A procedure for evaluation of non-invasive blood pressure simulators

verfasst von: Gregor Geršak, Aleš Žemva, Janko Drnovšek

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 12/2009

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Non-invasive blood pressure (NIBP) simulators are used in clinical environment for quick checks of blood pressure monitors as a part of technical maintenance and health-care quality assurance system. They are also included in various tests within the procedures for testing NIBP monitors. In practice simulators are often subject to mechanical and electromagnetic shocks which could effect their measuring function. Our objective was to design a procedure for testing the reliability and quality of simulators in order to ensure reliable testing of NIBP monitors. Procedure for evaluation of NIBP simulators, consisting of a static and dynamic test, is proposed. Static test consisted of procedures derived from common electro-mechanical manometer calibration, while dynamic test included testing of repeatability of simulator’s output. A commercial simulator was tested. Among others, the results indicated that evaluations of NIBP simulators should be performed regularly with a suitable time interval in order to track the metrological quality of the simulator in time. Acceptance criteria for a reliable simulator in both static and dynamic sense are proposed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Amoore JN, Murray IC (2006) Oscillometric noninvasive blood pressure measurement devices and simulators. J Clin Eng 31(2):85–95 Amoore JN, Murray IC (2006) Oscillometric noninvasive blood pressure measurement devices and simulators. J Clin Eng 31(2):85–95
2.
Zurück zum Zitat Amoore JN, Scott HT (2000) Can simulators evaluate systematic differences between oscillometric non-invasive blood pressure monitors? Blood Press Monit 5:81–89 Amoore JN, Scott HT (2000) Can simulators evaluate systematic differences between oscillometric non-invasive blood pressure monitors? Blood Press Monit 5:81–89
3.
Zurück zum Zitat Amoore JN, Geake WB, Eng B (1997) An evaluation of three oscillometric non-invasive blood pressure simulators. J Clin Eng 22:93–99 Amoore JN, Geake WB, Eng B (1997) An evaluation of three oscillometric non-invasive blood pressure simulators. J Clin Eng 22:93–99
4.
Zurück zum Zitat Amoore JN, Vacherb E, Murray IC et al (2006) Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? Blood Press Monit 11:63–67CrossRef Amoore JN, Vacherb E, Murray IC et al (2006) Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? Blood Press Monit 11:63–67CrossRef
5.
Zurück zum Zitat CEN (1995) EN 1060 non-invasive sphygmomanometers: EN 1060-3 part 3: supplementary requirements for electro-mechanical blood pressure measuring systems. EN 1060-4 part 4: test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. CEN, Brussels CEN (1995) EN 1060 non-invasive sphygmomanometers: EN 1060-3 part 3: supplementary requirements for electro-mechanical blood pressure measuring systems. EN 1060-4 part 4: test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometers. CEN, Brussels
6.
Zurück zum Zitat Davis PD, Dennis JL, Railton R (2004) Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator. J Hum Hypertens 1–7 Davis PD, Dennis JL, Railton R (2004) Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator. J Hum Hypertens 1–7
8.
Zurück zum Zitat Geršak G, Batagelj V, Drnovšek J (2006) Oscillometric virtual instrument for blood pressure measurement. In: IMEKO XVIII World Congress, IV Brazilian congress of metrology, Rio de Janeiro, Brazil, Metrology for a sustainable development, 17–22 September 2006 Geršak G, Batagelj V, Drnovšek J (2006) Oscillometric virtual instrument for blood pressure measurement. In: IMEKO XVIII World Congress, IV Brazilian congress of metrology, Rio de Janeiro, Brazil, Metrology for a sustainable development, 17–22 September 2006
9.
Zurück zum Zitat Gross H, Mieke S, Ulbrich M (1996) An arm phantom: a digital simulation system for testing sphygmomanometers. J Med Eng Technol 20(2):75–83CrossRef Gross H, Mieke S, Ulbrich M (1996) An arm phantom: a digital simulation system for testing sphygmomanometers. J Med Eng Technol 20(2):75–83CrossRef
10.
Zurück zum Zitat International Organization of Legal Metrology OIML (2002) Non-invasive automated sphygmomanometers, International Recommendations OIML R16-2. BIML, Brussels International Organization of Legal Metrology OIML (2002) Non-invasive automated sphygmomanometers, International Recommendations OIML R16-2. BIML, Brussels
11.
Zurück zum Zitat ISO (1995) Guide to expression of uncertainty in measurement. ISO, Geneva ISO (1995) Guide to expression of uncertainty in measurement. ISO, Geneva
13.
Zurück zum Zitat Kaplan NM, Lieberman E (2002) Kaplan’s clinical hypertension, 8th edn. Lippincott Williams & Wilkins, Philadelphia Kaplan NM, Lieberman E (2002) Kaplan’s clinical hypertension, 8th edn. Lippincott Williams & Wilkins, Philadelphia
14.
Zurück zum Zitat Mieke S (1997) Substitution of simulators for human subjects. Blood Press Monit 2:251–256 Mieke S (1997) Substitution of simulators for human subjects. Blood Press Monit 2:251–256
15.
Zurück zum Zitat Ng K-G (1992) Review of methods & simulators for evaluation of noninvasive blood pressure monitors. J Clin Eng 17:469–479 Ng K-G (1992) Review of methods & simulators for evaluation of noninvasive blood pressure monitors. J Clin Eng 17:469–479
16.
Zurück zum Zitat Ng K-G (2000) A simulation-based evaluation of nine oscillometric blood pressure monitors for self-measurement. Blood Press Monit 5:297–322CrossRef Ng K-G (2000) A simulation-based evaluation of nine oscillometric blood pressure monitors for self-measurement. Blood Press Monit 5:297–322CrossRef
17.
Zurück zum Zitat Ng K-G, Small CF (1994) Update on methods & simulators for evaluation of noninvasive blood pressure monitors. J Clin Eng 19:125–134 Ng K-G, Small CF (1994) Update on methods & simulators for evaluation of noninvasive blood pressure monitors. J Clin Eng 19:125–134
18.
Zurück zum Zitat Sims AJ, Reay CA, Bousfield DR et al (2005) Oscillometric blood pressure devices and simulators: measurements of repeatability and differences between models. J Med Eng Technol 29(3):112–118CrossRef Sims AJ, Reay CA, Bousfield DR et al (2005) Oscillometric blood pressure devices and simulators: measurements of repeatability and differences between models. J Med Eng Technol 29(3):112–118CrossRef
19.
Zurück zum Zitat Yarrows AS, Brook RD (2000) Measurement variation among 12 electronic home blood pressure monitors. AJH 13:276–282 Yarrows AS, Brook RD (2000) Measurement variation among 12 electronic home blood pressure monitors. AJH 13:276–282
Metadaten
Titel
A procedure for evaluation of non-invasive blood pressure simulators
verfasst von
Gregor Geršak
Aleš Žemva
Janko Drnovšek
Publikationsdatum
01.12.2009
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 12/2009
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-009-0532-2

Weitere Artikel der Ausgabe 12/2009

Medical & Biological Engineering & Computing 12/2009 Zur Ausgabe