Skip to main content

2020 | OriginalPaper | Buchkapitel

Principal Factors Affecting the Accuracy of Real-Time Power Monitoring Data in Large Public Buildings

verfasst von : Jialin Wu, Zhuling Zheng, Zhiwei Lian, Dayi Lai

Erschienen in: Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019)

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Building energy monitoring system is an effective measure to provide the energy consumption information in large-scale public buildings. However, in actual operation process, many errors may occur in the existing measurement due to the low accuracy of the instruments and mistakes in human operation. This study proposed a novel method to improve the accuracy of power monitoring data at a low instrument cost. In this method, two sets of comparative data, obtained by conventional and high-precision instruments, respectively, were measured on a self-designed test rig. The changes of the relative differences between the two sets of data were quantitatively studied considering three factors, including load rate, cable cross-sectional area, and its length on the secondary side. The results show that the measurements should be carried out under recommended conditions in engineering applications when the load rate is at more than 20%, the cable cross-sectional area at 4 mm2, and the length of cables less than 50 m. The method proposed in this study can effectively achieve the accuracy of energy consumption data through background processing based on the existing ammeters in large public buildings.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Luo, M.H.: Analysis of potential, characteristics and driving force of energy-saving reconstruction in large-scale public buildings. Urban Constr. Theory Res. (13) (2011) Luo, M.H.: Analysis of potential, characteristics and driving force of energy-saving reconstruction in large-scale public buildings. Urban Constr. Theory Res. (13) (2011)
2.
Zurück zum Zitat Xu, Q., Zhi, J.J., et al.: Energy consumption data analysis of Shanghai public building energy consumption surveillance platform. Shanghai Energy Conserv. 6, 317–321 (2017) Xu, Q., Zhi, J.J., et al.: Energy consumption data analysis of Shanghai public building energy consumption surveillance platform. Shanghai Energy Conserv. 6, 317–321 (2017)
3.
Zurück zum Zitat Ferreira, V., Fleming, P.: The use of sub-hourly primary meter data to identify electricity savings in municipal buildings. Energ. Effi. 7(5), 879–889 (2014)CrossRef Ferreira, V., Fleming, P.: The use of sub-hourly primary meter data to identify electricity savings in municipal buildings. Energ. Effi. 7(5), 879–889 (2014)CrossRef
4.
Zurück zum Zitat Li, X., Bowers, C., et al.: Classification of energy consumption in buildings with outlier detection. IEEE Trans. Industr. Electron. 57(11), 3639–3644 (2010)CrossRef Li, X., Bowers, C., et al.: Classification of energy consumption in buildings with outlier detection. IEEE Trans. Industr. Electron. 57(11), 3639–3644 (2010)CrossRef
5.
Zurück zum Zitat Seem, J.: Using intelligent data analysis to detect abnormal energy consumption in buildings. Energy Build. 39(1), 52–58 (2007)CrossRef Seem, J.: Using intelligent data analysis to detect abnormal energy consumption in buildings. Energy Build. 39(1), 52–58 (2007)CrossRef
6.
Zurück zum Zitat Dodier, R., Kreider, J.: Detecting whole building energy problems. ASHRAE Trans. 1, 579–589 (1999) Dodier, R., Kreider, J.: Detecting whole building energy problems. ASHRAE Trans. 1, 579–589 (1999)
7.
Zurück zum Zitat Motegi, N., Piette, M.A., et al: Case studies of energy information systems and related technology: operational practices, costs, and benefits. Texas A & M University (2003) Motegi, N., Piette, M.A., et al: Case studies of energy information systems and related technology: operational practices, costs, and benefits. Texas A & M University (2003)
8.
Zurück zum Zitat Wang, Z., Srinivasan, R.S.: A review of artificial intelligence based buildings energy use prediction: contrasting the capabilities of single and ensemble prediction models. Renew. Sustain. Energy Rev. 75, 796–808 (2017)CrossRef Wang, Z., Srinivasan, R.S.: A review of artificial intelligence based buildings energy use prediction: contrasting the capabilities of single and ensemble prediction models. Renew. Sustain. Energy Rev. 75, 796–808 (2017)CrossRef
9.
Zurück zum Zitat Chen, L., Tu, S.C.: Common problems and methods of sub-metering data quality. Constr. Sci. Technol. 14, 84–85 (2016) Chen, L., Tu, S.C.: Common problems and methods of sub-metering data quality. Constr. Sci. Technol. 14, 84–85 (2016)
10.
Zurück zum Zitat Wu, W.Q.: Identification and repair method of building energy consumption monitoring data based on machine learning algorithm. Constr. Sci. Technol. 9, 60–62 (2017) Wu, W.Q.: Identification and repair method of building energy consumption monitoring data based on machine learning algorithm. Constr. Sci. Technol. 9, 60–62 (2017)
Metadaten
Titel
Principal Factors Affecting the Accuracy of Real-Time Power Monitoring Data in Large Public Buildings
verfasst von
Jialin Wu
Zhuling Zheng
Zhiwei Lian
Dayi Lai
Copyright-Jahr
2020
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-9528-4_29