Abstract

The building energy performance improvement of large-scale public buildings is very important to release China’s energy shortage pressure. The aim of the study is to find out the building energy saving potentials of large-scale public and commercial buildings by energy audit. In this paper, the energy consumption, energy performance, and audit were carried out for a typical commercial mall, the so-called largest mall in Asia, located in a hot-summer and warm-winter climate zone. The total annual energy consumption reaches 210.01 kWh/m2, of which lighting energy consumption accounts for 30.03 kWh/m2 and the lift and elevator energy consumption accounts for 40.46 kWh/m2. It is by far higher than that of the average building energy consumption in the same category. However, the annual heating, ventilation, and air-conditioning (HVAC) energy consumption is only 87.19 kWh/m2 even though they run 24/7. It proves that the energy performance of the HVAC system is good. Therefore, the building energy savings potential mainly relies on reducing the excessive usage of lighting, lifts, and elevators.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Botsarisa, P. N., & Prebezanos, S. (2004). A methodology for a thermal energy building audit. Building and Environment, 39, 195–199.CrossRef Botsarisa, P. N., & Prebezanos, S. (2004). A methodology for a thermal energy building audit. Building and Environment, 39, 195–199.CrossRef
Zurück zum Zitat Canbay, C. S., Hepbasli, A., & Gokcen, G. (2004). Evaluating performance indices of a shopping centre and implementing HVAC control principles to minimize energy usage. Energy and Buildings., 36, 587–598.CrossRef Canbay, C. S., Hepbasli, A., & Gokcen, G. (2004). Evaluating performance indices of a shopping centre and implementing HVAC control principles to minimize energy usage. Energy and Buildings., 36, 587–598.CrossRef
Zurück zum Zitat Chen, X., & Li, S. (2005). The energy saving potential of the mall and its influence for the energy consumption of air-conditioners (in Chinese). Energy Conservation., 273(4), 11–15. Chen, X., & Li, S. (2005). The energy saving potential of the mall and its influence for the energy consumption of air-conditioners (in Chinese). Energy Conservation., 273(4), 11–15.
Zurück zum Zitat Chirarattananon, S., & Taveekun, J. (2004). An OTTV-based energy estimation model for commercial buildings in Thailand. Energy and Buildings, 36, 680–689.CrossRef Chirarattananon, S., & Taveekun, J. (2004). An OTTV-based energy estimation model for commercial buildings in Thailand. Energy and Buildings, 36, 680–689.CrossRef
Zurück zum Zitat Filippin, C., Larsen, S. F., & Canori, M. (2010). Energy consumption of bioclimatic buildings in Argentina during the period 2001–2008. Renewable and Sustainable Energy Reviews, 14, 1216–1228.CrossRef Filippin, C., Larsen, S. F., & Canori, M. (2010). Energy consumption of bioclimatic buildings in Argentina during the period 2001–2008. Renewable and Sustainable Energy Reviews, 14, 1216–1228.CrossRef
Zurück zum Zitat Jiang, Y. (2007). The 2007 annual development research reports of China building energy saving (in Chinese) (pp. 7–55). Beijing: China Architecture & Building Press. Jiang, Y. (2007). The 2007 annual development research reports of China building energy saving (in Chinese) (pp. 7–55). Beijing: China Architecture & Building Press.
Zurück zum Zitat Li, J. S. M. (2008). A study of energy performance and efficiency improvement procedures of Government Offices in Hong Kong Special Administrative Region. Energy and Buildings. Energy and Buildings, 40, 1872–1875.CrossRef Li, J. S. M. (2008). A study of energy performance and efficiency improvement procedures of Government Offices in Hong Kong Special Administrative Region. Energy and Buildings. Energy and Buildings, 40, 1872–1875.CrossRef
Zurück zum Zitat Li, Z., Zhang, G., & Liu, J. (2006). Builidng energy efficiency and energy saving analysis in subtropical climates zone (in Chinese). Journal of Guangdong University of Technology, 33(1), 1–8.MATH Li, Z., Zhang, G., & Liu, J. (2006). Builidng energy efficiency and energy saving analysis in subtropical climates zone (in Chinese). Journal of Guangdong University of Technology, 33(1), 1–8.MATH
Zurück zum Zitat Mui, K. W. (2006). Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate. Energy Conversion and Management, 47, 2059–2069.CrossRef Mui, K. W. (2006). Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate. Energy Conversion and Management, 47, 2059–2069.CrossRef
Zurück zum Zitat Orosa, J. A., & Oliveira, A. C. (2009). Energy saving with passive climate control methods in Spanish office buildings. Energy and Buildings, 41, 823–828.CrossRef Orosa, J. A., & Oliveira, A. C. (2009). Energy saving with passive climate control methods in Spanish office buildings. Energy and Buildings, 41, 823–828.CrossRef
Zurück zum Zitat Poel, B., Cruchten, G. V., & Balaras, C. A. (2007). Energy performance assessment of existing dwellings. Energy and Buildings, 39, 393–403.CrossRef Poel, B., Cruchten, G. V., & Balaras, C. A. (2007). Energy performance assessment of existing dwellings. Energy and Buildings, 39, 393–403.CrossRef
Zurück zum Zitat Schiavon, S., & Melikov, A. K. (2009). Energy-saving strategies with personalized ventilation in cold climates. Energy and Buildings, 41, 543–550.CrossRef Schiavon, S., & Melikov, A. K. (2009). Energy-saving strategies with personalized ventilation in cold climates. Energy and Buildings, 41, 543–550.CrossRef
Zurück zum Zitat Zhang, G. (2007). Built environment and service specialty guidance (in Chinese) (pp. 8–21). Chongqing: Chongqing University Press. Zhang, G. (2007). Built environment and service specialty guidance (in Chinese) (pp. 8–21). Chongqing: Chongqing University Press.
Zurück zum Zitat Zhu, Y. X., & Lin, B. R. (2004). Sustainable housing and urban construction in China. Energy and Buildings, 35(1), 1289–1297. Zhu, Y. X., & Lin, B. R. (2004). Sustainable housing and urban construction in China. Energy and Buildings, 35(1), 1289–1297.
Metadaten
Titel
A study of energy performance and audit of commercial mall in hot-summer/warm-winter climate zone in China
verfasst von
Li Zhisheng
Yaolin Lin
Liao Jiawen
Liu Xuhong
Wang Xiaoxia
Publikationsdatum
01.08.2013
Verlag
Springer Netherlands
Erschienen in
Energy Efficiency / Ausgabe 3/2013
Print ISSN: 1570-646X
Elektronische ISSN: 1570-6478
DOI
https://doi.org/10.1007/s12053-012-9185-3

Weitere Artikel der Ausgabe 3/2013

Energy Efficiency 3/2013 Zur Ausgabe