere Artikel der Ausgabe 5/2019

Energy Efficiency 5/2019 Zur Ausgabe