Skip to main content

2020 | OriginalPaper | Buchkapitel

Non-invasive Diabetes Level Monitoring System Using Artificial Intelligence and UWB

verfasst von : Minarul Islam, Sabira Khatun, Nusrat Jahan Shoumy, Md. Shawkat Ali, Mohamad Shaiful Abdul Karim, Bifta Sama Bari

Erschienen in: Cyber Security and Computer Science

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Diabetes is a silent-killer disease throughout the world. It is not curable, therefore, regular blood glucose concentration levels (BGCL) monitoring is necessary to be healthy in a long run. The traditional way of BGCL measurement is invasive by pricking and collecting blood sample from human arm (or finger-tip), then measuring the level either using a glucometer or sending to laboratory. This blood collecting process produces significant discomfort to the patients, especially to the children with type-A diabetes, resulting increased undetected-cases and health-complications. To overcome this drawbacks, a non-invasive ultra-wideband (UWB) BGCL measurement system is proposed here with enhanced software module. The hardware can be controlled through the graphical user interface (GUI) of software and can execute signal processing, feature extraction, and feature classification using artificial intelligence (AI). As AI, cascade forward neural network (CFNN) and naïve bayes (NB) algorithms are investigated, then CFNN with four independent features (skewness, kurtosis, variance, mean-absolute-deviation) are found to be best-suited for BGCL estimation. A transmit (Tx) antenna was placed at one side of left-earlobe to Tx UWB signals, and a receive (Rx) antenna at opposite side to Rx transmitted signals with BGCL marker. These signals are saved and used for AI training, validation and testing. The system with CFNN shows approximately 86.62% accuracy for BGCL measurement, which is 5.62% improved compared to other methods by showing its superiority. This enhanced system is affordable, effective and easy-to-use for all users (home and hospital), to reduce undetected diabetes cases and related mortality rate in near future.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat (NIH) National Institute of Diabetes and Digestive and Kidney Diseases: Your guide to diabetes; Type 1 and Type 2. Natl. Inst. Diabetes Dig. Kidney Dis. 14, 1–67 (2013) (NIH) National Institute of Diabetes and Digestive and Kidney Diseases: Your guide to diabetes; Type 1 and Type 2. Natl. Inst. Diabetes Dig. Kidney Dis. 14, 1–67 (2013)
11.
Zurück zum Zitat Osiecka, I., Pałko, T., Łukasik, W., Pijanowska, D., Dudziński, K.: Impedance spectroscopy as a method for the measurement of calibrated glucose solutions with concentration occurring in human blood. In: Jabłoński, R., Szewczyk, R. (eds.) Recent Global Research and Education: Technological Challenges. AISC, vol. 519, pp. 211–216. Springer, Cham (2017). https://doi.org/10.1007/978-3-319-46490-9_30CrossRef Osiecka, I., Pałko, T., Łukasik, W., Pijanowska, D., Dudziński, K.: Impedance spectroscopy as a method for the measurement of calibrated glucose solutions with concentration occurring in human blood. In: Jabłoński, R., Szewczyk, R. (eds.) Recent Global Research and Education: Technological Challenges. AISC, vol. 519, pp. 211–216. Springer, Cham (2017). https://​doi.​org/​10.​1007/​978-3-319-46490-9_​30CrossRef
12.
Zurück zum Zitat Arakawa, M., et al.: Red blood cell aggregation measurement with 40-MHz ultrasound has a possibility for noninvasive evaluation of blood glucose level in patients with diabetes. In: IEEE International Ultrasonics Symposium, IUS. IEEE Computer Society (2018). https://doi.org/10.1109/ULTSYM.2018.8580086 Arakawa, M., et al.: Red blood cell aggregation measurement with 40-MHz ultrasound has a possibility for noninvasive evaluation of blood glucose level in patients with diabetes. In: IEEE International Ultrasonics Symposium, IUS. IEEE Computer Society (2018). https://​doi.​org/​10.​1109/​ULTSYM.​2018.​8580086
13.
Zurück zum Zitat Li, R., Liu, G., Xia, X., Liu, T., Hu, Z.: The studies of noninvasive blood glucose monitoring using optical coherence tomography. In: Ma, X., Wu, F., Fan, B., Li, X., Zhang, Y. (eds.) 9th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment, p. 44. SPIE (2019). https://doi.org/10.1117/12.2505124 Li, R., Liu, G., Xia, X., Liu, T., Hu, Z.: The studies of noninvasive blood glucose monitoring using optical coherence tomography. In: Ma, X., Wu, F., Fan, B., Li, X., Zhang, Y. (eds.) 9th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test, Measurement Technology, and Equipment, p. 44. SPIE (2019). https://​doi.​org/​10.​1117/​12.​2505124
16.
Zurück zum Zitat Lim, E.G., Wang, Z., Lei, C.U., Wang, Y., Man, K.L.: Ultra wideband antennas - past and present. IAENG Int. J. Comput. Sci. 37, 1–12 (2010) Lim, E.G., Wang, Z., Lei, C.U., Wang, Y., Man, K.L.: Ultra wideband antennas - past and present. IAENG Int. J. Comput. Sci. 37, 1–12 (2010)
19.
Zurück zum Zitat Ali, M.S., Shoumy, N.J., Khatun, S., Kamarudin, L.M., Vijayasarveswari, V.: Non-invasive blood glucose measurement performance analysis through UWB imaging. In: 2016 3rd International Conference on Electronic Design, ICED 2016, pp. 513–516. Institute of Electrical and Electronics Engineers Inc. (2017). https://doi.org/10.1109/ICED.2016.7804698 Ali, M.S., Shoumy, N.J., Khatun, S., Kamarudin, L.M., Vijayasarveswari, V.: Non-invasive blood glucose measurement performance analysis through UWB imaging. In: 2016 3rd International Conference on Electronic Design, ICED 2016, pp. 513–516. Institute of Electrical and Electronics Engineers Inc. (2017). https://​doi.​org/​10.​1109/​ICED.​2016.​7804698
20.
Zurück zum Zitat Ali, M.S., Khatun, S., Kamarudin, L.M., Shoumy, N.J., Islam, M.: Non-invasive ultra-wide band system for reliable blood glucose level detection. Int. J. Appl. Eng. Res. 11, 8373–8376 (2016) Ali, M.S., Khatun, S., Kamarudin, L.M., Shoumy, N.J., Islam, M.: Non-invasive ultra-wide band system for reliable blood glucose level detection. Int. J. Appl. Eng. Res. 11, 8373–8376 (2016)
21.
Zurück zum Zitat Reza, K.J., Khatun, S., Jamlos, M.F., Fakir, M.M., Morshed, M.N.: Performance enhancement of ultra-wideband breast cancer imaging system: proficient feature extraction and biomedical antenna approach. J. Med. Imaging Heal. Inf. 5, 1246–1250 (2015)CrossRef Reza, K.J., Khatun, S., Jamlos, M.F., Fakir, M.M., Morshed, M.N.: Performance enhancement of ultra-wideband breast cancer imaging system: proficient feature extraction and biomedical antenna approach. J. Med. Imaging Heal. Inf. 5, 1246–1250 (2015)CrossRef
Metadaten
Titel
Non-invasive Diabetes Level Monitoring System Using Artificial Intelligence and UWB
verfasst von
Minarul Islam
Sabira Khatun
Nusrat Jahan Shoumy
Md. Shawkat Ali
Mohamad Shaiful Abdul Karim
Bifta Sama Bari
Copyright-Jahr
2020
DOI
https://doi.org/10.1007/978-3-030-52856-0_30

Premium Partner