Skip to main content

2017 | Supplement | Buchkapitel

Automatic Near Real-Time Evaluation of 3D Ultrasound Scan Adequacy for Developmental Dysplasia of the Hip

verfasst von : Olivia Paserin, Kishore Mulpuri, Anthony Cooper, Antony J. Hodgson, Rafeef Abugharbieh

Erschienen in: Computer Assisted and Robotic Endoscopy and Clinical Image-Based Procedures

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Accurate detection and diagnosis of developmental dysplasia of the hip (DDH), a common hip instability condition among infants, relies heavily on acquiring adequate ultrasound (US) image data. Although 2D US is the standard modality used for DDH screening, 3D US has recently been considered as well. Presently there is no automatic method (or even a standardized manual method) capable of analyzing the US volume to determine whether that volume is adequate for extracting DDH metrics required for diagnosis. Scan adequacy in 2D has seen only one work on automation and there has been no work done on scan adequacy in 3D. We propose an automatic, near real-time method of assessing 3D ultrasound scans in developmental dysplasia screening and diagnostic applications using a convolutional neural network (CNN). Our classifier labels volumes as adequate or inadequate for subsequent interpretation based on the presence of hip anatomy needed for DDH diagnosis. We validate our approach on 40 datasets from 15 pediatric patients and demonstrate a classification rate of 100% with average processing time of just above 2 s per US volume. We expect automatic US scan adequacy assessment to have significant clinical impact with the potential to help in imaging standardization, improving efficiency of measuring DDH metrics, and improving accuracy of clinical decision making.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Atweh, L., Kan, J.: Multimodality imaging of developmental dysplasia of the hip. Pediatr. Radiol. 43(1), 166–171 (2013)CrossRef Atweh, L., Kan, J.: Multimodality imaging of developmental dysplasia of the hip. Pediatr. Radiol. 43(1), 166–171 (2013)CrossRef
2.
Zurück zum Zitat Graf, R., Mohajer, M., Florian, P.: Hip sonography update: quality-management, catastrophes - tips and tricks. Med. Ultrason. 15(4), 299–303 (2013)CrossRef Graf, R., Mohajer, M., Florian, P.: Hip sonography update: quality-management, catastrophes - tips and tricks. Med. Ultrason. 15(4), 299–303 (2013)CrossRef
3.
Zurück zum Zitat Tschauner, C., Matthissen, H.: Hip sonography with graf-method in newborns: checklists help to avoid mistakes. OUB J. 1, 7–8 (2012) Tschauner, C., Matthissen, H.: Hip sonography with graf-method in newborns: checklists help to avoid mistakes. OUB J. 1, 7–8 (2012)
4.
Zurück zum Zitat Maraci, M., Bridge, C., Napolitano, R., Papageorghiou, A., Noble, A.: A framework for analysis of linear ultrasound videos to detect fetal presentation and heartbeat. Med. Image Anal. 37, 22–36 (2017)CrossRef Maraci, M., Bridge, C., Napolitano, R., Papageorghiou, A., Noble, A.: A framework for analysis of linear ultrasound videos to detect fetal presentation and heartbeat. Med. Image Anal. 37, 22–36 (2017)CrossRef
5.
Zurück zum Zitat Rahmatullah, B., Papageorghiou, A., Noble, J.A.: Automated selection of standardized planes from ultrasound volume. In: Suzuki, K., Wang, F., Shen, D., Yan, P. (eds.) MLMI 2011. LNCS, vol. 7009, pp. 35–42. Springer, Heidelberg (2011). doi:10.1007/978-3-642-24319-6_5 CrossRef Rahmatullah, B., Papageorghiou, A., Noble, J.A.: Automated selection of standardized planes from ultrasound volume. In: Suzuki, K., Wang, F., Shen, D., Yan, P. (eds.) MLMI 2011. LNCS, vol. 7009, pp. 35–42. Springer, Heidelberg (2011). doi:10.​1007/​978-3-642-24319-6_​5 CrossRef
6.
Zurück zum Zitat Baumgartner, C.F., Kamnitsas, K., Matthew, J., Smith, S., Kainz, B., Rueckert, D.: Real-time standard scan plane detection and localisation in fetal ultrasound using fully convolutional neural networks. In: Ourselin, S., Joskowicz, L., Sabuncu, M.R., Unal, G., Wells, W. (eds.) MICCAI 2016. LNCS, vol. 9901, pp. 203–211. Springer, Cham (2016). doi:10.1007/978-3-319-46723-8_24 CrossRef Baumgartner, C.F., Kamnitsas, K., Matthew, J., Smith, S., Kainz, B., Rueckert, D.: Real-time standard scan plane detection and localisation in fetal ultrasound using fully convolutional neural networks. In: Ourselin, S., Joskowicz, L., Sabuncu, M.R., Unal, G., Wells, W. (eds.) MICCAI 2016. LNCS, vol. 9901, pp. 203–211. Springer, Cham (2016). doi:10.​1007/​978-3-319-46723-8_​24 CrossRef
7.
Zurück zum Zitat Quader, N., Hodgson, A., Mulpuri, K., Savage, T., Abugharbieh, A.: Automatic assessment of developmental dysplasia of the hip. In: IEEE 12th International Symposium on Biomedical Imaging (ISBI), pp. 13–16 (2015) Quader, N., Hodgson, A., Mulpuri, K., Savage, T., Abugharbieh, A.: Automatic assessment of developmental dysplasia of the hip. In: IEEE 12th International Symposium on Biomedical Imaging (ISBI), pp. 13–16 (2015)
8.
Zurück zum Zitat Quader, N., Schaeffer, E., Mulpuri, K., Cooper, A., Hodgson, A., Abugharbieh, R.: Automatic evaluation of scan adequacy and dysplasia metrics in 2D ultrasound images of the neonatal hip. Bone Joint J. 98–B(sup. 21), 42 (2016) Quader, N., Schaeffer, E., Mulpuri, K., Cooper, A., Hodgson, A., Abugharbieh, R.: Automatic evaluation of scan adequacy and dysplasia metrics in 2D ultrasound images of the neonatal hip. Bone Joint J. 98–B(sup. 21), 42 (2016)
9.
Zurück zum Zitat Quader, N., Hodgson, A., Mulpuri, K., Schaeffer, E., Abugharbieh, R.: Automatic evaluation of scan adequacy and dysplasia metrics in 2-D ultrasound images of the neonatal hip. Ultras. Med. Biol. 43(6), 1252–1262 (2017)CrossRef Quader, N., Hodgson, A., Mulpuri, K., Schaeffer, E., Abugharbieh, R.: Automatic evaluation of scan adequacy and dysplasia metrics in 2-D ultrasound images of the neonatal hip. Ultras. Med. Biol. 43(6), 1252–1262 (2017)CrossRef
10.
Zurück zum Zitat Jaremko, J., Mabee, M., Swami, V., Jamieson, L., Chow, K., Thompson, R.: Potential for change in US diagnosis of hip dysplasia solely caused by changes in probe orientation: patterns of alpha-angle variation revealed by using three-dimensional US. Radiology 273(3), 870–878 (2014)CrossRef Jaremko, J., Mabee, M., Swami, V., Jamieson, L., Chow, K., Thompson, R.: Potential for change in US diagnosis of hip dysplasia solely caused by changes in probe orientation: patterns of alpha-angle variation revealed by using three-dimensional US. Radiology 273(3), 870–878 (2014)CrossRef
11.
Zurück zum Zitat Mabee, M., Hareendranathan, A., Thompson, R., Dulai, S., Jaremko, J.: An index for diagnosing infant hip dysplasia using 3-D ultrasound: the acetabular contact angle. Pediatr. Radiol. 46(7), 1023–1031 (2016)CrossRef Mabee, M., Hareendranathan, A., Thompson, R., Dulai, S., Jaremko, J.: An index for diagnosing infant hip dysplasia using 3-D ultrasound: the acetabular contact angle. Pediatr. Radiol. 46(7), 1023–1031 (2016)CrossRef
12.
Zurück zum Zitat Hareendranathan, A., Mabee, M., Punithakumar, K., Noga, M., Jaremko, J.: A technique for semiautomatic segmentation of echogenic structures in 3D ultrasound, applied to infant hip dysplasia. Int. J. Comput. Assist. Radiol. Surg. 11(1), 31–42 (2015)CrossRef Hareendranathan, A., Mabee, M., Punithakumar, K., Noga, M., Jaremko, J.: A technique for semiautomatic segmentation of echogenic structures in 3D ultrasound, applied to infant hip dysplasia. Int. J. Comput. Assist. Radiol. Surg. 11(1), 31–42 (2015)CrossRef
13.
Zurück zum Zitat Quader, N., Hodgson, A., Mulpuri, K., Cooper, A., Abugharbieh, R.: Towards reliable automatic characterization of neonatal hip dysplasia from 3D ultrasound images. In: Ourselin, S., Joskowicz, L., Sabuncu, M.R., Unal, G., Wells, W. (eds.) MICCAI 2016. LNCS, vol. 9900, pp. 602–609. Springer, Cham (2016). doi:10.1007/978-3-319-46720-7_70 CrossRef Quader, N., Hodgson, A., Mulpuri, K., Cooper, A., Abugharbieh, R.: Towards reliable automatic characterization of neonatal hip dysplasia from 3D ultrasound images. In: Ourselin, S., Joskowicz, L., Sabuncu, M.R., Unal, G., Wells, W. (eds.) MICCAI 2016. LNCS, vol. 9900, pp. 602–609. Springer, Cham (2016). doi:10.​1007/​978-3-319-46720-7_​70 CrossRef
14.
Zurück zum Zitat Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., Darrell, T.: Caffe: convolutional architecture for fast feature embedding. In: 22nd ACM International Conference on Multimedia, pp. 675–678 (2014) Jia, Y., Shelhamer, E., Donahue, J., Karayev, S., Long, J., Girshick, R., Guadarrama, S., Darrell, T.: Caffe: convolutional architecture for fast feature embedding. In: 22nd ACM International Conference on Multimedia, pp. 675–678 (2014)
15.
Zurück zum Zitat Krizhevski, A., Sutskever, I., Hinton, G.: ImageNet classification with deep convolutional neural networks. In: Neural Information Processing Systems, pp. 1097–1105 (2012) Krizhevski, A., Sutskever, I., Hinton, G.: ImageNet classification with deep convolutional neural networks. In: Neural Information Processing Systems, pp. 1097–1105 (2012)
16.
Zurück zum Zitat Su, Y., Wang, X., Tang, X.: Deep learning face representation from predicting 10,000 classes. In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, pp. 1891–1898 (2014) Su, Y., Wang, X., Tang, X.: Deep learning face representation from predicting 10,000 classes. In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, pp. 1891–1898 (2014)
17.
Zurück zum Zitat Kingma, D., Ba, J.: Adam: A Method for Stochastic Optimization. Proceedings of the 3rd International Conference on Learning Representations. arXiv preprint arXiv:1412.6980 (2015) Kingma, D., Ba, J.: Adam: A Method for Stochastic Optimization. Proceedings of the 3rd International Conference on Learning Representations. arXiv preprint arXiv:​1412.​6980 (2015)
Metadaten
Titel
Automatic Near Real-Time Evaluation of 3D Ultrasound Scan Adequacy for Developmental Dysplasia of the Hip
verfasst von
Olivia Paserin
Kishore Mulpuri
Anthony Cooper
Antony J. Hodgson
Rafeef Abugharbieh
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-67543-5_12

Premium Partner