Skip to main content

2018 | OriginalPaper | Buchkapitel

Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment

verfasst von : Mario Cifrek

Erschienen in: Inspection of Medical Devices

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The chapter deals with the inspection of neurodiagnostic equipment based on measurement of electrophysiological signals in order to detect eventual problems and prevent them from becoming serious safety risks. In the first section of the text a brief description of the human neuromuscular system is given, followed by description and short historical overview of considered neurodiagnostic methods: electroencephalography (EEG) including evoked potentials (EP), electromyography (EMG) and nerve conduction study (NCS). Operating principle of computer-controlled neurodiagnostic instrument is explained using generic block diagram. The next sections discuss potential harms and hazards associated with the use of neurodiagnostic equipment as well as standards and regulations concerning basic safety and essential performance requirements for mentioned equipment. The last section describes inspection procedure for periodical testing of modern computer-based nerodiagnostic instruments in the field.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Dudek RW, Louis TM (2012) High-yield gross anatomy. Lippincott Williams & Wilkins, Baltimore Dudek RW, Louis TM (2012) High-yield gross anatomy. Lippincott Williams & Wilkins, Baltimore
2.
Zurück zum Zitat Guyton AC, Hall JE (2006) Textbook of medical physiology, Eleventh edn. Elsevier Saunders, Philadelphia Guyton AC, Hall JE (2006) Textbook of medical physiology, Eleventh edn. Elsevier Saunders, Philadelphia
3.
Zurück zum Zitat Mader SS (2011) Human biology, Eleventh edn. McGraw-Hill, New York Mader SS (2011) Human biology, Eleventh edn. McGraw-Hill, New York
4.
Zurück zum Zitat Penfield W, Rasmunssen T (1950) The cerebral cortex of man: a clinical study of localization of function. MacMillan, New York Penfield W, Rasmunssen T (1950) The cerebral cortex of man: a clinical study of localization of function. MacMillan, New York
5.
Zurück zum Zitat Noback CR, Strominger NL, Demarest RJ, Ruggiero DA (2005) The human nervous system: structure and function, 6th edn. Humana Press Inc., Totowa Noback CR, Strominger NL, Demarest RJ, Ruggiero DA (2005) The human nervous system: structure and function, 6th edn. Humana Press Inc., Totowa
6.
Zurück zum Zitat Niedermeyer E, Da Silva FL (eds) (2005) Electroencephalography: basic principles, clinical applications, and related fields, 5th edn. Lippincott Williams & Wilkins, Philadelphia Niedermeyer E, Da Silva FL (eds) (2005) Electroencephalography: basic principles, clinical applications, and related fields, 5th edn. Lippincott Williams & Wilkins, Philadelphia
7.
Zurück zum Zitat Kennett R (2012) Modern electroencephalography. J Neurol 259:783–789CrossRef Kennett R (2012) Modern electroencephalography. J Neurol 259:783–789CrossRef
8.
Zurück zum Zitat Kohden Nihon (2014) Accessories neurology. Nihon Kohden Europe GmBH, Kleinmachnow Kohden Nihon (2014) Accessories neurology. Nihon Kohden Europe GmBH, Kleinmachnow
9.
Zurück zum Zitat Medved V (2001) Measurement of human locomotion. CRC Press, Boca Raton Medved V (2001) Measurement of human locomotion. CRC Press, Boca Raton
10.
Zurück zum Zitat Buchtal F, Clemmesen S (1941) On the differentiation of muscle atrophy by electromyography. Acta Psychiat Kbh 16:143CrossRef Buchtal F, Clemmesen S (1941) On the differentiation of muscle atrophy by electromyography. Acta Psychiat Kbh 16:143CrossRef
11.
Zurück zum Zitat Ladegaard J (2002) Story of electromyography equipment. Muscle Nerve 25(S11):S128–S133CrossRef Ladegaard J (2002) Story of electromyography equipment. Muscle Nerve 25(S11):S128–S133CrossRef
12.
Zurück zum Zitat Stalberg E, Trontelj J (1979) Single fibre electromyography. The Mirvalle Press Limited, Surrey Stalberg E, Trontelj J (1979) Single fibre electromyography. The Mirvalle Press Limited, Surrey
13.
Zurück zum Zitat Basmajian JV, De Luca C (1985) Muscles alive: Their functions revealed by electromyography. Williams & Wilkins, Philadelphia Basmajian JV, De Luca C (1985) Muscles alive: Their functions revealed by electromyography. Williams & Wilkins, Philadelphia
14.
Zurück zum Zitat Medved V, Cifrek M (2011) Kinesiological electromyography. In: Klika V (ed) Biomechanics in applications. InTech, Rijeka Medved V, Cifrek M (2011) Kinesiological electromyography. In: Klika V (ed) Biomechanics in applications. InTech, Rijeka
15.
Zurück zum Zitat Barbero M, Merletti R, Rainoldi A (2012) Atlas of muscle innervation zones—understanding surface electromyography and its applications. Springer, Italia, MilanCrossRef Barbero M, Merletti R, Rainoldi A (2012) Atlas of muscle innervation zones—understanding surface electromyography and its applications. Springer, Italia, MilanCrossRef
16.
Zurück zum Zitat Blumenstein B, Eli MB, Tenenbaum G (2002) Brain and body in sport and exercise biofeedback applications in performance enhancement, 1st edn. Wiley, Sussex Blumenstein B, Eli MB, Tenenbaum G (2002) Brain and body in sport and exercise biofeedback applications in performance enhancement, 1st edn. Wiley, Sussex
17.
Zurück zum Zitat Eichler W (1937) Ueber di Ableitung der Aktionspotentiale vom menschlichen nerven in situ. Zeit Biol 98:182–214 Eichler W (1937) Ueber di Ableitung der Aktionspotentiale vom menschlichen nerven in situ. Zeit Biol 98:182–214
18.
Zurück zum Zitat Dawson GD, Scott JW (1949) The recording of nerve action potentials through the skin in man. J Neurol Neurosurg Psychiat 12:259–267CrossRef Dawson GD, Scott JW (1949) The recording of nerve action potentials through the skin in man. J Neurol Neurosurg Psychiat 12:259–267CrossRef
19.
Zurück zum Zitat Binnie CD, Cooper R, Mauguiere F, Fowler CJ, Prior PF, Osselton JW (1995) Clinical neurophysiology—EMG, nerve conduction and evoked potentials. Butterworth-Heinemann Ltd., Oxford Binnie CD, Cooper R, Mauguiere F, Fowler CJ, Prior PF, Osselton JW (1995) Clinical neurophysiology—EMG, nerve conduction and evoked potentials. Butterworth-Heinemann Ltd., Oxford
20.
Zurück zum Zitat Gilliatt RW, Melville ID, Velate AS, Willison RG (1965) A study of normal nerve action potentials using an averaging technique (barrier grid storage tube). J Neurol Neurosurg Psychiatry 28:191–200CrossRef Gilliatt RW, Melville ID, Velate AS, Willison RG (1965) A study of normal nerve action potentials using an averaging technique (barrier grid storage tube). J Neurol Neurosurg Psychiatry 28:191–200CrossRef
21.
Zurück zum Zitat Weiss L, Silver J, Weiss J (eds) (2004) Easy EMG. A guide to performing nerve conduction studies and electromyography. Butterworth-Heinemann, Oxford Weiss L, Silver J, Weiss J (eds) (2004) Easy EMG. A guide to performing nerve conduction studies and electromyography. Butterworth-Heinemann, Oxford
22.
Zurück zum Zitat IEC 60601-1:2005 + AMD1:2012 CSV. Medical electrical equipment—Part 1: General requirements for basic safety and essential performance, 3.1 edn. International Electrotechnical Commission, Geneva, Switzerland IEC 60601-1:2005 + AMD1:2012 CSV. Medical electrical equipment—Part 1: General requirements for basic safety and essential performance, 3.1 edn. International Electrotechnical Commission, Geneva, Switzerland
23.
Zurück zum Zitat IEC 60601-2-26:2012. Medical electrical equipment—Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs. International Electrotechnical Commission, Geneva, Switzerland IEC 60601-2-26:2012. Medical electrical equipment—Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs. International Electrotechnical Commission, Geneva, Switzerland
24.
Zurück zum Zitat IEC 60601-2-40:2016. Medical electrical equipment—Part 2-40: Particular requirements for the basic safety and essential performance of electromyographs and evoked response equipment. International Electrotechnical Commission, Geneva, Switzerland IEC 60601-2-40:2016. Medical electrical equipment—Part 2-40: Particular requirements for the basic safety and essential performance of electromyographs and evoked response equipment. International Electrotechnical Commission, Geneva, Switzerland
26.
Zurück zum Zitat IEC 60601-1-2:2014. Medical electrical equipment—Part 1-2: General requirements for basic safety and essential performance—collateral standard: electromagnetic disturbances—requirements and tests. International Electrotechnical Commission, Geneva, Switzerland IEC 60601-1-2:2014. Medical electrical equipment—Part 1-2: General requirements for basic safety and essential performance—collateral standard: electromagnetic disturbances—requirements and tests. International Electrotechnical Commission, Geneva, Switzerland
27.
Zurück zum Zitat IEC 60601-2-27:2011. Medical electrical equipment—Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment. International Electrotechnical Commission, Geneva, Switzerland IEC 60601-2-27:2011. Medical electrical equipment—Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment. International Electrotechnical Commission, Geneva, Switzerland
28.
Zurück zum Zitat IEC 60318-1:2009. Electroacoustics—Simulators of human head and ear—Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones. International Electrotechnical Commission, Geneva, Switzerland IEC 60318-1:2009. Electroacoustics—Simulators of human head and ear—Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones. International Electrotechnical Commission, Geneva, Switzerland
29.
Zurück zum Zitat ISO 15004-2:2007. Ophthalmic instruments—fundamental requirements and test methods—Part 2: Light hazard protection. International Organization for Standardization, Geneva, Switzerland ISO 15004-2:2007. Ophthalmic instruments—fundamental requirements and test methods—Part 2: Light hazard protection. International Organization for Standardization, Geneva, Switzerland
30.
Zurück zum Zitat IEC 62353:2014. Medical electrical equipment—recurrent test and test after repair of medical electrical equipment, 1.0 edn. International Electrotechnical Commission, Geneva, Switzerland IEC 62353:2014. Medical electrical equipment—recurrent test and test after repair of medical electrical equipment, 1.0 edn. International Electrotechnical Commission, Geneva, Switzerland
31.
Zurück zum Zitat VIASYS Healthcare, Inc. (2005) Neurodiagnostic instruments service manual For Windows XP-based Endeavor CR, VikingQuest and VikingSelect Systems VIASYS Healthcare, Inc. (2005) Neurodiagnostic instruments service manual For Windows XP-based Endeavor CR, VikingQuest and VikingSelect Systems
Metadaten
Titel
Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment
verfasst von
Mario Cifrek
Copyright-Jahr
2018
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-6650-4_7

Neuer Inhalt