Skip to main content
Erschienen in: Fire Technology 5/2016

01.09.2016

Full-Scale Experiments of Fire Control and Suppression in Enclosed Car Parks: A Comparison Between Sprinkler and Water-Mist Systems

verfasst von: Paolo E. Santangelo, Luca Tarozzi, Paolo Tartarini

Erschienen in: Fire Technology | Ausgabe 5/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Recent efforts to investigate car-park fires and understand the related mechanisms have fostered the need for analyses of suppression performance against this type of fire scenario. This work aims at providing an insight into the ability of sprinklers and water-mist systems to control and extinguish a fire within an enclosed car park through a series of real-scale experiments. Three cars were employed in each test: the central one was ignited by a heptane pool fire and the adjacent ones served as targets. Two configurations were explored: in the first one, a nozzle was placed directly at the vertical axis of the ignition source, whereas the ignition source was located between the area coverage of four nozzles in the second one. The sprinkler system mainly served as a reference; two values of discharge density were evaluated for water mist at high operative pressure and a biodegradable surfactant was also tested against the most challenging configuration. A quantitative analysis of free-burn and discharge phases by temperature measurements was coupled with radiant heat-flux measurements and an assessment of post-fire damage. Sprinkler and water-mist systems were capable of containing the fire spread and thermally controlling the fire, thus preventing structural damage. The water mist’s ability to overpower the plume and reach the burning surfaces proved more effective than that of sprinklers, especially as no nozzles were located right above the ignition surface. The higher discharge density showed better capability of preventing re-ignition phenomena and suppression was attained in both the investigated configurations, which suggests that a certain amount of flux is also needed to achieve flame cooling. The additive had promising impact on suppression performance; however, more tests are required to specifically explore its ability to enhance thermal control.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Fußnoten
1
In the present work, “glasses” refers to windows (i.e., windshield, side and rear windows) and does not include any other parts (e.g., headlamps, wing and rear-view mirrors). The vehicles employed in this study did not feature glass-panel roofs.
 
Literatur
1.
Zurück zum Zitat Hill J (2005) Car park designers’ handbook. Thomas Telford Publishing, LondonCrossRef Hill J (2005) Car park designers’ handbook. Thomas Telford Publishing, LondonCrossRef
2.
Zurück zum Zitat Shipp M, Fraser-Mitchell J, Chitty R, Cullinan R, Crowder D, Clark P (2009) Fire spread in car parks. Final research report BD 2552. Building Research Establishment, Watford Shipp M, Fraser-Mitchell J, Chitty R, Cullinan R, Crowder D, Clark P (2009) Fire spread in car parks. Final research report BD 2552. Building Research Establishment, Watford
3.
Zurück zum Zitat Richardson K (2014) Electrical fault caused airport car park blaze. Edinburgh Evening News. Johnston Press, London Richardson K (2014) Electrical fault caused airport car park blaze. Edinburgh Evening News. Johnston Press, London
4.
Zurück zum Zitat Eurofeu Sprinkler Section (2009) Position paper on the fire protection of car parks. Eurofeu Sprinkler Section, Würzburg Eurofeu Sprinkler Section (2009) Position paper on the fire protection of car parks. Eurofeu Sprinkler Section, Würzburg
5.
Zurück zum Zitat Merci B (2013) Special issue fire safety journal on car park fire safety: preface. Fire Saf J 57:2CrossRef Merci B (2013) Special issue fire safety journal on car park fire safety: preface. Fire Saf J 57:2CrossRef
6.
Zurück zum Zitat Chow WK, Fung WY (1995) Survey on the indoor environment of enclosed car parks in Hong Kong. Tunn Undergr Space Technol 10:247–255CrossRef Chow WK, Fung WY (1995) Survey on the indoor environment of enclosed car parks in Hong Kong. Tunn Undergr Space Technol 10:247–255CrossRef
7.
Zurück zum Zitat Chow WK (1996) Simulation of carbon monoxide level in enclosed car parks using an air flow network program. Tunn Undergr Space Technol 11:237–240CrossRef Chow WK (1996) Simulation of carbon monoxide level in enclosed car parks using an air flow network program. Tunn Undergr Space Technol 11:237–240CrossRef
8.
Zurück zum Zitat Chow WK, Wong LT, Fung WY (1996) Field study on the indoor thermal environment and carbon monoxide levels in a large underground car park. Tunn Undergr Space Technol 11:333–343CrossRef Chow WK, Wong LT, Fung WY (1996) Field study on the indoor thermal environment and carbon monoxide levels in a large underground car park. Tunn Undergr Space Technol 11:333–343CrossRef
9.
Zurück zum Zitat Chan MY, Burnett J, Chow WK (1998) Energy use for ventilation systems in underground car parks. Build Environ 33:303–314CrossRef Chan MY, Burnett J, Chow WK (1998) Energy use for ventilation systems in underground car parks. Build Environ 33:303–314CrossRef
10.
Zurück zum Zitat Chow WK (1998) On safety systems for underground car parks. Tunn Undergr Space Technol 13:281–287CrossRef Chow WK (1998) On safety systems for underground car parks. Tunn Undergr Space Technol 13:281–287CrossRef
11.
Zurück zum Zitat Viegas JC (2010) The use of impulse ventilation for smoke control in underground car parks. Tunn Undergr Space Technol 25:42–53CrossRef Viegas JC (2010) The use of impulse ventilation for smoke control in underground car parks. Tunn Undergr Space Technol 25:42–53CrossRef
12.
Zurück zum Zitat Zhang XG, Guo YC, Chan CK, Lin WY (2007) Numerical simulations on fire spread and smoke movement in an underground car park. Build Environ 42:3466–3475CrossRef Zhang XG, Guo YC, Chan CK, Lin WY (2007) Numerical simulations on fire spread and smoke movement in an underground car park. Build Environ 42:3466–3475CrossRef
13.
Zurück zum Zitat Lin Z, Chow TT, Tsang CF, Fong KF, Chan LS, Shum WS (2008) Effect of ventilation system on smoke and fire spread in a public transport interchange. Fire Technol 44:463–479CrossRef Lin Z, Chow TT, Tsang CF, Fong KF, Chan LS, Shum WS (2008) Effect of ventilation system on smoke and fire spread in a public transport interchange. Fire Technol 44:463–479CrossRef
14.
Zurück zum Zitat Joyeux D (1997) Natural fires in closed car parks—Car fire tests. CTICM Report no. INC-96/294d-DJ/NB. Centre Technique Industriel Construction Métallique, Maizières-les-Metz Joyeux D (1997) Natural fires in closed car parks—Car fire tests. CTICM Report no. INC-96/294d-DJ/NB. Centre Technique Industriel Construction Métallique, Maizières-les-Metz
15.
Zurück zum Zitat Schleich JB, Cajot L-G, Pierre M, Brasseur M, Franssen J-M, Kruppa J, Joyeux D, Twilt L, Van Oerle J, Aurtenetxe G (1999) Development of design rules for steel structures subjected to natural fires in closed car parks. Report EUR 18867. European Coal and Steel Community, Brussels Schleich JB, Cajot L-G, Pierre M, Brasseur M, Franssen J-M, Kruppa J, Joyeux D, Twilt L, Van Oerle J, Aurtenetxe G (1999) Development of design rules for steel structures subjected to natural fires in closed car parks. Report EUR 18867. European Coal and Steel Community, Brussels
16.
Zurück zum Zitat Zhao B, Kruppa J (2004) Structural behaviour of an open car park under real fire scenarios. Fire Mater 28:269–280CrossRef Zhao B, Kruppa J (2004) Structural behaviour of an open car park under real fire scenarios. Fire Mater 28:269–280CrossRef
17.
Zurück zum Zitat Tilley N, Deckers X, Merci B (2012) CFD study of relation between ventilation velocity and smoke backlayering distance in large closed car parks. Fire Saf J 48:11–20CrossRef Tilley N, Deckers X, Merci B (2012) CFD study of relation between ventilation velocity and smoke backlayering distance in large closed car parks. Fire Saf J 48:11–20CrossRef
18.
Zurück zum Zitat Horváth I, van Beeck J, Merci B (2013) Full-scale and reduced-scale tests on smoke movement in case of car park fire. Fire Saf J 57:35–43CrossRef Horváth I, van Beeck J, Merci B (2013) Full-scale and reduced-scale tests on smoke movement in case of car park fire. Fire Saf J 57:35–43CrossRef
19.
Zurück zum Zitat Deckers X, Haga S, Sette B, Merci B (2013) Smoke control in case of fire in a large car park: Full-scale experiments. Fire Saf J 57:11–21CrossRef Deckers X, Haga S, Sette B, Merci B (2013) Smoke control in case of fire in a large car park: Full-scale experiments. Fire Saf J 57:11–21CrossRef
20.
Zurück zum Zitat Deckers X, Haga S, Tilley N, Merci B (2013) Smoke control in case of fire in a large car park: CFD simulations of full-scale configurations. Fire Saf J 57:22–34CrossRef Deckers X, Haga S, Tilley N, Merci B (2013) Smoke control in case of fire in a large car park: CFD simulations of full-scale configurations. Fire Saf J 57:22–34CrossRef
21.
Zurück zum Zitat Fang C, Izzuddin BA, Obiala R, Elghazouli AY, Nethercot DA (2012) Robustness of multi-storey car parks under vehicle fire. J Constr Steel Res 75:72–84CrossRef Fang C, Izzuddin BA, Obiala R, Elghazouli AY, Nethercot DA (2012) Robustness of multi-storey car parks under vehicle fire. J Constr Steel Res 75:72–84CrossRef
22.
Zurück zum Zitat Fang C, Izzuddin BA, Elghazouli AY, Nethercot DA (2013) Robustness of multi-storey car parks under localized fire—Towards practical design recommendations. J Constr Steel Res 90:193–208CrossRef Fang C, Izzuddin BA, Elghazouli AY, Nethercot DA (2013) Robustness of multi-storey car parks under localized fire—Towards practical design recommendations. J Constr Steel Res 90:193–208CrossRef
23.
Zurück zum Zitat Fang C, Izzuddin BA, Elghazouli AY, Nethercot DA (2013) Simplified energy-based robustness assessment for steel-composite car parks under vehicle fire. Eng Struct 49:719–732CrossRef Fang C, Izzuddin BA, Elghazouli AY, Nethercot DA (2013) Simplified energy-based robustness assessment for steel-composite car parks under vehicle fire. Eng Struct 49:719–732CrossRef
24.
Zurück zum Zitat Annerel E, Taerwe L, Merci B, Jansen D, Bamonte P, Felicetti R (2013) Thermo-mechanical analysis of an underground car park structure exposed to fire. Fire Saf J 57:96–106.CrossRef Annerel E, Taerwe L, Merci B, Jansen D, Bamonte P, Felicetti R (2013) Thermo-mechanical analysis of an underground car park structure exposed to fire. Fire Saf J 57:96–106.CrossRef
25.
Zurück zum Zitat van der Heijden MGM, Loomans MGLC, Lemaire AD, Hensen JLM (2013) Fire safety assessment of semi-open car parks based on validated CFD simulations. Build Simul 6:385–394CrossRef van der Heijden MGM, Loomans MGLC, Lemaire AD, Hensen JLM (2013) Fire safety assessment of semi-open car parks based on validated CFD simulations. Build Simul 6:385–394CrossRef
26.
Zurück zum Zitat Van den Schoor F, Middha P, Van den Bulck E (2013) Risk analysis of LPG (liquefied petroleum gas) vehicles in enclosed car parks. Fire Saf J 57:58–68CrossRef Van den Schoor F, Middha P, Van den Bulck E (2013) Risk analysis of LPG (liquefied petroleum gas) vehicles in enclosed car parks. Fire Saf J 57:58–68CrossRef
27.
Zurück zum Zitat Merci B, Shipp M (2013) Smoke and heat control for fires in large car parks: Lessons learnt from research? Fire Saf J 57:3–10CrossRef Merci B, Shipp M (2013) Smoke and heat control for fires in large car parks: Lessons learnt from research? Fire Saf J 57:3–10CrossRef
28.
Zurück zum Zitat VdS (2015) Wassernebel-Sprinkleranlagen und Wassernebel-Löschanlagen (Hochdruck-Systeme), Planung und Einbau (Water mist-sprinkler systems and water-mist extinguishing systems—High-pressure systems, Planning and installation). VdS 3188. VdS Schadenverhütung, Cologne VdS (2015) Wassernebel-Sprinkleranlagen und Wassernebel-Löschanlagen (Hochdruck-Systeme), Planung und Einbau (Water mist-sprinkler systems and water-mist extinguishing systems—High-pressure systems, Planning and installation). VdS 3188. VdS Schadenverhütung, Cologne
29.
Zurück zum Zitat European Committee for Standardization (2009) Fixed firefighting systems—Automatic sprinkler systems—Design, installation and maintenance. EN 12845:2004 + A2:2009. CEN-CENELEC, Brussels European Committee for Standardization (2009) Fixed firefighting systems—Automatic sprinkler systems—Design, installation and maintenance. EN 12845:2004 + A2:2009. CEN-CENELEC, Brussels
30.
Zurück zum Zitat Mangs J, Keski-Rahkonen O (1994) Characterization of the fire behaviour of a burning passenger car. Part I: Car Fire Experiments. Fire Saf J 23:17–35CrossRef Mangs J, Keski-Rahkonen O (1994) Characterization of the fire behaviour of a burning passenger car. Part I: Car Fire Experiments. Fire Saf J 23:17–35CrossRef
31.
Zurück zum Zitat Tohir MZM, Spearpoint M (2013) Distribution analysis of the fire severity characteristics of single passenger road vehicles using heat release rate data. Fire Sci Rev 2:5CrossRef Tohir MZM, Spearpoint M (2013) Distribution analysis of the fire severity characteristics of single passenger road vehicles using heat release rate data. Fire Sci Rev 2:5CrossRef
32.
Zurück zum Zitat Spearpoint MJ, Mohd Tohir MZ, Abu AK, Xie P (2015) Fire load energy densities for risk-based design of car parking buildings. Case Stud Fire Saf 3:44–50CrossRef Spearpoint MJ, Mohd Tohir MZ, Abu AK, Xie P (2015) Fire load energy densities for risk-based design of car parking buildings. Case Stud Fire Saf 3:44–50CrossRef
33.
Zurück zum Zitat Ren N, Blum A, Do C, Marshall AW (2009) Atomization and dispersion measurements in fire sprinkler sprays. Atom Sprays 19:1125–1136CrossRef Ren N, Blum A, Do C, Marshall AW (2009) Atomization and dispersion measurements in fire sprinkler sprays. Atom Sprays 19:1125–1136CrossRef
34.
Zurück zum Zitat Santangelo PE (2010) Characterization of high-pressure water-mist sprays: Experimental analysis of droplet size and dispersion. Exp Therm Fluid Sci 34:1353–1366CrossRef Santangelo PE (2010) Characterization of high-pressure water-mist sprays: Experimental analysis of droplet size and dispersion. Exp Therm Fluid Sci 34:1353–1366CrossRef
35.
Zurück zum Zitat [35] Santangelo PE (2012) Experiments and modeling of discharge characteristics in water-mist sprays generated by pressure-swirl atomizers. J Therm Sci 21:539–548CrossRef [35] Santangelo PE (2012) Experiments and modeling of discharge characteristics in water-mist sprays generated by pressure-swirl atomizers. J Therm Sci 21:539–548CrossRef
36.
Zurück zum Zitat Santangelo PE, Tartarini P, Valdiserri P (2011) Experimental parametric analysis of water-mist sprays: An investigation on coalescence and initial dispersion. In: Proceedings of ASME 2011 international mechanical engineering congress and exposition (IMECE 2011), vol 6. Denver, CO, pp 1167–1174 Santangelo PE, Tartarini P, Valdiserri P (2011) Experimental parametric analysis of water-mist sprays: An investigation on coalescence and initial dispersion. In: Proceedings of ASME 2011 international mechanical engineering congress and exposition (IMECE 2011), vol 6. Denver, CO, pp 1167–1174
37.
Zurück zum Zitat Heskestad G (1972) Proposal for studying interaction of water sprays with plume in sprinkler optimization program. FMRC Interoffice Correspondence. FM Global, Norwood Heskestad G (1972) Proposal for studying interaction of water sprays with plume in sprinkler optimization program. FMRC Interoffice Correspondence. FM Global, Norwood
38.
Zurück zum Zitat Lefebvre AH (1989) Atomization and sprays. Hemisphere, Washington Lefebvre AH (1989) Atomization and sprays. Hemisphere, Washington
39.
Zurück zum Zitat Lawson JR, Walton WD, Evans DD (1988) Measurement of droplet size in sprinkler sprays. NBSIR 88-3715. National Bureau of Standards, Gaithersburg Lawson JR, Walton WD, Evans DD (1988) Measurement of droplet size in sprinkler sprays. NBSIR 88-3715. National Bureau of Standards, Gaithersburg
40.
Zurück zum Zitat Santangelo PE, Tartarini P, Pulvirenti B, Valdiserri P, Marshall AW (2010) Fire suppression by water-mist sprays: experimental and numerical analysis. In: Proceedings of 14th international heat transfer conference (IHTC-14), vol 5. Washington, pp 571–580 Santangelo PE, Tartarini P, Pulvirenti B, Valdiserri P, Marshall AW (2010) Fire suppression by water-mist sprays: experimental and numerical analysis. In: Proceedings of 14th international heat transfer conference (IHTC-14), vol 5. Washington, pp 571–580
41.
Zurück zum Zitat Santangelo PE, Tartarini P (2012) Full-scale experiments of fire suppression in high-hazard storages: A temperature-based analysis of water-mist systems. Appl Therm Eng 45–46:99–107CrossRef Santangelo PE, Tartarini P (2012) Full-scale experiments of fire suppression in high-hazard storages: A temperature-based analysis of water-mist systems. Appl Therm Eng 45–46:99–107CrossRef
42.
Zurück zum Zitat Giffen E, Muraszew A (1953) Atomization of liquid fuels. Chapman & Hall, London Giffen E, Muraszew A (1953) Atomization of liquid fuels. Chapman & Hall, London
43.
Zurück zum Zitat Rizk NK, Lefebvre AH (1985) Internal flow characteristics of simplex swirl atomizers. J Propul Power 1:193–199CrossRef Rizk NK, Lefebvre AH (1985) Internal flow characteristics of simplex swirl atomizers. J Propul Power 1:193–199CrossRef
44.
Zurück zum Zitat Scheffey JL, Forssell EW, Childs JT (2013) Evaluation of water additives for fire control and vapor mitigation. Phase I Final Report. The Fire Protection Research Foundation, Quincy Scheffey JL, Forssell EW, Childs JT (2013) Evaluation of water additives for fire control and vapor mitigation. Phase I Final Report. The Fire Protection Research Foundation, Quincy
45.
Zurück zum Zitat Stroup DW, Madrzykowski D, Bishop MJ (1998) Chapter 2: Fire fighting properties. In: Madrzykowski D, Stroup DW (eds) Demonstration of biodegradable, environmentally safe, non-toxic fire suppression liquids. NISTIR 6191. National Institute of Standards and Technology, Gaithersburg Stroup DW, Madrzykowski D, Bishop MJ (1998) Chapter 2: Fire fighting properties. In: Madrzykowski D, Stroup DW (eds) Demonstration of biodegradable, environmentally safe, non-toxic fire suppression liquids. NISTIR 6191. National Institute of Standards and Technology, Gaithersburg
46.
Zurück zum Zitat National Fire Protection Association (2015) NFPA 750 Standard on water mist fire protection systems. NFPA, Quincy National Fire Protection Association (2015) NFPA 750 Standard on water mist fire protection systems. NFPA, Quincy
47.
Zurück zum Zitat Ingason H, Wickström U (2007) Measuring incident radiant heat flux using the plate thermometer. Fire Saf J 42:161–166CrossRef Ingason H, Wickström U (2007) Measuring incident radiant heat flux using the plate thermometer. Fire Saf J 42:161–166CrossRef
48.
Zurück zum Zitat Haremza C, Santiago A, Simões da Silva L (2013) Design of steel and composite open car parks. Adv Steel Constr 9:350–368 Haremza C, Santiago A, Simões da Silva L (2013) Design of steel and composite open car parks. Adv Steel Constr 9:350–368
49.
Zurück zum Zitat Yule HP (1969) Computation of experimental results in activation analysis. In: DeVoe JR, LaFleur PD (eds) Modern trends in activation analysis, vol 2. National Bureau of Standards, Washington, pp 1155–1204 Yule HP (1969) Computation of experimental results in activation analysis. In: DeVoe JR, LaFleur PD (eds) Modern trends in activation analysis, vol 2. National Bureau of Standards, Washington, pp 1155–1204
50.
Zurück zum Zitat Orlandini S, Moretti G, Corticelli MA, Santangelo PE, Capra A, Rivola R, Albertson JD (2012) Evaluation of flow direction methods against field observations of overland flow dispersion. Water Resour Res 48:W10523CrossRef Orlandini S, Moretti G, Corticelli MA, Santangelo PE, Capra A, Rivola R, Albertson JD (2012) Evaluation of flow direction methods against field observations of overland flow dispersion. Water Resour Res 48:W10523CrossRef
51.
Zurück zum Zitat Santangelo PE, Jacobs BC, Ren N, Sheffel JA, Corn ML, Marshall AW (2014) Suppression effectiveness of water-mist sprays on accelerated wood-crib fires. Fire Saf J 70:98–111CrossRef Santangelo PE, Jacobs BC, Ren N, Sheffel JA, Corn ML, Marshall AW (2014) Suppression effectiveness of water-mist sprays on accelerated wood-crib fires. Fire Saf J 70:98–111CrossRef
52.
Zurück zum Zitat Shipp MP, Spearpoint MJ (1995) Measurements of the severity of fires involving private motor vehicles. Fire Mater 19:143–151CrossRef Shipp MP, Spearpoint MJ (1995) Measurements of the severity of fires involving private motor vehicles. Fire Mater 19:143–151CrossRef
53.
Zurück zum Zitat Li Y, Spearpoint M (2007) Analysis of vehicle fire statistics in New Zealand parking buildings. Fire Technol 43:93–106CrossRef Li Y, Spearpoint M (2007) Analysis of vehicle fire statistics in New Zealand parking buildings. Fire Technol 43:93–106CrossRef
54.
Zurück zum Zitat Lönnermark A, Ingason H (2005) Fire spread in large industrial premises and warehouses. SP Report 2005:21. SP Swedish National Testing and Research Institute, Borås Lönnermark A, Ingason H (2005) Fire spread in large industrial premises and warehouses. SP Report 2005:21. SP Swedish National Testing and Research Institute, Borås
55.
Zurück zum Zitat Heskestad G (2002) Scaling the interaction of water sprays and flames. Fire Saf J 37:535–548CrossRef Heskestad G (2002) Scaling the interaction of water sprays and flames. Fire Saf J 37:535–548CrossRef
56.
Zurück zum Zitat Heskestad G (2003) Extinction of gas and liquid pool fires with water sprays. Fire Saf J 38:301–317CrossRef Heskestad G (2003) Extinction of gas and liquid pool fires with water sprays. Fire Saf J 38:301–317CrossRef
57.
Zurück zum Zitat Liu Z, Kim AK, Su JZ (2001) Examination of performance of water mist fire suppression systems under ventilation conditions. J Fire Prot Eng 11:164–193CrossRef Liu Z, Kim AK, Su JZ (2001) Examination of performance of water mist fire suppression systems under ventilation conditions. J Fire Prot Eng 11:164–193CrossRef
Metadaten
Titel
Full-Scale Experiments of Fire Control and Suppression in Enclosed Car Parks: A Comparison Between Sprinkler and Water-Mist Systems
verfasst von
Paolo E. Santangelo
Luca Tarozzi
Paolo Tartarini
Publikationsdatum
01.09.2016
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 5/2016
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-016-0569-3

Weitere Artikel der Ausgabe 5/2016

Fire Technology 5/2016 Zur Ausgabe