Skip to main content

2015 | OriginalPaper | Buchkapitel

Model-Based Estimation of Microscopic Anisotropy in Macroscopically Isotropic Substrates Using Diffusion MRI

verfasst von : Andrada Ianuş, Ivana Drobnjak, Daniel C. Alexander

Erschienen in: Information Processing in Medical Imaging

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Non-invasive estimation of cell size and shape is a key challenge in diffusion MRI. Changes in cell size and shape discriminate functional areas in the brain and can highlight different degrees of malignancy in cancer tumours. Consequently various methods have emerged recently that aim to measure the microscopic anisotropy of porous media such as biological tissue and aim to reflect pore eccentricity, the simplest shape feature. However, current methods assume a substrate of identical pores, and are strongly influenced by non-trivial size distribution. This paper presents a model-based approach that provides estimates of pore size and shape from diffusion MRI data. The technique uses a geometric model of randomly oriented finite cylinders with gamma distributed radii. We use Monte Carlo simulation to generate synthetic data in substrates consisting of randomly oriented cuboids with various size distributions and eccentricities. We compare the sensitivity of single and double pulsed field gradient (sPFG and dPFG) sequences to the size distribution and eccentricity and further compare different protocols of dPFG sequences with parallel and/or perpendicular pairs of gradients. The key result demonstrates that this model-based approach can provide features of pore shape (specifically eccentricity) that are independent of the size distribution unlike previous attempts to characterise microscopic anisotropy. We show further that explicitly accounting for size distribution is necessary for accurate estimates of average size and eccentricity, and a model that assumes a single size fails to recover the ground truth values. We find the most accurate parameter estimates for dPFG sequences with mixed parallel and perpendicular gradients, nevertheless all other sequences, including sPFG, show sensitivity as well.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Panagiotaki, E., Walker-Samuel, S., Siow, B., Johnson, S.P., Rajkumar, V., Pedley, R.B., Lythgoe, M.F., Alexander, D.C.: Noninvasive quantification of solid tumor microstructure using verdict MRI. Cancer Res. 74, 1902–1912 (2014)CrossRef Panagiotaki, E., Walker-Samuel, S., Siow, B., Johnson, S.P., Rajkumar, V., Pedley, R.B., Lythgoe, M.F., Alexander, D.C.: Noninvasive quantification of solid tumor microstructure using verdict MRI. Cancer Res. 74, 1902–1912 (2014)CrossRef
2.
Zurück zum Zitat Savadiev, P., Campbell, J.S.W., Descoteaux, M., Deriche, R., Pike, G.B., Siddiqi, K.: Labeling of ambiguous subvoxel fibre bundle configurations in high angular resolution diffusion MRI. NeuroImage 41, 58–68 (2008)CrossRef Savadiev, P., Campbell, J.S.W., Descoteaux, M., Deriche, R., Pike, G.B., Siddiqi, K.: Labeling of ambiguous subvoxel fibre bundle configurations in high angular resolution diffusion MRI. NeuroImage 41, 58–68 (2008)CrossRef
3.
Zurück zum Zitat Nilsson, M., Latt, J., Stahlberg, F., van Westen, D., Hagslätt, H.: The importance of axonal undulation in diffusion MR measurements: a monte carlo simulation study. NMR Biomed. 25, 795–805 (2012)CrossRef Nilsson, M., Latt, J., Stahlberg, F., van Westen, D., Hagslätt, H.: The importance of axonal undulation in diffusion MR measurements: a monte carlo simulation study. NMR Biomed. 25, 795–805 (2012)CrossRef
4.
Zurück zum Zitat Kleinnijenhuis, M., Zerbi, V., Küsters, B., Slump, C.H., Barth, M., van Cappellen van Walsum, A.: Layer-specific diffusion weighted imaging in human primary visual cortex in vitro. Cortex 49, 2569–2582 (2013)CrossRef Kleinnijenhuis, M., Zerbi, V., Küsters, B., Slump, C.H., Barth, M., van Cappellen van Walsum, A.: Layer-specific diffusion weighted imaging in human primary visual cortex in vitro. Cortex 49, 2569–2582 (2013)CrossRef
5.
Zurück zum Zitat Novikov, M., Jensen, J.H., Helpern, J.A., Fieremans, E.: Revealing mesoscopic structural universality with diffusion. Proc. Nat. Acad. Sci. 11, 5088–5093 (2014)CrossRef Novikov, M., Jensen, J.H., Helpern, J.A., Fieremans, E.: Revealing mesoscopic structural universality with diffusion. Proc. Nat. Acad. Sci. 11, 5088–5093 (2014)CrossRef
6.
Zurück zum Zitat Assaf, Y., Blumenfeld-Katzir, T., Yovel, Y., Basser, P.J.: AxCaliber: a method for measuring axon diameter distribution from diffusion MRI. Magn. Reson. Med. 59, 1347–1354 (2008)CrossRef Assaf, Y., Blumenfeld-Katzir, T., Yovel, Y., Basser, P.J.: AxCaliber: a method for measuring axon diameter distribution from diffusion MRI. Magn. Reson. Med. 59, 1347–1354 (2008)CrossRef
7.
Zurück zum Zitat Alexander, D.C., Hubbard, P.L., Hall, M.G., Moore, E.A., Ptito, M., Parker, G.J.M., Dyrby, T.B.: Orientationally invariant indices of axon diameter and density from diffusion MRI. NeuroImage 52, 1374–1389 (2010)CrossRef Alexander, D.C., Hubbard, P.L., Hall, M.G., Moore, E.A., Ptito, M., Parker, G.J.M., Dyrby, T.B.: Orientationally invariant indices of axon diameter and density from diffusion MRI. NeuroImage 52, 1374–1389 (2010)CrossRef
8.
Zurück zum Zitat Ferizi, U., Schneider, T., Panagiotaki, E., Nedjati-Gilani, G., Zhang, H., Wheeler-Kingshott, C., Alexander, D.C.: A ranking of diffusion MRI compartment models with in vivo human brain data. Magn. Reson. Med. 72, 1785–92 (2014)CrossRef Ferizi, U., Schneider, T., Panagiotaki, E., Nedjati-Gilani, G., Zhang, H., Wheeler-Kingshott, C., Alexander, D.C.: A ranking of diffusion MRI compartment models with in vivo human brain data. Magn. Reson. Med. 72, 1785–92 (2014)CrossRef
9.
Zurück zum Zitat Cory, D.G., Garroway, A.N., Miller, J.B.: Applications of spin transport as a probe of local geometry. Polym. Prepr. 31, 149–150 (1990) Cory, D.G., Garroway, A.N., Miller, J.B.: Applications of spin transport as a probe of local geometry. Polym. Prepr. 31, 149–150 (1990)
10.
Zurück zum Zitat Mitra, P.P.: Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement. Phys. Rev. B 51(21), 15074–15078 (1995)CrossRef Mitra, P.P.: Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement. Phys. Rev. B 51(21), 15074–15078 (1995)CrossRef
11.
Zurück zum Zitat Lawrenz, M., Koch, M.A., Finsterbusch, J.: A tensor model and measures of microscopic anisotropy for double-wave-vector diffusion-weighting experiments with long mixing times. J. Magn. Reson. 202, 43–56 (2010)CrossRef Lawrenz, M., Koch, M.A., Finsterbusch, J.: A tensor model and measures of microscopic anisotropy for double-wave-vector diffusion-weighting experiments with long mixing times. J. Magn. Reson. 202, 43–56 (2010)CrossRef
12.
Zurück zum Zitat Jespersen, S.N., Lundell, H., Sonderby, C.K., Dyrby, T.B.: Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments. NMR Biomed. 26, 1647–1662 (2013)CrossRef Jespersen, S.N., Lundell, H., Sonderby, C.K., Dyrby, T.B.: Orientationally invariant metrics of apparent compartment eccentricity from double pulsed field gradient diffusion experiments. NMR Biomed. 26, 1647–1662 (2013)CrossRef
13.
Zurück zum Zitat Lasic, S., Szczepankiewicz, F., Eriksson, S., Nilsson, M., Topgaard, D.: Microanisotropy imaging: quantification of microscopic diffusion anisotropy and orientational order parameter by diffusion MRI with magic-angle spinning of the q-vector. Front. Phys. 2 (2014) Lasic, S., Szczepankiewicz, F., Eriksson, S., Nilsson, M., Topgaard, D.: Microanisotropy imaging: quantification of microscopic diffusion anisotropy and orientational order parameter by diffusion MRI with magic-angle spinning of the q-vector. Front. Phys. 2 (2014)
14.
Zurück zum Zitat Ozarslan, E.: Compartment shape anisotropy (CSA) revealed by double pulsed field gradient MR. J. Magn. Reson. 199, 56–67 (2009)CrossRef Ozarslan, E.: Compartment shape anisotropy (CSA) revealed by double pulsed field gradient MR. J. Magn. Reson. 199, 56–67 (2009)CrossRef
15.
Zurück zum Zitat Shemesh, N., Ozarslan, E., Basser, P.J., Cohen, Y.: Accurate noninvasive measurement of cell size and compartment shape anisotropy in yeast cells using double-pulsed field gradient MR. NMR Biomed. 25, 236–246 (2012)CrossRef Shemesh, N., Ozarslan, E., Basser, P.J., Cohen, Y.: Accurate noninvasive measurement of cell size and compartment shape anisotropy in yeast cells using double-pulsed field gradient MR. NMR Biomed. 25, 236–246 (2012)CrossRef
16.
Zurück zum Zitat Zhang, H., Hubbard, P.L., Parker, G.J.M., Alexander, D.C.: Axon diameter mapping in the presence of orientation dispersion with diffusion MRI. NeuroImage 56, 1301–1315 (2011)CrossRef Zhang, H., Hubbard, P.L., Parker, G.J.M., Alexander, D.C.: Axon diameter mapping in the presence of orientation dispersion with diffusion MRI. NeuroImage 56, 1301–1315 (2011)CrossRef
17.
Zurück zum Zitat Komlosh, M.E., Ozarslan, E., Lizak, M.J., Horkay, F., Schram, V., Shemesh, N., Cohen, Y., Basser, P.J.: Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom. J. Magn. Reson. 208, 128–135 (2011)CrossRef Komlosh, M.E., Ozarslan, E., Lizak, M.J., Horkay, F., Schram, V., Shemesh, N., Cohen, Y., Basser, P.J.: Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom. J. Magn. Reson. 208, 128–135 (2011)CrossRef
18.
Zurück zum Zitat Hall, M., Alexander, D.C.: Convergence and parameter choice for Monte-Carlo simulations of diffusion MRI. IEEE Trans. Med. Imaging 28, 1354–1364 (2009)CrossRef Hall, M., Alexander, D.C.: Convergence and parameter choice for Monte-Carlo simulations of diffusion MRI. IEEE Trans. Med. Imaging 28, 1354–1364 (2009)CrossRef
19.
Zurück zum Zitat Neuman, C.H.: Spin echo of spins diffusing in a bounded medium. J. Chem. Phys. 60, 4508–4511 (1974)CrossRef Neuman, C.H.: Spin echo of spins diffusing in a bounded medium. J. Chem. Phys. 60, 4508–4511 (1974)CrossRef
20.
Zurück zum Zitat Assaf, Y., Freidlin, R.Z., Rohde, G.K., Basser, P.J.: New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter. Magn. Reson. Med. 52, 965–978 (2004)CrossRef Assaf, Y., Freidlin, R.Z., Rohde, G.K., Basser, P.J.: New modeling and experimental framework to characterize hindered and restricted water diffusion in brain white matter. Magn. Reson. Med. 52, 965–978 (2004)CrossRef
21.
Zurück zum Zitat Stepisnik, J.: Time-dependent self-diffusion by NMR spin echo. Phys. B 183, 343–350 (1993)CrossRef Stepisnik, J.: Time-dependent self-diffusion by NMR spin echo. Phys. B 183, 343–350 (1993)CrossRef
22.
Zurück zum Zitat Dyrby, T.B., Søgaard, L.V., Hall, M.G., Ptito, M., Alexander, D.C.: Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI. Magn. Reson. Med. 70, 711–721 (2013)CrossRef Dyrby, T.B., Søgaard, L.V., Hall, M.G., Ptito, M., Alexander, D.C.: Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI. Magn. Reson. Med. 70, 711–721 (2013)CrossRef
23.
Zurück zum Zitat Alexander, D.C.: A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features. Magn. Reson. Med. 60, 439–448 (2008)CrossRef Alexander, D.C.: A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features. Magn. Reson. Med. 60, 439–448 (2008)CrossRef
Metadaten
Titel
Model-Based Estimation of Microscopic Anisotropy in Macroscopically Isotropic Substrates Using Diffusion MRI
verfasst von
Andrada Ianuş
Ivana Drobnjak
Daniel C. Alexander
Copyright-Jahr
2015
DOI
https://doi.org/10.1007/978-3-319-19992-4_55

Premium Partner