Skip to main content
Erschienen in:
Buchtitelbild

2019 | OriginalPaper | Buchkapitel

Robust Cochlear Modiolar Axis Detection in CT

verfasst von : Wilhelm Wimmer, Clair Vandersteen, Nicolas Guevara, Marco Caversaccio, Hervé Delingette

Erschienen in: Medical Image Computing and Computer Assisted Intervention – MICCAI 2019

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The cochlea, the auditory part of the inner ear, is a spiral-shaped organ with large morphological variability. An individualized assessment of its shape is essential for clinical applications related to tonotopy and cochlear implantation. To unambiguously reference morphological parameters, reliable recognition of the cochlear modiolar axis in computed tomography (CT) images is required. The conventional method introduces measurement uncertainties, as it is based on manually selected and difficult to identify landmarks. Herein, we present an algorithm for robust modiolar axis detection in clinical CT images. We define the modiolar axis as the rotation component of the kinematic spiral motion inherent in the cochlear shape. For surface fitting, we use a compact shape representation in a 7-dimensional kinematic parameter space based on extended Plücker coordinates. It is the first time such a kinematic representation is used for shape analysis in medical images. Robust surface fitting is achieved with an adapted approximate maximum likelihood method assuming a Student-t distribution, enabling axis detection even in partially available surface data. We verify the algorithm performance on a synthetic data set with cochlear surface subsets. In addition, we perform an experimental study with four experts in 23 human cochlea CT data sets to compare the automated detection with the manually found axes. Axes found from co-registered high resolution \(\upmu \)CT scans are used for reference. Our experiments show that the algorithm reduces the alignment error providing more reliable modiolar axis detection for clinical and research applications.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Verbist, B.M., et al.: Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea. Otol. Neurotol. 31(5), 722–730 (2010)CrossRef Verbist, B.M., et al.: Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea. Otol. Neurotol. 31(5), 722–730 (2010)CrossRef
3.
Zurück zum Zitat Demarcy, T., et al.: Automated analysis of human cochlea shape variability from seg-mented \(\upmu \)CT images. Comput. Med. Imaging Graph. 59, 1–12 (2017)CrossRef Demarcy, T., et al.: Automated analysis of human cochlea shape variability from seg-mented \(\upmu \)CT images. Comput. Med. Imaging Graph. 59, 1–12 (2017)CrossRef
4.
Zurück zum Zitat Yoo, S.K., Wang, G., Rubinstein, J.T., Vannier, M.W.: Three-dimensional geometric modeling of the cochlea using helico-spiral approximation. IEEE Trans. Biomed. Eng. 47(10), 1392–1402 (2000)CrossRef Yoo, S.K., Wang, G., Rubinstein, J.T., Vannier, M.W.: Three-dimensional geometric modeling of the cochlea using helico-spiral approximation. IEEE Trans. Biomed. Eng. 47(10), 1392–1402 (2000)CrossRef
5.
Zurück zum Zitat Hofer, M., Odehnal, B., Pottmann, H., Steiner, T., Wallner, J.: 3D shape recognition and reconstruction based on line element geometry. In: 10th International Conference on Computer Vision, pp. 1532–1538. IEEE, Beijing (2005) Hofer, M., Odehnal, B., Pottmann, H., Steiner, T., Wallner, J.: 3D shape recognition and reconstruction based on line element geometry. In: 10th International Conference on Computer Vision, pp. 1532–1538. IEEE, Beijing (2005)
6.
Zurück zum Zitat Andrews, J., Séquin, C.H.: Generalized, basis-independent kinematic surface fitting. Comput.-Aided Des. 45(3), 615–620 (2013)CrossRef Andrews, J., Séquin, C.H.: Generalized, basis-independent kinematic surface fitting. Comput.-Aided Des. 45(3), 615–620 (2013)CrossRef
7.
Zurück zum Zitat Chernov, N.: On the convergence of fitting algorithms in computer vision. J. Math. Imaging Vis. 27, 231–239 (2007)MathSciNetCrossRef Chernov, N.: On the convergence of fitting algorithms in computer vision. J. Math. Imaging Vis. 27, 231–239 (2007)MathSciNetCrossRef
9.
Zurück zum Zitat Pietsch, M., et al.: Spiral form of the human cochlea results from spatial constraints. Sci. Rep. 7, 7500 (2017)CrossRef Pietsch, M., et al.: Spiral form of the human cochlea results from spatial constraints. Sci. Rep. 7, 7500 (2017)CrossRef
10.
Zurück zum Zitat Bates, D., Mächler, M., Bolker, B., Walker, S.: Fitting linear mixed-effects models using lme4. J. Stat. Softw. 67(1), 1–48 (2015)CrossRef Bates, D., Mächler, M., Bolker, B., Walker, S.: Fitting linear mixed-effects models using lme4. J. Stat. Softw. 67(1), 1–48 (2015)CrossRef
Metadaten
Titel
Robust Cochlear Modiolar Axis Detection in CT
verfasst von
Wilhelm Wimmer
Clair Vandersteen
Nicolas Guevara
Marco Caversaccio
Hervé Delingette
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-030-32254-0_1