Abstract

Purpose

We propose a novel framework for enhancement and localization of steeply inserted hand-held needles under in-plane 2D ultrasound guidance.

Methods

Depth-dependent attenuation and non-axial specular reflection hinder visibility of steeply inserted needles. Here, we model signal transmission maps representative of the attenuation probability within the image domain. The maps are employed in a contextual regularization framework to recover needle shaft and tip information. The needle tip is automatically localized by line-fitting along the local-phase-directed trajectory, followed by statistical optimization.

Results

The proposed method was tested on 300 ex vivo ultrasound scans collected during insertion of an epidural needle into freshly excised porcine and bovine tissue. A tip localization accuracy of \(0.55\pm 0.06\,\hbox {mm}\) was achieved.

Conclusion

The proposed method could be useful in challenging procedures where needle shaft and tip are inconspicuous. Improved needle localization results compared to previously proposed methods suggest that the proposed method is promising for further clinical evaluation.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Khati N, Gorodenker J, Hill M (2011) Ultrasound-guided biopsies of the abdomen. Ultrasound Q 27(4):255–268CrossRefPubMed Khati N, Gorodenker J, Hill M (2011) Ultrasound-guided biopsies of the abdomen. Ultrasound Q 27(4):255–268CrossRefPubMed
2.
Zurück zum Zitat Korbe S, Udoji E, Ness T, Udoji M (2015) Ultrasound-guided interventional procedures for chronic pain management. Pain Manag 5(6):466–482CrossRef Korbe S, Udoji E, Ness T, Udoji M (2015) Ultrasound-guided interventional procedures for chronic pain management. Pain Manag 5(6):466–482CrossRef
3.
Zurück zum Zitat Prasad N, Kumar S, Manjunath R, Bhadauria D, Kaul A, Sharma R, Gupta A, Lal H, Jain M, Agrawal V (2015) Real-time ultrasound-guided percutaneous renal biopsy with needle guide by nephrologists decreases post-biopsy complications. Clin Kidney J 8(2):151–156CrossRefPubMedPubMedCentral Prasad N, Kumar S, Manjunath R, Bhadauria D, Kaul A, Sharma R, Gupta A, Lal H, Jain M, Agrawal V (2015) Real-time ultrasound-guided percutaneous renal biopsy with needle guide by nephrologists decreases post-biopsy complications. Clin Kidney J 8(2):151–156CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Krücker J, Xu S, Glossop N, Viswana A, Borgert J, Schulz H, Wood BJ (2007) Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy. Vasc Interv Radiol 18(9):1141–1150CrossRef Krücker J, Xu S, Glossop N, Viswana A, Borgert J, Schulz H, Wood BJ (2007) Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy. Vasc Interv Radiol 18(9):1141–1150CrossRef
5.
Zurück zum Zitat Stolka PJ, Foroughi P, Rendina M, Weiss CR, Hager GD, Boctor EM (2014) Needle guidance using handheld stereo vision and projection for ultrasound-based interventions. Med Image Comput Comput Assist Interv 17(Pt. 2):684–691PubMedPubMedCentral Stolka PJ, Foroughi P, Rendina M, Weiss CR, Hager GD, Boctor EM (2014) Needle guidance using handheld stereo vision and projection for ultrasound-based interventions. Med Image Comput Comput Assist Interv 17(Pt. 2):684–691PubMedPubMedCentral
6.
Zurück zum Zitat Lu H, Li J, Lu Q, Bharat S, Erkamp R, Chen B, Drysdale J, Vignon F, Jain A (2014) A new sensor technology for 2D ultrasound-guided needle tracking. Med Image Comput Comput Assist Interv 17(Pt. 2):389–396PubMed Lu H, Li J, Lu Q, Bharat S, Erkamp R, Chen B, Drysdale J, Vignon F, Jain A (2014) A new sensor technology for 2D ultrasound-guided needle tracking. Med Image Comput Comput Assist Interv 17(Pt. 2):389–396PubMed
7.
Zurück zum Zitat Ameri G, Son J, Lian J, Foster FS, Ganapathy S, Peters TM (2017) Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery. In: Proceedings of the SPIE medical imaging: ultrasonic imaging and tomography, p 10139 Ameri G, Son J, Lian J, Foster FS, Ganapathy S, Peters TM (2017) Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery. In: Proceedings of the SPIE medical imaging: ultrasonic imaging and tomography, p 10139
8.
Zurück zum Zitat Xia W, West S, Finlay M, Mari J, Ourselin S, David A, Desjardins A (2017) Looking beyond the imaging plane: 3D needle tracking with a linear array ultrasound probe. Sci Rep 7(1):3674CrossRefPubMedPubMedCentral Xia W, West S, Finlay M, Mari J, Ourselin S, David A, Desjardins A (2017) Looking beyond the imaging plane: 3D needle tracking with a linear array ultrasound probe. Sci Rep 7(1):3674CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Mathiassen K, Dall’Alba D, Muradore R, Fiorini P, Elle O (2017) Robust real-time needle tracking in 2-D ultrasound images using statistical filtering. IEEE Trans Control Syst Techn 25(3):966–978CrossRef Mathiassen K, Dall’Alba D, Muradore R, Fiorini P, Elle O (2017) Robust real-time needle tracking in 2-D ultrasound images using statistical filtering. IEEE Trans Control Syst Techn 25(3):966–978CrossRef
10.
Zurück zum Zitat Beigi P, Rohling R, Salcudean S, Ng G (2016) Spectral analysis of the tremor motion for needle detection in curvilinear ultrasound via spatiotemporal linear sampling. Int J Comput Assist Radiol Surg 11(6):1183–1192CrossRefPubMed Beigi P, Rohling R, Salcudean S, Ng G (2016) Spectral analysis of the tremor motion for needle detection in curvilinear ultrasound via spatiotemporal linear sampling. Int J Comput Assist Radiol Surg 11(6):1183–1192CrossRefPubMed
11.
Zurück zum Zitat Hatt CR, Ng G, Parthasarathy V (2015) Enhanced needle localization in ultrasound using beam steering and learning-based segmentation. Comput Med Imag Gr 41:46–54CrossRef Hatt CR, Ng G, Parthasarathy V (2015) Enhanced needle localization in ultrasound using beam steering and learning-based segmentation. Comput Med Imag Gr 41:46–54CrossRef
12.
Zurück zum Zitat Hacihaliloglu I, Beigi P, Ng G, Rohling RN, Salcudean S, Abolmaesumi P (2015) Projection-based phase features for localization of a needle tip in 2D curvilinear ultrasound. Med Image Comput Comput Assist Interv. Springer LNCS, 9349:347–354 Hacihaliloglu I, Beigi P, Ng G, Rohling RN, Salcudean S, Abolmaesumi P (2015) Projection-based phase features for localization of a needle tip in 2D curvilinear ultrasound. Med Image Comput Comput Assist Interv. Springer LNCS, 9349:347–354
13.
Zurück zum Zitat Kuang Y, Hilgers A, Sadiq M, Cochran S, Corner G, Huang Z (2016) Modelling and characterization of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy. Ultrasonics 69:38–46CrossRefPubMed Kuang Y, Hilgers A, Sadiq M, Cochran S, Corner G, Huang Z (2016) Modelling and characterization of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy. Ultrasonics 69:38–46CrossRefPubMed
14.
Zurück zum Zitat Mwikirize C, Nosher JL, Hacihaliloglu I (2016) Enhancement of needle tip and shaft from 2D ultrasound using signal transmission maps. Med Image Comput Comput Assist Interv, Springer LNCS 9900:362–369 Mwikirize C, Nosher JL, Hacihaliloglu I (2016) Enhancement of needle tip and shaft from 2D ultrasound using signal transmission maps. Med Image Comput Comput Assist Interv, Springer LNCS 9900:362–369
15.
Zurück zum Zitat Karamalis A, Wein W, Klein T, Navab N (2012) Ultrasound confidence maps using random walks. Med Image Anal 16(6):1101–1112CrossRefPubMed Karamalis A, Wein W, Klein T, Navab N (2012) Ultrasound confidence maps using random walks. Med Image Anal 16(6):1101–1112CrossRefPubMed
16.
Zurück zum Zitat Grady L (2006) Random walks for image segmentation. IEEE Trans Pattern Anal Mach Intell 28(11):17681783CrossRef Grady L (2006) Random walks for image segmentation. IEEE Trans Pattern Anal Mach Intell 28(11):17681783CrossRef
17.
Zurück zum Zitat Tikhonov AN (1963) On the solution of ill-posed problems and the method of regularization. Doklady Akademii Nauk SSSR 151:501–504 Tikhonov AN (1963) On the solution of ill-posed problems and the method of regularization. Doklady Akademii Nauk SSSR 151:501–504
18.
Zurück zum Zitat Chan T, Esedoglu S (2004) Aspects of Total Variation Regularized \(\text{L}_{1}\) Function Approximation. Technical report, University of California at Los Angeles Chan T, Esedoglu S (2004) Aspects of Total Variation Regularized \(\text{L}_{1}\) Function Approximation. Technical report, University of California at Los Angeles
19.
Zurück zum Zitat Kirsch R (1971) Computer determination of the constituent structure of biological images. Comput Biomed Res 4:315–328CrossRefPubMed Kirsch R (1971) Computer determination of the constituent structure of biological images. Comput Biomed Res 4:315–328CrossRefPubMed
20.
Zurück zum Zitat Meng G, Wang Y, Duan J, Xiang S, Pan C (2013) Efficient Image Dehazing with Boundary Constraint and Contextual Regularization. In: IEEE international conference on computer vision, pp 617–624 Meng G, Wang Y, Duan J, Xiang S, Pan C (2013) Efficient Image Dehazing with Boundary Constraint and Contextual Regularization. In: IEEE international conference on computer vision, pp 617–624
21.
Zurück zum Zitat Torr PHS, Zisserman A (2000) MLESAC: a new robust estimator with application to estimating image geometry. J Comput Vis Image Und 78(1):138–156CrossRef Torr PHS, Zisserman A (2000) MLESAC: a new robust estimator with application to estimating image geometry. J Comput Vis Image Und 78(1):138–156CrossRef
Metadaten
Titel
Signal attenuation maps for needle enhancement and localization in 2D ultrasound
verfasst von
Cosmas Mwikirize
John L. Nosher
Ilker Hacihaliloglu
Publikationsdatum
02.01.2018
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 3/2018
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1698-y

Weitere Artikel der Ausgabe 3/2018

International Journal of Computer Assisted Radiology and Surgery 3/2018 Zur Ausgabe

Premium Partner