Skip to main content

2022 | OriginalPaper | Buchkapitel

Comparison of the Sensitivity and Specificity Between Mammography and Thermography in Breast Cancer Detection

verfasst von : T. G. R. Da Luz, J. C. Coninck, L. Ulbricht

Erschienen in: XXVII Brazilian Congress on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Early detection of breast cancer is a critical part of the strategy to improve diagnosis and reduce the mortality caused by this disease. Benefits and damages of screening tests have been discussed in recent years. Those discussions, along the limitations of mammography and its unavailability to our medical centers, made us evaluate the accuracy of thermography on detecting breast abnormalities. Advances in thermography technology associated with tools for improving image analysis have shown positive results so they could become a reliable tool. The objectives of this research were to verify the thermal behavior malignant or non-malignant tumor, and to compare the sensitivity and specificity of mammography imaging exams (MMG), besides the infrared thermography (TMG). There were 25 volunteers involved in the study, who performed both tests mentioned above and the biopsy (gold standard for breast cancer diagnosis). A dynamic protocol was performed with the application of skin cooling method as the images were analyzed after eight minutes of reheating. The participants are on average 49.5 years old and 72% had dense breasts. The temperatures in the tumoral regions and the thermal densities was higher in malignant tumors than benign tumors. The sensitivity and specificity for mammography were 73% and 70%, respectively and, for thermography, 83% and 74%, respectively. The results of this study show that thermography has the potential to be used as an aid to mammography in the early diagnosis of breast cancer.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
3.
Zurück zum Zitat Kandlikar SG, Perez-Raya I et al (2017) Infrared imaging technology for breast cancer detection–current status, protocols and new directions. J Heat Mass Transf:2303–2320 Kandlikar SG, Perez-Raya I et al (2017) Infrared imaging technology for breast cancer detection–current status, protocols and new directions. J Heat Mass Transf:2303–2320
4.
Zurück zum Zitat Baffa Cheloni-DJ et al (2017) Segmentaçáo Automática de Mamas em Imagens Infravermelhas Utilizando Limiarizaçáo com Refinamento Adaptativo em Bases Multivariadas. Revista de Informática Aplicada 12 Baffa Cheloni-DJ et al (2017) Segmentaçáo Automática de Mamas em Imagens Infravermelhas Utilizando Limiarizaçáo com Refinamento Adaptativo em Bases Multivariadas. Revista de Informática Aplicada 12
5.
Zurück zum Zitat Morales C, Kolosovas-Machuca ES et al (2018) An Automated method for the evaluation of breast cancer using infrared thermography. EXCLI J 17:989–998 Morales C, Kolosovas-Machuca ES et al (2018) An Automated method for the evaluation of breast cancer using infrared thermography. EXCLI J 17:989–998
6.
Zurück zum Zitat Heidari Z, Dadgostar M et al (2018) Automated segmentation of breast. Biomed Eng Appl Basis Commun 30 Heidari Z, Dadgostar M et al (2018) Automated segmentation of breast. Biomed Eng Appl Basis Commun 30
7.
Zurück zum Zitat Santana MA, Pereira JMA et al (2018) Breast cancer diagnosis based on mammary thermography and extreme learning machines. Res Biomed Eng 34:45–53CrossRef Santana MA, Pereira JMA et al (2018) Breast cancer diagnosis based on mammary thermography and extreme learning machines. Res Biomed Eng 34:45–53CrossRef
8.
Zurück zum Zitat Sathish D, Kamath S et al (2017) Asymmetry analysis of breast thermograms using automated segmentation and texture features. SIViP 11:745–752CrossRef Sathish D, Kamath S et al (2017) Asymmetry analysis of breast thermograms using automated segmentation and texture features. SIViP 11:745–752CrossRef
9.
Zurück zum Zitat Kirubha ASP, Anburajan M et al (2015) Comparison of PET-CT and thermography with breast biopsy in evaluation of breast cancer: a case study. Infrared Phys Technol 73:115–125CrossRef Kirubha ASP, Anburajan M et al (2015) Comparison of PET-CT and thermography with breast biopsy in evaluation of breast cancer: a case study. Infrared Phys Technol 73:115–125CrossRef
10.
Zurück zum Zitat Gerassimova E, Audit B et al (2014) Wavelet-based multifractal analysis of dynamic infrared thermograms to assist in early breast cancer diagnosis. Front Physiol 5 Gerassimova E, Audit B et al (2014) Wavelet-based multifractal analysis of dynamic infrared thermograms to assist in early breast cancer diagnosis. Front Physiol 5
11.
Zurück zum Zitat Desantis C et al (2015) International variation in female breast cancer incidence and mortality rates. Cancer Epidemiol Prev Biomarkers 24:1495–1506CrossRef Desantis C et al (2015) International variation in female breast cancer incidence and mortality rates. Cancer Epidemiol Prev Biomarkers 24:1495–1506CrossRef
12.
Zurück zum Zitat De Jesus Guirro RR, Vaz MMOL et al (2017) Accuracy and reliability of infrared thermography in assessment of the breasts of women affected by cancer. J Med Syst 41:87CrossRef De Jesus Guirro RR, Vaz MMOL et al (2017) Accuracy and reliability of infrared thermography in assessment of the breasts of women affected by cancer. J Med Syst 41:87CrossRef
13.
Zurück zum Zitat Antonini S, Kolaric D et al (2015) Thermographic visualization of multicentric breast carcinoma. In: International symposium. IEEE 13–16 Antonini S, Kolaric D et al (2015) Thermographic visualization of multicentric breast carcinoma. In: International symposium. IEEE 13–16
14.
Zurück zum Zitat Bozzini A, Renne G et al (2008) Sensitivity of imaging for multifocal-multicentric breast carcinoma. BMC Cancer 8:13275–16CrossRef Bozzini A, Renne G et al (2008) Sensitivity of imaging for multifocal-multicentric breast carcinoma. BMC Cancer 8:13275–16CrossRef
15.
Zurück zum Zitat Raghavendra U, Rajendra AU et al (2016) An integrated index for breast cancer identification using histogram of oriented gradient and kernel locality preserving projection features extracted from thermograms. Quantit InfraRed Thermogr J 13:195–209CrossRef Raghavendra U, Rajendra AU et al (2016) An integrated index for breast cancer identification using histogram of oriented gradient and kernel locality preserving projection features extracted from thermograms. Quantit InfraRed Thermogr J 13:195–209CrossRef
16.
Zurück zum Zitat Milosevic M, Jankovic D et al (2015) Comparative analysis of breast cancer detection in mammograms and thermograms. Biomed Eng-Biomed Tech 60:49–56 Milosevic M, Jankovic D et al (2015) Comparative analysis of breast cancer detection in mammograms and thermograms. Biomed Eng-Biomed Tech 60:49–56
17.
Zurück zum Zitat Badan GM et al (2013) Valores preditivos positivos das categorias 3, 4 e 5 do Breast Imaging Reporting and Data System (BI-RADS) em lesóes mamárias submetidas a biópsia percutánea. Radiol Bras 46:209–213 Badan GM et al (2013) Valores preditivos positivos das categorias 3, 4 e 5 do Breast Imaging Reporting and Data System (BI-RADS) em lesóes mamárias submetidas a biópsia percutánea. Radiol Bras 46:209–213
18.
Zurück zum Zitat Kazemian Omranipour RA et al (2016) Comparison of the accuracy of thermography and mammography in the detection of breast cancer. Breast Care 11:260–264 Kazemian Omranipour RA et al (2016) Comparison of the accuracy of thermography and mammography in the detection of breast cancer. Breast Care 11:260–264
19.
Zurück zum Zitat Wishart GC, Campisi M et al (2010) The accuracy of digital infrared imaging for breast cancer detection in women undergoing breast biopsy. Eur J Surg Oncol 36:535–540CrossRef Wishart GC, Campisi M et al (2010) The accuracy of digital infrared imaging for breast cancer detection in women undergoing breast biopsy. Eur J Surg Oncol 36:535–540CrossRef
20.
Zurück zum Zitat Araujo MC, Lima RCF et al (2014) Uso de imagens termográficas para classificaçáo de anormalidades de mama. Centro de Informática - Universidade Federal de Pernambuco, Brasil Araujo MC, Lima RCF et al (2014) Uso de imagens termográficas para classificaçáo de anormalidades de mama. Centro de Informática - Universidade Federal de Pernambuco, Brasil
21.
Zurück zum Zitat Acharya U et al (2012) Thermography based breast cancer detection using texture features and support vector machine. J Med Syst 36:1503–1510CrossRef Acharya U et al (2012) Thermography based breast cancer detection using texture features and support vector machine. J Med Syst 36:1503–1510CrossRef
22.
Zurück zum Zitat Corte ACR, Hernadez AJ et al (2016) Application of medical infrared thermography to sports medicine. Revista Brasileira de Medicina do Esporte 22:315–319CrossRef Corte ACR, Hernadez AJ et al (2016) Application of medical infrared thermography to sports medicine. Revista Brasileira de Medicina do Esporte 22:315–319CrossRef
23.
Zurück zum Zitat Yadav P, Jethani V et al (2016) Breast Thermograms Analysis for Cancer Detection Using Feature Extraction and Data Mining Technique. In: Proceedings of the international conference on advances in information communication technology and computing, vol 87. ACM Yadav P, Jethani V et al (2016) Breast Thermograms Analysis for Cancer Detection Using Feature Extraction and Data Mining Technique. In: Proceedings of the international conference on advances in information communication technology and computing, vol 87. ACM
Metadaten
Titel
Comparison of the Sensitivity and Specificity Between Mammography and Thermography in Breast Cancer Detection
verfasst von
T. G. R. Da Luz
J. C. Coninck
L. Ulbricht
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_316

Neuer Inhalt