Erschienen in: Measurement Techniques 3/2016

14.07.2016 | MEDICAL AND BIOLOGICAL MEASUREMENTS

Measuring Vibration Parameters for Ultrasonic Contact Lithotripters

verfasst von: A. M. Enyakov

Erschienen in: Measurement Techniques | Ausgabe 3/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Methods are considered for measuring the parameters of ultrasonic contact lithotripters with waveguide ends executing low-amplitude longitudinal vibrations. A method is proposed for measuring vibration acceleration, vibration velocity, and the range of these vibrations using a hydrophone calibrated on a vibration test bench.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat N. K. Dzeranov and N. A. Lopatkin, Kidney Stone Disease. Clinical Recommendations, Overlei, Moscow (2007). N. K. Dzeranov and N. A. Lopatkin, Kidney Stone Disease. Clinical Recommendations, Overlei, Moscow (2007).
3.
Zurück zum Zitat A. A. Vorob’ev, A. G. Beburishvili, A. A. Tarba, et al., “Experimental support for application of endoscopic contact ultrasonic lithotripsy for gallstones,” Vestn. VolgGMU, No. 4 (40), 106–108 (2011). A. A. Vorob’ev, A. G. Beburishvili, A. A. Tarba, et al., “Experimental support for application of endoscopic contact ultrasonic lithotripsy for gallstones,” Vestn. VolgGMU, No. 4 (40), 106–108 (2011).
4.
Zurück zum Zitat E. V. Razmakhnin, S. L. Lobanov, and B. S. Khyshiktuev, “Ultrasonic intraductal lithotripsy in laparoscopic treatment of choledocholithiasis,” Endoskop. Khirurg., No. 5, 21–23 (2014). E. V. Razmakhnin, S. L. Lobanov, and B. S. Khyshiktuev, “Ultrasonic intraductal lithotripsy in laparoscopic treatment of choledocholithiasis,” Endoskop. Khirurg., No. 5, 21–23 (2014).
10.
Zurück zum Zitat IEC 61847–1998, Ultrasonics-Surgical Systems. Measurement and Declaration of the Basic Output Characteristics. IEC 61847–1998, Ultrasonics-Surgical Systems. Measurement and Declaration of the Basic Output Characteristics.
11.
Zurück zum Zitat V. T. Minchenya and D. A. Stepanenko, “Prospects for use of fl exible ultrasonic waveguide systems in medicine and engineering,” Prib. Metody Izmer., No. 1, 6–16 (2010). V. T. Minchenya and D. A. Stepanenko, “Prospects for use of fl exible ultrasonic waveguide systems in medicine and engineering,” Prib. Metody Izmer., No. 1, 6–16 (2010).
12.
Zurück zum Zitat GOST R.8-800–2012, GSI. State Calibration Chain for Vibration Displacement, Vibration Velocity, and Vibration Acceleration Measuring Instruments in the Frequency Range from 1·10 –1 Hz to 2·10 4 Hz. GOST R.8-800–2012, GSI. State Calibration Chain for Vibration Displacement, Vibration Velocity, and Vibration Acceleration Measuring Instruments in the Frequency Range from 1·10 –1 Hz to 2·10 4 Hz.
14.
Zurück zum Zitat A. J. Wang, G. T. Baldwin, J. C. Gabriel, et al., “In vitro assessment of a new portable ballistic lithotripter with percutaneous and ureteroscopic models,” J. Endourol., No. 26(11), 1500–1505 (2012). A. J. Wang, G. T. Baldwin, J. C. Gabriel, et al., “In vitro assessment of a new portable ballistic lithotripter with percutaneous and ureteroscopic models,” J. Endourol., No. 26(11), 1500–1505 (2012).
Metadaten
Titel
Measuring Vibration Parameters for Ultrasonic Contact Lithotripters
verfasst von
A. M. Enyakov
Publikationsdatum
14.07.2016
Verlag
Springer US
Erschienen in
Measurement Techniques / Ausgabe 3/2016
Print ISSN: 0543-1972
Elektronische ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-016-0962-9

Weitere Artikel der Ausgabe 3/2016

Measurement Techniques 3/2016 Zur Ausgabe