Skip to main content

2017 | OriginalPaper | Buchkapitel

Rigid Slice-To-Volume Medical Image Registration Through Markov Random Fields

verfasst von : Roque Porchetto, Franco Stramana, Nikos Paragios, Enzo Ferrante

Erschienen in: Medical Computer Vision and Bayesian and Graphical Models for Biomedical Imaging

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Rigid slice-to-volume registration is a challenging task, which finds application in medical imaging problems like image fusion for image guided surgeries and motion correction for volume reconstruction. It is usually formulated as an optimization problem and solved using standard continuous methods. In this paper, we discuss how this task be formulated as a discrete labeling problem on a graph. Inspired by previous works on discrete estimation of linear transformations using Markov Random Fields (MRFs), we model it using a pairwise MRF, where the nodes are associated to the rigid parameters, and the edges encode the relation between the variables. We compare the performance of the proposed method to a continuous formulation optimized using simplex, and we discuss how it can be used to further improve the accuracy of our approach. Promising results are obtained using a monomodal dataset composed of magnetic resonance images (MRI) of a beating heart.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Fußnoten
Literatur
1.
Zurück zum Zitat Bao, P., Warmath, J., Galloway, R., Herline, A.: Ultrasound-to-computer-tomography registration for image-guided laparoscopic liver surgery. Surg. Endosc. 19, 424–429 (2005)CrossRef Bao, P., Warmath, J., Galloway, R., Herline, A.: Ultrasound-to-computer-tomography registration for image-guided laparoscopic liver surgery. Surg. Endosc. 19, 424–429 (2005)CrossRef
2.
Zurück zum Zitat Birkfellner, W., Figl, M., Kettenbach, J., Hummel, J., Homolka, P., Schernthaner, R., Nau, T., Bergmann, H.: Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images. Med. Phys. 34(1), 246 (2007)CrossRef Birkfellner, W., Figl, M., Kettenbach, J., Hummel, J., Homolka, P., Schernthaner, R., Nau, T., Bergmann, H.: Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images. Med. Phys. 34(1), 246 (2007)CrossRef
3.
Zurück zum Zitat Boykov, Y., Kolmogorov, V.: An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision. IEEE TPAMI 26(9), 1124–1137 (2004)CrossRefMATH Boykov, Y., Kolmogorov, V.: An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision. IEEE TPAMI 26(9), 1124–1137 (2004)CrossRefMATH
4.
Zurück zum Zitat Boykov, Y., Veksler, O., Zabih, R.: Fast approximate energy minimization via graph cuts. IEEE Trans. Pattern Anal. Mach. Intell. 23(11), 1222–1239 (2001)CrossRef Boykov, Y., Veksler, O., Zabih, R.: Fast approximate energy minimization via graph cuts. IEEE Trans. Pattern Anal. Mach. Intell. 23(11), 1222–1239 (2001)CrossRef
5.
Zurück zum Zitat Fei, B., Duerk, J.L., Boll, D.T., Lewin, J.S., Wilson, D.L.: Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans. Med. Imaging 22(4), 515–525 (2003)CrossRef Fei, B., Duerk, J.L., Boll, D.T., Lewin, J.S., Wilson, D.L.: Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans. Med. Imaging 22(4), 515–525 (2003)CrossRef
7.
Zurück zum Zitat Ferrante, E., Fecamp, V., Paragios, N.: Slice-to-volume deformable registration: efficient one-shot consensus between plane selection and in-plane deformation. IJCARS 10, 791–800 (2015) Ferrante, E., Fecamp, V., Paragios, N.: Slice-to-volume deformable registration: efficient one-shot consensus between plane selection and in-plane deformation. IJCARS 10, 791–800 (2015)
8.
Zurück zum Zitat Ferrante, Enzo, Paragios, Nikos: Non-rigid 2D-3D medical image registration using markov random fields. In: Mori, Kensaku, Sakuma, Ichiro, Sato, Yoshinobu, Barillot, Christian, Navab, Nassir (eds.) MICCAI 2013. LNCS, vol. 8151, pp. 163–170. Springer, Heidelberg (2013). doi:10.1007/978-3-642-40760-4_21 CrossRef Ferrante, Enzo, Paragios, Nikos: Non-rigid 2D-3D medical image registration using markov random fields. In: Mori, Kensaku, Sakuma, Ichiro, Sato, Yoshinobu, Barillot, Christian, Navab, Nassir (eds.) MICCAI 2013. LNCS, vol. 8151, pp. 163–170. Springer, Heidelberg (2013). doi:10.​1007/​978-3-642-40760-4_​21 CrossRef
10.
Zurück zum Zitat Glocker, B., Sotiras, A.: Deformable medical image registration: setting the state of the art with discrete methods. Annu. Rev. Biomed. Eng. 13, 219–244 (2011)CrossRef Glocker, B., Sotiras, A.: Deformable medical image registration: setting the state of the art with discrete methods. Annu. Rev. Biomed. Eng. 13, 219–244 (2011)CrossRef
11.
Zurück zum Zitat Heinrich, M.P., Jenkinson, M., Brady, M., Schnabel, J.A.: MRF-based deformable registration and ventilation estimation of lung CT. IEEE TMI 32(7), 1239–1248 (2013) Heinrich, M.P., Jenkinson, M., Brady, M., Schnabel, J.A.: MRF-based deformable registration and ventilation estimation of lung CT. IEEE TMI 32(7), 1239–1248 (2013)
12.
Zurück zum Zitat Huang, X., Moore, J., Guiraudon, G., Jones, D.L., Bainbridge, D., Ren, J., Peters, T.M.: Dynamic 2D ultrasound and 3D CT image registration of the beating heart. IEEE TMI 28(8), 1179–1189 (2009) Huang, X., Moore, J., Guiraudon, G., Jones, D.L., Bainbridge, D., Ren, J., Peters, T.M.: Dynamic 2D ultrasound and 3D CT image registration of the beating heart. IEEE TMI 28(8), 1179–1189 (2009)
13.
Zurück zum Zitat Kim, B., Boes, J.L., Bland, P.H., Chenevert, T.L., Meyer, C.R.: Motion correction in fMRI via registration of individual slices into an anatomical volume. Magn. Reson. Med. 41(5), 964–972 (1999)CrossRef Kim, B., Boes, J.L., Bland, P.H., Chenevert, T.L., Meyer, C.R.: Motion correction in fMRI via registration of individual slices into an anatomical volume. Magn. Reson. Med. 41(5), 964–972 (1999)CrossRef
14.
Zurück zum Zitat Komodakis, N., Tziritas, G., Paragios, N.: Fast, approximately optimal solutions for single and dynamic MRFs. In: CVPR (2007) Komodakis, N., Tziritas, G., Paragios, N.: Fast, approximately optimal solutions for single and dynamic MRFs. In: CVPR (2007)
16.
Zurück zum Zitat Lempitsky, V., Roth, S., Rother, C.: FusionFlow: discrete-continuous optimization for optical flow estimation. In: CVPR, pp. 1–22 (2008) Lempitsky, V., Roth, S., Rother, C.: FusionFlow: discrete-continuous optimization for optical flow estimation. In: CVPR, pp. 1–22 (2008)
17.
Zurück zum Zitat Liao, R., Zhang, L., Sun, Y., Miao, S., Chefd’Hotel, C.: A review of recent advances in registration techniques applied to minimally invasive therapy. IEEE TMM 15(5), 983–1000 (2013) Liao, R., Zhang, L., Sun, Y., Miao, S., Chefd’Hotel, C.: A review of recent advances in registration techniques applied to minimally invasive therapy. IEEE TMM 15(5), 983–1000 (2013)
20.
Zurück zum Zitat Park, H., Meyer, C.R., Kim, B.: Improved motion correction in fMRI by Joint mapping of slices into an anatomical volume. In: MICCAI, pp. 745–751 (2004) Park, H., Meyer, C.R., Kim, B.: Improved motion correction in fMRI by Joint mapping of slices into an anatomical volume. In: MICCAI, pp. 745–751 (2004)
22.
Zurück zum Zitat Sotiras, A., Davatazikos, C., Paragios, N.: Deformable medical image registration: a survey. IEEE Trans. Med. Imaging 32, 1153–1190 (2013)CrossRef Sotiras, A., Davatazikos, C., Paragios, N.: Deformable medical image registration: a survey. IEEE Trans. Med. Imaging 32, 1153–1190 (2013)CrossRef
23.
Zurück zum Zitat Tadayyon, H., Lasso, A., Kaushal, A., Guion, P., Fichtinger, G.: Target motion tracking in MRI-guided transrectal robotic prostate biopsy. IEEE TBE 58(11), 3135–3142 (2011) Tadayyon, H., Lasso, A., Kaushal, A., Guion, P., Fichtinger, G.: Target motion tracking in MRI-guided transrectal robotic prostate biopsy. IEEE TBE 58(11), 3135–3142 (2011)
25.
Zurück zum Zitat Xu, R., Athavale, P., Nachman, A., Wright, G.A.: Multiscale registration of real-time and prior MRI data for image-guided cardiac interventions. IEEE TBE 61, 2621–2632 (2014) Xu, R., Athavale, P., Nachman, A., Wright, G.A.: Multiscale registration of real-time and prior MRI data for image-guided cardiac interventions. IEEE TBE 61, 2621–2632 (2014)
26.
Zurück zum Zitat Zikic, D., Glocker, B., Kutter, O., Groher, M., Komodakis, N., Khamene, A., Paragios, N., Navab, N.: Markov random field optimization for intensity-based 2D–3D registration. In: SPIE Medical Imaging, p. 762334. International Society for Optics and Photonics (2010) Zikic, D., Glocker, B., Kutter, O., Groher, M., Komodakis, N., Khamene, A., Paragios, N., Navab, N.: Markov random field optimization for intensity-based 2D–3D registration. In: SPIE Medical Imaging, p. 762334. International Society for Optics and Photonics (2010)
27.
Zurück zum Zitat Zikic, D., Glocker, B., Kutter, O., Groher, M., Komodakis, N., Kamen, A., Paragios, N., Navab, N.: Linear intensity-based image registration by Markov random fields and discrete optimization. Med. Image Anal. 14(4), 550–562 (2010)CrossRef Zikic, D., Glocker, B., Kutter, O., Groher, M., Komodakis, N., Kamen, A., Paragios, N., Navab, N.: Linear intensity-based image registration by Markov random fields and discrete optimization. Med. Image Anal. 14(4), 550–562 (2010)CrossRef
Metadaten
Titel
Rigid Slice-To-Volume Medical Image Registration Through Markov Random Fields
verfasst von
Roque Porchetto
Franco Stramana
Nikos Paragios
Enzo Ferrante
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-61188-4_16

Premium Partner