Skip to main content

2022 | OriginalPaper | Buchkapitel

Assessment of Dose with CaF2 OSL Detectors for Individual Monitoring in Radiodiagnostic Services Using a Developed Algorithm Based on OSL Decay Curve

verfasst von : I. Pagotto, R. Lazzari, D. Filipov, L. Mariano, A. L. M. C. Malthez

Erschienen in: XXVII Brazilian Congress on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

OSL and TL are luminescent techniques used for individual monitoring for the assessment of doses. Calcium fluoride (CaF2) detectors are successfully applied for personal dosimetry combined TL technique. Studies published in the last years highlight the dosimetric properties of this material with the OSL technique. Considering the advantages of OSL in personal dosimetry and luminescent properties of CaF2 detectors, in this work we developed an algorithm method for evaluation of operational quantity Hp(10) with CaF2 detectors used by workers exposed to radiation energy range find in radiodiagnostic services. A blind test with CaF2 detectors was performed. The analysis of Hp(10) results using the trumpet curve criteria was performed for both setups of energy range of x-ray photon beam. In both blind tests, the criteria of the trumpet curve were fulfilled, demonstrating the applicability of CaF2 detectors with the OSL technique, as the developed algorithm, in radiation monitoring for workers at diagnostic imaging services.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Yukihara E, Mckeever S. (2011) Optically stimulated luminescence: fundamentals and applications, 1 edn. Wiley, Sl Yukihara E, Mckeever S. (2011) Optically stimulated luminescence: fundamentals and applications, 1 edn. Wiley, Sl
14.
Zurück zum Zitat EC. BS EN IEC 62387-1:2012 (2012) Radiation protection instrumentation. Passive integrating dosimetry systems for environmental and personal monitoring. General characteristics and performance requirements EC. BS EN IEC 62387-1:2012 (2012) Radiation protection instrumentation. Passive integrating dosimetry systems for environmental and personal monitoring. General characteristics and performance requirements
15.
Zurück zum Zitat IAEA (1999) Assessment of occupational exposures due to external sources of radiation—safety standards series No. RS-G-1.3. International Atomic Energy Agency IAEA (1999) Assessment of occupational exposures due to external sources of radiation—safety standards series No. RS-G-1.3. International Atomic Energy Agency
16.
Zurück zum Zitat ISO (1999) ISO 4037–3—X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—part 3: calibration of area and personal dosemeters. International Organization for Standardization, Geneva ISO (1999) ISO 4037–3—X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy—part 3: calibration of area and personal dosemeters. International Organization for Standardization, Geneva
18.
Zurück zum Zitat Malthez ALMC, Martins G, Umisedo N, Yoshimura E (2018) Low-cost flexible OSL detector leaf for 2D radiation measurements. ISPR14, Cordoba Malthez ALMC, Martins G, Umisedo N, Yoshimura E (2018) Low-cost flexible OSL detector leaf for 2D radiation measurements. ISPR14, Cordoba
19.
Zurück zum Zitat Guimarães CC (2000) Implementação de Grandezas Operacionais na Monitoração Individual e de Área. Master Dissertation. Universidade de São Paulo, São Paulo Guimarães CC (2000) Implementação de Grandezas Operacionais na Monitoração Individual e de Área. Master Dissertation. Universidade de São Paulo, São Paulo
20.
Zurück zum Zitat Reina TR, Vieira D, Costa P (2013) Determinação e Validação das Qualidades de radiação RQR e RQA da IAEA. In: XVIII Congresso Brasileiro de Física Médica. São Pedro, [s.n.] Reina TR, Vieira D, Costa P (2013) Determinação e Validação das Qualidades de radiação RQR e RQA da IAEA. In: XVIII Congresso Brasileiro de Física Médica. São Pedro, [s.n.]
Metadaten
Titel
Assessment of Dose with CaF2 OSL Detectors for Individual Monitoring in Radiodiagnostic Services Using a Developed Algorithm Based on OSL Decay Curve
verfasst von
I. Pagotto
R. Lazzari
D. Filipov
L. Mariano
A. L. M. C. Malthez
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_358