Skip to main content
Erschienen in: Journal of Visualization 3/2019

02.04.2019 | Regular Paper

Comparison of turbulent flow measurement schemes for 4D flow MRI

verfasst von: Hoijn Ha, Hanwook Park

Erschienen in: Journal of Visualization | Ausgabe 3/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Recently, time-resolved 3D phase contrast magnetic resonance imaging, which is also called 4D flow MRI or 4D PC-MRI, has been widely utilized to investigate spatial and temporal variations in the hemodynamic characteristics of blood flows. The conventional 4D flow MRI only provides the ensemble-averaged mean flow information but misses flow fluctuation because of turbulence. There have been some new manners for turbulence quantification of the blood flow using 4D flow MRI to acquire the fluctuation intensity of the turbulent flow. Although the previous studies showed that a minimum of six flow encoding is needed to perfectly describe six independent components of the 3 × 3 symmetric Reynolds stress tensor, the optimum flow encoding scheme for turbulence has not been clearly revealed. In this study, we compared and evaluated the uncertainty of mean velocity and Reynolds stress tensor in 4D flow MRI with various flow encoding schemes. The results showed that six- to fifteen-direction measurements could result 29–51% less noise in the velocity field and 34–57% less noise in the TKE field. In addition, higher number of flow encoding had less noise in Reynolds stress estimation.

Graphical abstract

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Bammer R, Hope TA, Aksoy M, Alley MT (2007) Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5 T and 3.0 T in combination with parallel imaging. Magn Reson Med 57:127–140CrossRef Bammer R, Hope TA, Aksoy M, Alley MT (2007) Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5 T and 3.0 T in combination with parallel imaging. Magn Reson Med 57:127–140CrossRef
Zurück zum Zitat Barker AJ et al (2012) Bicuspid aortic valve is associated with altered wall shear stress in the ascending aorta. Circ Cardiovasc Imaging 5:457–466CrossRef Barker AJ et al (2012) Bicuspid aortic valve is associated with altered wall shear stress in the ascending aorta. Circ Cardiovasc Imaging 5:457–466CrossRef
Zurück zum Zitat Bissell MM et al (2013) Aortic dilation in bicuspid aortic valve disease flow pattern is a major contributor and differs with valve fusion type. Circ Cardiovasc Imaging 6:499–507CrossRef Bissell MM et al (2013) Aortic dilation in bicuspid aortic valve disease flow pattern is a major contributor and differs with valve fusion type. Circ Cardiovasc Imaging 6:499–507CrossRef
Zurück zum Zitat Brown RW, Cheng Y-CN, Haacke EM, Thompson MR, Venkatesan R (2014) Magnetic resonance imaging: physical principles and sequence design. Wiley, New YorkCrossRef Brown RW, Cheng Y-CN, Haacke EM, Thompson MR, Venkatesan R (2014) Magnetic resonance imaging: physical principles and sequence design. Wiley, New YorkCrossRef
Zurück zum Zitat Casas B, Lantz J, Dyverfeldt P, Ebbers T (2016) 4D flow MRI-Based pressure loss estimation in stenotic flows: evaluation using numerical simulations. Magn Reson Med 75:1808–1821CrossRef Casas B, Lantz J, Dyverfeldt P, Ebbers T (2016) 4D flow MRI-Based pressure loss estimation in stenotic flows: evaluation using numerical simulations. Magn Reson Med 75:1808–1821CrossRef
Zurück zum Zitat Cibis M, Jarvis K, Markl M, Rose M, Rigsby C, Barker AJ, Wentzel JJ (2015) The effect of resolution on viscous dissipation measured with 4D flow MRI in patients with Fontan circulation: evaluation using computational fluid dynamics. J Biomech 48:2984–2989CrossRef Cibis M, Jarvis K, Markl M, Rose M, Rigsby C, Barker AJ, Wentzel JJ (2015) The effect of resolution on viscous dissipation measured with 4D flow MRI in patients with Fontan circulation: evaluation using computational fluid dynamics. J Biomech 48:2984–2989CrossRef
Zurück zum Zitat Donati F, Figueroa CA, Smith NP, Lamata P, Nordsletten DA (2015) Non-invasive pressure difference estimation from PC-MRI using the work-energy equation. Med Image Anal 26:159–172CrossRef Donati F, Figueroa CA, Smith NP, Lamata P, Nordsletten DA (2015) Non-invasive pressure difference estimation from PC-MRI using the work-energy equation. Med Image Anal 26:159–172CrossRef
Zurück zum Zitat Dyverfeldt P, Sigfridsson A, Kvitting JPE, Ebbers T (2006) Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI. Magn Reson Med 56:850–858CrossRef Dyverfeldt P, Sigfridsson A, Kvitting JPE, Ebbers T (2006) Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI. Magn Reson Med 56:850–858CrossRef
Zurück zum Zitat Dyverfeldt P, Kvitting JPE, Sigfridsson A, Engvall J, Bolger AF, Ebbers T (2008) Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI. J Magn Reson Imaging 28:655–663CrossRef Dyverfeldt P, Kvitting JPE, Sigfridsson A, Engvall J, Bolger AF, Ebbers T (2008) Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI. J Magn Reson Imaging 28:655–663CrossRef
Zurück zum Zitat Dyverfeldt P, Gårdhagen R, Sigfridsson A, Karlsson M, Ebbers T (2009) On MRI turbulence quantification. Magn Reson Imaging 27:913–922CrossRef Dyverfeldt P, Gårdhagen R, Sigfridsson A, Karlsson M, Ebbers T (2009) On MRI turbulence quantification. Magn Reson Imaging 27:913–922CrossRef
Zurück zum Zitat Dyverfeldt P, Hope MD, Tseng EE, Saloner D (2013) Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis. JACC: Cardiovascular Imaging 6:64–71 Dyverfeldt P, Hope MD, Tseng EE, Saloner D (2013) Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis. JACC: Cardiovascular Imaging 6:64–71
Zurück zum Zitat Ebbers T, Wigström L, Bolger AF, Engvall J, Karlsson M (2001) Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI. Magn Reson Med 45:872–879CrossRef Ebbers T, Wigström L, Bolger AF, Engvall J, Karlsson M (2001) Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI. Magn Reson Med 45:872–879CrossRef
Zurück zum Zitat Fisher AB, Chien S, Barakat AI, Nerem RM (2001) Endothelial cellular response to altered shear stress. Am J Physiol Lung Cell Mol Physiol 281:L529–L533CrossRef Fisher AB, Chien S, Barakat AI, Nerem RM (2001) Endothelial cellular response to altered shear stress. Am J Physiol Lung Cell Mol Physiol 281:L529–L533CrossRef
Zurück zum Zitat Groen HC et al (2007) Plaque rupture in the carotid artery is localized at the high shear stress region a case report. Stroke 38:2379–2381CrossRef Groen HC et al (2007) Plaque rupture in the carotid artery is localized at the high shear stress region a case report. Stroke 38:2379–2381CrossRef
Zurück zum Zitat Gülan U, Binter C, Kozerke S, Holzner M (2017) Shear-scaling-based approach for irreversible energy loss estimation in stenotic aortic flow—an in vitro study. J Biomech 56:89–96CrossRef Gülan U, Binter C, Kozerke S, Holzner M (2017) Shear-scaling-based approach for irreversible energy loss estimation in stenotic aortic flow—an in vitro study. J Biomech 56:89–96CrossRef
Zurück zum Zitat Ha H et al (2016a) Turbulent kinetic energy measurement using phase contrast MRI for estimating the post-stenotic pressure drop: in vitro validation and clinical application. PLoS ONE 11:e0151540CrossRef Ha H et al (2016a) Turbulent kinetic energy measurement using phase contrast MRI for estimating the post-stenotic pressure drop: in vitro validation and clinical application. PLoS ONE 11:e0151540CrossRef
Zurück zum Zitat Ha H et al (2016b) Assessment of turbulent viscous stress using ICOSA 4D Flow MRI for prediction of hemodynamic blood damage. Sci Rep 6:39773CrossRef Ha H et al (2016b) Assessment of turbulent viscous stress using ICOSA 4D Flow MRI for prediction of hemodynamic blood damage. Sci Rep 6:39773CrossRef
Zurück zum Zitat Ha H, Lantz J, Ziegler M, Casas B, Karlsson M, Dyverfeldt P, Ebbers T (2017) Estimating the irreversible pressure drop across a stenosis by quantifying turbulence production using 4D flow MRI. Sci Rep 7:46618CrossRef Ha H, Lantz J, Ziegler M, Casas B, Karlsson M, Dyverfeldt P, Ebbers T (2017) Estimating the irreversible pressure drop across a stenosis by quantifying turbulence production using 4D flow MRI. Sci Rep 7:46618CrossRef
Zurück zum Zitat Ha H et al (2018) Age-related vascular changes affect turbulence in aortic blood flow. Front Physiol 9:36CrossRef Ha H et al (2018) Age-related vascular changes affect turbulence in aortic blood flow. Front Physiol 9:36CrossRef
Zurück zum Zitat Haraldsson H et al (2017) Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding. Magn Reson Med 79:1962–1971CrossRef Haraldsson H et al (2017) Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding. Magn Reson Med 79:1962–1971CrossRef
Zurück zum Zitat Harloff A et al (2009) 3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T. Magn Reson Med 61:65–74CrossRef Harloff A et al (2009) 3D blood flow characteristics in the carotid artery bifurcation assessed by flow-sensitive 4D MRI at 3T. Magn Reson Med 61:65–74CrossRef
Zurück zum Zitat Harloff A et al (2010) In vivo assessment of wall shear stress in the atherosclerotic aorta using flow-sensitive 4D MRI. Magn Reson Med 63:1529–1536CrossRef Harloff A et al (2010) In vivo assessment of wall shear stress in the atherosclerotic aorta using flow-sensitive 4D MRI. Magn Reson Med 63:1529–1536CrossRef
Zurück zum Zitat Hasan KM, Parker DL, Alexander AL (2001) Comparison of gradient encoding schemes for diffusion-tensor MRI. J Magn Reson Imaging 13:769–780CrossRef Hasan KM, Parker DL, Alexander AL (2001) Comparison of gradient encoding schemes for diffusion-tensor MRI. J Magn Reson Imaging 13:769–780CrossRef
Zurück zum Zitat Hsiao A, Tariq U, Alley MT, Lustig M, Vasanawala SS (2015) Inlet and outlet valve flow and regurgitant volume may be directly and reliably quantified with accelerated, volumetric phase-contrast MRI. J Magn Reson Imaging 41:376–385CrossRef Hsiao A, Tariq U, Alley MT, Lustig M, Vasanawala SS (2015) Inlet and outlet valve flow and regurgitant volume may be directly and reliably quantified with accelerated, volumetric phase-contrast MRI. J Magn Reson Imaging 41:376–385CrossRef
Zurück zum Zitat Kim GB, Ha H, Kweon J, Lee SJ, Kim Y-H, Yang DH, Kim N (2015) Post-stenotic plug-like jet with a vortex ring demonstrated by 4D flow MRI. Magn Reson Imaging 34:371–375CrossRef Kim GB, Ha H, Kweon J, Lee SJ, Kim Y-H, Yang DH, Kim N (2015) Post-stenotic plug-like jet with a vortex ring demonstrated by 4D flow MRI. Magn Reson Imaging 34:371–375CrossRef
Zurück zum Zitat Krittian SB et al (2012) A finite-element approach to the direct computation of relative cardiovascular pressure from time-resolved MR velocity data. Med Image Anal 16:1029–1037CrossRef Krittian SB et al (2012) A finite-element approach to the direct computation of relative cardiovascular pressure from time-resolved MR velocity data. Med Image Anal 16:1029–1037CrossRef
Zurück zum Zitat Ku DN, Giddens DP, Zarins CK, Glagov S (1985) Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arterioscler Thromb Vasc Biol 5:293–302 Ku DN, Giddens DP, Zarins CK, Glagov S (1985) Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress. Arterioscler Thromb Vasc Biol 5:293–302
Zurück zum Zitat Lustig M, Donoho DL, Santos JM, Pauly JM (2008) Compressed sensing MRI. IEEE Signal Process Mag 25:72–82CrossRef Lustig M, Donoho DL, Santos JM, Pauly JM (2008) Compressed sensing MRI. IEEE Signal Process Mag 25:72–82CrossRef
Zurück zum Zitat Markl M, Wallis W, Brendecke S, Simon J, Frydrychowicz A, Harloff A (2010) Estimation of global aortic pulse wave velocity by flow-sensitive 4D MRI. Magn Reson Med 63:1575–1582CrossRef Markl M, Wallis W, Brendecke S, Simon J, Frydrychowicz A, Harloff A (2010) Estimation of global aortic pulse wave velocity by flow-sensitive 4D MRI. Magn Reson Med 63:1575–1582CrossRef
Zurück zum Zitat Markl M, Kilner PJ, Ebbers T (2011a) Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:1–22CrossRef Markl M, Kilner PJ, Ebbers T (2011a) Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:1–22CrossRef
Zurück zum Zitat Markl M, Kilner PJ, Ebbers T (2011b) Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:7CrossRef Markl M, Kilner PJ, Ebbers T (2011b) Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:7CrossRef
Zurück zum Zitat Markl M, Frydrychowicz A, Kozerke S, Hope M, Wieben O (2012a) 4D flow MRI. J Magn Reson Imaging 36:1015–1036CrossRef Markl M, Frydrychowicz A, Kozerke S, Hope M, Wieben O (2012a) 4D flow MRI. J Magn Reson Imaging 36:1015–1036CrossRef
Zurück zum Zitat Markl M, Wallis W, Strecker C, Gladstone BP, Vach W, Harloff A (2012b) Analysis of pulse wave velocity in the thoracic aorta by flow-sensitive four-dimensional MRI: reproducibility and correlation with characteristics in patients with aortic atherosclerosis. J Magn Reson Imaging 35:1162–1168CrossRef Markl M, Wallis W, Strecker C, Gladstone BP, Vach W, Harloff A (2012b) Analysis of pulse wave velocity in the thoracic aorta by flow-sensitive four-dimensional MRI: reproducibility and correlation with characteristics in patients with aortic atherosclerosis. J Magn Reson Imaging 35:1162–1168CrossRef
Zurück zum Zitat Morbiducci U et al (2009) vivo quantification of helical blood flow in human aorta by time-resolved three-dimensional cine phase contrast magnetic resonance imaging. Ann Biomed Eng 37:516–531CrossRef Morbiducci U et al (2009) vivo quantification of helical blood flow in human aorta by time-resolved three-dimensional cine phase contrast magnetic resonance imaging. Ann Biomed Eng 37:516–531CrossRef
Zurück zum Zitat Morbiducci U, Ponzini R, Rizzo G, Biancolini ME, Iannaccone F, Gallo D, Redaelli A (2012) Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta. Med Biol Eng Comput 50:145–154CrossRef Morbiducci U, Ponzini R, Rizzo G, Biancolini ME, Iannaccone F, Gallo D, Redaelli A (2012) Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta. Med Biol Eng Comput 50:145–154CrossRef
Zurück zum Zitat Pelc NJ, Bernstein MA, Shimakawa A, Glover GH (1991) Encoding strategies for three-direction phase-contrast MR imaging of flow. J Magn Reson Imaging 1:405–413CrossRef Pelc NJ, Bernstein MA, Shimakawa A, Glover GH (1991) Encoding strategies for three-direction phase-contrast MR imaging of flow. J Magn Reson Imaging 1:405–413CrossRef
Zurück zum Zitat Petersson S, Sigfridsson A, Dyverfeldt P, Carlhäll CJ, Ebbers T (2015) Retrospectively gated intracardiac 4D flow MRI using spiral trajectories. Magn Reson Med 75:196–206CrossRef Petersson S, Sigfridsson A, Dyverfeldt P, Carlhäll CJ, Ebbers T (2015) Retrospectively gated intracardiac 4D flow MRI using spiral trajectories. Magn Reson Med 75:196–206CrossRef
Zurück zum Zitat Pope SB (2001) Turbulent flows. IOP Publishing, BristolMATH Pope SB (2001) Turbulent flows. IOP Publishing, BristolMATH
Zurück zum Zitat Slager C, Wentzel J, Gijsen F, Thury A, Van der Wal A, Schaar J, Serruys P (2005) The role of shear stress in the destabilization of vulnerable plaques and related therapeutic implications. Nat Clin Pract Cardiovasc Med 2:456–464CrossRef Slager C, Wentzel J, Gijsen F, Thury A, Van der Wal A, Schaar J, Serruys P (2005) The role of shear stress in the destabilization of vulnerable plaques and related therapeutic implications. Nat Clin Pract Cardiovasc Med 2:456–464CrossRef
Zurück zum Zitat von Spiczak J, Crelier G, Giese D, Kozerke S, Maintz D, Bunck AC (2015) Quantitative analysis of vortical blood flow in the thoracic aorta using 4D phase contrast MRI. PLoS ONE 10:e0139025CrossRef von Spiczak J, Crelier G, Giese D, Kozerke S, Maintz D, Bunck AC (2015) Quantitative analysis of vortical blood flow in the thoracic aorta using 4D phase contrast MRI. PLoS ONE 10:e0139025CrossRef
Zurück zum Zitat Zwart NR, Pipe JG (2013) Multidirectional high-moment encoding in phase contrast MRI. Magn Reson Med 69:1553–1563CrossRef Zwart NR, Pipe JG (2013) Multidirectional high-moment encoding in phase contrast MRI. Magn Reson Med 69:1553–1563CrossRef
Metadaten
Titel
Comparison of turbulent flow measurement schemes for 4D flow MRI
verfasst von
Hoijn Ha
Hanwook Park
Publikationsdatum
02.04.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Journal of Visualization / Ausgabe 3/2019
Print ISSN: 1343-8875
Elektronische ISSN: 1875-8975
DOI
https://doi.org/10.1007/s12650-019-00556-7

Weitere Artikel der Ausgabe 3/2019

Journal of Visualization 3/2019 Zur Ausgabe

Premium Partner