Abstract

Purpose

This study quantifies some of the technical and physical factors that contribute to error in image-guided interventions. Errors associated with tracking, tool calibration and registration between a physical object and its corresponding image were investigated and compared with theoretical descriptions of these errors.

Methods

A precision milled linear testing apparatus was constructed to perform the measurements.

Results

The tracking error was shown to increase in linear fashion with distance normal to the camera, and the tracking error ranged between 0.15 and 0.6 mm. The tool calibration error increased as a function of distance from the camera and the reference tool (0.2–0.8 mm). The fiducial registration error was shown to improve when more points were used up until a plateau value was reached which corresponded to the total fiducial localization error (\(\sim \)0.8 mm). The target registration error distributions followed a \(\chi ^{2}\) distribution with the largest error and variation around fiducial points.

Conclusions

To minimize errors, tools should be calibrated as close as possible to the reference tool and camera, and tools should be used as close to the front edge of the camera throughout the intervention, with the camera pointed in the direction where accuracy is least needed during surgery.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
An Akaike information criterion test was performed on the data in order to determine whether a linear or quadratic model should be used to fit the data with the linear model showing a more favorable fit.
 
Literatur
1.
Zurück zum Zitat Sagi HC, Manos R, Benz R, Ordway NR, Connolly PJ (2003) Electromagnetic field-based image-guided spine surgery part one: results of a cadaveric study evaluating lumbar pedicle screw placement. Spine 28(17):2013–2018 Sagi HC, Manos R, Benz R, Ordway NR, Connolly PJ (2003) Electromagnetic field-based image-guided spine surgery part one: results of a cadaveric study evaluating lumbar pedicle screw placement. Spine 28(17):2013–2018
2.
Zurück zum Zitat O’Donnell M, Skovoroda AR, Shapo BM, Emelianov SY (1994) Internal displacement and strain imaging using ultrasonic speckle tracking. IEEE Trans Ultrason Ferroelectr Freq Control 41(3):314–325CrossRef O’Donnell M, Skovoroda AR, Shapo BM, Emelianov SY (1994) Internal displacement and strain imaging using ultrasonic speckle tracking. IEEE Trans Ultrason Ferroelectr Freq Control 41(3):314–325CrossRef
3.
Zurück zum Zitat Khadem R, Yeh C, Sadeghi-Tehrani M, Bax MR, Johnson J, Nerney W, Wilkinson EP, Shahidi R (2000) Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg 5:98–107CrossRefPubMed Khadem R, Yeh C, Sadeghi-Tehrani M, Bax MR, Johnson J, Nerney W, Wilkinson EP, Shahidi R (2000) Comparative tracking error analysis of five different optical tracking systems. Comput Aided Surg 5:98–107CrossRefPubMed
4.
Zurück zum Zitat Cuchet E, Knoplioch J, Dormont D, Marsault C (1995) Registration in neurosurgery and neuroradiotherapy applications. J Imaged Guid Surg 1:198–207CrossRef Cuchet E, Knoplioch J, Dormont D, Marsault C (1995) Registration in neurosurgery and neuroradiotherapy applications. J Imaged Guid Surg 1:198–207CrossRef
5.
Zurück zum Zitat Maurer CR Jr, Aboutanos GB, Dawant BM, Gadamsetty S, Margolin RA, Maciunas RJ, Fitzpatrick JM (1996) Effect of geometrical distortion correction in MR on image registration accuracy. J Comp Assist Tomogr 20:666–679CrossRef Maurer CR Jr, Aboutanos GB, Dawant BM, Gadamsetty S, Margolin RA, Maciunas RJ, Fitzpatrick JM (1996) Effect of geometrical distortion correction in MR on image registration accuracy. J Comp Assist Tomogr 20:666–679CrossRef
6.
Zurück zum Zitat Fonov V, Janke A, Caramanos Z, Arnold DL, Narayanan S, Pike GB, Collins DL (2010) Improved precision in the measurement of longitudinal global and regional volumetric changes via a novel MRI gradient distortion characterization and correction technique. Lect Notes Comput Sci 6326:324–333CrossRef Fonov V, Janke A, Caramanos Z, Arnold DL, Narayanan S, Pike GB, Collins DL (2010) Improved precision in the measurement of longitudinal global and regional volumetric changes via a novel MRI gradient distortion characterization and correction technique. Lect Notes Comput Sci 6326:324–333CrossRef
7.
Zurück zum Zitat Hill DLG, Maurer CR, Maciunas RJ, Barwise JA, Fitzpatrick MJ, Wang MY (1998) Measurement of intraoperative brain surface deformation under a craniotomy. Neurosurgery 43(3):514–526CrossRefPubMed Hill DLG, Maurer CR, Maciunas RJ, Barwise JA, Fitzpatrick MJ, Wang MY (1998) Measurement of intraoperative brain surface deformation under a craniotomy. Neurosurgery 43(3):514–526CrossRefPubMed
8.
Zurück zum Zitat Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative brain shift and deformations: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43(3):749–758CrossRefPubMed Roberts DW, Hartov A, Kennedy FE, Miga MI, Paulsen KD (1998) Intraoperative brain shift and deformations: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43(3):749–758CrossRefPubMed
9.
Zurück zum Zitat Nabavi A, Black PM, Gering DT, Westin CF, Mehta V, Pergolizzi RS, Ferrant M, Warfield SK, Hata N, Schwartz RB, Wells WM III, Kikinis R, Jolesz FA (2001) Serial intraoperative magnetic resonance imaging of brain shift. Neurosurgery 48(4):787–798PubMed Nabavi A, Black PM, Gering DT, Westin CF, Mehta V, Pergolizzi RS, Ferrant M, Warfield SK, Hata N, Schwartz RB, Wells WM III, Kikinis R, Jolesz FA (2001) Serial intraoperative magnetic resonance imaging of brain shift. Neurosurgery 48(4):787–798PubMed
10.
Zurück zum Zitat Hartov A, Eisner SD, Roberts DW, Paulsen KD, Platenik LA, Miga MI (1999) Error analysis for a free-hand three-dimensional ultrasound system for neuronavigation. Neurosurical Focus 6(3): Article 5 Hartov A, Eisner SD, Roberts DW, Paulsen KD, Platenik LA, Miga MI (1999) Error analysis for a free-hand three-dimensional ultrasound system for neuronavigation. Neurosurical Focus 6(3): Article 5
11.
Zurück zum Zitat Moghari MH, Abolmaesumi P (2010) Understanding the effect of bias in fiducial localization error on point-based rigid-body registration. IEEE Trans Med Imaging 29(10):1730–1738CrossRefPubMed Moghari MH, Abolmaesumi P (2010) Understanding the effect of bias in fiducial localization error on point-based rigid-body registration. IEEE Trans Med Imaging 29(10):1730–1738CrossRefPubMed
12.
Zurück zum Zitat Labadie RF, Davis BM, Fitzpatrick JM (2005) Image-guided surgery: what is the accuracy. Curr Opin Otolaryngol Head Neck Surg 13(1):27–31CrossRefPubMed Labadie RF, Davis BM, Fitzpatrick JM (2005) Image-guided surgery: what is the accuracy. Curr Opin Otolaryngol Head Neck Surg 13(1):27–31CrossRefPubMed
13.
Zurück zum Zitat Liu W, Ding H, Han H, Xue Q, Sun Z, Wang G (2009) The study of fiducial localization error of image in point-based registration. 31st Annual international conference of the IEEE EMBS, pp 5088–5091 Liu W, Ding H, Han H, Xue Q, Sun Z, Wang G (2009) The study of fiducial localization error of image in point-based registration. 31st Annual international conference of the IEEE EMBS, pp 5088–5091
14.
Zurück zum Zitat Fitzpatrick JM, West JB (2001) The distribution of target registration error in rigid-body point-based registration. IEEE Trans Med Imaging 20(9):917–927CrossRefPubMed Fitzpatrick JM, West JB (2001) The distribution of target registration error in rigid-body point-based registration. IEEE Trans Med Imaging 20(9):917–927CrossRefPubMed
15.
Zurück zum Zitat Fitzpatrick JM, West JB, Maurer CR Jr (1998) Predicting error in rigid-body point-based registration. IEEE Trans Med Imaging 17(5):694–702CrossRefPubMed Fitzpatrick JM, West JB, Maurer CR Jr (1998) Predicting error in rigid-body point-based registration. IEEE Trans Med Imaging 17(5):694–702CrossRefPubMed
16.
Zurück zum Zitat Mercier L, Del Maestro RF, Petrecca K, Kochanowska A, Drouin S, Yan CXB, Janke AL, Chen SJS, Collins DL (2011) New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation. Int J Comput Assist Radiol Surg 6(4):507–522 Mercier L, Del Maestro RF, Petrecca K, Kochanowska A, Drouin S, Yan CXB, Janke AL, Chen SJS, Collins DL (2011) New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation. Int J Comput Assist Radiol Surg 6(4):507–522
18.
Zurück zum Zitat Hummel JB, Bax MR, Figl ML, Kang Y, Maurer C Jr, Birkfellner WW, Begmann H, Shahidi R (2005) Design and application of an assessment protocol for electromagnetic tracking systems. Med Phys 32(7):2371–2379CrossRefPubMed Hummel JB, Bax MR, Figl ML, Kang Y, Maurer C Jr, Birkfellner WW, Begmann H, Shahidi R (2005) Design and application of an assessment protocol for electromagnetic tracking systems. Med Phys 32(7):2371–2379CrossRefPubMed
Metadaten
Titel
An analysis of tracking error in image-guided neurosurgery
verfasst von
Ian J. Gerard
D. Louis Collins
Publikationsdatum
01.10.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 10/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-014-1145-2

Weitere Artikel der Ausgabe 10/2015

International Journal of Computer Assisted Radiology and Surgery 10/2015 Zur Ausgabe

Premium Partner