Abstract

To the best of the authors’ knowledge, testing the biocompatibility of graphene coatings can be considered as the first to demonstrate human carotid endothelial cell (HCtAEC) proliferation on Au, graphene oxide–coated Au (Au/GO), and reduced graphene oxide–coated Au (Au/rGO) surfaces. We hypothesized that stent material modified with graphene (G)-based coatings could be used as electrodes for electrical impedance spectroscopy (EIS) in monitoring cell cultures, i.e., endothelialization. Alamar Blue cell viability assay and cell staining and cell counting with optical images were performed. For EIS analysis, an EIS sensor consisting of Au surface electrodes was produced by the photolithographic technique. Surface characterizations were performed by considering scanning electron microscope (SEM) and water contact angle analyses. Results showed that GO and rGO coatings did not prevent neither the electrical measurements nor the cell proliferation and that rGO had a positive effect on HCtAEC proliferation. The rate of increase of impedance change from day 1 to day 10 was nearly fivefold for all electrode surfaces. Alamar Blue assay performed to monitor cell proliferation rates between groups, and rGO has shown the highest Alamar Blue reduction value of 43.65 ± 8.79%.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Bedair TM, ElNaggar MA, Joung YK, Han DK (2017) Recent advances to accelerate re-endothelialization for vascular stents. J Tissue Eng 8:204173141773154 Bedair TM, ElNaggar MA, Joung YK, Han DK (2017) Recent advances to accelerate re-endothelialization for vascular stents. J Tissue Eng 8:204173141773154
2.
Zurück zum Zitat Zhang K, Liu T, Li J, Chen J, Wang J, Huang N (2013) Surface modification of implanted cardiovascular metal stents : from antithrombosis and antirestenosis to endothelialization. J Biomed Mater Res A 102A:588–609 Zhang K, Liu T, Li J, Chen J, Wang J, Huang N (2013) Surface modification of implanted cardiovascular metal stents : from antithrombosis and antirestenosis to endothelialization. J Biomed Mater Res A 102A:588–609
3.
Zurück zum Zitat Curcio A, Torella D, Indolfi C (2011) Mechanisms of smooth muscle cell proliferation and endothelial regeneration after vascular injury and stenting. Circ J 75(6):1287–1296PubMed Curcio A, Torella D, Indolfi C (2011) Mechanisms of smooth muscle cell proliferation and endothelial regeneration after vascular injury and stenting. Circ J 75(6):1287–1296PubMed
4.
Zurück zum Zitat Tan CH, Muhamad N, Abdullah MMAB (2017) Surface topographical modification of coronary stent: a review. IOP Conf Ser Mater Sci Eng 209(012031):1–9 Tan CH, Muhamad N, Abdullah MMAB (2017) Surface topographical modification of coronary stent: a review. IOP Conf Ser Mater Sci Eng 209(012031):1–9
5.
Zurück zum Zitat Xu X et al (2017) Polymer coating embolism from intravascular medical devices — a clinical literature review. J Biomater Appl 114(1):18L–21L Xu X et al (2017) Polymer coating embolism from intravascular medical devices — a clinical literature review. J Biomater Appl 114(1):18L–21L
6.
Zurück zum Zitat Li G, Yang P, Qin W, Maitz MF, Zhou S, Huang N (2011) The effect of coimmobilizing heparin and fibronectin on titanium on hemocompatibility and endothelialization. Biomaterials 32(21):4691–4703PubMed Li G, Yang P, Qin W, Maitz MF, Zhou S, Huang N (2011) The effect of coimmobilizing heparin and fibronectin on titanium on hemocompatibility and endothelialization. Biomaterials 32(21):4691–4703PubMed
7.
Zurück zum Zitat Chen Y, Shayan M, Yeo WH, Chun Y (2017) Assessment of endothelial cell growth behavior in thin film nitinol. Biochip J 11(1):39–45 Chen Y, Shayan M, Yeo WH, Chun Y (2017) Assessment of endothelial cell growth behavior in thin film nitinol. Biochip J 11(1):39–45
8.
Zurück zum Zitat Liu Y et al (Sep. 2014) Tailoring of the dopamine coated surface with VEGF loaded heparin/poly-l-lysine particles for anticoagulation and accelerate in situ endothelialization. J Biomed Mater Res A:1–11 Liu Y et al (Sep. 2014) Tailoring of the dopamine coated surface with VEGF loaded heparin/poly-l-lysine particles for anticoagulation and accelerate in situ endothelialization. J Biomed Mater Res A:1–11
9.
Zurück zum Zitat Buccheri D, Piraino D, Andolina G, Cortese B (2016) Understanding and managing in-stent restenosis: a review of clinical data, from pathogenesis to treatment. J Thorac Dis 8(10):E1150–E1162PubMedPubMedCentral Buccheri D, Piraino D, Andolina G, Cortese B (2016) Understanding and managing in-stent restenosis: a review of clinical data, from pathogenesis to treatment. J Thorac Dis 8(10):E1150–E1162PubMedPubMedCentral
10.
Zurück zum Zitat Rebagay G, Bangalore S (2019) Biodegradable polymers and stents: the next generation? Curr Cardiovasc Risk Rep 13(8):22 Rebagay G, Bangalore S (2019) Biodegradable polymers and stents: the next generation? Curr Cardiovasc Risk Rep 13(8):22
11.
Zurück zum Zitat Ge S et al. (2019) Inhibition of in-stent restenosis after graphene oxide double-layer drug coating with good biocompatibility. Regen Biomater Oct 6(5):299–309 Ge S et al. (2019) Inhibition of in-stent restenosis after graphene oxide double-layer drug coating with good biocompatibility. Regen Biomater Oct 6(5):299–309
12.
Zurück zum Zitat Cardenas L, MacLeod J, Lipton-Duffin J, Seifu DG, Popescu F, Siaj M, Mantovani D, Rosei F (2014) Reduced graphene oxide growth on 316L stainless steel for medical applications. Nanoscale 6(15):8664–8670PubMed Cardenas L, MacLeod J, Lipton-Duffin J, Seifu DG, Popescu F, Siaj M, Mantovani D, Rosei F (2014) Reduced graphene oxide growth on 316L stainless steel for medical applications. Nanoscale 6(15):8664–8670PubMed
13.
Zurück zum Zitat Podila R, Moore T, Alexis F, Rao AM (2013) Graphene coatings for enhanced hemo-compatibility of nitinol stents. RSC Adv 3(6):1660 Podila R, Moore T, Alexis F, Rao AM (2013) Graphene coatings for enhanced hemo-compatibility of nitinol stents. RSC Adv 3(6):1660
14.
Zurück zum Zitat Pan CJ, Pang LQ, Gao F, Wang YN, Liu T, Ye W, Hou YH (2016) Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface. Mater Sci Eng C 63:333–340 Pan CJ, Pang LQ, Gao F, Wang YN, Liu T, Ye W, Hou YH (2016) Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface. Mater Sci Eng C 63:333–340
15.
Zurück zum Zitat Shedden L, Kennedy S, Wadsworth R, Connolly P (2010) Towards a self-reporting coronary artery stent--measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques. Biosens Bioelectron 26(2):661–666PubMed Shedden L, Kennedy S, Wadsworth R, Connolly P (2010) Towards a self-reporting coronary artery stent--measuring neointimal growth associated with in-stent restenosis using electrical impedance techniques. Biosens Bioelectron 26(2):661–666PubMed
16.
Zurück zum Zitat Occhiuzzi C, Contri G, Marrocco G (2012) Design of implanted RFID tags for passive sensing of human body: the STENTag. IEEE Trans Antennas Propag 60(7):3146–3154 Occhiuzzi C, Contri G, Marrocco G (2012) Design of implanted RFID tags for passive sensing of human body: the STENTag. IEEE Trans Antennas Propag 60(7):3146–3154
17.
Zurück zum Zitat Anh-Nguyen T, Tiberius B, Pliquett U, Urban GA (2015) An impedance biosensor for monitoring cancer cell attachment, spreading and drug-induced apoptosis. Sensors Actuators A Phys 241:231–237 Anh-Nguyen T, Tiberius B, Pliquett U, Urban GA (2015) An impedance biosensor for monitoring cancer cell attachment, spreading and drug-induced apoptosis. Sensors Actuators A Phys 241:231–237
18.
Zurück zum Zitat Yi-Yu L, Ji-Jer H, Yu-Jie H, Kuo-Sheng C (2013) Cell growth characterization using multi-electrode bioimpedance spectroscopy. Meas Sci Technol 24(3):35701 Yi-Yu L, Ji-Jer H, Yu-Jie H, Kuo-Sheng C (2013) Cell growth characterization using multi-electrode bioimpedance spectroscopy. Meas Sci Technol 24(3):35701
19.
Zurück zum Zitat Cho S, Thielecke H (2008) Electrical characterization of human mesenchymal stem cell growth on microelectrode. Microelectron Eng 85(5–6):1272–1274 Cho S, Thielecke H (2008) Electrical characterization of human mesenchymal stem cell growth on microelectrode. Microelectron Eng 85(5–6):1272–1274
20.
Zurück zum Zitat Qiu Y, Liao R, Zhang X (2009) Impedance-based monitoring of ongoing cardiomyocyte death induced by tumor necrosis factor-alpha. Biophys J 96(5):1985–1991PubMedPubMedCentral Qiu Y, Liao R, Zhang X (2009) Impedance-based monitoring of ongoing cardiomyocyte death induced by tumor necrosis factor-alpha. Biophys J 96(5):1985–1991PubMedPubMedCentral
21.
Zurück zum Zitat Pradhan R, Rajput S, Mandal M, Mitra A, Das S (2014) Frequency dependent impedimetric cytotoxic evaluation of anticancer drug on breast cancer cell. Biosens Bioelectron 55:44–50PubMed Pradhan R, Rajput S, Mandal M, Mitra A, Das S (2014) Frequency dependent impedimetric cytotoxic evaluation of anticancer drug on breast cancer cell. Biosens Bioelectron 55:44–50PubMed
22.
Zurück zum Zitat Yun Y, Dong Z, Tan Z, Schulz MJ (2010) Development of an electrode cell impedance method to measure osteoblast cell activity in magnesium-conditioned media. Anal Bioanal Chem 396(8):3009–3015PubMed Yun Y, Dong Z, Tan Z, Schulz MJ (2010) Development of an electrode cell impedance method to measure osteoblast cell activity in magnesium-conditioned media. Anal Bioanal Chem 396(8):3009–3015PubMed
23.
Zurück zum Zitat Mansor AFM, Ibrahim I, Zainuddin AA, Voiculescu I, Nordin AN (2017) Modeling and development of screen-printed impedance biosensor for cytotoxicity studies of lung carcinoma cells. Med Biol Eng Comput:1–9 Mansor AFM, Ibrahim I, Zainuddin AA, Voiculescu I, Nordin AN (2017) Modeling and development of screen-printed impedance biosensor for cytotoxicity studies of lung carcinoma cells. Med Biol Eng Comput:1–9
25.
Zurück zum Zitat Wang X et al (2018) Three-dimensional graphene biointerface with extremely high sensitivity to single cancer cell monitoring. Biosens Bioelectron 105(928):22–28PubMed Wang X et al (2018) Three-dimensional graphene biointerface with extremely high sensitivity to single cancer cell monitoring. Biosens Bioelectron 105(928):22–28PubMed
26.
Zurück zum Zitat Liu Q et al. (2009) Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays. Biosens Bioelectron 24(5):1305–1310 Liu Q et al. (2009) Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays. Biosens Bioelectron 24(5):1305–1310
27.
Zurück zum Zitat Franks W, Schenker I, Schmutz P, Hierlemann A (2005) Impedance characterization and modeling of electrodes for biomedical applications. IEEE Trans Biomed Eng 52(7):1295–1302PubMed Franks W, Schenker I, Schmutz P, Hierlemann A (2005) Impedance characterization and modeling of electrodes for biomedical applications. IEEE Trans Biomed Eng 52(7):1295–1302PubMed
28.
Zurück zum Zitat Lanche R et al (2015) Graphite oxide multilayers for device fabrication: enzyme-based electrical sensing of glucose. Phys Status Solidi Appl Mater Sci 212(6):1335–1341 Lanche R et al (2015) Graphite oxide multilayers for device fabrication: enzyme-based electrical sensing of glucose. Phys Status Solidi Appl Mater Sci 212(6):1335–1341
29.
Zurück zum Zitat Zhang D, Zhang Y, Zheng L, Zhan Y, He L (Apr. 2013) Graphene oxide/poly-L-lysine assembled layer for adhesion and electrochemical impedance detection of leukemia K562 cancer cells. Biosens Bioelectron 42:112–118PubMed Zhang D, Zhang Y, Zheng L, Zhan Y, He L (Apr. 2013) Graphene oxide/poly-L-lysine assembled layer for adhesion and electrochemical impedance detection of leukemia K562 cancer cells. Biosens Bioelectron 42:112–118PubMed
30.
Zurück zum Zitat Flaherty ML, Kissela B, Khoury JC, Alwell K, Moomaw CJ, Woo D, Khatri P, Ferioli S, Adeoye O, Broderick JP, Kleindorfer D (2012) Carotid artery stenosis as a cause of stroke. Neuroepidemiology 40(1):36–41PubMedPubMedCentral Flaherty ML, Kissela B, Khoury JC, Alwell K, Moomaw CJ, Woo D, Khatri P, Ferioli S, Adeoye O, Broderick JP, Kleindorfer D (2012) Carotid artery stenosis as a cause of stroke. Neuroepidemiology 40(1):36–41PubMedPubMedCentral
32.
Zurück zum Zitat King DE (1995) Oxidation of gold by ultraviolet light and ozone at 25 °C. J Vac Sci Technol A Vacuum, Surfaces, Film 13(3):1247–1253 King DE (1995) Oxidation of gold by ultraviolet light and ozone at 25 °C. J Vac Sci Technol A Vacuum, Surfaces, Film 13(3):1247–1253
33.
Zurück zum Zitat Ron H, Matlis S, Rubinstein I (1998) Self-assembled monolayers on oxidized metals. 2. Gold surface oxidative pretreatment, monolayer properties, and depression formation. Langmuir 14(5):1116–1121 Ron H, Matlis S, Rubinstein I (1998) Self-assembled monolayers on oxidized metals. 2. Gold surface oxidative pretreatment, monolayer properties, and depression formation. Langmuir 14(5):1116–1121
34.
Zurück zum Zitat Woodward JT, Walker ML, Meuse CW, Vanderah DJ, Poirier GE, Plant AL (2000) Effect of an oxidized gold substrate on alkanethiol self-assembly. Langmuir 16(12):5347–5353 Woodward JT, Walker ML, Meuse CW, Vanderah DJ, Poirier GE, Plant AL (2000) Effect of an oxidized gold substrate on alkanethiol self-assembly. Langmuir 16(12):5347–5353
35.
Zurück zum Zitat Slaughter GE, Hobson R (2009) An impedimetric biosensor based on PC 12 cells for the monitoring of exogenous agents. Biosens Bioelectron 24(5):1153–1158PubMed Slaughter GE, Hobson R (2009) An impedimetric biosensor based on PC 12 cells for the monitoring of exogenous agents. Biosens Bioelectron 24(5):1153–1158PubMed
36.
Zurück zum Zitat Xu C, Yuan R, Wang X (2014) Selective reduction of graphene oxide. Carbon N Y 71(1):345 Xu C, Yuan R, Wang X (2014) Selective reduction of graphene oxide. Carbon N Y 71(1):345
40.
Zurück zum Zitat Neirynck P, Schimer J, Jonkheijm P, Milroy LG, Cigler P, Brunsveld L (2015) Carborane-β-cyclodextrin complexes as a supramolecular connector for bioactive surfaces. J Mater Chem B 3(4):539–545PubMed Neirynck P, Schimer J, Jonkheijm P, Milroy LG, Cigler P, Brunsveld L (2015) Carborane-β-cyclodextrin complexes as a supramolecular connector for bioactive surfaces. J Mater Chem B 3(4):539–545PubMed
41.
Zurück zum Zitat Yu HZ, Zhao JW, Wang YQ, Cai SM, Liu ZF (1997) Fabricating an azobenzene self-assembled monolayer via step-by-step surface modification of a cysteamine monolayer on gold. J Electroanal Chem 438(1–2):221–224 Yu HZ, Zhao JW, Wang YQ, Cai SM, Liu ZF (1997) Fabricating an azobenzene self-assembled monolayer via step-by-step surface modification of a cysteamine monolayer on gold. J Electroanal Chem 438(1–2):221–224
42.
Zurück zum Zitat Xu Q, Cheng H, Lehr J, Patil AV, Davis JJ (2015) Graphene oxide interfaces in serum based autoantibody quantification. Anal Chem 87:346–350 Xu Q, Cheng H, Lehr J, Patil AV, Davis JJ (2015) Graphene oxide interfaces in serum based autoantibody quantification. Anal Chem 87:346–350
43.
Zurück zum Zitat Robinson JT, Perkins FK, Snow ES, Wei Z, Sheehan PE (2008) Reduced graphene oxide molecular sensors. Nano Lett 8(10):3137–3140PubMed Robinson JT, Perkins FK, Snow ES, Wei Z, Sheehan PE (2008) Reduced graphene oxide molecular sensors. Nano Lett 8(10):3137–3140PubMed
44.
Zurück zum Zitat Lee JS, Yoon JC, Jang JH (2013) A route towards superhydrophobic graphene surfaces: surface-treated reduced graphene oxide spheres. J Mater Chem A 1(25):7312–7315 Lee JS, Yoon JC, Jang JH (2013) A route towards superhydrophobic graphene surfaces: surface-treated reduced graphene oxide spheres. J Mater Chem A 1(25):7312–7315
45.
Zurück zum Zitat Wegener J, Keese CR, Giaever I (2000) Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces. Exp Cell Res 259(1):158–166PubMed Wegener J, Keese CR, Giaever I (2000) Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces. Exp Cell Res 259(1):158–166PubMed
46.
Zurück zum Zitat Giaever I, Keese CR (1993) A morphological biosensor for mammalian cells. Nature 366:591–592PubMed Giaever I, Keese CR (1993) A morphological biosensor for mammalian cells. Nature 366:591–592PubMed
47.
Zurück zum Zitat Giaever I, Keese CR (1991) Micromotion of mammalian cells measured electrically. Proc Natl Acad Sci U S A 88(17):7896–7900PubMedPubMedCentral Giaever I, Keese CR (1991) Micromotion of mammalian cells measured electrically. Proc Natl Acad Sci U S A 88(17):7896–7900PubMedPubMedCentral
48.
Zurück zum Zitat Zhang X, Wang W, Li F, Voiculescu I (2017) Stretchable impedance sensor for mammalian cell proliferation measurements. Lab Chip 17(12):2054–2066PubMed Zhang X, Wang W, Li F, Voiculescu I (2017) Stretchable impedance sensor for mammalian cell proliferation measurements. Lab Chip 17(12):2054–2066PubMed
49.
Zurück zum Zitat Zhang F, Jin T, Hu Q, He P (2018) Distinguishing skin cancer cells and normal cells using electrical impedance spectroscopy. J Electroanal Chem 823(2017):531–536 Zhang F, Jin T, Hu Q, He P (2018) Distinguishing skin cancer cells and normal cells using electrical impedance spectroscopy. J Electroanal Chem 823(2017):531–536
50.
Zurück zum Zitat Arias LR, Perry CA, Yang L (2010) Real-time electrical impedance detection of cellular activities of oral cancer cells. Biosens Bioelectron 25(10):2225–2231PubMed Arias LR, Perry CA, Yang L (2010) Real-time electrical impedance detection of cellular activities of oral cancer cells. Biosens Bioelectron 25(10):2225–2231PubMed
51.
Zurück zum Zitat Lanche R, Pachauri V, Koppenhöfer D, Wagner P, Ingebrandt S (2014) Reduced graphene oxide-based sensing platform for electric cell-substrate impedance sensing. Phys Status Solidi 211(6):1404–1409 Lanche R, Pachauri V, Koppenhöfer D, Wagner P, Ingebrandt S (2014) Reduced graphene oxide-based sensing platform for electric cell-substrate impedance sensing. Phys Status Solidi 211(6):1404–1409
52.
Zurück zum Zitat Chinnadayyala SR, Park J, Choi Y, Han JH, Yagati AK, Cho S (2019) Electrochemical impedance characterization of cell growth on reduced graphene oxide-gold nanoparticles electrodeposited on indium tin oxide electrodes. Appl Sci 9(2) Chinnadayyala SR, Park J, Choi Y, Han JH, Yagati AK, Cho S (2019) Electrochemical impedance characterization of cell growth on reduced graphene oxide-gold nanoparticles electrodeposited on indium tin oxide electrodes. Appl Sci 9(2)
53.
Zurück zum Zitat Mishima K, Mimura A, Takahara Y, Asami K, Hanai T (1991) On-line monitoring of cell concentrations by dielectric measurements. J Ferment Bioeng 72(4):291–295 Mishima K, Mimura A, Takahara Y, Asami K, Hanai T (1991) On-line monitoring of cell concentrations by dielectric measurements. J Ferment Bioeng 72(4):291–295
54.
Zurück zum Zitat Lo CM, Keese CR, Giaever I (1995) Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing. Biophys J 69(6):2800–2807PubMedPubMedCentral Lo CM, Keese CR, Giaever I (1995) Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing. Biophys J 69(6):2800–2807PubMedPubMedCentral
55.
Zurück zum Zitat Das S et al (2013) Oxygenated functional group density on graphene oxide: its effect on cell toxicity. Part Part Syst Charact 30(2):148–157 Das S et al (2013) Oxygenated functional group density on graphene oxide: its effect on cell toxicity. Part Part Syst Charact 30(2):148–157
56.
Zurück zum Zitat Gies V, Zou S (2018) Systematic toxicity investigation of graphene oxide: evaluation of assay selection, cell type, exposure period and flake size. Toxicol Res (Camb) 7(1):93–101 Gies V, Zou S (2018) Systematic toxicity investigation of graphene oxide: evaluation of assay selection, cell type, exposure period and flake size. Toxicol Res (Camb) 7(1):93–101
57.
Zurück zum Zitat Gurunathan S et al (2019) Evaluation of graphene oxide induced cellular toxicity and transcriptome analysis in human embryonic kidney cells. Nanomaterials 9(7):969PubMedCentral Gurunathan S et al (2019) Evaluation of graphene oxide induced cellular toxicity and transcriptome analysis in human embryonic kidney cells. Nanomaterials 9(7):969PubMedCentral
58.
Zurück zum Zitat Contreras-Torres FF, Rodríguez-Galván A, Guerrero-Beltrán CE, Martínez-Lorán E, Vázquez-Garza E, Ornelas-Soto N, García-Rivas G (Apr. 2017) Differential cytotoxicity and internalization of graphene family nanomaterials in myocardial cells. Mater Sci Eng C 73:633–642 Contreras-Torres FF, Rodríguez-Galván A, Guerrero-Beltrán CE, Martínez-Lorán E, Vázquez-Garza E, Ornelas-Soto N, García-Rivas G (Apr. 2017) Differential cytotoxicity and internalization of graphene family nanomaterials in myocardial cells. Mater Sci Eng C 73:633–642
59.
Zurück zum Zitat Paszek E, Czyz J, Woźnicka O, Jakubiak D, Wojnarowicz J, Łojkowski W, Stepień E (2012) Zinc oxide nanoparticles impair the integrity of human umbilical vein endothelial cell monolayer in vitro. J Biomed Nanotechnol 8(6):957–967PubMed Paszek E, Czyz J, Woźnicka O, Jakubiak D, Wojnarowicz J, Łojkowski W, Stepień E (2012) Zinc oxide nanoparticles impair the integrity of human umbilical vein endothelial cell monolayer in vitro. J Biomed Nanotechnol 8(6):957–967PubMed
60.
Zurück zum Zitat Arima Y, Iwata H (2007) Effect of wettability and surface functional groups on protein adsorption and cell adhesion using well-defined mixed self-assembled monolayers. Biomaterials 28(20):3074–3082PubMed Arima Y, Iwata H (2007) Effect of wettability and surface functional groups on protein adsorption and cell adhesion using well-defined mixed self-assembled monolayers. Biomaterials 28(20):3074–3082PubMed
61.
Zurück zum Zitat Yun YJ et al (2019) Cellular organization of three germ layer cells on different types of noncovalent functionalized graphene substrates. Mater Sci Eng C 103(2018):109729 Yun YJ et al (2019) Cellular organization of three germ layer cells on different types of noncovalent functionalized graphene substrates. Mater Sci Eng C 103(2018):109729
Metadaten
Titel
Characterization of carotid endothelial cell proliferation on Au, Au/GO, and Au/rGO surfaces by electrical impedance spectroscopy
verfasst von
Fatma Şimşek
Osman Melih Can
Bora Garipcan
Özgür Kocatürk
Yekta Ülgen
Publikationsdatum
21.04.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 7/2020
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-020-02166-0

Weitere Artikel der Ausgabe 7/2020

Medical & Biological Engineering & Computing 7/2020 Zur Ausgabe

Premium Partner