Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 8/2019

23.04.2019 | Original Article

A markerless automatic deformable registration framework for augmented reality navigation of laparoscopy partial nephrectomy

verfasst von: Xiaohui Zhang, Junchen Wang, Tianmiao Wang, Xuquan Ji, Yu Shen, Zhen Sun, Xuebin Zhang

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 8/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose Video see-through augmented reality (VST-AR) navigation for laparoscopic partial nephrectomy (LPN) can enhance intraoperative perception of surgeons by visualizing surgical targets and critical structures of the kidney tissue. Image registration is the main challenge in the procedure. Existing registration methods in laparoscopic navigation systems suffer from limitations such as manual alignment, invasive external marker fixation, relying on external tracking devices with bulky tracking sensors and lack of deformation compensation. To address these issues, we present a markerless automatic deformable registration framework for LPN VST-AR navigation.

Method

Dense stereo matching and 3D reconstruction, automatic segmentation and surface stitching are combined to obtain a larger dense intraoperative point cloud of the renal surface. A coarse-to-fine deformable registration is performed to achieve a precise automatic registration between the intraoperative point cloud and the preoperative model using the iterative closest point algorithm followed by the coherent point drift algorithm. Kidney phantom experiments and in vivo experiments were performed to evaluate the accuracy and effectiveness of our approach.

Results

The average segmentation accuracy rate of the automatic segmentation was 94.9%. The mean target registration error of the phantom experiments was found to be 1.28 ± 0.68 mm (root mean square error). In vivo experiments showed that tumor location was identified successfully by superimposing the tumor model on the laparoscopic view.

Conclusion

Experimental results have demonstrated that the proposed framework could accurately overlay comprehensive preoperative models on deformable soft organs automatically in a manner of VST-AR without using extra intraoperative imaging modalities and external tracking devices, as well as its potential clinical use.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Dimick JB, Ryan AM (2013) Taking a broader perspective on the benefits of minimally invasive surgery. JAMA Surg 148(7):648CrossRefPubMed Dimick JB, Ryan AM (2013) Taking a broader perspective on the benefits of minimally invasive surgery. JAMA Surg 148(7):648CrossRefPubMed
2.
Zurück zum Zitat Gill IS, Kavoussi LR, Lane BR, Blute ML, Babineau D, Colombo JR Jr, Frank I, Permpongkosol S, Weight CJ, Kaouk JH, Kattan MW, Novick AC (2007) Comparison of 1800 laparoscopic and open partial nephrectomies for single renal tumors. J Urol 178(1):41–46CrossRef Gill IS, Kavoussi LR, Lane BR, Blute ML, Babineau D, Colombo JR Jr, Frank I, Permpongkosol S, Weight CJ, Kaouk JH, Kattan MW, Novick AC (2007) Comparison of 1800 laparoscopic and open partial nephrectomies for single renal tumors. J Urol 178(1):41–46CrossRef
3.
Zurück zum Zitat Stoyanov D, Mylonas GP, Lerotic M, Chung AJ, Yang G (2008) Intra-operative visualizations: perceptual fidelity and human factors. J Disp Technol 4(4):491–501CrossRef Stoyanov D, Mylonas GP, Lerotic M, Chung AJ, Yang G (2008) Intra-operative visualizations: perceptual fidelity and human factors. J Disp Technol 4(4):491–501CrossRef
4.
Zurück zum Zitat Bernhardt S, Nicolau SA, Soler L, Doignon C (2017) The status of augmented reality in laparoscopic surgery as of 2016. Med Image Anal 37:66–90CrossRefPubMed Bernhardt S, Nicolau SA, Soler L, Doignon C (2017) The status of augmented reality in laparoscopic surgery as of 2016. Med Image Anal 37:66–90CrossRefPubMed
5.
Zurück zum Zitat Nicolau S, Soler L, Mutter D, Marescaux J (2011) Augmented reality in laparoscopic surgical oncology. Surg Oncol 20(3):189–201CrossRefPubMed Nicolau S, Soler L, Mutter D, Marescaux J (2011) Augmented reality in laparoscopic surgical oncology. Surg Oncol 20(3):189–201CrossRefPubMed
6.
Zurück zum Zitat Feuerstein M, Mussack T, Heining SM, Navab N (2008) Intraoperative laparoscope augmentation for port placement and resection planning in minimally invasive liver resection. IEEE Trans Med Imaging 27(3):355–369CrossRefPubMed Feuerstein M, Mussack T, Heining SM, Navab N (2008) Intraoperative laparoscope augmentation for port placement and resection planning in minimally invasive liver resection. IEEE Trans Med Imaging 27(3):355–369CrossRefPubMed
7.
Zurück zum Zitat Mountney P, Fallert J, Nicolau S, Soler L, Mewes PW (2014) An augmented reality framework for soft tissue surgery. Med Image Comput Comput Assist Interv 17(1):423–431PubMed Mountney P, Fallert J, Nicolau S, Soler L, Mewes PW (2014) An augmented reality framework for soft tissue surgery. Med Image Comput Comput Assist Interv 17(1):423–431PubMed
8.
Zurück zum Zitat Baumhauer M, Simpfendörfer T, Müller-Stich BP, Teber D, Gutt CN, Rassweiler J, Meinzer H-P, Wolf I (2008) Soft tissue navigation for laparoscopic partial nephrectomy. IJCARS 3(3–4):307–314 Baumhauer M, Simpfendörfer T, Müller-Stich BP, Teber D, Gutt CN, Rassweiler J, Meinzer H-P, Wolf I (2008) Soft tissue navigation for laparoscopic partial nephrectomy. IJCARS 3(3–4):307–314
9.
Zurück zum Zitat Wild E, Teber D, Schmid D, Simpfendörfer T, Müller M, Baranski AC, Kenngott H, Kopka K, Maier-Hein L (2016) Robust augmented reality guidance with fluorescent markers in laparoscopic surgery. IJCARS 11(6):899–907 Wild E, Teber D, Schmid D, Simpfendörfer T, Müller M, Baranski AC, Kenngott H, Kopka K, Maier-Hein L (2016) Robust augmented reality guidance with fluorescent markers in laparoscopic surgery. IJCARS 11(6):899–907
10.
Zurück zum Zitat Bernhardt S, Nicolau SA, Agnus V, Soler L, Doignon C, Marescaux J (2016) Automatic localization of endoscope in intraoperative CT image: a simple approach to augmented reality guidance in laparoscopic surgery. Med Image Anal 30:130–143CrossRefPubMed Bernhardt S, Nicolau SA, Agnus V, Soler L, Doignon C, Marescaux J (2016) Automatic localization of endoscope in intraoperative CT image: a simple approach to augmented reality guidance in laparoscopic surgery. Med Image Anal 30:130–143CrossRefPubMed
12.
Zurück zum Zitat Pessaux P, Diana M, Soler L, Piardi T, Mutter D, Marescaux J (2015) Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy. Langenbeck’s Arch Surg 400(3):381–385CrossRef Pessaux P, Diana M, Soler L, Piardi T, Mutter D, Marescaux J (2015) Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy. Langenbeck’s Arch Surg 400(3):381–385CrossRef
13.
Zurück zum Zitat Souzaki R, Ieiri S, Uemura M, Ohuchida K, Tomikawa M (2013) An augmented reality navigation system for pediatric oncologic surgery based on preoperative CT and MRI images. J Pediatr Surg 48(12):2479–2483CrossRefPubMed Souzaki R, Ieiri S, Uemura M, Ohuchida K, Tomikawa M (2013) An augmented reality navigation system for pediatric oncologic surgery based on preoperative CT and MRI images. J Pediatr Surg 48(12):2479–2483CrossRefPubMed
14.
Zurück zum Zitat Su LM, Vagvolgyi BP, Agarwal R, Reiley CE, Taylor RH, Hager GD (2009) Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration. Urology 73(4):896–900CrossRefPubMed Su LM, Vagvolgyi BP, Agarwal R, Reiley CE, Taylor RH, Hager GD (2009) Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration. Urology 73(4):896–900CrossRefPubMed
15.
Zurück zum Zitat Thompson S, Totz J, Song Y, Johnsen S, Stoyanov D (2015) Accuracy validation of an image guided laparoscopy system for liver resection. Med Imaging 9415:941509-1–941509-12 Thompson S, Totz J, Song Y, Johnsen S, Stoyanov D (2015) Accuracy validation of an image guided laparoscopy system for liver resection. Med Imaging 9415:941509-1–941509-12
16.
Zurück zum Zitat Marzano E, Piardi T, Soler L, Diana M, Mutter D, Marescaux J, Pessaux P (2013) Augmented reality-guided artery-first pancreatico-duodenectomy. J Gastrointest Surg 17(11):1980–1983CrossRefPubMed Marzano E, Piardi T, Soler L, Diana M, Mutter D, Marescaux J, Pessaux P (2013) Augmented reality-guided artery-first pancreatico-duodenectomy. J Gastrointest Surg 17(11):1980–1983CrossRefPubMed
17.
Zurück zum Zitat Puerto Souza GA, Mariottini GL (2013) Toward long-term and accurate augmented-reality display for minimally-invasive surgery. In: ICRA, pp 5384–5389 Puerto Souza GA, Mariottini GL (2013) Toward long-term and accurate augmented-reality display for minimally-invasive surgery. In: ICRA, pp 5384–5389
19.
Zurück zum Zitat Cash DM, Miga MI, Sinha TK, Galloway RL, Chapman WC (2005) Compensating for intraoperative soft-tissue deformations using incomplete surface data and finite elements. IEEE Trans Med Imaging 24(11):1479–1491CrossRefPubMed Cash DM, Miga MI, Sinha TK, Galloway RL, Chapman WC (2005) Compensating for intraoperative soft-tissue deformations using incomplete surface data and finite elements. IEEE Trans Med Imaging 24(11):1479–1491CrossRefPubMed
20.
Zurück zum Zitat Hamarneh G, Amir-Khalili A, Nosrati M, Figueroa I, Kawahara J, Al-Alao O, Peyrat JM, Abi-Nahed J, Al-Ansari A, Abugharbieh R (2014) Towards multi-modal image-guided tumour identification in robot-assisted partial nephrectomy. In: MECBME, pp 159–162. https://doi.org/10.1109/mecbme.2014.6783230 Hamarneh G, Amir-Khalili A, Nosrati M, Figueroa I, Kawahara J, Al-Alao O, Peyrat JM, Abi-Nahed J, Al-Ansari A, Abugharbieh R (2014) Towards multi-modal image-guided tumour identification in robot-assisted partial nephrectomy. In: MECBME, pp 159–162. https://​doi.​org/​10.​1109/​mecbme.​2014.​6783230
22.
Zurück zum Zitat Nakamura K, Naya Y, Zenbutsu S, Araki K, Cho S, Ohta S, Nihei N, Suzuki H, Ichikawa T, Igarashi T (2010) Surgical navigation using three-dimensional computed tomography images fused intraoperatively with live video. J Endourol 24(4):521–524CrossRefPubMed Nakamura K, Naya Y, Zenbutsu S, Araki K, Cho S, Ohta S, Nihei N, Suzuki H, Ichikawa T, Igarashi T (2010) Surgical navigation using three-dimensional computed tomography images fused intraoperatively with live video. J Endourol 24(4):521–524CrossRefPubMed
23.
Zurück zum Zitat Teber D, Guven S, Simpfendörfer T, Baumhauer M, Güven EO, Yencilek F, Gözen AS, Rassweiler J (2009) Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy preliminary in vitro and in vivo results. Eur Urol 56(2):332–338CrossRefPubMed Teber D, Guven S, Simpfendörfer T, Baumhauer M, Güven EO, Yencilek F, Gözen AS, Rassweiler J (2009) Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy preliminary in vitro and in vivo results. Eur Urol 56(2):332–338CrossRefPubMed
24.
Zurück zum Zitat Kong S, Haouchine N, Soares R, Klymchenko A, Andreiuk B, Marques B, Shabat G, Piechaud T, Diana M, Cotin S, Marescaux J (2017) Robust augmented reality registration method for localization of solid organs’ tumors using CT-derived virtual biomechanical model and fluorescent fiducials. Surg Endosc 31(7):2863–2871CrossRefPubMed Kong S, Haouchine N, Soares R, Klymchenko A, Andreiuk B, Marques B, Shabat G, Piechaud T, Diana M, Cotin S, Marescaux J (2017) Robust augmented reality registration method for localization of solid organs’ tumors using CT-derived virtual biomechanical model and fluorescent fiducials. Surg Endosc 31(7):2863–2871CrossRefPubMed
25.
Zurück zum Zitat Wild E, Teber D, Schmid D, Simpfendörfer T, Müller M, Baranski A, Kenngott H, Kopka K, Maier-Hein L (2016) Robust augmented reality guidance with fluorescent markers in laparoscopic surgery. Int J Comput Ass Rad 11(6):899–907 Wild E, Teber D, Schmid D, Simpfendörfer T, Müller M, Baranski A, Kenngott H, Kopka K, Maier-Hein L (2016) Robust augmented reality guidance with fluorescent markers in laparoscopic surgery. Int J Comput Ass Rad 11(6):899–907
26.
Zurück zum Zitat Chang PL, Stoyanov D, Davison AJ, Edwards PE (2013) Real-time dense stereo reconstruction using convex optimisation with a cost-volume for image-guided robotic surgery. MICCAI 8149:42–49 Chang PL, Stoyanov D, Davison AJ, Edwards PE (2013) Real-time dense stereo reconstruction using convex optimisation with a cost-volume for image-guided robotic surgery. MICCAI 8149:42–49
27.
Zurück zum Zitat Totz J, Thompson S, Stoyanov D, Gurusamy K, Davidson BR, Hawkes DJ, Clarkson MJ (2014) Fast semi-dense surface reconstruction from stereoscopic video in laparoscopic surgery. IPCAI 8498:206–215 Totz J, Thompson S, Stoyanov D, Gurusamy K, Davidson BR, Hawkes DJ, Clarkson MJ (2014) Fast semi-dense surface reconstruction from stereoscopic video in laparoscopic surgery. IPCAI 8498:206–215
28.
Zurück zum Zitat Stoyanov D, Darzi A, Yang GZ (2004) Dense 3D depth recovery for soft tissue deformation during robotically assisted laparoscopic surgery. MICCAI 3217:41–48 Stoyanov D, Darzi A, Yang GZ (2004) Dense 3D depth recovery for soft tissue deformation during robotically assisted laparoscopic surgery. MICCAI 3217:41–48
29.
Zurück zum Zitat Chui H, Rangarajan A (2003) A new point matching algorithm for non-rigid registration. Comput Vis Image Und 89(2):114–141CrossRef Chui H, Rangarajan A (2003) A new point matching algorithm for non-rigid registration. Comput Vis Image Und 89(2):114–141CrossRef
30.
Zurück zum Zitat Myronenko A, Song X (2010) Point set registration: coherent point drift. TPAMI 32(12):2262–2275CrossRef Myronenko A, Song X (2010) Point set registration: coherent point drift. TPAMI 32(12):2262–2275CrossRef
31.
Zurück zum Zitat Hirschmuller H (2005) Accurate and efficient stereo processing by semi-global matching and mutual information. CVPR 2:807–814 Hirschmuller H (2005) Accurate and efficient stereo processing by semi-global matching and mutual information. CVPR 2:807–814
32.
Zurück zum Zitat Hirschmuller H (2008) Stereo processing by semiglobal matching and mutual information. IEEE Trans Pattern Anal Mach Intell 30(2):328–341CrossRefPubMed Hirschmuller H (2008) Stereo processing by semiglobal matching and mutual information. IEEE Trans Pattern Anal Mach Intell 30(2):328–341CrossRefPubMed
33.
Zurück zum Zitat Birchfield S, Tomasi C (2002) A pixel dissimilarity measure that is insensitive to image sampling. IEEE Trans Pattern Anal Mach Intell 20(4):401–406CrossRef Birchfield S, Tomasi C (2002) A pixel dissimilarity measure that is insensitive to image sampling. IEEE Trans Pattern Anal Mach Intell 20(4):401–406CrossRef
35.
Zurück zum Zitat Bay H, Ess A, Tuytelaars T, Van Gool L (2008) Speeded-up robust features (SURF). Comput Vis Image Und 110(3):346–359CrossRef Bay H, Ess A, Tuytelaars T, Van Gool L (2008) Speeded-up robust features (SURF). Comput Vis Image Und 110(3):346–359CrossRef
36.
Zurück zum Zitat Fischler M, Bolles R (1981) Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM 24(6):381–395CrossRef Fischler M, Bolles R (1981) Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM 24(6):381–395CrossRef
37.
Zurück zum Zitat Richard H, Andrew Z (2015) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, Cambridge Richard H, Andrew Z (2015) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, Cambridge
38.
Zurück zum Zitat Besl PJ, Mckay ND (1992) A method for registration of 3-d shapes. Proc SPIE Int Soc Opt Eng 14(3):239–256 Besl PJ, Mckay ND (1992) A method for registration of 3-d shapes. Proc SPIE Int Soc Opt Eng 14(3):239–256
40.
Zurück zum Zitat Wang JC, Suenaga H, Hoshi K, Yang LJ, Kobayashi E, Sakuma I, Liao HG (2014) Augmented reality navigation with automatic marker-free image registration using 3-D image overlay for dental surgery. IEEE Trans Biomed Eng 61(4):1295–1304CrossRefPubMed Wang JC, Suenaga H, Hoshi K, Yang LJ, Kobayashi E, Sakuma I, Liao HG (2014) Augmented reality navigation with automatic marker-free image registration using 3-D image overlay for dental surgery. IEEE Trans Biomed Eng 61(4):1295–1304CrossRefPubMed
41.
42.
Zurück zum Zitat Zhang Z (2002) A flexible new technique for camera calibration. TPAMI 22(11):1330–1334CrossRef Zhang Z (2002) A flexible new technique for camera calibration. TPAMI 22(11):1330–1334CrossRef
43.
Zurück zum Zitat Plantefeve R, Haouchine N, Radoux JP, Cotin S (2014) Automatic alignment of pre and intraoperative data using anatomical landmarks for augmented laparoscopic liver surgery. Lecture Notes in Computer Science, vol 8789. Springer, Berlin, pp 58–66 Plantefeve R, Haouchine N, Radoux JP, Cotin S (2014) Automatic alignment of pre and intraoperative data using anatomical landmarks for augmented laparoscopic liver surgery. Lecture Notes in Computer Science, vol 8789. Springer, Berlin, pp 58–66
Metadaten
Titel
A markerless automatic deformable registration framework for augmented reality navigation of laparoscopy partial nephrectomy
verfasst von
Xiaohui Zhang
Junchen Wang
Tianmiao Wang
Xuquan Ji
Yu Shen
Zhen Sun
Xuebin Zhang
Publikationsdatum
23.04.2019
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 8/2019
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-019-01974-6

Weitere Artikel der Ausgabe 8/2019

International Journal of Computer Assisted Radiology and Surgery 8/2019 Zur Ausgabe

Premium Partner