Skip to main content

2022 | OriginalPaper | Buchkapitel

33. PD Detection and Analysis of Cross-Bonded Cable Based on Broadband Sensor and Three-Phase Amplitude Relation Analysis Method

verfasst von : Liwei Wang, Bingwei Liu, Bin Wang, Xutao Han, Zhentao Liu, Wei Sun

Erschienen in: Advances in Smart Vehicular Technology, Transportation, Communication and Applications

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The power cable is one of the most important transmission equipment. The long cable common use the cross-bonded grounding method to reduce the loss of shielding layer and decrease the voltage rise at the end of cable. Therefore, it is difficult to diagnosis the PD detection result of cross-bonded cable in field because the PD signals will be influenced by both the environment electromagnet interference and the interference among different phases. The broad band sensor is used to detect the PD of cross-bonded cable in field in this paper. The waveform of the PD pulse, PRPD, and 3PARD diagrams are analyzed to diagnose the results. The results have shown that the broadband sensor can anti the environment electromagnet interference because it can obtain more information of PD signal. The 3PARD diagrams can division the interference among different phases.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Petzold, F., Schlapp, H., Gulski, E.: Advanced solution for on-site diagnosis of distribution power cables. IEEE Trans. Dielectr. Electr. Insul. 15(6), 1584–1589 (2008)CrossRef Petzold, F., Schlapp, H., Gulski, E.: Advanced solution for on-site diagnosis of distribution power cables. IEEE Trans. Dielectr. Electr. Insul. 15(6), 1584–1589 (2008)CrossRef
2.
Zurück zum Zitat He, W., Wang, Q., Huang, C., et al.: A novel noise elimination method for PD measurement of on-site MV cable using frequency-tuned resonant system. In: 2016 International Conference on Condition Monitoring and Diagnosis (CMD), Xi’an, China (2016) He, W., Wang, Q., Huang, C., et al.: A novel noise elimination method for PD measurement of on-site MV cable using frequency-tuned resonant system. In: 2016 International Conference on Condition Monitoring and Diagnosis (CMD), Xi’an, China (2016)
3.
Zurück zum Zitat Putter, H.T., Gotz, D., Petzold, F., et al.: Innovative solutions for on-site diagnosis of distribution power cables. In: Transmission & Distribution Conference & Exposition. IEEE (2012) Putter, H.T., Gotz, D., Petzold, F., et al.: Innovative solutions for on-site diagnosis of distribution power cables. In: Transmission & Distribution Conference & Exposition. IEEE (2012)
4.
Zurück zum Zitat Koltunowicz, W., Plath, R.: Synchronous multi-channel PD measurements. IEEE Trans. Dielectr. Electr. Insul. 15(6), 1715–1723 (2008)CrossRef Koltunowicz, W., Plath, R.: Synchronous multi-channel PD measurements. IEEE Trans. Dielectr. Electr. Insul. 15(6), 1715–1723 (2008)CrossRef
5.
Zurück zum Zitat Kraetge, A., Hoek, S., Hummel, R., et al.: De-noising approaches for partial discharge measurements—a comparison of methods and their practical application. In: International Conference on Condition Monitoring and Diagnosis. IEEE (2013) Kraetge, A., Hoek, S., Hummel, R., et al.: De-noising approaches for partial discharge measurements—a comparison of methods and their practical application. In: International Conference on Condition Monitoring and Diagnosis. IEEE (2013)
6.
Zurück zum Zitat Yin, Y., Li, Z.: Research on a practical de-noising method and the characterization of partial discharge UHF signals. IEEE Trans. Dielectr. Elect. Insul. 21(5), 2206–2216 (2014) Yin, Y., Li, Z.: Research on a practical de-noising method and the characterization of partial discharge UHF signals. IEEE Trans. Dielectr. Elect. Insul. 21(5), 2206–2216 (2014)
7.
Zurück zum Zitat Henseler, J., Chin, W.W.: A comparison of approaches for the analysis of interaction effects between latent variables using partial least squares path modeling. Struct. Eqn. Model. Multi. J. 17(1), 82–109 (2010) Henseler, J., Chin, W.W.: A comparison of approaches for the analysis of interaction effects between latent variables using partial least squares path modeling. Struct. Eqn. Model. Multi. J. 17(1), 82–109 (2010)
Metadaten
Titel
PD Detection and Analysis of Cross-Bonded Cable Based on Broadband Sensor and Three-Phase Amplitude Relation Analysis Method
verfasst von
Liwei Wang
Bingwei Liu
Bin Wang
Xutao Han
Zhentao Liu
Wei Sun
Copyright-Jahr
2022
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-16-4039-1_33

    Premium Partner