Skip to main content
Erschienen in: Microsystem Technologies 11/2019

01.03.2019 | Technical Paper

An accommodative intraocular lens study and experiment, based on compliant mechanisms

verfasst von: Qiuyue Du, Yuan Li, Bin Tian

Erschienen in: Microsystem Technologies | Ausgabe 11/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

To replace the human lens with a cataract, a novel haptic-type lens based on compliant mechanisms is proposed to provide both radial and axial input displacement to change the shape and the axial movement of the optical lens, respectively. With this method, the optical power of an intraocular lens (IOL) can be remarkably improved, thereby enhancing the visual acuity of patients. In terms of the optical power of an IOL obtained by the clinical study, the maximum level is around 3.50 Diopters (D), 3 months later. However, the minimum requirement of the normal physiological function is around 8.00 D. In this study, the haptic is connected to an optical-grade silicon wafer made of polydimethylsiloxane, establishing a human optical system with an optical power of approximately 23.02 D.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Alio JL, Plaza-Puche AB, Montalban R et al (2012) Near visual outcomes with single-optic and dual-optic accommodating intraocular lenses. J Cataract Refract Surg 38(9):1568–1575CrossRef Alio JL, Plaza-Puche AB, Montalban R et al (2012) Near visual outcomes with single-optic and dual-optic accommodating intraocular lenses. J Cataract Refract Surg 38(9):1568–1575CrossRef
Zurück zum Zitat Ang M, Evans JR, Mehta JS (2014) Manual small incision cataract surgery (MSICS) with posterior chamber intraocular lens versus extracapsular cataract extraction (ECCE) with posterior chamber intraocular lens for age-related cataract. Cochrane Database Syst Rev 11:CD008811 Ang M, Evans JR, Mehta JS (2014) Manual small incision cataract surgery (MSICS) with posterior chamber intraocular lens versus extracapsular cataract extraction (ECCE) with posterior chamber intraocular lens for age-related cataract. Cochrane Database Syst Rev 11:CD008811
Zurück zum Zitat Beiko GH (2013) Comparison of visual results with accommodating intraocular lenses versus mini-monovision with a monofocal intraocular lens. J Cataract Refract Surg 39(1):48–55CrossRef Beiko GH (2013) Comparison of visual results with accommodating intraocular lenses versus mini-monovision with a monofocal intraocular lens. J Cataract Refract Surg 39(1):48–55CrossRef
Zurück zum Zitat Charman WN (2008) The eye in focus:accommodation and presbyopia. Clin Exp Optom 91(3):207–225CrossRef Charman WN (2008) The eye in focus:accommodation and presbyopia. Clin Exp Optom 91(3):207–225CrossRef
Zurück zum Zitat Choi K, Kim D (2006) Monolithic parallel linear compliant mechanism for two axes ultraprecision linear motion. Rev Sci Instr 77(6):1–7CrossRef Choi K, Kim D (2006) Monolithic parallel linear compliant mechanism for two axes ultraprecision linear motion. Rev Sci Instr 77(6):1–7CrossRef
Zurück zum Zitat Ford J, Werner L, Mamalis N (2014) Adjustable intraocular lens power technology. J Cataract Refract Surg 40(7):1205–1223CrossRef Ford J, Werner L, Mamalis N (2014) Adjustable intraocular lens power technology. J Cataract Refract Surg 40(7):1205–1223CrossRef
Zurück zum Zitat Huang WQ, Shi XQ, Wang Y (2015) Design of diamond piezoelectric micro displacement amplification mechanism. Opt Prec Eng 23(3):803–809 (in Chinese) CrossRef Huang WQ, Shi XQ, Wang Y (2015) Design of diamond piezoelectric micro displacement amplification mechanism. Opt Prec Eng 23(3):803–809 (in Chinese) CrossRef
Zurück zum Zitat Jane C (2016) A closer look at presbyopia correction: better corrective lenses and a multitude of surgical approaches give your presbyopic patients more options than ever before. Rev Optomet 153(2):54–61 Jane C (2016) A closer look at presbyopia correction: better corrective lenses and a multitude of surgical approaches give your presbyopic patients more options than ever before. Rev Optomet 153(2):54–61
Zurück zum Zitat Javitt JC, Steinert RF (2000) Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. Ophthalmology 107(11):2040–2048CrossRef Javitt JC, Steinert RF (2000) Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. Ophthalmology 107(11):2040–2048CrossRef
Zurück zum Zitat Jouaneh M, Yang R (2003) Modeling of flexure-hinge type lever mechanisms. Precision Eng 27(4):407–418CrossRef Jouaneh M, Yang R (2003) Modeling of flexure-hinge type lever mechanisms. Precision Eng 27(4):407–418CrossRef
Zurück zum Zitat Kenneth JH, Jaime A, Wolfgang H et al (2012) The final Frontier: pediatric intraocular lens power. Am J Ophthalmol 154(1):1CrossRef Kenneth JH, Jaime A, Wolfgang H et al (2012) The final Frontier: pediatric intraocular lens power. Am J Ophthalmol 154(1):1CrossRef
Zurück zum Zitat Kim H, Ahn D, Gweon D (2012) Development of a novel 3-degrees of freedom flexure based positioning system. Rev Sci Instr 83(5):1–11CrossRef Kim H, Ahn D, Gweon D (2012) Development of a novel 3-degrees of freedom flexure based positioning system. Rev Sci Instr 83(5):1–11CrossRef
Zurück zum Zitat Marchini G, Mora P, Pedrotti E et al (2007) Functional assessment of two different accommodative intraocular lenses compared with a monofocal intraocular lens. Ophthalmology 114(11):2038–2043CrossRef Marchini G, Mora P, Pedrotti E et al (2007) Functional assessment of two different accommodative intraocular lenses compared with a monofocal intraocular lens. Ophthalmology 114(11):2038–2043CrossRef
Zurück zum Zitat Mcleod SD, Portney V, Vargas LG et al (2006) Magnification induced by single optic intraocular lenses compared optic accommodative intraocular lens design. Invest Ophthalmol 40(7):30–31 Mcleod SD, Portney V, Vargas LG et al (2006) Magnification induced by single optic intraocular lenses compared optic accommodative intraocular lens design. Invest Ophthalmol 40(7):30–31
Zurück zum Zitat Mishra P, Manavalan S, Ramya M (2014) Manual small incision cataract surgery (MSIS). J Evol Med Dent Sci 3(46):11249–11261CrossRef Mishra P, Manavalan S, Ramya M (2014) Manual small incision cataract surgery (MSIS). J Evol Med Dent Sci 3(46):11249–11261CrossRef
Zurück zum Zitat Morrison D, Sternberg P, Donahue S (2005) Anterior chamber intraocular lens placement after pars plana lens ectomy in pediatric marfan syndrome. J AAPOS 9(3):240–242CrossRef Morrison D, Sternberg P, Donahue S (2005) Anterior chamber intraocular lens placement after pars plana lens ectomy in pediatric marfan syndrome. J AAPOS 9(3):240–242CrossRef
Zurück zum Zitat Ni Y, Deng ZQ, Li JB et al (2015) Multi-objective design optimization of an over-constrained flexure-based amplifier. Algorithms 8(3):424–434MathSciNetCrossRef Ni Y, Deng ZQ, Li JB et al (2015) Multi-objective design optimization of an over-constrained flexure-based amplifier. Algorithms 8(3):424–434MathSciNetCrossRef
Zurück zum Zitat Pallikaris LG, Kontadakis GA, Portaliou DM (2011) Real and pseudoaccommodation in accommodative Lenses. J Ophthalmol 2011:284961–284969 Pallikaris LG, Kontadakis GA, Portaliou DM (2011) Real and pseudoaccommodation in accommodative Lenses. J Ophthalmol 2011:284961–284969
Zurück zum Zitat Pei X, Yu JJ, Zong GH (2014) Design of compliant straight-line mechanisms using flexural joints. Chin J Mech Eng 27(1):146–153CrossRef Pei X, Yu JJ, Zong GH (2014) Design of compliant straight-line mechanisms using flexural joints. Chin J Mech Eng 27(1):146–153CrossRef
Zurück zum Zitat Prinz A, Vecsei-Marlovits PV, Sonderhof D et al (2013) Comparison of posterior capsule opacification between a 1-piece and 3-piece microincision intraocular lens. Br J Ophthalmol 97(1):18–22CrossRef Prinz A, Vecsei-Marlovits PV, Sonderhof D et al (2013) Comparison of posterior capsule opacification between a 1-piece and 3-piece microincision intraocular lens. Br J Ophthalmol 97(1):18–22CrossRef
Zurück zum Zitat Sung YL, Jeang J, Lee CH et al (2015) Fabricating optical lenses by inkjet printing and heat-assisted in situ curing of polydimethylsiloxane for smartphone microscopy. J Biomed Opt 20(047005):1–6 Sung YL, Jeang J, Lee CH et al (2015) Fabricating optical lenses by inkjet printing and heat-assisted in situ curing of polydimethylsiloxane for smartphone microscopy. J Biomed Opt 20(047005):1–6
Zurück zum Zitat Uthoff D, Haigis W, Hepper D (2013) Evaluation of the valence objective and subjective methods for measuring pseudophakic accommodation. Der Ophthalmol 110(5):441–446CrossRef Uthoff D, Haigis W, Hepper D (2013) Evaluation of the valence objective and subjective methods for measuring pseudophakic accommodation. Der Ophthalmol 110(5):441–446CrossRef
Zurück zum Zitat Werblin TP (1996) Multicomponent intraocular lens. J Refract Surg 12(1):187–189 Werblin TP (1996) Multicomponent intraocular lens. J Refract Surg 12(1):187–189
Zurück zum Zitat Xie JY, Yan SG, Lu HQ (2013) Clinical research on visual performance and pseudophakic accommodation of tetraflex accommodative intraocular lens in cataract surgery. Int J Ophthalmol 13(7):1330–1333 Xie JY, Yan SG, Lu HQ (2013) Clinical research on visual performance and pseudophakic accommodation of tetraflex accommodative intraocular lens in cataract surgery. Int J Ophthalmol 13(7):1330–1333
Zurück zum Zitat Yang Z, He Z, Li D et al (2014) Hydraulic amplifier design and its application to direct drive servo valve based on magnetostricive actuator. Sensors Actuators Phys 216:52–63CrossRef Yang Z, He Z, Li D et al (2014) Hydraulic amplifier design and its application to direct drive servo valve based on magnetostricive actuator. Sensors Actuators Phys 216:52–63CrossRef
Zurück zum Zitat Zhang JL, Chen WY, Ke XR et al (2009) Design and simulation of a kind of micro-displacement amplification mechanism. J Mach Design 26(12):9–12 (in Chinese) Zhang JL, Chen WY, Ke XR et al (2009) Design and simulation of a kind of micro-displacement amplification mechanism. J Mach Design 26(12):9–12 (in Chinese)
Zurück zum Zitat Zhang K, Zhang L, Fu L et al (2013) Magnetostrictive resonators as sensors and actuators. Sensors Actuators Phys 200:2–10CrossRef Zhang K, Zhang L, Fu L et al (2013) Magnetostrictive resonators as sensors and actuators. Sensors Actuators Phys 200:2–10CrossRef
Metadaten
Titel
An accommodative intraocular lens study and experiment, based on compliant mechanisms
verfasst von
Qiuyue Du
Yuan Li
Bin Tian
Publikationsdatum
01.03.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 11/2019
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-019-04372-9

Weitere Artikel der Ausgabe 11/2019

Microsystem Technologies 11/2019 Zur Ausgabe

Neuer Inhalt