Skip to main content

2016 | OriginalPaper | Buchkapitel

Axial Alignment for Anterior Segment Swept Source Optical Coherence Tomography via Robust Low-Rank Tensor Recovery

verfasst von : Yanwu Xu, Lixin Duan, Huazhu Fu, Xiaoqin Zhang, Damon Wing Kee Wong, Baskaran Mani, Tin Aung, Jiang Liu

Erschienen in: Medical Image Computing and Computer-Assisted Intervention - MICCAI 2016

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

We present a one-step approach based on low-rank tensor recovery for axial alignment in 360-degree anterior chamber optical coherence tomography. Achieving translational alignment and rotation correction of cross-sections simultaneously, this technique obtains a better anterior segment topographical representation and improves quantitative measurement accuracy and reproducibility of disease related parameters. Through its use of global information, the proposed method is more robust compared to using only individual or paired slices, and less sensitive to noise and motion artifacts. In angle closure analysis on 30 patient eyes, the preliminary results indicate that the proposed axial alignment method can not only facilitate manual qualitative analysis with more distinct landmark representation and much less human labor, but also can improve the accuracy of automatic quantitative assessment by 2.9 %, which demonstrates that the proposed approach is promising for a wide range of clinical applications.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Fußnoten
1
As illustrated in Fig. 2, \({\mathcal {A}}_{(1)}\), \({\mathcal {A}}_{(2)}\) and \({\mathcal {A}}_{(3)}\) are obtained by unfolding \({\mathcal {A}}\) along the Z, X and Y axes, respectively.
 
2
To give an example, the inverse operation of the mode-i unfolding on an unfolding matrix \({\mathcal {A}}_{(i)}\) restores the original tensor \({\mathcal {A}}\), i.e., \({\mathcal {A}}={\mathrm {fold}}_i({\mathcal {A}}_{(i)})\).
 
Literatur
1.
Zurück zum Zitat Gora, M., Karnowski, K., Szkulmowski, M., Kaluzny, B.J., Huber, R., Kowalczyk, A., Wojtkowski, M.: Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range. Opt. Express 17(17), 14880–14894 (2009)CrossRef Gora, M., Karnowski, K., Szkulmowski, M., Kaluzny, B.J., Huber, R., Kowalczyk, A., Wojtkowski, M.: Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range. Opt. Express 17(17), 14880–14894 (2009)CrossRef
2.
Zurück zum Zitat Lim, S.H.: Clinical applications of anterior segment optical coherence tomography. J. Ophthalmol. Article ID 605729, 12 (2015) Lim, S.H.: Clinical applications of anterior segment optical coherence tomography. J. Ophthalmol. Article ID 605729, 12 (2015)
3.
Zurück zum Zitat Maslin, J.S., Barkana, Y., Dorairaj, S.K.: Anterior segment imaging in glaucoma: an updated review. Indian J. Ophthalmol. 63(8), 630–640 (2015)CrossRef Maslin, J.S., Barkana, Y., Dorairaj, S.K.: Anterior segment imaging in glaucoma: an updated review. Indian J. Ophthalmol. 63(8), 630–640 (2015)CrossRef
4.
Zurück zum Zitat Sakata, L.M., Lavanya, R., Friedman, D.S., Aung, H.T., Seah, S.K., Foster, P.J., Aung, T.: Assessment of the scleral spur in anterior segment optical coherence tomography images. Arch Ophthalmol. 126(2), 181–185 (2008)CrossRef Sakata, L.M., Lavanya, R., Friedman, D.S., Aung, H.T., Seah, S.K., Foster, P.J., Aung, T.: Assessment of the scleral spur in anterior segment optical coherence tomography images. Arch Ophthalmol. 126(2), 181–185 (2008)CrossRef
5.
Zurück zum Zitat Mishima, K., Tomidokoro, A., Suramethakul, P., Mataki, N., Kurita, N., Mayama, C., Araie, M.: Iridotrabecular contact observed using anterior segment three-dimensional OCT in eyes with a shallow peripheral anterior chamber. Invest. Ophthalmol. Vis. Sci. 54(7), 4628–4635 (2013)CrossRef Mishima, K., Tomidokoro, A., Suramethakul, P., Mataki, N., Kurita, N., Mayama, C., Araie, M.: Iridotrabecular contact observed using anterior segment three-dimensional OCT in eyes with a shallow peripheral anterior chamber. Invest. Ophthalmol. Vis. Sci. 54(7), 4628–4635 (2013)CrossRef
6.
Zurück zum Zitat Li, P., Johnstone, M., Wang, R.K.: Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm. J. Biomed. Opt. 19(4), 046013 (2014)CrossRef Li, P., Johnstone, M., Wang, R.K.: Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm. J. Biomed. Opt. 19(4), 046013 (2014)CrossRef
8.
Zurück zum Zitat Xu, J., Ishikawa, H., Wollstein, G., Kagemann, L., Schuman, J.S.: Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering. IEEE Trans. Med. Image 31(7), 1337–1345 (2012)CrossRef Xu, J., Ishikawa, H., Wollstein, G., Kagemann, L., Schuman, J.S.: Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering. IEEE Trans. Med. Image 31(7), 1337–1345 (2012)CrossRef
9.
Zurück zum Zitat Montuoro, A., Wu, J., Waldstein, S., Gerendas, B., Langs, G., Simader, C., Schmidt-Erfurth, U.: Motion artefact correction in retinal optical coherence tomography using local symmetry. In: Golland, P., Hata, N., Barillot, C., Hornegger, J., Howe, R. (eds.) MICCAI 2014, Part II. LNCS, vol. 8674, pp. 130–137. Springer, Heidelberg (2014)CrossRef Montuoro, A., Wu, J., Waldstein, S., Gerendas, B., Langs, G., Simader, C., Schmidt-Erfurth, U.: Motion artefact correction in retinal optical coherence tomography using local symmetry. In: Golland, P., Hata, N., Barillot, C., Hornegger, J., Howe, R. (eds.) MICCAI 2014, Part II. LNCS, vol. 8674, pp. 130–137. Springer, Heidelberg (2014)CrossRef
10.
Zurück zum Zitat Navarro, R., González, L., Hernández, L.: Optics of the average normal cornea from general and canonical representations of its surface topography. J. Opt. Soc. Am. A. Opt. Image Sci. Vis. 23(2), 219–232 (2006)CrossRef Navarro, R., González, L., Hernández, L.: Optics of the average normal cornea from general and canonical representations of its surface topography. J. Opt. Soc. Am. A. Opt. Image Sci. Vis. 23(2), 219–232 (2006)CrossRef
11.
Zurück zum Zitat Xu, Y., Liu, J., Tan, N.M., Lee, B.H., Wong, D.W.K., Baskaran, M., Perera, S., Aung, T.: Anterior chamber angle classification using multiscale histograms of oriented gradients for glaucoma subtype identification. In: IEEE Engineering in Medicine and Biology Society, pp. 3167–3170 (2012) Xu, Y., Liu, J., Tan, N.M., Lee, B.H., Wong, D.W.K., Baskaran, M., Perera, S., Aung, T.: Anterior chamber angle classification using multiscale histograms of oriented gradients for glaucoma subtype identification. In: IEEE Engineering in Medicine and Biology Society, pp. 3167–3170 (2012)
12.
Zurück zum Zitat Xu, Y., Liu, J., Cheng, J., Lee, B.H., Wong, D.W.K., Baskaran, M., Perera, S., Aung, T.: Automated anterior chamber angle localization and glaucoma type classification in OCT images. In: IEEE Engineering in Medicine and Biology Society, pp. 7380–7383 (2013) Xu, Y., Liu, J., Cheng, J., Lee, B.H., Wong, D.W.K., Baskaran, M., Perera, S., Aung, T.: Automated anterior chamber angle localization and glaucoma type classification in OCT images. In: IEEE Engineering in Medicine and Biology Society, pp. 7380–7383 (2013)
13.
Zurück zum Zitat Liu, J., Musialski, P., Wonka, P., Ye, J.: Tensor completion for estimating missing values in visual data. IEEE Trans. Pattern Anal. Mach. Intell. 35(1), 208–220 (2013)CrossRef Liu, J., Musialski, P., Wonka, P., Ye, J.: Tensor completion for estimating missing values in visual data. IEEE Trans. Pattern Anal. Mach. Intell. 35(1), 208–220 (2013)CrossRef
15.
Zurück zum Zitat Xu, Y., Liu, J., Wong, D.W.K., Baskaran, M., Perera, S., Aung, T.: Similarity-weighted linear reconstruction of anterior chamber angles for glaucoma classification. In: IEEE International Symposium on Biomedical Imaging, pp. 693–697 (2016) Xu, Y., Liu, J., Wong, D.W.K., Baskaran, M., Perera, S., Aung, T.: Similarity-weighted linear reconstruction of anterior chamber angles for glaucoma classification. In: IEEE International Symposium on Biomedical Imaging, pp. 693–697 (2016)
16.
Zurück zum Zitat Peng, Y., Ganesh, A., Wright, J., Ma, Y.: RASL: robust alignment by sparse and low-rank decomposition for linearly correlated images. In: CVPR, pp. 2233–2246 (2013) Peng, Y., Ganesh, A., Wright, J., Ma, Y.: RASL: robust alignment by sparse and low-rank decomposition for linearly correlated images. In: CVPR, pp. 2233–2246 (2013)
17.
Zurück zum Zitat Lin, Z., Chen, M., Wu, L., Ma, Y.: The augmented lagrange multiplier method for exact recovery of corrupted low-rank matrices. UIUC Technical report UILU-ENG-09-2215 (2009) Lin, Z., Chen, M., Wu, L., Ma, Y.: The augmented lagrange multiplier method for exact recovery of corrupted low-rank matrices. UIUC Technical report UILU-ENG-09-2215 (2009)
18.
Zurück zum Zitat Yang, J., Yuan, X.: Linearized augmented lagrangian and alternating direction methods for nuclear norm minimization. Math. Comput. 82(281), 301–329 (2013)MathSciNetCrossRefMATH Yang, J., Yuan, X.: Linearized augmented lagrangian and alternating direction methods for nuclear norm minimization. Math. Comput. 82(281), 301–329 (2013)MathSciNetCrossRefMATH
Metadaten
Titel
Axial Alignment for Anterior Segment Swept Source Optical Coherence Tomography via Robust Low-Rank Tensor Recovery
verfasst von
Yanwu Xu
Lixin Duan
Huazhu Fu
Xiaoqin Zhang
Damon Wing Kee Wong
Baskaran Mani
Tin Aung
Jiang Liu
Copyright-Jahr
2016
DOI
https://doi.org/10.1007/978-3-319-46726-9_51