Skip to main content

2022 | OriginalPaper | Buchkapitel

Seismic Performance of CFRP Jacketed Sub-standard RC Columns Under High Axial Stress and Shear Demand

verfasst von : Merve Nur Demir, Ugur Demir, Cem Demir, Alper Ilki

Erschienen in: 10th International Conference on FRP Composites in Civil Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In the last decades, lessons learnt from the major earthquakes, that occurred in many countries, brought revisions in prevailing seismic design codes. As a consequence of this phenomenon, the current building stock in Turkey is mainly comprised of reinforced concrete (RC) buildings which were designed according to different seismic design codes. The presented paper is a component of a comprehensive investigation which containing three variables i) high axial load ratio defined as axial load divided by the axial capacity, ii) high shear demand defined as the ratio of shear demand at flexural yielding to shear resistance and iii) low transverse reinforcement ratio owing to large spacing among steel reinforcements. Thus, a total of four full-scale square RC columns comprised of i) one column designed to comply with the former Turkish Seismic Design Code (TSDC, 1975) and ii) three columns which are not compliant to any design codes (referred as sub-standard), were tested under high axial load ratio, 0.4 for code-conforming and 0.75 for sub-standard columns, combined with reversed cyclic lateral loading. The columns were also designed to have high shear demand in the order of 0.62 and 0.80 for bare sub-standard according to ACI 318 (2019) and TBEC (2018) design codes as sometimes observed in existing sub-standard structures. In addition to that, the ratio of shear demand for the code-conforming column is calculated 0.43 and 0.50 as per design codes, respectively. Besides, the ratio of transverse reinforcement area to the minimum required transverse reinforcement area was 0.19 and 0.77 for sub-standard columns according to ACI 318 (2019) and TBEC (2018), respectively. For the code-conforming column, the aforementioned ratio was 0.57 and 1.32 for both design codes, in the same manner. One of the sub-standard columns was kept as a reference column while the other two of them have been externally jacketed with one layer or two layers of carbon fiber-reinforced polymer (CFRP) sheets. Test results pointed out that the confinement provided by CFRP jacketing has remarkably improved the performance of seismically-deficient RC columns subjected to high axial compression under high shear demand in terms of lateral load capacity and ductility. The experimental results were also supplemented with theoretical work to evaluate the effects of CFRP jacketing on the seismic behavior of sub-standard RC columns .

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat ACI Committee 374 (2013) Guide for testing reinforced concrete structural elements under slowly applied simulated seismic loads. ACI 374.2R-13. Farmington Hills ACI Committee 374 (2013) Guide for testing reinforced concrete structural elements under slowly applied simulated seismic loads. ACI 374.2R-13. Farmington Hills
Zurück zum Zitat ACI Committee 318 (2014) Building code requirements for structural concrete. ACI 318R-19. Farmington Hills ACI Committee 318 (2014) Building code requirements for structural concrete. ACI 318R-19. Farmington Hills
Zurück zum Zitat Bousias SN, Triantafillou TC, Fardis MN, Spathis LA, O’Regan BA (2004) Fiber-reinforced polymer retrofitting of rectangular reinforced concrete columns with or without corrosion. ACI Struct J 101(4):512–520 Bousias SN, Triantafillou TC, Fardis MN, Spathis LA, O’Regan BA (2004) Fiber-reinforced polymer retrofitting of rectangular reinforced concrete columns with or without corrosion. ACI Struct J 101(4):512–520
Zurück zum Zitat Chadwell CB, Imbsen RA (2004) XTRACT: A Tool for axial force-ultimate curvature interactions. Structures:1–9 Chadwell CB, Imbsen RA (2004) XTRACT: A Tool for axial force-ultimate curvature interactions. Structures:1–9
Zurück zum Zitat Cui C, Sheikh A (2010) Experimental study of normal and high strength concrete confined with fiber-reinforced polymers. J Compos Constr 14(5):553–561CrossRef Cui C, Sheikh A (2010) Experimental study of normal and high strength concrete confined with fiber-reinforced polymers. J Compos Constr 14(5):553–561CrossRef
Zurück zum Zitat De Luca A, Nardone F, Matta F, Nanni A, Lignola GP, Prota A (2011) Structural evaluation of full-scale FRP-confined reinforced concrete columns. J Compos Constr 15(1):112–123CrossRef De Luca A, Nardone F, Matta F, Nanni A, Lignola GP, Prota A (2011) Structural evaluation of full-scale FRP-confined reinforced concrete columns. J Compos Constr 15(1):112–123CrossRef
Zurück zum Zitat Demir U, Ispir M, Sahinkaya Y, Arslan G, Ilki A (2019) Axial behavior of noncircular high-performance fiber-reinforced cementitious composite members externally jacketed by CFRP sheets. J Compos Constr 23(4):04019022CrossRef Demir U, Ispir M, Sahinkaya Y, Arslan G, Ilki A (2019) Axial behavior of noncircular high-performance fiber-reinforced cementitious composite members externally jacketed by CFRP sheets. J Compos Constr 23(4):04019022CrossRef
Zurück zum Zitat Di Ludovico M, Verderame G, Prota A, Manfredi G, Cosenza E (2013) Experimental behavior of nonconforming RC columns with plain bars under constant axial load and biaxial bending. J Struct Eng 139:897–914CrossRef Di Ludovico M, Verderame G, Prota A, Manfredi G, Cosenza E (2013) Experimental behavior of nonconforming RC columns with plain bars under constant axial load and biaxial bending. J Struct Eng 139:897–914CrossRef
Zurück zum Zitat Fernandes C, Melo J, Varum H, Costa A (2013) Cyclic behavior of substandard reinforced concrete beam-column joints with plain bars. ACI Struct J:137–147 Fernandes C, Melo J, Varum H, Costa A (2013) Cyclic behavior of substandard reinforced concrete beam-column joints with plain bars. ACI Struct J:137–147
Zurück zum Zitat Ghatte FH, Comert M, Demir C, Akbaba M, Ilki A (2019) Seismic retrofit of full-scale substandard extended rectangular RC columns through CFRP jacketing: test results and design recommendations. J Compos Constr 23(1):04018071CrossRef Ghatte FH, Comert M, Demir C, Akbaba M, Ilki A (2019) Seismic retrofit of full-scale substandard extended rectangular RC columns through CFRP jacketing: test results and design recommendations. J Compos Constr 23(1):04018071CrossRef
Zurück zum Zitat Inci P, Goksu C, Ilki A, Kumbasar N (2013) Effects of reinforcement corrosion on the performance of RC frame buildings subjected to seismic actions. J Perform Constr Facil 27:683–696CrossRef Inci P, Goksu C, Ilki A, Kumbasar N (2013) Effects of reinforcement corrosion on the performance of RC frame buildings subjected to seismic actions. J Perform Constr Facil 27:683–696CrossRef
Zurück zum Zitat Ilki A, Kumbasar N, Koc V (2004) Low strength concrete members externally confined with FRP sheets. Struct Eng Mech 18(2):167–194CrossRef Ilki A, Kumbasar N, Koc V (2004) Low strength concrete members externally confined with FRP sheets. Struct Eng Mech 18(2):167–194CrossRef
Zurück zum Zitat Ilki A, Peker O, Karamuk E, Demir C, Kumbasar N (2008) FRP retrofit of low and medium strength circular and rectangular reinforced concrete columns. J Mater Civ Eng 20(2):169–188CrossRef Ilki A, Peker O, Karamuk E, Demir C, Kumbasar N (2008) FRP retrofit of low and medium strength circular and rectangular reinforced concrete columns. J Mater Civ Eng 20(2):169–188CrossRef
Zurück zum Zitat Ilki A, Demir C, Bedirhanoglu I, Kumbasar N (2009) Seismic retrofit of brittle and low strength RC columns using fiber reinforced polymer and cementitious composites. Adv Struct Eng 12(3):325–347CrossRef Ilki A, Demir C, Bedirhanoglu I, Kumbasar N (2009) Seismic retrofit of brittle and low strength RC columns using fiber reinforced polymer and cementitious composites. Adv Struct Eng 12(3):325–347CrossRef
Zurück zum Zitat Iacobucci RD, Sheikh SA, Bayrak O (2003) Retrofit of square concrete columns with carbon fiber-reinforced polymer for seismic resistance. ACI Struct J 100(6):785–794 Iacobucci RD, Sheikh SA, Bayrak O (2003) Retrofit of square concrete columns with carbon fiber-reinforced polymer for seismic resistance. ACI Struct J 100(6):785–794
Zurück zum Zitat Matamaros BA, Matchulat L, Woods C (2008) Axial load failure of shear critical columns subjected to high levels of axial load. In: 14th World Conference on Earthquake Engineering (WCEE), China Matamaros BA, Matchulat L, Woods C (2008) Axial load failure of shear critical columns subjected to high levels of axial load. In: 14th World Conference on Earthquake Engineering (WCEE), China
Zurück zum Zitat Ozbakkaloglu T, Akin E (2012) Behavior of FRP-confined normal and high-strength concrete under cyclic axial compression. J Compos Constr 16(4):451–463CrossRef Ozbakkaloglu T, Akin E (2012) Behavior of FRP-confined normal and high-strength concrete under cyclic axial compression. J Compos Constr 16(4):451–463CrossRef
Zurück zum Zitat Ozcan O, Binici B, Ozcebe G (2010) Seismic strengthening of rectangular reinforced concrete columns using fiber reinforced polymers. Eng Struct 32(4):964–973CrossRef Ozcan O, Binici B, Ozcebe G (2010) Seismic strengthening of rectangular reinforced concrete columns using fiber reinforced polymers. Eng Struct 32(4):964–973CrossRef
Zurück zum Zitat Paulay T, Priestley MJN (1992) Seismic design of reinforced concrete and masonry buildings. John Wiley & Sons Inc., New York, NY, pp 137–142CrossRef Paulay T, Priestley MJN (1992) Seismic design of reinforced concrete and masonry buildings. John Wiley & Sons Inc., New York, NY, pp 137–142CrossRef
Zurück zum Zitat Saatcioglu M, Razvi SR (1992) Strength and ductility of confined concrete. J Struct Eng 118(6):1590–1607CrossRef Saatcioglu M, Razvi SR (1992) Strength and ductility of confined concrete. J Struct Eng 118(6):1590–1607CrossRef
Zurück zum Zitat Seyhan EC, Goksu C, Uzunhasanoglu A, Ilki A (2015) Seismic behavior of substandard RC columns retrofitted with embedded aramid fiber reinforced polymer (AFRP) reinforcement. Polymers 7(12):2535–2557CrossRef Seyhan EC, Goksu C, Uzunhasanoglu A, Ilki A (2015) Seismic behavior of substandard RC columns retrofitted with embedded aramid fiber reinforced polymer (AFRP) reinforcement. Polymers 7(12):2535–2557CrossRef
Zurück zum Zitat Shahawy M, Mirmiran A, Beitelmann T (2000) Tests and modeling of carbon-wrapped concrete columns. Compos B 31(6–7):471–480CrossRef Shahawy M, Mirmiran A, Beitelmann T (2000) Tests and modeling of carbon-wrapped concrete columns. Compos B 31(6–7):471–480CrossRef
Zurück zum Zitat Wang D, Huang L, Yu T, Wang Z (2017) Seismic performance of CFRP-retrofitted large-scale square RC columns with high axial compression ratios. J Compos Constr, ASCE Wang D, Huang L, Yu T, Wang Z (2017) Seismic performance of CFRP-retrofitted large-scale square RC columns with high axial compression ratios. J Compos Constr, ASCE
Zurück zum Zitat Xiao Y, Wu H (2000) Compressive behavior of concrete confined by carbon-fiber-composite jackets. J Mater Civ Eng 12(2):139–146CrossRef Xiao Y, Wu H (2000) Compressive behavior of concrete confined by carbon-fiber-composite jackets. J Mater Civ Eng 12(2):139–146CrossRef
Metadaten
Titel
Seismic Performance of CFRP Jacketed Sub-standard RC Columns Under High Axial Stress and Shear Demand
verfasst von
Merve Nur Demir
Ugur Demir
Cem Demir
Alper Ilki
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-88166-5_111