On Parameters Affecting the Sensitivity of Ultrasonic Testing of Tubes: Experimental and Simulation

verfasst von: K. Kapoor, K. Sunder Krishna, Shaik Allah Bakshu

Erschienen in: Journal of Nondestructive Evaluation | Ausgabe 4/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The response (amplitude) of the reference notch during ultrasonic testing of tubes is dependent on several parameters like (1) size, shape and location of notch in the material (2) operating parameters like pitch, incidence angle, focusing, beam profile etc (3) Electronic parameters like PRF, pulse width etc. A thorough analysis of several parameters is made in this paper which affects the calibration sensitivity and its repeatability. Calibration during ultrasonic testing of tubes is carried out by using reference notches made on the tubes. The size and shape of the reference notches are defined in the specification of the tube. Different specifications like ASTM, ASME, AMS, BS etc recommend the type of notch to be used for calibration. These are varying from one standard to another and there is no comparison available for the achieved sensitivity during calibration. This paper deals with a comparison of the recommended size and shape of the notches in different codes and specifications. The sensitivity of test is dependent on the calibration notch size and shape. In the present work a comparison is made on the sensitivity (in terms of gain level) for different size and shape of notches used during calibration of a tube. Usually, these notches are made on the ID and OD surface of the tubes which are generally equal in size. During calibration equalization of the amplitude of indication from the ID and OD is recommended. However no sound basis is available for the reason for unequal amplitude indication from ID and OD notch. In the present work, response from the notches at ID and OD is experimentally determined and compared with modeling of the response from the ID and OD notches. The repeatability of the calibration is demonstrated by carrying out a series of repeated measurements of the gain of the response from the notch. Different specifications recommend different tests for demonstrating the repeatability of the calibration. A comparison is made here for the repeatability requirements in different specifications. An analysis of the operating and electronic parameters responsible for variation in gain during a repeatability test is made.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat AMS Standard specifications for aerospace material specification for ultrasonic inspection of thin wall metal tubing, AMS 2634, SAE International, Warrendale, pp. 1–14 (2013) AMS Standard specifications for aerospace material specification for ultrasonic inspection of thin wall metal tubing, AMS 2634, SAE International, Warrendale, pp. 1–14 (2013)
2.
Zurück zum Zitat ASTM Standard specifications for standard practice for ultrasonic testing of metal pipe and tubing, ASTM E 213, ASTM International, Philadelphia, pp. 1–11 (2009) ASTM Standard specifications for standard practice for ultrasonic testing of metal pipe and tubing, ASTM E 213, ASTM International, Philadelphia, pp. 1–11 (2009)
3.
Zurück zum Zitat ASTM Standard specifications for recommended procedure for ultrasonic testing of zirconium and zirconium alloy tubing for nuclear service, ASTM B 353, Annexure 3, ASTM International, Philadelphia, pp. 1–19 (2012) ASTM Standard specifications for recommended procedure for ultrasonic testing of zirconium and zirconium alloy tubing for nuclear service, ASTM B 353, Annexure 3, ASTM International, Philadelphia, pp. 1–19 (2012)
4.
Zurück zum Zitat ASTM Standard specifications for austenitic stainless steel tubing for breeder reactor components, ASTM A771, Philadelphia, pp. 1–16 (1990) ASTM Standard specifications for austenitic stainless steel tubing for breeder reactor components, ASTM A771, Philadelphia, pp. 1–16 (1990)
5.
Zurück zum Zitat ASME Boiler and pressure vessel code, sec V NB 2550: examination and repair of seamless and welded (without filler metal) tubular products and fittings (2013) pp. 1–4 ASME Boiler and pressure vessel code, sec V NB 2550: examination and repair of seamless and welded (without filler metal) tubular products and fittings (2013) pp. 1–4
6.
Zurück zum Zitat Beck, K.H.: Ultrasonic transducer focusing for inspection of cylindrical material. Mater. Eval. 49, 879–882 (1989) Beck, K.H.: Ultrasonic transducer focusing for inspection of cylindrical material. Mater. Eval. 49, 879–882 (1989)
7.
Zurück zum Zitat Beck, K.H.: Cost effective ultrasonic inspection of tubes. Tube Pipe Technol. 1(5), 31–38 (1988) Beck, K.H.: Cost effective ultrasonic inspection of tubes. Tube Pipe Technol. 1(5), 31–38 (1988)
8.
Zurück zum Zitat Beck, K.H.: Ultrasonic transducer array configuration for interlaced scanning. Mater. Eval. 46(6), 771–772 (1988) Beck, K.H.: Ultrasonic transducer array configuration for interlaced scanning. Mater. Eval. 46(6), 771–772 (1988)
9.
Zurück zum Zitat CIVA\(^{{\rm nde} }\)Software, EXTENDE, Incuballiance, Orsay CIVA\(^{{\rm nde} }\)Software, EXTENDE, Incuballiance, Orsay
Metadaten
Titel
On Parameters Affecting the Sensitivity of Ultrasonic Testing of Tubes: Experimental and Simulation
verfasst von
K. Kapoor
K. Sunder Krishna
Shaik Allah Bakshu
Publikationsdatum
01.12.2016
Verlag
Springer US
Erschienen in
Journal of Nondestructive Evaluation / Ausgabe 4/2016
Print ISSN: 0195-9298
Elektronische ISSN: 1573-4862
DOI
https://doi.org/10.1007/s10921-016-0371-7

Weitere Artikel der Ausgabe 4/2016

Journal of Nondestructive Evaluation 4/2016 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.