Abstract

Cavitation is one of the major problems associated with the operation of centrifugal pumps. Cavitation occurs when vapor bubbles that are formed due to a drop in pressure in the pipes upstream of the centrifugal pump implode under the added pressure within the volute of the pump. These implosions wear away the impeller, and sometimes the volute itself, which if left unchecked, would render the pump inoperable. Much research has been done in the detection of cavitation through: indicators in certain audible frequencies, drop in the net positive suction head (NPSHa), visual inspection using a transparent casing and a stroboscopic light, paint erosion inside the volute, and on the impeller, changes in pressure within the flow or volute, and vibration within certain frequency ranges. Vibration detection is deemed as one of the more difficult methods due to other structural and environmental factors that may influence which frequencies may be present during the onset of cavitation. Vibration measurement, however, is most easily measured and deployable in an automated condition monitoring scenario. It is proposed that an increasing trend in a set of statistical parameters, rather than a firm threshold of a single parameter, would provide a robust indication for the onset of cavitation. Trends in these statistical parameters were obtained from data collected on a pump forced to cavitate under several different operating conditions. A single cavitation indicator is outlined utilizing these statistical parameters that can quantify the level of cavitation in a centrifugal pump.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat McKee K, Forbes G, Mazhar I, Entwistle R, Howard I (2011) A review of machinery diagnostics and prognostics implemented on a centrifugal pump. In: Jay Lee JN, Mathew J (eds) Proceedings of the 6th world congress on engineering asset management McKee K, Forbes G, Mazhar I, Entwistle R, Howard I (2011) A review of machinery diagnostics and prognostics implemented on a centrifugal pump. In: Jay Lee JN, Mathew J (eds) Proceedings of the 6th world congress on engineering asset management
2.
Zurück zum Zitat Čudina M (2003) Detection of cavitation phenomenon in a centrifugal pump using audible sound. Mech Syst Signal Process 17:1335–1347CrossRef Čudina M (2003) Detection of cavitation phenomenon in a centrifugal pump using audible sound. Mech Syst Signal Process 17:1335–1347CrossRef
3.
Zurück zum Zitat Černetič J, Čudina M (2011) Estimating uncertainty of measurements for cavitation detection in a centrifugal pump. Measurement 44:1293–1299CrossRef Černetič J, Čudina M (2011) Estimating uncertainty of measurements for cavitation detection in a centrifugal pump. Measurement 44:1293–1299CrossRef
4.
Zurück zum Zitat Čudina M, Prezelj J (2009) Detection of cavitation in operation of kinetic pumps. Use of discrete frequency tone in audible spectra. Appl Acoust 70:540–546CrossRef Čudina M, Prezelj J (2009) Detection of cavitation in operation of kinetic pumps. Use of discrete frequency tone in audible spectra. Appl Acoust 70:540–546CrossRef
5.
Zurück zum Zitat Neil GD, Reuben RL, Sandford PM, Brown ER, Steel JA (1997) Detection of incipient cavitation in pump using acoustic emission. Proc Inst Mech Eng 211:267–277CrossRef Neil GD, Reuben RL, Sandford PM, Brown ER, Steel JA (1997) Detection of incipient cavitation in pump using acoustic emission. Proc Inst Mech Eng 211:267–277CrossRef
6.
Zurück zum Zitat Alfayez L, Mba D, Dyson G (2005) The application of acoustic emission for detecting incipient cavitation and the best efficiency point of a 60 kW centrifugal pump: case study. NDT and E Int 38:354–358CrossRef Alfayez L, Mba D, Dyson G (2005) The application of acoustic emission for detecting incipient cavitation and the best efficiency point of a 60 kW centrifugal pump: case study. NDT and E Int 38:354–358CrossRef
7.
Zurück zum Zitat Athavale MM, Li HY, Jiang Y, Singhal AK (2002) Application of the full cavitation model to pumps and inducers. Int J Rotating Mach 8:45–56CrossRef Athavale MM, Li HY, Jiang Y, Singhal AK (2002) Application of the full cavitation model to pumps and inducers. Int J Rotating Mach 8:45–56CrossRef
8.
Zurück zum Zitat Hofmann MaS B, Coutier-Delgosha O, Fortes-Patella R, Reboud JL (2001) Experimental and numerical studies on a centrifugal pump with 2D-curved blades in cavitating condition. In: CAV 2001: Fourth international symposium on cavitation. California Institute of Technology, Pasadena, CA USA, 20–23 Jun 2001 Hofmann MaS B, Coutier-Delgosha O, Fortes-Patella R, Reboud JL (2001) Experimental and numerical studies on a centrifugal pump with 2D-curved blades in cavitating condition. In: CAV 2001: Fourth international symposium on cavitation. California Institute of Technology, Pasadena, CA USA, 20–23 Jun 2001
9.
Zurück zum Zitat Uchiyama T (1998) Numerical simulation of cavitating flow using the upstream finite element method. Appl Math Model 22:235–250CrossRef Uchiyama T (1998) Numerical simulation of cavitating flow using the upstream finite element method. Appl Math Model 22:235–250CrossRef
10.
Zurück zum Zitat Franz R, Acosta AJ, Brennen CE, Caughey TK (1990) The rotordynamic forces on a centrifugal pump impeller in the presence of cavitation. Trans ASME: J Fluids Eng 112:264–271 Franz R, Acosta AJ, Brennen CE, Caughey TK (1990) The rotordynamic forces on a centrifugal pump impeller in the presence of cavitation. Trans ASME: J Fluids Eng 112:264–271
11.
Zurück zum Zitat Rapposelli E, Cervone A, d’Agostino L (2002) A new cavitating pump rotordynamic test facility. In: 38th AIAA/ASME/SAE/ASEE joint propulsion conference and exhibit, Indianapolis, Indiana Rapposelli E, Cervone A, d’Agostino L (2002) A new cavitating pump rotordynamic test facility. In: 38th AIAA/ASME/SAE/ASEE joint propulsion conference and exhibit, Indianapolis, Indiana
12.
Zurück zum Zitat Jensen J, Dayton K (2000) Detecting cavitation in centrifugal pumps. Orbit, Nevada Jensen J, Dayton K (2000) Detecting cavitation in centrifugal pumps. Orbit, Nevada
13.
Zurück zum Zitat McKee KK, Forbes G, Mazhar I, Entwistle R, Howard I (2012) Modification of the ISO-10816 centrifugal pump vibration severity charts for use with Octave band spectral measurements. In Kotousov A (ed) 7th Australasian congress on applied mechanics, Adelaide McKee KK, Forbes G, Mazhar I, Entwistle R, Howard I (2012) Modification of the ISO-10816 centrifugal pump vibration severity charts for use with Octave band spectral measurements. In Kotousov A (ed) 7th Australasian congress on applied mechanics, Adelaide
14.
Zurück zum Zitat Standardization IOf (1998) ISO 10816-3: Mechanical vibration—evaluation of machine vibration by measurements on non-rotating parts—in Part 3: industrial machines with nominal power above 15 kW and nominal speeds between 120 r/min and 15 000 r/min when measured in situ, ISO, Switzerland Standardization IOf (1998) ISO 10816-3: Mechanical vibration—evaluation of machine vibration by measurements on non-rotating parts—in Part 3: industrial machines with nominal power above 15 kW and nominal speeds between 120 r/min and 15 000 r/min when measured in situ, ISO, Switzerland
15.
Zurück zum Zitat Standardization IOf (2009) ISO 10816-7: Mechanical vibration—evaluation of machine vibration by measurements on non-rotating parts. In: Part 7: rotordynamic pumps for industrial applications, including measurements on rotating shafts, ISO, Switzerland Standardization IOf (2009) ISO 10816-7: Mechanical vibration—evaluation of machine vibration by measurements on non-rotating parts. In: Part 7: rotordynamic pumps for industrial applications, including measurements on rotating shafts, ISO, Switzerland
16.
Zurück zum Zitat Standardization IOf (1975) ISO 532: method for calculating loudness level. International Organization for Standardization, Switzerland Standardization IOf (1975) ISO 532: method for calculating loudness level. International Organization for Standardization, Switzerland
17.
Zurück zum Zitat Wold S, Esbensen K, Geladi P (1987) Principal component analysis. Chemometr Intell Lab Syst 2:37–52CrossRef Wold S, Esbensen K, Geladi P (1987) Principal component analysis. Chemometr Intell Lab Syst 2:37–52CrossRef
18.
Zurück zum Zitat Blagrove L (2003) Cavitation detection in centrifugal pumps using vibration signals and fractal analysis. School of Mechanical and Chemical Engineering, University of Western Australia Blagrove L (2003) Cavitation detection in centrifugal pumps using vibration signals and fractal analysis. School of Mechanical and Chemical Engineering, University of Western Australia
Metadaten
Titel
A Single Cavitation Indicator Based on Statistical Parameters for a Centrifugal Pump
verfasst von
Kristoffer K. McKee
Gareth Forbes
Ilyas Mazhar
Rodney Entwistle
Melinda Hodkiewicz
Ian Howard
Copyright-Jahr
2015
DOI
https://doi.org/10.1007/978-3-319-06966-1_42

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.