Skip to main content
Erschienen in: Fire Technology 4/2014

01.07.2014

Study on Installation of Wire Netting with Intumescent Coating at Openings of Buildings to Reduce Fire Spread by Radiation

verfasst von: Meng-Feng Hung, Ying-Ji Chuang, Ching-Yuan Lin

Erschienen in: Fire Technology | Ausgabe 4/2014

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This study focuses on a new device that can reduce radiation heat at the openings of buildings. Intumescent coating is sprayed on wire netting affixed to the open spaces in the external wall of a building to reduce radiation heat and fire spread. This study uses a 1.2 m × 1.2 m × 1.2 m furnace to conduct fire-resistance tests according to the ISO 834-1 standard (the standard 1 h temperature rise curve and the furnace pressure). The study variables include wire netting with different mesh numbers (mesh widths) and wire netting with different coating thicknesses. The results from six sets of fire tests show that under the same coating thickness, less radiation heat is generated for a larger mesh number (i.e., smaller mesh width). Under the same mesh number for the wire netting, less radiation heat is generated for a larger coating thickness. At distances of 50 cm, 100 cm, and 150 cm from a fire source with a temperature of 945°C, the radiation heat calculated based on the theory is 6.9 W/cm2. This study proves that the radiation heat can be dropped to 0.48 W/cm2 with the installation of intumescent-coated wire netting, and that this type of netting can effectively prevent fire spreading by radiation.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Building Research Establishment (1991) BRE report: external fire spread: building separation and boundary distances. BRE, Borehamwood Building Research Establishment (1991) BRE report: external fire spread: building separation and boundary distances. BRE, Borehamwood
2.
Zurück zum Zitat Butcher EG, Parnell AC (1983) Designing for fire safety. Wiley, New York Butcher EG, Parnell AC (1983) Designing for fire safety. Wiley, New York
3.
Zurück zum Zitat Association for Fire Science and Engineering (2002) Fire and architecture. Kyoritsu Shuppan Co., Japan Association for Fire Science and Engineering (2002) Fire and architecture. Kyoritsu Shuppan Co., Japan
4.
Zurück zum Zitat Takeyosi T (1993) Guide of fire safety engineering in building. Architectural Institute of Japan, Japan Takeyosi T (1993) Guide of fire safety engineering in building. Architectural Institute of Japan, Japan
5.
Zurück zum Zitat Howell, JR (1983) A catalog of radiation configuration factors. McGraw-Hill, New York Howell, JR (1983) A catalog of radiation configuration factors. McGraw-Hill, New York
6.
Zurück zum Zitat Chuang YJ, Huang CH, Chen PH, Tang CH, Lin, CY (2005) Consideration of safe distance of standard fire test furnace of building elements in laboratory. J Appl Fire Sci 14:125–135CrossRef Chuang YJ, Huang CH, Chen PH, Tang CH, Lin, CY (2005) Consideration of safe distance of standard fire test furnace of building elements in laboratory. J Appl Fire Sci 14:125–135CrossRef
7.
Zurück zum Zitat Wong LT, Yuen WW (2002) Safety consideration of fire shutter in large building space. J Appl Fire Sci 11:195–208CrossRef Wong LT, Yuen WW (2002) Safety consideration of fire shutter in large building space. J Appl Fire Sci 11:195–208CrossRef
8.
Zurück zum Zitat Weber RO (1989) Analytical models for fire spread due to radiation. Combust Flame 78:398–408CrossRef Weber RO (1989) Analytical models for fire spread due to radiation. Combust Flame 78:398–408CrossRef
9.
Zurück zum Zitat Silvani X, Morandini F (2009) Fire spread experiments in the field: temperature and heat fluxes measurements. Fire Saf J 44:279–285CrossRef Silvani X, Morandini F (2009) Fire spread experiments in the field: temperature and heat fluxes measurements. Fire Saf J 44:279–285CrossRef
10.
Zurück zum Zitat Esfahani JA, Sousa A (1999) Ignition of epoxy by a high radiation source. A numerical study. Int J Therm Sci 38:315–323CrossRef Esfahani JA, Sousa A (1999) Ignition of epoxy by a high radiation source. A numerical study. Int J Therm Sci 38:315–323CrossRef
11.
Zurück zum Zitat ISO (1999) Fire-resistance tests—elements of building construction. Part 1: general. ISO, Geneva ISO (1999) Fire-resistance tests—elements of building construction. Part 1: general. ISO, Geneva
12.
Zurück zum Zitat Chuang YJ, Hung YC, Lin CY (2009) Fire tests to study heat insulation scenario of galvanized rolling shutters sprayed with intumescent coatings. Mater Des 30:2576–2583CrossRef Chuang YJ, Hung YC, Lin CY (2009) Fire tests to study heat insulation scenario of galvanized rolling shutters sprayed with intumescent coatings. Mater Des 30:2576–2583CrossRef
13.
Zurück zum Zitat Rhys JA (1980) Intumescent coatings and their uses. Fire Mater 4:154–156CrossRef Rhys JA (1980) Intumescent coatings and their uses. Fire Mater 4:154–156CrossRef
14.
Zurück zum Zitat Deogon M, Hall R, Socrates G (1988) A simple theoretical model for intumescent paints. Constr Build Mater 2:92–95CrossRef Deogon M, Hall R, Socrates G (1988) A simple theoretical model for intumescent paints. Constr Build Mater 2:92–95CrossRef
15.
Zurück zum Zitat Bailey C (2004) Indicative fire tests to investigate the behavior of cellular beams protected with intumescent coatings. Fire Saf J 39:689–709CrossRef Bailey C (2004) Indicative fire tests to investigate the behavior of cellular beams protected with intumescent coatings. Fire Saf J 39:689–709CrossRef
16.
Zurück zum Zitat Gu JW, Zhang GC, Dong SL, Zhang QY, Kong J (2007) Study on preparation and fire-retardant mechanism analysis of intumescent flame-retardant coatings. Surf Coat Technol 201:7835–7841CrossRef Gu JW, Zhang GC, Dong SL, Zhang QY, Kong J (2007) Study on preparation and fire-retardant mechanism analysis of intumescent flame-retardant coatings. Surf Coat Technol 201:7835–7841CrossRef
17.
Zurück zum Zitat Wang G, Yang J (2010) Influences of binder on fire protection and anticorrosion properties of intumescent fire resistive coating for steel structure. Surf Coat Technol 204:1186–1192CrossRef Wang G, Yang J (2010) Influences of binder on fire protection and anticorrosion properties of intumescent fire resistive coating for steel structure. Surf Coat Technol 204:1186–1192CrossRef
18.
Zurück zum Zitat CNS (2000) Fire-retardant paints for buildings. CNS, Taiwan CNS (2000) Fire-retardant paints for buildings. CNS, Taiwan
Metadaten
Titel
Study on Installation of Wire Netting with Intumescent Coating at Openings of Buildings to Reduce Fire Spread by Radiation
verfasst von
Meng-Feng Hung
Ying-Ji Chuang
Ching-Yuan Lin
Publikationsdatum
01.07.2014
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 4/2014
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-012-0310-9

Weitere Artikel der Ausgabe 4/2014

Fire Technology 4/2014 Zur Ausgabe