Skip to main content

2023 | OriginalPaper | Buchkapitel

Implanted Pediatric Patient Early Audiometry

verfasst von : Juan Manuel Cornejo Cruz, Agar Karina Quintana López, Ma. del Pilar Granados Trejo

Erschienen in: XLV Mexican Conference on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Conventional audiometry reliability is reached after a variable length period when is applied to implanted pediatric patients, hence delaying auditory rehabilitation therapy decision-making. This work deals with the implanted pediatric patient sound field audiometry early estimation by using the Electrical Cochlear Response (ECR) threshold, which is obtained while patient is using her/his cochlear implant (CI) functioning in everyday mode. In a transversal study, sound field audiometry and ECR thresholds were obtained in a group of 34 prelingual pediatric implanted patients, ranged in age from 1.8 to 6 years, and grouped by age and CI use time. ECR thresholds profile and sound field audiometry show the same tendency over patient age and device use time, however ECR thresholds show a stable behavior across age and device use in contrast to sound field audiometry. Sound field audiometry had higher standard deviation for short age patients and scanty device use. There was a significant difference between ECR thresholds and audiometry across frequency, 16.5 dBHL on average by age, and 14.6 dBHL on average by CI use time (p < 0.05). In contrast, there was an average difference no significant of 4.1 dBHL and 3.1 dBHL when patient age and cochlear implant use time increases, respectively. These results indicate the feasibility to get patient hearing thresholds as soon as CI is activated. Early audiometry estimation by using ECR thresholds allows an opportune therapy decision-making, increasing patient rehabilitation expectations and avoiding audiometry limitations due to patient short age, general health condition and scanty CI use time.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Brown, C.J., Abbas, P.J., Gantz, B.J.: Preliminary experience with neural response telemetry in the nucleus CI24 M cochlear implant. Am J. Otol 19(3), 320–327 (1998) Brown, C.J., Abbas, P.J., Gantz, B.J.: Preliminary experience with neural response telemetry in the nucleus CI24 M cochlear implant. Am J. Otol 19(3), 320–327 (1998)
2.
Zurück zum Zitat Brown, C.J., Hughes, M.L., Luk, B., Abbas, P.J., Wolaver, A., Gervais, J.: The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: data from adults. Ear Hear 21(2), 151–163 (2000)CrossRef Brown, C.J., Hughes, M.L., Luk, B., Abbas, P.J., Wolaver, A., Gervais, J.: The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: data from adults. Ear Hear 21(2), 151–163 (2000)CrossRef
3.
Zurück zum Zitat Franck, K.H.: A model of a nucleus 24 cochlear implant fitting protocol based on the electrically evoked whole nerve action potential. Ear Hear. 23(Issue 1), 67S-71S (2002) Franck, K.H.: A model of a nucleus 24 cochlear implant fitting protocol based on the electrically evoked whole nerve action potential. Ear Hear. 23(Issue 1), 67S-71S (2002)
4.
Zurück zum Zitat Franck, K.H., Norton, S.J.: Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation’s CI24 M device. Ear Hear. 22(4), 289–299 (2001)CrossRef Franck, K.H., Norton, S.J.: Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation’s CI24 M device. Ear Hear. 22(4), 289–299 (2001)CrossRef
5.
Zurück zum Zitat Hughes, M.L., et al.: A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users. Ear Hear. 22, 471–486 (2001) Hughes, M.L., et al.: A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users. Ear Hear. 22, 471–486 (2001)
6.
Zurück zum Zitat Hochmair-Desoyer, I., Schulz, E., Moser, L., Schmidt, M.: The HSM sentence test as a tool for evaluating the speech understanding in noise of cochlear implant users. Am J. Otol 18(6 Suppl), S83 (1997) Hochmair-Desoyer, I., Schulz, E., Moser, L., Schmidt, M.: The HSM sentence test as a tool for evaluating the speech understanding in noise of cochlear implant users. Am J. Otol 18(6 Suppl), S83 (1997)
7.
Zurück zum Zitat Zimmerling, M., Hochmair, E.S.: EAP recordings in ineraid patients - correlations with psychophysical measures and possible implications for patient fitting. Ear Hear. 23, 81–91 (2002)CrossRef Zimmerling, M., Hochmair, E.S.: EAP recordings in ineraid patients - correlations with psychophysical measures and possible implications for patient fitting. Ear Hear. 23, 81–91 (2002)CrossRef
8.
Zurück zum Zitat Skinner, M.W., Holden, L.K., Holden, T.A., Demorest, M.E., Fourakis, M.S.: Speech recognition at simulated soft, conversational, and raised-to-loud vocal efforts by adults with cochlear implants. J. Acoust. Soc. Am. 101, 3766–3782 (1997)CrossRef Skinner, M.W., Holden, L.K., Holden, T.A., Demorest, M.E., Fourakis, M.S.: Speech recognition at simulated soft, conversational, and raised-to-loud vocal efforts by adults with cochlear implants. J. Acoust. Soc. Am. 101, 3766–3782 (1997)CrossRef
9.
Zurück zum Zitat Skinner, M.W., Holden, L.K., Holden, T.A., Demorest, M.E.: Comparison of two methods for selecting minimum stimulation levels used in programming the Nucleus 22 cochlear implant. J. Speech Lang Hear Res. 42, 814–828 (1999)CrossRef Skinner, M.W., Holden, L.K., Holden, T.A., Demorest, M.E.: Comparison of two methods for selecting minimum stimulation levels used in programming the Nucleus 22 cochlear implant. J. Speech Lang Hear Res. 42, 814–828 (1999)CrossRef
10.
Zurück zum Zitat Baudhuin, J., Cadieux, J., Firszt, J.B., Reeder, R.M., Maxson, J.L.: Optimization of programming parameters in children with the advanced bionics cochlear implant. J. Am. Acad. Audiol. J. Am. Acad. Audiol. 5(23), 302–12 (2012) Baudhuin, J., Cadieux, J., Firszt, J.B., Reeder, R.M., Maxson, J.L.: Optimization of programming parameters in children with the advanced bionics cochlear implant. J. Am. Acad. Audiol. J. Am. Acad. Audiol. 5(23), 302–12 (2012)
11.
Zurück zum Zitat Koka, K., Saoji, A.A., Litvak, L.M.: Electrocochleography in cochlear implant recipients with residual hearing: comparison with audiometric thresholds. Ear Hear. 38(3), 161–167 (2017)CrossRef Koka, K., Saoji, A.A., Litvak, L.M.: Electrocochleography in cochlear implant recipients with residual hearing: comparison with audiometric thresholds. Ear Hear. 38(3), 161–167 (2017)CrossRef
12.
Zurück zum Zitat Coulthurst, S., Nachman, A.J., Murray, M.T., Koka, K., Saoji, A.A.: Comparison of pure-tone thresholds and cochlear microphonics thresholds in pediatric cochlear implant patients. Ear Hear. 41(5), 1320–1326 (2020)CrossRef Coulthurst, S., Nachman, A.J., Murray, M.T., Koka, K., Saoji, A.A.: Comparison of pure-tone thresholds and cochlear microphonics thresholds in pediatric cochlear implant patients. Ear Hear. 41(5), 1320–1326 (2020)CrossRef
13.
Zurück zum Zitat Quintana, A., Beltran, N., Granados, M.P., Chamlati, E., Mena, M., Cornejo, J.M.: Objective approach to audiometry in the pediatric implanted patient. In: Braidot, A., Hadad, A. (eds.) VI Latin American Congress on Biomedical Engineering CLAIB 2014; Paraná, Argentina 29, 30 & 31 October, vol. 49, pp. 707–710. IFMBE Proceedings. Springer, Cham (2016) https://doi.org/10.1007/978-3-319-13117-7_180 Quintana, A., Beltran, N., Granados, M.P., Chamlati, E., Mena, M., Cornejo, J.M.: Objective approach to audiometry in the pediatric implanted patient. In: Braidot, A., Hadad, A. (eds.) VI Latin American Congress on Biomedical Engineering CLAIB 2014; Paraná, Argentina 29, 30 & 31 October, vol. 49, pp. 707–710. IFMBE Proceedings. Springer, Cham (2016) https://​doi.​org/​10.​1007/​978-3-319-13117-7_​180
14.
Zurück zum Zitat Quintana López, A.K., Beltran Vargas, N.E., Granados Trejo, M.P., Cornejo-Cruz, J.M.: Electrical Cochlear response as an objective measure of hearing threshold and hearing performance evaluation in pediatric cochlear implant users. Mexican J. Biomed. Eng. 41(3), 72–86 (2020) Quintana López, A.K., Beltran Vargas, N.E., Granados Trejo, M.P., Cornejo-Cruz, J.M.: Electrical Cochlear response as an objective measure of hearing threshold and hearing performance evaluation in pediatric cochlear implant users. Mexican J. Biomed. Eng. 41(3), 72–86 (2020)
15.
Zurück zum Zitat Cornejo, J.M., Quintana, A.K., Beltran, N.E., Granados, P.: Measuring implanted patient response to tone pips. Biomed. Eng. Online 20, 10 (2021)CrossRef Cornejo, J.M., Quintana, A.K., Beltran, N.E., Granados, P.: Measuring implanted patient response to tone pips. Biomed. Eng. Online 20, 10 (2021)CrossRef
Metadaten
Titel
Implanted Pediatric Patient Early Audiometry
verfasst von
Juan Manuel Cornejo Cruz
Agar Karina Quintana López
Ma. del Pilar Granados Trejo
Copyright-Jahr
2023
DOI
https://doi.org/10.1007/978-3-031-18256-3_17

Neuer Inhalt