Skip to main content

2021 | OriginalPaper | Buchkapitel

12. Method Development

verfasst von : Benoît Igne, Gary McGeorge, Zhenqi Shi

Erschienen in: Near-Infrared Spectroscopy

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A general framework for method development based on the analytical quality by design process is presented and applied to the development of near-infrared spectroscopic methods. The framework is particularly well suited to secure stakeholder alignment, setting appropriate expectations and ensuring that resources are spent appropriately. After setting method goals and expectations and confirming feasibility, a risk assessment is performed to identify all the factors that could affect the method. The method is then developed with the intention to mitigate the impact of those risks. The result is a robust method that can be tested and validated if required by the regulatory environment of use. Aspects of method lifecycle are also discussed as method development is only a part of the process of successfully using near-infrared spectroscopic methods in routine commercial applications. Aspects of interface to the process, sample set selection, model optimization, system suitability, and performance monitoring are discussed in the context of building robust methods. The analytical quality by design framework can significantly streamline method development and lifecycle management efforts to ensure a successful deployment and long-term value generation from a NIR spectroscopic method. Continuous improvement ensures method performance over the useful life of the method.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat P. Borman, P. Nethercote, M. Chatfield, D. Thompson, K. Truman, The application of quality by design to analytical methods (2007) P. Borman, P. Nethercote, M. Chatfield, D. Thompson, K. Truman, The application of quality by design to analytical methods (2007)
2.
Zurück zum Zitat G.L. Reid, J. Morgado, K. Barnett, B. Harrington, J. Wang, J. Harwood, D. Fortin, Analytical Quality by Design (AQbD) in Pharmaceutical Development. American Pharmaceutical Review (2013) G.L. Reid, J. Morgado, K. Barnett, B. Harrington, J. Wang, J. Harwood, D. Fortin, Analytical Quality by Design (AQbD) in Pharmaceutical Development. American Pharmaceutical Review (2013)
3.
Zurück zum Zitat S. Wold, M. Sjöström, L. Eriksson, PLS-regression: a basic tool of chemometrics. Chemometr. Intell. Lab. Syst. 58(2), 109–130 (2001)CrossRef S. Wold, M. Sjöström, L. Eriksson, PLS-regression: a basic tool of chemometrics. Chemometr. Intell. Lab. Syst. 58(2), 109–130 (2001)CrossRef
4.
Zurück zum Zitat E.V. Thomas, D.M. Haaland, Comparison of multivariate calibration methods for quantitative spectral analysis. Anal. Chem. 62(10), 1091–1099 (1990)CrossRef E.V. Thomas, D.M. Haaland, Comparison of multivariate calibration methods for quantitative spectral analysis. Anal. Chem. 62(10), 1091–1099 (1990)CrossRef
5.
Zurück zum Zitat F. Chauchard, R. Cogdill, S. Roussel, J.M. Roger, V. Bellon-Maurel, Application of LS-SVM to non-linear phenomena in NIR spectroscopy: Development of a robust and portable sensor for acidity prediction in grapes. Chemometr. Intell. Lab. Syst. 71(2), 141–150 (2004)CrossRef F. Chauchard, R. Cogdill, S. Roussel, J.M. Roger, V. Bellon-Maurel, Application of LS-SVM to non-linear phenomena in NIR spectroscopy: Development of a robust and portable sensor for acidity prediction in grapes. Chemometr. Intell. Lab. Syst. 71(2), 141–150 (2004)CrossRef
6.
Zurück zum Zitat ICH, Pharmaceutical Development Q8(R2) (2009) ICH, Pharmaceutical Development Q8(R2) (2009)
7.
Zurück zum Zitat ICH, Validation of Analytical Procedures Q2(R1) (1996) ICH, Validation of Analytical Procedures Q2(R1) (1996)
8.
Zurück zum Zitat USFDA, Development and Submission of Near Infrared Analytical Procedures (2015) USFDA, Development and Submission of Near Infrared Analytical Procedures (2015)
9.
Zurück zum Zitat European Medicine Agency, Guideline on the Use of Near Infrared Spectroscopy by the Pharmaceutical Industry and the Data Requirements for New Submissions and Variations (2014) European Medicine Agency, Guideline on the Use of Near Infrared Spectroscopy by the Pharmaceutical Industry and the Data Requirements for New Submissions and Variations (2014)
10.
Zurück zum Zitat ASTM, Standard Guide for Multivariate Data Analysis in Pharmaceutical Development and Manufacturing Applications, in E2891–13, ASTM International: West Conshohocken, PA (2013) ASTM, Standard Guide for Multivariate Data Analysis in Pharmaceutical Development and Manufacturing Applications, in E2891–13, ASTM International: West Conshohocken, PA (2013)
11.
Zurück zum Zitat ASTM, Standard Practice for Validation of the Performance of Multivariate Online, At-Line, and Laboratory Infrared Spectrophotometer Based Analyzer Systems, in D6122-19b, ASTM International: West Conshohocken, PA (2019) ASTM, Standard Practice for Validation of the Performance of Multivariate Online, At-Line, and Laboratory Infrared Spectrophotometer Based Analyzer Systems, in D6122-19b, ASTM International: West Conshohocken, PA (2019)
12.
Zurück zum Zitat W.S. Cleveland, S.J. Devlin, Locally weighted regression: An approach to regression analysis by local fitting. J. American Stat. Assoc. 83(403), 596–610 (1988)CrossRef W.S. Cleveland, S.J. Devlin, Locally weighted regression: An approach to regression analysis by local fitting. J. American Stat. Assoc. 83(403), 596–610 (1988)CrossRef
13.
Zurück zum Zitat R.W. Kennard, L.A. Stone, Computer aided design of experiments. Technometrics 11(1), 137–148 (1969)CrossRef R.W. Kennard, L.A. Stone, Computer aided design of experiments. Technometrics 11(1), 137–148 (1969)CrossRef
14.
Zurück zum Zitat R.W. Bondi Jr., B. Igne, J.K. Drennen Iii, C.A. Anderson, Effect of experimental design on the prediction performance of calibration models based on near-infrared spectroscopy for pharmaceutical applications. Appl. Spectrosc. 66(12), 1442–1453 (2012)CrossRef R.W. Bondi Jr., B. Igne, J.K. Drennen Iii, C.A. Anderson, Effect of experimental design on the prediction performance of calibration models based on near-infrared spectroscopy for pharmaceutical applications. Appl. Spectrosc. 66(12), 1442–1453 (2012)CrossRef
15.
Zurück zum Zitat O. Scheibelhofer, B. Grabner, R.W. Bondi, B. Igne, S. Sacher, J.G. Khinast, Designed blending for near infrared calibration. J. Pharm. Sci. 104(7), 2312–2322 (2015) O. Scheibelhofer, B. Grabner, R.W. Bondi, B. Igne, S. Sacher, J.G. Khinast, Designed blending for near infrared calibration. J. Pharm. Sci. 104(7), 2312–2322 (2015)
16.
Zurück zum Zitat S. Mohan, W. Momose, J.M. Katz, M.N. Hossain, N. Velez, J.K. Drennen, C.A. Anderson, A robust quantitative near infrared modeling approach for blend monitoring. J. Pharm. Biomed. Anal. 148, 51–57 (2018)CrossRef S. Mohan, W. Momose, J.M. Katz, M.N. Hossain, N. Velez, J.K. Drennen, C.A. Anderson, A robust quantitative near infrared modeling approach for blend monitoring. J. Pharm. Biomed. Anal. 148, 51–57 (2018)CrossRef
17.
Zurück zum Zitat R.J. Barnes, M.S. Dhanoa, S.J. Lister, Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra. Appl. Spectrosc. 43(5), 772–777 (1989)CrossRef R.J. Barnes, M.S. Dhanoa, S.J. Lister, Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra. Appl. Spectrosc. 43(5), 772–777 (1989)CrossRef
18.
Zurück zum Zitat P. Geladi, D. MacDougall, H. Martens, Linearization and scatter-correction for near-infrared reflectance spectra of meat. Appl. Spectrosc. 39(3), 491–500 (1985)CrossRef P. Geladi, D. MacDougall, H. Martens, Linearization and scatter-correction for near-infrared reflectance spectra of meat. Appl. Spectrosc. 39(3), 491–500 (1985)CrossRef
19.
Zurück zum Zitat H. Mark, R. Rubinovitz, D. Heaps, P. Gemperline, D. Dahm, K. Dahm, Comparison of the use of volume fractions with other measures of concentration for quantitative spectroscopic calibration using the classical least squares method. Appl. Spectrosc. 64(9), 995–1006 (2010)CrossRef H. Mark, R. Rubinovitz, D. Heaps, P. Gemperline, D. Dahm, K. Dahm, Comparison of the use of volume fractions with other measures of concentration for quantitative spectroscopic calibration using the classical least squares method. Appl. Spectrosc. 64(9), 995–1006 (2010)CrossRef
20.
Zurück zum Zitat ASTM, Standard Guide for Risk-Based Validation of Analytical Methods for PAT Applications. In E2898–14 (2014) ASTM, Standard Guide for Risk-Based Validation of Analytical Methods for PAT Applications. In E2898–14 (2014)
21.
Zurück zum Zitat J.J. Workman Jr., A review of calibration transfer practices and instrument differences in spectroscopy. Appl. Spectrosc. 72(3), 340–365 (2018)CrossRef J.J. Workman Jr., A review of calibration transfer practices and instrument differences in spectroscopy. Appl. Spectrosc. 72(3), 340–365 (2018)CrossRef
Metadaten
Titel
Method Development
verfasst von
Benoît Igne
Gary McGeorge
Zhenqi Shi
Copyright-Jahr
2021
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-8648-4_12

Neuer Inhalt