Skip to main content

2021 | OriginalPaper | Buchkapitel

Influence of an In-Situ Inspection on the Reliability Analysis of an Ancient Timber Roof

verfasst von : Leonardo G. Rodrigues, Hélder S. Sousa

Erschienen in: 18th International Probabilistic Workshop

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Despite the durability of timber and its efficient performance seen in the built heritage, it has become a common practice, in Portugal, to replace ancient timber roof structures by concrete or steel roof ones. The main reason may be attributed to the difficulty in assessing the real condition of timber structures with respect to its actual level of conservation. In this work a reliability analysis of an ancient timber roof, from a Portuguese neoclassic building of the eighteenth century, is made to evidence the importance of different levels of information taking into account visual and geometric inspections. The impact of posterior knowledge obtained from non-destructive tests is evaluated by comparing the probability of failure and the reliability index on two distinct scenarios. The first scenario considers only prior information for the mechanical properties of timber elements and apparent cross-sections for the structural members. On the other hand, the second scenario considers the results of an in-situ inspection that provides the residual cross-section of the principal members, as well as the updating of the modulus of elasticity and density, based on a Bayesian Updating procedure that takes advantage of the results of a database of non-destructive tests. Latin Hypercube Sampling (LHS) was used in this study to generate a set of structural models, in which each model corresponds to a realization of the assumed random variables. Apart from the mechanical properties, the uncertainties related to permanent, snow and wind loads, are included according to the provisions of the Joint Committee on Structural Safety (JCSS). The presented results indicate that in-situ inspections have to be a priority on the assessment of ancient timber structures. The absence of a careful assessment of deteriorated elements can lead to incorrect conclusions about the structural safety. Additionally, the use of a probabilistic framework allows to a better definition of intervention plans by providing the reliability of distinct critical elements.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Munch-Andersen, J., & Dietsch, P. (2011). Robustness of large-span timber roof structures—Two examples. Engineering Structures. Munch-Andersen, J., & Dietsch, P. (2011). Robustness of large-span timber roof structures—Two examples. Engineering Structures.
2.
Zurück zum Zitat Woodard, A. C., & Milner, H. R. (2016). Sustainability of timber and wood in construction (2nd ed.). Amsterdam: Elsevier Ltd. Woodard, A. C., & Milner, H. R. (2016). Sustainability of timber and wood in construction (2nd ed.). Amsterdam: Elsevier Ltd.
3.
Zurück zum Zitat Cruz, H., et al. (2015). Guidelines for on-site assessment of historic timber structures. International Journal of Architectural Heritage, 9(3). Cruz, H., et al. (2015). Guidelines for on-site assessment of historic timber structures. International Journal of Architectural Heritage, 9(3).
4.
Zurück zum Zitat Riggio, M., et al. (2014). In situ assessment of structural timber using non-destructive techniques. Materials and Structures, 47(5), 749–766.CrossRef Riggio, M., et al. (2014). In situ assessment of structural timber using non-destructive techniques. Materials and Structures, 47(5), 749–766.CrossRef
5.
Zurück zum Zitat Köhler, J. (2006). Reliability of timber structures. Swiss Federal Institute of Technology, no. DISS. ETH NO. 16378. Köhler, J. (2006). Reliability of timber structures. Swiss Federal Institute of Technology, no. DISS. ETH NO. 16378.
6.
Zurück zum Zitat LNEC, NP 4305:1995. (1995). Structural maritime pine swan timber—Visual grading, CT 14. LNEC, NP 4305:1995. (1995). Structural maritime pine swan timber—Visual grading, CT 14.
7.
Zurück zum Zitat Sousa, H. S., & Neves, L. C. (2018). Reliability-based design of interventions in deteriorated timber structures. International Journal of Architectural Heritage, 12(4), 507–515.CrossRef Sousa, H. S., & Neves, L. C. (2018). Reliability-based design of interventions in deteriorated timber structures. International Journal of Architectural Heritage, 12(4), 507–515.CrossRef
8.
Zurück zum Zitat Rodrigues, L. G., Aranha, C. A., & Sousa, H. S. (2016). Robustness assessment of an ancient timber roof structure. In Historical earthquake-resistant timber framing in the mediterranean area (pp. 447–457). Cham: Springer. Rodrigues, L. G., Aranha, C. A., & Sousa, H. S. (2016). Robustness assessment of an ancient timber roof structure. In Historical earthquake-resistant timber framing in the mediterranean area (pp. 447–457). Cham: Springer.
9.
Zurück zum Zitat Branco, J. M., Sousa, H. S., & Tsakanika, E. (2017). Non-destructive assessment, full-scale load-carrying tests and local interventions on two historic timber collar roof trusses. Engineering Structures, 140, 209–224.CrossRef Branco, J. M., Sousa, H. S., & Tsakanika, E. (2017). Non-destructive assessment, full-scale load-carrying tests and local interventions on two historic timber collar roof trusses. Engineering Structures, 140, 209–224.CrossRef
10.
Zurück zum Zitat CEN, EN 1995-1-1:2004. (2004). Eurocode 5: Design of timber structures—Part 1-1: General—Common rules and rules for buildings (vol. 1). CEN, EN 1995-1-1:2004. (2004). Eurocode 5: Design of timber structures—Part 1-1: General—Common rules and rules for buildings (vol. 1).
11.
Zurück zum Zitat Köhler, J., Sørensen, J. D., & Faber, M. H. (2007). Probabilistic modeling of timber structures. Structural Safety, 29(4), 255–267.CrossRef Köhler, J., Sørensen, J. D., & Faber, M. H. (2007). Probabilistic modeling of timber structures. Structural Safety, 29(4), 255–267.CrossRef
12.
Zurück zum Zitat Sousa, H. S., Sørensen, J. D., Kirkegaard, P. H., Branco, J. M., & Lourenço, P. B. (2013). On the use of NDT data for reliability-based assessment of existing timber structures. Engineering Structures, 56, 298–311.CrossRef Sousa, H. S., Sørensen, J. D., Kirkegaard, P. H., Branco, J. M., & Lourenço, P. B. (2013). On the use of NDT data for reliability-based assessment of existing timber structures. Engineering Structures, 56, 298–311.CrossRef
13.
Zurück zum Zitat Gomes, I. D., Kondis, F., Sousa, H. S., Branco, J. M., & Lourenço, P. B. (2016). Assessment and diagnosis of two collar timber trusses by means of visual grading and non-destructive tests. In Historical earthquake-resistant timber framing in the Mediterranean area (pp. 311–320). Berlin: Springer. Gomes, I. D., Kondis, F., Sousa, H. S., Branco, J. M., & Lourenço, P. B. (2016). Assessment and diagnosis of two collar timber trusses by means of visual grading and non-destructive tests. In Historical earthquake-resistant timber framing in the Mediterranean area (pp. 311–320). Berlin: Springer.
14.
Zurück zum Zitat Yurrita, M., & Cabrero, J. M. (2018). New criteria for the determination of the parallel-to-grain embedment strength of wood. Construction and Building Materials, 173, 238–250.CrossRef Yurrita, M., & Cabrero, J. M. (2018). New criteria for the determination of the parallel-to-grain embedment strength of wood. Construction and Building Materials, 173, 238–250.CrossRef
15.
Zurück zum Zitat Steenbergen, R. D. J. M., Sýkora, M., Diamantidis, D., Holický, M., & Vrouwenvelder, T. (2015). Economic and human safety reliability levels for existing structures. Structural Concrete, 16(3), 323–332.CrossRef Steenbergen, R. D. J. M., Sýkora, M., Diamantidis, D., Holický, M., & Vrouwenvelder, T. (2015). Economic and human safety reliability levels for existing structures. Structural Concrete, 16(3), 323–332.CrossRef
Metadaten
Titel
Influence of an In-Situ Inspection on the Reliability Analysis of an Ancient Timber Roof
verfasst von
Leonardo G. Rodrigues
Hélder S. Sousa
Copyright-Jahr
2021
DOI
https://doi.org/10.1007/978-3-030-73616-3_31