The effect of antenna polarization and body morphology on the measurement uncertainty of a wearable multi-band distributed exposure meter

verfasst von: Reza Aminzadeh, Arno Thielens, Sam Agneessens, Patrick Van Torre, Matthias Van den Bossche, Stefan Dongus, Marloes Eeftens, Anke Huss, Roel Vermeulen, René de Seze, Paul Mazet, Elisabeth Cardis, Hendrik Rogier, Martin Röösli, Luc Martens, Wout Joseph

Erschienen in: Annals of Telecommunications | Ausgabe 1-2/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This paper studies the effect of antenna polarization on measurement uncertainty of a multi-band body-worn distributed exposure meter (BWDM). The BWDM is a device for assessing electromagnetic fields in real environments accurately. The BWDM consists of 8 nodes and is calibrated on the body for simultaneous measurement of the incident power density in four frequency bands. Each node contains an antenna that can have two potential antenna polarizations.The BWDM is calibrated on four human subjects in an anechoic chamber to determine its measurement uncertainty in terms of 68% confidence interval (CI68) of the on-body antenna aperture. The results show that using a fixed polarization of the antennas on body can lead to a different CI68 up to maximum 4.9 dB when worn by another person which is still 9.6 dB lower than the measurement uncertainty of commercial exposure meters.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Eeftens M, Struchen B, Birks LE, Cardis E, Estarlich M, Fernandez MF, Gajšek P., Gallastegi M, Huss A, Kheifets L, Meder IK, Olsen J, Torrent M, Trček T., Valič B., Vermeulen R, Vrijheid M, van Wel L, Guxens M, Röösli M. (2018) Personal exposure to radio-frequency electromagnetic fields in europe: is there a generation gap? Environ Int 121:216. https://doi.org/10.1016/j.envint.2018.09.002 CrossRef Eeftens M, Struchen B, Birks LE, Cardis E, Estarlich M, Fernandez MF, Gajšek P., Gallastegi M, Huss A, Kheifets L, Meder IK, Olsen J, Torrent M, Trček T., Valič B., Vermeulen R, Vrijheid M, van Wel L, Guxens M, Röösli M. (2018) Personal exposure to radio-frequency electromagnetic fields in europe: is there a generation gap? Environ Int 121:216. https://​doi.​org/​10.​1016/​j.​envint.​2018.​09.​002 CrossRef
3.
Zurück zum Zitat Gryz K, Zradziński P, Karpowicz J (2015) The role of the location of personal exposimeters on the human body in their use for assessing exposure to the electromagnetic field in the radiofrequency range 98–2450 MHz and compliance analysis: evaluation by virtual measurements, BioMed research international 2015 Gryz K, Zradziński P, Karpowicz J (2015) The role of the location of personal exposimeters on the human body in their use for assessing exposure to the electromagnetic field in the radiofrequency range 98–2450 MHz and compliance analysis: evaluation by virtual measurements, BioMed research international 2015
4.
Zurück zum Zitat Bolte JF, van der Zande G, Kamer J (2011) Calibration and uncertainties in personal exposure measurements of radiofrequency electromagnetic fields. Bioelectromagnetics 32(8):652CrossRef Bolte JF, van der Zande G, Kamer J (2011) Calibration and uncertainties in personal exposure measurements of radiofrequency electromagnetic fields. Bioelectromagnetics 32(8):652CrossRef
5.
Zurück zum Zitat Thuróczy G, Molnár F, Jánossy G, Nagy N, Kubinyi G, Bakos J, Szabó J (2008) Personal RF exposimetry in urban area. Annals of Telecommunications-annales des télécommunications 63(1-2):87CrossRef Thuróczy G, Molnár F, Jánossy G, Nagy N, Kubinyi G, Bakos J, Szabó J (2008) Personal RF exposimetry in urban area. Annals of Telecommunications-annales des télécommunications 63(1-2):87CrossRef
6.
Zurück zum Zitat Thielens A, Agneessens S, Verloock L, Tanghe E, Rogier H, Martens L, Joseph W (2015) On-body calibration and processing for a combination of two radio-frequency personal exposimeters. Radiat Prot Dosim 163 (1):58CrossRef Thielens A, Agneessens S, Verloock L, Tanghe E, Rogier H, Martens L, Joseph W (2015) On-body calibration and processing for a combination of two radio-frequency personal exposimeters. Radiat Prot Dosim 163 (1):58CrossRef
8.
Zurück zum Zitat Bahillo A, Blas J, Fernández P., Lorenzo RM, Mazuelas S, Abril EJ (2008) E-field assessment errors associated with RF dosemeters for different angles of arrival. Radiat Prot Dosim 132(1):51CrossRef Bahillo A, Blas J, Fernández P., Lorenzo RM, Mazuelas S, Abril EJ (2008) E-field assessment errors associated with RF dosemeters for different angles of arrival. Radiat Prot Dosim 132(1):51CrossRef
9.
Zurück zum Zitat Neubauer G, Cecil S, Giczi W, Petric B, Preiner P, Fröhlich J, Röösli M (2010) The association between exposure determined by radiofrequency personal exposimeters and human exposure: a simulation study. Bioelectromagnetics 31(7):535CrossRef Neubauer G, Cecil S, Giczi W, Petric B, Preiner P, Fröhlich J, Röösli M (2010) The association between exposure determined by radiofrequency personal exposimeters and human exposure: a simulation study. Bioelectromagnetics 31(7):535CrossRef
11.
Zurück zum Zitat López AN, Gonzalez-Rubio J, Montoya JMV, Garde EA (2015) Using multiple exposimeters to evaluate the influence of the body when measuring personal exposition to radio frequency electromagnetic fields, COMPEL. The International Journal for Computation and Mathematics in Electrical and Electronic Engineering 34(4):1063. https://doi.org/10.1108/COMPEL-10-2014-0268 CrossRef López AN, Gonzalez-Rubio J, Montoya JMV, Garde EA (2015) Using multiple exposimeters to evaluate the influence of the body when measuring personal exposition to radio frequency electromagnetic fields, COMPEL. The International Journal for Computation and Mathematics in Electrical and Electronic Engineering 34(4):1063. https://​doi.​org/​10.​1108/​COMPEL-10-2014-0268 CrossRef
12.
Zurück zum Zitat Aminzadeh R, Thielens A, Bamba A, Kone L, Gaillot DP, Lienard M, Martens L, Joseph W (2016) On-body calibration and measurements using personal radiofrequency exposimeters in indoor diffuse and specular environments. Bioelectromagnetics 37(5):298CrossRef Aminzadeh R, Thielens A, Bamba A, Kone L, Gaillot DP, Lienard M, Martens L, Joseph W (2016) On-body calibration and measurements using personal radiofrequency exposimeters in indoor diffuse and specular environments. Bioelectromagnetics 37(5):298CrossRef
13.
Zurück zum Zitat Vanveerdeghem P, Van Torre P, Thielens A, Knockaert J, Joseph W, Rogier H (2015) Compact personal distributed wearable exposimeter. IEEE Sensors J 15(8):4393CrossRef Vanveerdeghem P, Van Torre P, Thielens A, Knockaert J, Joseph W, Rogier H (2015) Compact personal distributed wearable exposimeter. IEEE Sensors J 15(8):4393CrossRef
14.
Zurück zum Zitat Thielens A, Agneessens S, De Clercq H, Lecoutere J, Verloock L, Tanghe E, Aerts S, Puers R, Rogier H, Martens L, Joseph W (2015) On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity. Health Phys 108(4):407CrossRef Thielens A, Agneessens S, De Clercq H, Lecoutere J, Verloock L, Tanghe E, Aerts S, Puers R, Rogier H, Martens L, Joseph W (2015) On-body calibration and measurements using a personal, distributed exposimeter for wireless fidelity. Health Phys 108(4):407CrossRef
15.
Zurück zum Zitat Aminzadeh R, Thielens A, Agneessens S, Van Torre P, Van den Bossche M, Dongus S, Eeftens M, Huss A, Vermeulen R, de Seze R, Mazet P, Cardis E, Rogier H, Röösli M., Martens L, Joseph W (2018) A multi-band body-worn distributed radio-frequency exposure meter: Design, on-body calibration and study of body morphology. Sensors 18(272):1–19. https://doi.org/10.3390/s18010272 Aminzadeh R, Thielens A, Agneessens S, Van Torre P, Van den Bossche M, Dongus S, Eeftens M, Huss A, Vermeulen R, de Seze R, Mazet P, Cardis E, Rogier H, Röösli M., Martens L, Joseph W (2018) A multi-band body-worn distributed radio-frequency exposure meter: Design, on-body calibration and study of body morphology. Sensors 18(272):1–19. https://​doi.​org/​10.​3390/​s18010272
16.
Zurück zum Zitat Thielens A, Vanveerdeghem P, Van Torre P, Gängler S., Röösli M., Rogier H, Martens L, Joseph W (2016) A personal distributed exposimeter: procedure for design, calibration, validation, and application. Sensors 16(2):1–23CrossRef Thielens A, Vanveerdeghem P, Van Torre P, Gängler S., Röösli M., Rogier H, Martens L, Joseph W (2016) A personal distributed exposimeter: procedure for design, calibration, validation, and application. Sensors 16(2):1–23CrossRef
18.
Zurück zum Zitat Agneessens S (2017) Coupled eighth-mode substrate integrated waveguide antenna: Small and wideband with high-body antenna isolation, IEEE Access Agneessens S (2017) Coupled eighth-mode substrate integrated waveguide antenna: Small and wideband with high-body antenna isolation, IEEE Access
19.
Zurück zum Zitat International Commission on Non-ionizing Radiation Protection (ICNIRP) (1998) Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 Hz). Health Phys 74(4):494 International Commission on Non-ionizing Radiation Protection (ICNIRP) (1998) Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 Hz). Health Phys 74(4):494
24.
Zurück zum Zitat Narda Safety Test Solutions. Electric and Magnetic Field Measurement, NBM Series Probes., EF0391: Economical field probe for universal frequency range. 100 kHz - 3 GHz (2016). NBM-Probes: DataSheet Narda Safety Test Solutions. Electric and Magnetic Field Measurement, NBM Series Probes., EF0391: Economical field probe for universal frequency range. 100 kHz - 3 GHz (2016). NBM-Probes: DataSheet
Metadaten
Titel
The effect of antenna polarization and body morphology on the measurement uncertainty of a wearable multi-band distributed exposure meter
verfasst von
Reza Aminzadeh
Arno Thielens
Sam Agneessens
Patrick Van Torre
Matthias Van den Bossche
Stefan Dongus
Marloes Eeftens
Anke Huss
Roel Vermeulen
René de Seze
Paul Mazet
Elisabeth Cardis
Hendrik Rogier
Martin Röösli
Luc Martens
Wout Joseph
Publikationsdatum
11.12.2018
Verlag
Springer International Publishing
Erschienen in
Annals of Telecommunications / Ausgabe 1-2/2019
Print ISSN: 0003-4347
Elektronische ISSN: 1958-9395
DOI
https://doi.org/10.1007/s12243-018-0691-y

Weitere Artikel der Ausgabe 1-2/2019

Annals of Telecommunications 1-2/2019 Zur Ausgabe

Neuer Inhalt